• Title/Summary/Keyword: Tool shoulder

Search Result 125, Processing Time 0.025 seconds

Evaluation of Effectiveness of Anatomical Rotation Change Image by Aid Tool in Shoulder MRArthrography (Shoulder MRArthography 검사 시 보조기구를 이용한 해부학적 회전 변화 영상에 대한 유용성 평가)

  • Kim, Hyeong-Gyun;Jung, Jae-Eun;Jung, Hong-Moon
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.4
    • /
    • pp.299-303
    • /
    • 2012
  • Shoulder MRArthrography was performed to get an accurate diagnosis about complex anatomical structure in shoulder joint. We carried out how the changes of anatomical rotations in shoulder joint could bring certain diagnosis effects on MRI images for various shoulder humerus positions; Neutral position, Internal rotation position and External rotation position. In addition, we prepared an aid tool in oder to maintain the right posture of a patient. This aid tool was made by adapting Modeling Design Program. By virtue of this aid, we obtained the following result. Shoulder MR Arthrography by the External rotation position for anatomical structure diagnosis was the most suitable in diagnostic evaluations of important anatomical structures in shoulder joint such as Biceps tendon, Supera-spiatus tendon, Sub-scapularis tendon, Labrum and Sub-acromial space.

A Case Report of PNF Strategy Applied ICF Tool on Upper Extremity Function for Patient Adhesive Capsulitis (유착성 관절낭염 환자의 상지 기능에 대한 ICF Tool을 적용한 PNF 중재전략의 증례보고)

  • Kang, Tae-Woo;Kim, Tae-Yoon
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.12 no.4
    • /
    • pp.19-28
    • /
    • 2017
  • PURPOSE: The purpose of this study was to describe the Proprioceptive Neuromuscular Facilitation (PNF) Intervention strategy applied International Classification of Functioning, Disability and Health (ICF) Tool about strength, range of motion, scapular stability, pain and function of shoulder for patients with adhesive capsulitis. METHODS: The data was collected by patient with adhesive capsulitis. The patient was a 50-year-old male diagnosed with right shoulder with adhesive capsulitis. We applied the PNF Intervention strategy applied ICF Tool to patient with adhesive capsulitis. PNF interventions were consisting of such as combination of isotonic and stabilizing reversal technique and various positions. PNF interventions were applied, such as those aiming at decreasing pain and disability and increasing range of motion and function for the four weeks. Parameters of result were collected for strength, range of motion, scapular stability, pain and function of shoulder using the hand held dynamometer, goniometer, lateral scapula slide test, and shoulder pain and disability index, respectively. RESULTS: Clinical benefits were observed the patient with adhesive capsulitis for strength, range of motion, scapular stability, pain, and function of shoulder. The patient with adhesive capsulitis improved strength, range of motion, scapular stability, pain, and function of shoulder. CONCLUSION: Patient reported improved strength, range of motion, scapular stability, pain, and function of shoulder after intervention.

An experiment of optimizing tools for Lap joint with 2tmm Aluminum alloy plate using FSW (2tmm AL-합금재의 겹침이음을 위한 교반용접의 실험적 연구)

  • 장석기;이돈출;김상진;전정일
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.153-160
    • /
    • 2002
  • This paper shows the possibility of performing Lap joint using the friction stir welding and the determination of tool's dimensions for FSW in Milling machine. This research also is reported on obtaining the tensile-shear strength, 9.319 ( kgf/mm$^{2}$) and the energy absorption, 2,682 (kgf-mm) under this experiment. The optimal tool's dimensions and method for Lap joint in 2tmm aluminum alloy plate using FSW is as follows; The diameter of shoulder and pin are 9 $\phi$mm and 3$\phi$mm, the length of pin is 3.6mm. The conditions of shoulder of tool is not pressed into original base metal.

