• 제목/요약/키워드: Tool insulation

검색결과 70건 처리시간 0.023초

코르크 삭마를 고려한 비행체 1D 온도해석 도구 개발 (A Development of One-dimensional Thermal Analysis Tool for Flight Vehicle with Cork Insulation)

  • 정태빈
    • 한국군사과학기술학회지
    • /
    • 제21권4호
    • /
    • pp.464-470
    • /
    • 2018
  • A development of one-dimensional thermal analysis tool is performed to estimate the thickness of cork insulation for flight vehicle. In the calculation of cork temperature, the cork density model, heat of ablation and pyrolysis gas enthalpy model were applied. The calculation for the two-layer model of cork and metal was performed by the tool and compared with the experimental data. The results for the two aerodynamic heating conditions were 17 % and -12 % different from the experimental data, respectively. The effect of mechanical ablation not included in the calculation can be expected as the cause of the difference. The temperature-density curve of cork which adjusted by experimental data was also presented.

3차원 정상상태 해석에 의한 공동주택 단열성능 평가 - TDR(온도상대비)을 중심으로 - (Insulation Performance Evaluation of Apartment Housing Bying a Three-Dimensional Steady State Simulation)

  • 최보혜;최경석;강재식;이승언;이용준
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.730-735
    • /
    • 2009
  • The purpose of this study is to consider improvement performance to prevent condensation and draw the optimum insulation design method for building using simulation tool. In this study, the three corners, weak part in condensation, were conducted by three-dimensional steady state simulation. From the results, it is required to strengthen insulation design, and it is founded that existing insulation system typically applied to most Korean apartment buildings has serious insulation defect that insulation is disconnected by structural components at the joints of wall-slab and wall-wall in envelope. So, it is considerate to need a concrete technology improvement.

  • PDF

XLPE 절연체에서의 열이력 추정 연구 (Study on the Estimation of Thermal History in XLPE Insulation)

  • 이상진;김영호;김영성;박완기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 D
    • /
    • pp.1575-1577
    • /
    • 1999
  • XLPE is widely used as a main insulation in EHV power cables, deeply connected with thermal stress. In this study, the thermal history of XLPE insulation was examined using DSC(Differential Scanning Calorimetry). The principle is on the basis of the phenomenon that crystal in polyethylene is rearranged as it is annealed near/below the melting temperature. From the result, it was possible to define accurate temperature which was really applied on the XLPE insulation and this method was assured as a useful tool in characterization of thermal history in XLPE cable insulation.

  • PDF

수력 발전기 권선에서의 운전중 부분방전 측정기법 (On-line partial discharge measurement techniques of hydro-generator windings)

  • 황동하;김진봉;김용주;박명수;김택수
    • 대한전기학회논문지
    • /
    • 제45권2호
    • /
    • pp.294-300
    • /
    • 1996
  • In hydro-generator, a groundwall insulation of stator windings gradually deteriorates due to mechanical, thermal, electrical and environmental stresses. These stresses combine to result in loose windings, delamination of the stator insulation and/or electrical tracking of the endwinding, all of which can lead to stator insulation failures. Conventionally, off-line tests such as partial discharge measurement, DC/AC current and .DELTA.tan.delta. tests has been used for estimation of winding condition. However, off-line test requires large power supply and generator outage. In addition, major cause of insulation problems such as loose wedges and slot dischages may not be found with off-line diagnoses. This paper introduces the on-line partial discharge measurement techniques using frequency spectrum analyzer(FSA) for the generator stator windings. The experimental results from the UIAM #1 hydro-generator confirms a optimistic application of on-line generator diagnosis method as a reliable tool for evaluation of winding condition.

  • PDF

적외선 열화상을 이용한 공동주택 단열성능 평가 : TDR(온도차비율)을 중심으로 (Thermal Performance Evaluation of Apartment Housing Using Infra-red Camera)

  • 최경석;손장열
    • 설비공학논문집
    • /
    • 제22권6호
    • /
    • pp.404-412
    • /
    • 2010
  • The purpose of this study is to accomplished an in-site evaluation method for existing building insulation status using Infra-red camera and to consider improvement performance to prevent condensation and draw the optimum insulation design method for building using simulation tool. The research contents of this study are to evaluate validity and suitability of building insulation defect survey using Infra-red camera for apartment housing with temperature and heat flow pattern analyze method. Based on this research, the three corners, weak part in condensation, were selected in apartment building and conducted simulation by three-dimensional steady state. From the results, it is required to strengthen insulation design, and it is founded that existing insulation system typically applied to most Korean apartment housings have serious insulation defect that insulation is disconnected by structural components at the joints of wall-slab and wall-wall in envelope. Thus, it is considerate to need a concrete technology improvement.

