• Title/Summary/Keyword: Tool Were

Search Result 11,372, Processing Time 0.036 seconds

Cutting Performance of TiAlN coated WC Insert Tip (TiAlN을 코팅한 WC공구의 절삭성능에 관한 연구)

  • 김형자;최현철;이규용
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2001.06a
    • /
    • pp.281-286
    • /
    • 2001
  • TiAIN was deposited onto ISO P2O Cutting Insert Tip substrate by FVAS at the substrate temperature of 80$^{\circ}C$. Cutting and wear test have been performed with TiAIN coated and uncoated WC cutting tools, respectively. Uncoated WC cutting tool has been tested under similar cutting condition for comparison. Cutting force and tool wear of coated and uncoated carbide cutting tools were investigated by cutting length. In cutting test, cutting force of the coated insert tip was larger than the uncoated insert tip by tool wear. Configuration and wear of the coated tool were more stable and resistant than the uncoated. In tool life by the tool wear, the coated cutting tool life was rather longer than the uncoated when tested at high speed (V=250 m/min) than low speed (V=200 m/min), Cutting force, tool wear and life were analysised by tool dynamometer amp(3ch) and oscilloscope.

  • PDF

Fracture Characteristics of Cutting Tools in Machining of Hardened Alloy Steel (열처리한 합금공구강의 절삭에서 공구파손의 특성)

  • Noh, S.L.;An, S.O.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.7 no.3
    • /
    • pp.199-205
    • /
    • 1994
  • The fracture characteristics and tool life of ceramics and WC, CBN cutting tool when turning heat treated steel STD11($H_RC$ 60) were investigated experimentally to clarify the machinability and optimum tool materials in cutting of difficult-to-cut material with high hardness. Forthermore, the behaviors of the tool wear and failure were examined with regard to cutting force. The hardened steel wore the cutting tool edge rapidily and increased the cutting forces, especially radial force. The tool was worn by the abrasive action. Flank Weat of $Al_2O_3-TiC$ ceramic and WC tool become relatively large and CBN & $Al_2O_3$, ceramic tool had a long life among the tool materials tested. The tool fracture patterns were just like minor cutting wear, flank wear, crater wear, notch wear, chipping. Flank wear rate was accelerated by occurrence of chipping. During the proceeding of machining, it was possible to foresee the catastrophic fracture of tool by abrupt increase of radial force.

  • PDF

Development of and Evaluation Tool for the Quality of Patient Care in Musculo-skeletal Disorder (${\cdot}$ 골격장애 환자의 간호질 평가 도구 개발)

  • Choi, Soon-Ook;Kim, Moon-Sil
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.1 no.2
    • /
    • pp.338-348
    • /
    • 1995
  • We need to continuously evaluate for nursing quality and the outcome to reflect nursing, to repair and improve of nursing. The first problem for nursing quality improvement is development of evaluation tool for the quality of nursing care. We need a system for quality assurance evaluation that is, development and framework of evaluation tool for nursing care quality. The purpose of this study was attempted to develop an evaluation tool for the quality of nursing care in musculoskeletal disorder patients. The approach method of nursing quality for the development of the tool in this study was process evaluation framework. The study were devided dvelopment process and reliability, validity verification process. The subjects of development process of this tool are three nursing export groups, and the subject of reliability, validity verification process are 20 samples of two university hospital in seoul, who were within discharge 3 months after admission treatment in musculo-skeletal disorder. Data for this study was collected from March 10 to April 13, 1995. The development process of the tool were as follows : 1. Make preliminary list of the tool by focal group were constituted 12 clinical nurses. 2. Modify and add preliminary list by 4 nursing expert panel. 3. Calculate content validity of the tool by 25 nursing expert panel of judge. 4. Verify reliability and validity of the tool. 5. Finalize an evaluation tool for the quality of the nursing care in musculo-skeletal disorder. The results of this study were as follows : 1) Development an evaluation tool for the quality of nursing care in musculo-skeletal disorder. (1) The evalution tool of this study was developed 5 standards, 33 criterias and 133 indicators. (2) 5 standards were divided according to Nursing Process. from standard 1 to standard 5, involved criterias were each 6(18%), 3(9%), 3(9%), 15(46%), 6(18%). 2) Verify reliability and validity of the tool. (1) Score of adequate degree for content validity of 33 criterias and 133 indicators were every average 2.82. (2) Inter-rater reliabilities(consentaneity score) of the tool by pearson correlation coefficient between three raters were : r=.7506, r=.8934, r=.6695. and Inter-rater reliabilities by single-facet crossed design were : r=.7464. (3) The alpha coefficient relating to internal consistency was .8524 over all 30 items of 33 criterias of developed tool. (4) Score of the quality of nursing care following to generaal characteristics of this study subjects were stastically significant differences according to educational level (F=2.93, p=.029)and diagnosing classification (F=2.50, p=.042). Through this study, I'm sure that the developed tool for the quality of patient care in musculo-skeletal disorder will show the way of more improvement of the quality of nursing care and effective nursing interventions.

