• Title/Summary/Keyword: Tooth Development

Search Result 601, Processing Time 0.029 seconds

Corticotomy for orthodontic tooth movement

  • Lee, Won
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.44 no.6
    • /
    • pp.251-258
    • /
    • 2018
  • Corticotomy was introduced as a surgical procedure to shorten orthodontic treatment time. Corticotomy removes the cortical bone that strongly resists orthodontic force in the jaw and keeps the marrow bone to maintain blood circulation and continuity of bone tissues to reduce risk of necrosis and facilitate tooth movement. In the 21st century, the concept of regional acceleratory phenomenon was introduced and the development of the skeletal anchorage system using screw and plate enabled application of orthopedic force beyond conventional orthodontic force, so corticotomy has been applied to more cases. Also, various modified methods of minimally invasive techniques have been introduced to reduce the patient's discomfort due to surgical intervention and complications after surgery. We will review the history of corticotomy, its mechanism of action, and various modified procedures and indications.

Triplication of upper right primary anterior teeth : a case report (상악 우측 유전치부에 발생한 삼중치 : 증례 보고)

  • Bae, Sangyong;Lee, Jewoo;Ra, Jiyoung
    • The Journal of the Korean dental association
    • /
    • v.57 no.10
    • /
    • pp.588-594
    • /
    • 2019
  • The fusion is an anomalous union of two or more tooth germ at some stage in the development process resulting in a decreased number of teeth in the dental arch. Fusion is common odontogenic anomaly but triplication of primary teeth is a rare phenomenon. We report a case of a 3 - year - old girl who visited our clinic for the pain on maxillary anterior tooth. The patient was diagnosed by the fusion of a the maxillary primary right central and lateral incisor with a supernumerary tooth and caries of dentine. And then, Endodontic treatment and composite resin restoration were performed on the triple teeth. After follow-up of 6 months period, there was no marked complications.

  • PDF

Analyzing clinical and genetic aspects of axonal Charcot-Marie-Tooth disease

  • Kwon, Hye Mi;Choi, Byung-Ok
    • Journal of Genetic Medicine
    • /
    • v.18 no.2
    • /
    • pp.83-93
    • /
    • 2021
  • Charcot-Marie-Tooth disease (CMT) is the most common hereditary motor and sensory peripheral neuropathy. CMT is usually classified into two categories based on pathology: demyelinating CMT type 1 (CMT1) and axonal CMT type 2 (CMT2) neuropathy. CMT1 can be distinguished by assessing the median motor nerve conduction velocity as greater than 38 m/s. The main clinical features of axonal CMT2 neuropathy are distal muscle weakness and loss of sensory and areflexia. In addition, they showed unusual clinical features, including delayed development, hearing loss, pyramidal signs, vocal cord paralysis, optic atrophy, and abnormal pupillary reactions. Recently, customized treatments for genetic diseases have been developed, and pregnancy diagnosis can enable the birth of a normal child when the causative gene mutation is found in CMT2. Therefore, accurate diagnosis based on genotype/phenotypic correlations is becoming more important. In this review, we describe the latest findings on the phenotypic characteristics of axonal CMT2 neuropathy. We hope that this review will be useful for clinicians in regard to the diagnosis and treatment of CMT.

Experimental Study for the Durability Enhancement of Plastic Spur Gear (플라스틱스퍼기어의 내구성향상에 관한 실험연구)

  • Kim, Chung-Hyeon;An, Hyo-Seok;Jeong, Tae-Hyeong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.9
    • /
    • pp.1914-1922
    • /
    • 2002
  • Operating test of power-transmission plastic spur gears were performed inspecting both characteristics of friction-wear and endurance, and suggesting endurance improvement method that either drills internal holes of tooth or inserts metallic pin in the internal hole of tooth and verifying this newly-provided method. In case of acetal gears, amount of friction-wear is observed to increase by development of plastic deformation and increase of tooth stiffness due to brittle material property of acetal. To the contrary, in case of nylon gears, suggested method is shown to drop down the tooth temperature for about 3∼10$^{\circ}C$ than original gear, thus amount of wear is reduced by over 30% and operating lift prolonged by more than 200%. Hence, suggested method is proved to be practically applicable to the plastic gears made by soft polymers such as Nylon.

Development of Diagnostic Device for the Tooth Crack Using Transmitted Light (투과 광을 이용한 치아 균열 진단기 개발)

  • Yang, Jeong Su;Seo, Hyo-Gi;Lee, Joon-Seok;Choi, Keum Yeon;Cho, Jin-Hyoung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.5
    • /
    • pp.317-320
    • /
    • 2016
  • In order to acquire clear images capable of diagnosing cracked tooth by light transmission, the optical properties of LED light source were examined. Based on the results, the prototype which basically consisted of LED light source, bandpass filter and commercial compact camera module was designed and manufactured. The wavelength and optical power of the LED in the prototype were 850 nm and 7 mW/Sr, respectively. In evaluation of the prototype using microscope, the observation of the crack with width of above $17{\mu}m$ was possible. In addition, image analysis to obtain shape information on the observed tooth cracks was carried out.