  • PDF

Evaluation on Tensile Characteristics of Extruded Aluminum Panel Joints by Friction Stir Welding Parameters (마찰교반 용접변수에 따른 알루미늄 압출판재의 인장특성 평가)

  • Lim, Byung-Chul;Kim, Young-Moon;Kim, Won-Seop;Park, Sang-Heup
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.3
    • /
    • pp.614-618
    • /
    • 2018
  • The changes in the mechanical properties according to the width of the tool shoulder, rotation speed and moving speed in friction stir welding (FSW) are evaluated using Al 6061-T6. The results indicated that the tensile strength value increases with increasing rotation speed. The higher the moving speed of the tool shoulder, the lower the tensile strength, regardless of the tool type. A higher tensile strength value was generally obtained with a tool shoulder diameter of 12mm (TSD12) than with 8mm. When the moving and rotation speeds exceed a limiting value, a stabilization stage is reached, in which (the tool shoulder diameter?) no longer affects the material properties. At a tool shoulder diameter of 8mm (TSD8), the material properties are decreased and the mixture of material in the welding area is incomplete in comparison with the tool type of TSD12. The tensile strength value is decreased at a rotation speed of 1500 rpm. As a result, a rotation speed higher than the threshold value is needed in order for and the transition temperature to be reached, which allows the complete mixing of the material in the welding area.

Comparative Analysis of Pain Disorder Factors and Subjective Pain Reduction Effect after Functional Adjustment Procedure Therapy for Shoulder Pain Patients (직장인 어깨 통증 환자의 기능교정 치료 후 통증 장애 요인과 자각적 통증 감소 효과 비교분석)

  • Kim, Hee-Hyeon;Lim, Dong-Ho
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.15 no.4
    • /
    • pp.87-99
    • /
    • 2020
  • PURPOSE: This study examines the therapeutic effect of functional adjustment procedure therapy (FAPT), by comparatively analyzing behavioral disorders due to shoulder pain and subjective pain intensity subsequent to therapy, in patients with shoulder pain. METHODS: The intervention was performed on 48 employee patients with shoulder pain, Patients were administered 16 sessions of FAPT for 8 weeks, twice a week for 30 minutes per session. This study applied the neck pain and disability scale (NPDS) as a measurement tool, and used the questionnaire to measure subjective pain intensity to investigate the difference before and after administering FAPT to employee patients with shoulder pain. RESULTS: Statistically significant difference was obtained between the mean difference in shoulder pain disorder, before and after FAPT. Assessing gender and age differences in the reduction effect of shoulder pain, showed significant difference in 8 of the 10 factors examined. Finally, examining the difference in the effect of reducing subjective shoulder pain by gender and age, we observed that gender-based disability reduction was significant for all 12 factors examined. CONCLUSION: Taken together, the results of this study, validate the therapeutic efficacy of FAPT for patients with shoulder pain. We believe that this data will provide basic information to understand the health conditions and psychological variables of patients with shoulder pain.

Simple Radiographic Analysis of Chronic Shoulder Pain in Patients 50 Years and Older (만성 견관절 동통을 가진 50세 이상 환자의 단순 방사선 사진 분석)

  • Yoo Chong II;Kim Hui Taek;Eun II Soo
    • Clinics in Shoulder and Elbow
    • /
    • v.7 no.1
    • /
    • pp.14-22
    • /
    • 2004
  • Purpose: To evaluate a usefulness of the simple radiograph in the patients with chronic shoulder pain 50 years and older. Material and method: 1152 patients with chronic shoulder pain and 100 asymptomatic individuals were involved in this study. All patients were 50 years and older. We excluded patients who had a history of fracture or dislocation. Radiographic interpretation was performed on a shoulder AP view, an axillary view and a supraspinatus outlet view. For statistical analysis, a chi-square test was performed. A p value of <0.05 was considered statistically significant. Results: Abnormal radiologic findings were identified in 369(32%) out of 1152 patients with a shoulder pain: greater tuberosity sclerosis, acromial sclerosis, subacromial osteophytes are common abnormal radiologic findings. A rotator cuff tear or impingement syndrome was identified on a final diagnosis in 61(85.2%) out of the 76 patients with radiologic abnormalities in both greater tuberosity and acromion (p<0.05). Abnormal radiologic findings were identified in 18% of the asymptomatic individuals. Conclusion: Simple radiographic analysis is an important primary diagnostic tool in patients (50 years and old) with chronic shoulder pain.

Spot Friction Welding of 5J32 Al alloy (5J32 알루미늄 합금의 마찰 점용접)

  • Lee, Won-Bae;Lee, Chang-Yong;Yeon, Yun-Mo;Jeong, Seung-Bu
    • Proceedings of the KWS Conference
    • /
    • 2005.11a
    • /
    • pp.192-194
    • /
    • 2005
  • Joint strength of spot friction welded 5J32 Al alloy were investigated according to the tool shape and the tool penetration depth. General spot friction stir welding tool consists of a shoulder having bigger diameter and a threaded pin projected from the shoulder, which resulted in the generation of large up-lifting of upper plate around the weld nugget because of the deeper penetration and the severe stirring effect of threaded pin. Two kinds of welding tools without the threaded pin were used to avoid the distortion and improve the joint strength. One was a simple cylindrical shape and the other was cylindrical shape with small projection. Therefore, the process was named as spot friction welding comparing to spot friction stir welding because spot friction welding don't use a stirring effect. Using the cylindrical shape tool with small projection, the up-lifting of upper plate were avoided and joint strength were superior to that of the joint using simple cylindrical shape tool. At the 0.5mm of too penetration depth using cylindrical tool with small projection, nugget pull fracture mode can be observed and shear fracture mode were dominant at the rest conditions.