  • PDF

A Study on Micro Tool Deflection in Micro Endmilling Process (마이크로 엔드밀링 시 공구 변형에 관한 연구)

  • Kim, G.H.;Yoon, G.S.;Heo, Y.M.;Jung, W.C.;Cho, M.W.
    • Transactions of Materials Processing
    • /
    • v.15 no.9 s.90
    • /
    • pp.654-659
    • /
    • 2006
  • In this paper, the real shapes of micro tool deflection were observed. In micro endmilling process, micro tool deflection generates very serious problems in contrast to macro tool deflection. For analyzing the micro tool deflection, the trend of micro tool deflection was observed using real captured images in this paper. To get the real images of micro tool deflection, micro slot cutting processes were executed under cutting volume using micro endmill($Dia.\;200{\mu}m$) and real images of tool deflection were obtained during cutting processing by high-speed camera. Finally, the extent of tool deflection was calculated by the deflection angle according to cutting volume.

저순도 알루미나 세라믹 가소결재의 피삭성

  • 이재우
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.04b
    • /
    • pp.33-38
    • /
    • 1995
  • In this study, unsistered, pre-sintered and sintered low purity alumina ceramics were machined with various tools to clarify the machniability, the optimum tool materials and the optimum tool materials and the optimum cutting conditions. The maon conclusions obtained were as follows. (1) Machined withalloy steel tool, the machinabilty of te pre-sintered ceramics becomes better with the decrease of pre-sintering temperature, but that of unsintered ceramics(white body) was extremely poor. (2) In the case of carbide tool K01, the tool life in machining white body was the longest, and the machinabilty of pre-sintered ceramics becomes poorer with the increase of the pre-sintering temperature. (3) In the case of ceramic tool, the 10000-1100 .deg. C pre-sintered ceramics showed te best machinability within a certain cutting speed range. So far as dry machining, the above combination and conditions showed the highest productivity. (4) When the pre-sintered ceramics were wet machined withsintered diamond tool, the tool life becomes extremelylong, and higher cutting speed can be can be used than in the case offull-sintered ceramics. The productivity of wet cutting is much higher than that ofdry cutting.

  • PDF

Machinability of Pre-sintered Alumina Ceramics (알루미나 세라믹 가소결재의 피삭성 -다이아몬드 및 CBN공구의 절삭 성능-)

  • 김성청
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1996.03a
    • /
    • pp.41-46
    • /
    • 1996
  • In this study, unsintered and pre-sintered low purity alumina ceramics were machined with various tools to clarify the machinability, optimum tool materials and optimum cutting conditions. The main conclusions obtained were as follows. (1)In the case of dry cutting, the sintered diamond and natural diamond tools exhibit better performance in machining of the ceramic pre-sintered at lower temperature, and the tool lives of both tools in machining the ceramics pre-sintered at high temperature becomes extremely short. (2)The performance of CBN tool becomes better in dry machining of the ceramics pre-sintered at higher temperature. (3)When the pre-sintered ceramics were wet machined with sintered diamond, the tool life becomes considerably long, and higher cutting speed can be used than in the case of the CBN and ceramic tools, the tool lives becomes shorter at wet cutting than at dry cutting, especially exhibiting extremely short tool life in wet cutting with ceramic tool.

  • PDF

Machining Precision according to the Change of Feedrate when Ball Endmilling of Semisphere Shape (볼 엔드밀에 의한 반구 가공시 이송속도 변화에 따른 가공정밀도)

  • 임채열;우정윤;김종업;왕덕현;김원일
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.05a
    • /
    • pp.930-933
    • /
    • 2000
  • Experimental study was conducted for finding the characteristics of machining precision according to the change of feedrate when ball endmilling of semisphere shape. The values of tool deflection and cutting force were measured simultaneously by the systems of eddy-current sensor and dynamometer. The machining precision was analyzed by roundness values, which were deeply relating with tool deflection and forces. the roundness was decreased in down-milling than in up-milling for each feedrate. As the cutting edge is moved to radius direction on the tool path, the tool deflection and the cutting force were seemed to be decreased. As the tool path was moved downward, the values of roundness, cutting force and tool deflection were obtained better ones. When compared the values of roundness, cutting force and tool deflection for different feedrate, the best machining accuracy was obtained at feed rate of 90mm/min in down-milling.