Characteristics of Vibration Condition Indicator with Gear Tooth Damage (기어 손상에 따른 진동 상태표시기 특성 평가)

  • Lee, Dong-Hyung;Lee, Woong-Yong;Moon, Kyung-Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.32 no.7
    • /
    • pp.611-617
    • /
    • 2015
  • In the development of a vibration-based condition monitoring system in gearbox, one of the most important research topics is a quantitative analysis and test of the effect of gear damage on vibration of gearbox. This paper presents the evaluation result of vibration condition indicator according to the gear tooth damage through the vibration test of gearbox. The dynamic load test was performed with high speed railway (KTX)'s gearbox. The vibration of gearbox was measured according to a rotational speed change with the common gear fault modes, such as pitting and tooth breakage. The characteristics and the possibility of applying of vibration condition indicator on condition monitoring system were analyzed. As a result, the value of most condition indicator is gradually increased with the severity of gear faults. The NA6 indicator shows a low variation with the rotational speed change and high sensitivity in accordance with the gear fault.

Alveolar ridge preservation of an extraction socket using autogenous tooth bone graft material for implant site development: prospective case series

  • Kim, Young-Kyun;Yun, Pil-Young;Um, In-Woong;Lee, Hyo-Jung;Yi, Yang-Jin;Bae, Ji-Hyun;Lee, Junho
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.6
    • /
    • pp.521-527
    • /
    • 2014
  • This case series evaluated the clinical efficacy of autogenous tooth bone graft material (AutoBT) in alveolar ridge preservation of an extraction socket. Thirteen patients who received extraction socket graft using AutoBT followed by delayed implant placements from Nov. 2008 to Aug. 2010 were evaluated. A total of fifteen implants were placed. The primary and secondary stability of the placed implants were an average of 58 ISQ and 77.9 ISQ, respectively. The average amount of crestal bone loss around the implant was 0.05 mm during an average of 22.5 months (from 12 to 34 months) of functional loading. Newly formed tissues were evident from the 3-month specimen. Within the limitations of this case, autogenous tooth bone graft material can be a favorable bone substitute for extraction socket graft due to its good bone remodeling and osteoconductivity.

Role of cone-beam computed tomography in the evaluation of a paradental cyst related to the fusion of a wisdom tooth with a paramolar: A rare case report

  • Ozcan, Gozde;Sekerci, Ahmet Ercan;Soylu, Emrah;Nazlim, Sinan;Amuk, Mehmet;Avci, Fatma
    • Imaging Science in Dentistry
    • /
    • v.46 no.1
    • /
    • pp.57-62
    • /
    • 2016
  • Fusion is an abnormality of tooth development defined as the union of two developing dental germs, resulting in a single large dental structure. This irregular tooth morphology is associated with a high predisposition to dental caries and periodontal diseases. As a result of recurring inflammatory periodontal processes, disorders such as periodontal pocket, pericoronitis, and paradental cysts may develop. A rare mandibular anatomic variation is the retromolar canal, which is very significant for surgical procedures. The fusion of a paramolar and mandibular third molar associated with a paradental cyst co-occurring with the presence of a retromolar canal is rare, and the aim of the present study is to describe the evaluation of this anatomical configuration using cone-beam computed tomography.

Virtual reality training simulator for tooth preparation techniques

  • Jung, HeeSuk;Kim, HyoJoon;Moon, SeongYong
    • Oral Biology Research
    • /
    • v.42 no.4
    • /
    • pp.235-240
    • /
    • 2018
  • Standard oral and maxillofacial three-dimensional model was developed with patients' medical data while virtual reality (VR) simulator was developed in conjunction with head mount display (HMD) and Haptic device. The objective of this study was to evaluate the preclinical use of a VR training simulator in tooth preparation practice. Eighty-nine dental students were trained how to operate the simulator. The participants were then given sufficient time on the simulator to practice dental preparation. The students experience and opinion was then taken in through filling of questionnaires. On average content received 1.8 points, anatomy had 2.5 points, 2.6 points for the applicability, and 2.0 for the usability. As for the detailed items scores, queries about the possible development of the simulator and the interest of the learning process through the simulator were the highest at 3.1 and 3.0 points, respectively. Question about the benefit of the HMD and the haptic device during the practice had 1.5 and 1.6 points, respectively. The average total score was 2.2 points. VR tooth preparation simulator in the field of clinical dental education has powerful potential in regard to realistic models, environments, vision, posture, and economical efficiency.

Finite Element Model based on Strain Tests for Predicting Bending Strength of Small Gears for Aircraft

  • Kim, Taehyung;Seok, Taehyeon;Seol, Jin-woon;Lee, Byung-ho;Kwon, Byung-gi;Choi, Jong-yoon
    • Journal of Aerospace System Engineering
    • /
    • v.14 no.6
    • /
    • pp.91-99
    • /
    • 2020
  • This study proposes a finite element (FE) model for predicting the bending strength of small gears used in electro-mechanical actuators for aircraft. First, a strain gauge was attached to the tooth root of test gear, and the strain was measured. Subsequently, the FE model was applied to calculate the strain of the test gear, and the modeled strain was compared with the experimental strain. The results confirmed that the FE strain was very close to the experimental strain and the FE model was valid. This FE model was extended to the bending strength analysis of several small gear tooth models. The bending strengths of all the tooth models were almost identical to the ISO theoretical bending strength. Finally, the FE model was validated and the reliability of the modeled bending strength was evaluated through the strain measurement experiment.