간이 차음시험장치(APAMAT II)와 잔향실 차음성능의 비교 (Comparison of Sound Insulation Performance between a Simplified Test Apparatus(APAMAT II) and the Reverberation Chamber)

  • 강현주;김봉기;김현실;이경민
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.174-177
    • /
    • 2003
  • Comparisons of measuring apparatus for sound insulation are made between a reverberation chamber and a simplified test apparatus(APAMAT II) that is used to measure sound insulation performance of inner panels for automobiles. Also, theoretical prediction by using sandwich model are made in order to compare it with experiments and to consequently provide a design tool. Comparative results show that steel ball excitation in APAMAT II has a serious problem with sound insulation performance at the low frequency region, while speaker excitation gives a good agreements with theoretical prediction.

  • PDF

Effects of Dental Sound Insulation System on Stress and Dental Fear Reduction in Pediatric Patients

  • Sangkyu Han;Jaeho Lee;Ko Eun Lee;Taeyang Lee;Wonse Park;Je Seon Song
    • 대한소아치과학회지
    • /
    • 제51권4호
    • /
    • pp.380-391
    • /
    • 2024
  • This study aimed to assess the effectiveness of dental sound insulation in alleviating stress and fear during dental scaling in pediatric patients. It also examined the influence of a noise-canceling application on dentist-patient communication and convenience of dental procedures. This study included 60 children and adolescents aged 7 - 16 years between April 2022 and March 2023. All participants underwent dental plaque control using an ultrasonic scaler on the maxilla first, followed by plaque control on the mandible. Dental sound insulation with active noise canceling was randomly applied to either the maxilla or mandible. Findings revealed that the stress index was significantly reduced when the application was used, with a score of 5.85 compared to 8.43 without it (p < 0.0001). Similarly, the dental fear score was significantly reduced to 1.17 with the application, as opposed to 2.97 without it (p < 0.0001). The dental sound insulation did not affect the communication between dentists and patients or the convenience of treatment. This study demonstrated that active noise canceling during pediatric dental care significantly reduced stress and fear, suggesting that it could be a valuable behavior guidance tool, particularly for children who find dental visits challenging.

Recovery Voltage Measurements of Oil-immersed Transformer

  • Li, Ming-Hua;Dong, Ming;Qu, Yan-Ming;Yan, Zhang
    • Transactions on Electrical and Electronic Materials
    • /
    • 제7권5호
    • /
    • pp.230-234
    • /
    • 2006
  • One of the methods currently being investigated as a possible non-intrusive diagnostic tool for condition monitoring of power transformer and cable is the recovery voltage measurement, which will be improving the ability to detect the content of water concentration and the ageing process in the insulation system and may thus be an indicator of insulation quality and its ageing status. The polarization phenomenon was studied using RVM with oil-paper samples. In order to interpret its mechanism, the Extended Debye model was introduced. With different circuit parameters, various simulation results were gotten. Furthermore, with the test samples of different ageing condition, measurements are accomplished in the lab. On the basis of this experiment as well as theoretical analysis, correlations between polarizations and ageing were analyzed.

액체질소를 사용하는 초전도 고전압 전력기기의 절연 특성 연구 (Analytical and Experimental studies on Dielectric Characteristics of High Voltage Superconducting Machines in Liquid Nitrogen)

  • 나진배;고태국;강형구;석복렬;김태중
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제13권1호
    • /
    • pp.46-50
    • /
    • 2011
  • The electrical insulation design of high voltage superconducting fault current limiters (SFCLs) should be confirmed to be applied for the stabilization of the power grid. This paper describes numerical analysis and AC dielectric experiments for developing high voltage SFCLs. The electric field distributions between applied high voltage part and ground were calculated by finite element method (FEM) simulation tool and AC criterion of liquid nitrogen at 200 kPa was calculated from correlation between the field utilization factor and FEM simulation results. This paper deals with ceonceptual insulation design of a 154 kV class single-phase no-inductively wound solenoid type SFCL which was focused on gap distance between the cryostat and superconducting coils. Furthermore, the shield ring effect was confirmed to reduce maximum electric field at applied high voltage part.