  • PDF

Development of the Korean version of ICF e-Learning tool

  • Lee, HaeJung;Song, JuMin
    • The Journal of Korean Physical Therapy
    • /
    • v.31 no.2
    • /
    • pp.88-93
    • /
    • 2019
  • Purpose: The aim of the study was to develop a Korean version of an ICF e-Learning tool (KICF e-Learning tool). Methods: The process of translation and adaptation of the ICF e-Learning tool was followed: two translators developed the Korean versions independently, and a consensus version of the translation was then produced. An expert committee, which was composed of five experts from physiotherapy, occupational therapy, speech pathology, and social welfare, reviewed the consensus Korean version to make a beta version of the tool. A field test was conducted to determine if the Korean version of the tool was easy to understand and suitable to use in ICF learning. Feedback from the field test were used for the final adaptation of the KICF e-Learning tool. Results: One-hundred and twenty-six volunteers (40 males and 76 females) were invited to examine the KICF e-Learning tool. The participants reported various levels of ICF knowledge from none to very good. Forty-eight participants reported no knowledge of ICF. The majority of participants (n=84) reported that Korean terms or expression in the tool were easy to understand and one-hundred fourteen participants would recommend the tool to another person. The Korean cases would be helpful for a Korean audience to study the ICF using the tool. Conclusion: The KICF e-Learning tool was developed and is ready for use by the public for the consistency of ICF education. On the other hand, development of an advanced module will be needed.

Development of An Evaluation Tool for the Quality of Patient Care Chonic Renal Failure (만성 신부전 환자간호의 질평가 도구개발)

  • Yang, Young-Ock;Kim, Moon-Sil
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.2 no.1
    • /
    • pp.57-72
    • /
    • 1996
  • Provision of better nursing care to patients is a difficult but important task. The first problem for nursing quality improvement is development of evaluation tool for the quality of nursing care. This study tries to develop a patient care tool for patients with chronic renal failure. This study as a procedural evaluation of patient care, tries to show what, how, at what order to provide care to patients with chronic renal failure. This study is divided into process of development of tool, its reliability and validity. Among process of development of tool is focal group, small expert group and expert evaluation group. To develop approprieteness of tool, nurses working is four major hospitals is Seoul were selected. To evaluate the credibility of subjects, 19 patient who were hospitalized and discharged within 3 months were selected. The period for collecting data for reliability and valiability evaluation was between Sept. 20 to Oct. 18, 1995. The development process of this study is as follows ; 1. Make preliminary list of the tool by focal group consisting of 8 clinical nurses. 2. Modify and add preliminary list by 4 expert nursing panel. 3. Calculate content validity of the tool by 23 nursing expert panel of judge. 4. Verity relability and validity of the tool. 5. Finalize an evaluation tool for the quality of nursing care in chronic renal failure patient. The result of this study were as follows ; 1. Development of evaluation tool for the quality of nursing care in chronic renal failure. 1) The evaluation of this study was developed 5 standards, 28 criteria. and 130 indicators 2) Nursing care evaluation scores for chronic renal failure patients were average 68.8. 2. Verity reliability and validity of the tool. 1) 5 standards were divided into 4 point scale and according to 28 creteria, indicators of standard were 3.72 and of criteria were 3.77 2) Inter - rater reliability (consentaneity score) of the tool by pearson correlation coefficient betwwen rates were r= .72, r= .75 and interreliabilities by single - facet crossed design were r= .96. 3) The alpha coeffecient relating to internal consistency was .7259 over 27 items of 28 criterias of developed tool. Through this study, I'm sure that the developed tool for the quality of patient care in chronic-renal failure patient will show the way of more improvement of the quality of nursing care and effective nursing intervention.

  • PDF

Comparison of Machinability Between PCD Tool and SCD Tool for Large Area Mirror Surface Machining Using Multi-tool by Planer (평삭공정에서 경면가공을 위한 단결정 및 다결정 다이아몬드 다중공구의 가공성 평가)

  • Kim, Chang-Eui;Choi, Hwan-Jin;Jeon, Eun-Chae;Je, Tae-Jin;Kang, Myung-Chang
    • Journal of Powder Materials
    • /
    • v.20 no.4
    • /
    • pp.297-301
    • /
    • 2013
  • Mirror surface machining for large area flattening in the display field has a problem such as a tool wear and a increase in machining time due to large area machining. It should be studied to decrease machining time and tool wear. In this paper, multi-tool machining method using a PCD tool and a SCD tool was applied in order to decrease machining time and tool wear. Machining characteristics (cutting force, machined surface and surface roughness) of PCD tool and SCD tool were evaluated in order to apply PCD tool to flattening machining. Based on basic experiments, the PCD/SCD multi-tool method and the SCD single-tool method were compared through surface roughness and machining time for appllying large area mold machining.