  • PDF

A Study on the Finite Element Analysis in Friction Stir Welding of Al Alloy (알루미늄 합금재의 마찰교반용접 유한요소해석에 관한 연구)

  • Lee, Dai Yeal;Park, Kyong Do;Kang, Dae Min
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.14 no.5
    • /
    • pp.81-87
    • /
    • 2015
  • In this paper, the finite element method was used for the flow and strength analysis of aluminum alloy under friction stir welding. The simulations were carried out using Sysweld s/w, and the modeling of the sheet was executed using Unigraphics NX6 s/w. The welding variables for the analysis were the shoulder diameter, rotating speed, and welding speed of the tool. Additionally, a three-way factorial design method was applied to confirm the effect of the welding variables on the flow and strength analysis with variance analysis. From these results, the rotating speed had the greatest influence on the maximum temperature, and the maximum temperature was $578.84{\pm}12.72$ at a confidence interval of 99%. The greater the rotating speed and shoulder diameter, the greater the difference between maximum and minimum temperature. Furthermore, the shoulder diameter had the largest influence on von Mises stress, and the von Mises stress was $184.54{\pm}12.62$ at a confidence interval of 99%. In addition to the increased shoulder diameter, welding speed, and rotating speed of the tool increased the von Mises stress.

An Experimental Study on Lap Joint using FSW with $2mm^t$ Aluminum Alloy Plate ($2mm^t$ 알루미늄합금재의 겹치기이음을 위한 마찰교반용접의 실험적 연구)

  • 장석기
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.27 no.6
    • /
    • pp.728-735
    • /
    • 2003
  • This paper shows the possibility of performing Lap joint using the friction stir welding with $2mm^t$ aluminum alloy plate and the determination of tool-dimensions for FSW in milling machine. This research also is reported on obtaining the tensile-shear strength, 91.3 (MPa) and the energy absorption, 26.3 (J) for Lap jointed specimen. The optimal tool-dimensions and method for Lap joint using FSW is as follows; each diameter of shoulder and pin is $9\phi(mm) and 3\phi(mm)$, the length of pin is 3.6(mm), Pressing the shoulder of tool into original base metal is not reasonable.

Comparison of Extracorporeal Shock Wave Therapy Versus Injection Therapy for Shoulder Disorders: A Systematic Review and Meta-Analysis of Randomized Controlled Trials

  • Dajeong Kim;Hyunjoong Kim
    • Physical Therapy Rehabilitation Science
    • /
    • v.12 no.1
    • /
    • pp.48-55
    • /
    • 2023
  • Objective: The purpose of this study is to compare the effects of extracorporeal shock wave therapy (ESWT) and injection therapy through qualitative and quantitative analysis by synthesizing randomized controlled trials (RCTs) conducted on patients with various shoulder diseases. Design: A systematic review and meta-analysis of randomized controlled trials Methods: This review conducted a literature search through international electronic databases in January 2023 to compare the effects of ESWT and injection therapy. Qualitative analysis was performed as a risk of bias tool, and quantitative analysis was synthesized with a random effect model to show the effect size as a standardized mean difference (SMD). Results: Five RCTs involving 298 individuals with shoulder disorders were included in this systematic review and meta-analysis. ESWT showed a moderate effect on pain (SMD=-0.44; 95% CI, -0.95 to 0.06) and a large effect on shoulder function (SMD =-0.81; 95% CI, -1.70 to 0.07) than injection therapy. A significant difference was found in the shoulder range of motion, showing a large effect size (SMD=1.50; 95% CI, 0.58 to 2.43). Conclusions: When considering treatment options for the management of patients complaining of shoulder disorders, it is appropriate to recommend ESWT first rather than injection therapy to increase the range of motion of the joint. In addition, ESWT is safe for pain control and shoulder function improvement, and a positive prognosis could be expected.