• Title/Summary/Keyword: Tool Electrode Surface

Search Result 69, Processing Time 0.028 seconds

Measuring System of Visual Evoked Potential (VEP) in Mice using BioPAC Modules (BioPAC 모듈을 이용한 마우스 시각유발전위 측정 시스템 확립)

  • Lee, Wang Woo;Ahn, Jung Ryul;Goo, Yong Sook
    • Journal of Biomedical Engineering Research
    • /
    • v.38 no.1
    • /
    • pp.16-24
    • /
    • 2017
  • For the development of feasible retinal prosthesis, one of the important elements is acquiring proper judging tool if electrical stimulus leads to patient's visual perception. If evoked potential to electrical stimulus is recorded in primary visual (V1) cortex, it means that the stimulus effectively evokes visual perception. Therefore, in this study, we established VEP recording system on V1 cortex using BioPAC modules as the judging tool. And the measuring system was evaluated by recording VEP of mice. After anesthesia, normal mice (C57BL/6J strain; n = 6) were secured to stereotaxic apparatus (Harvard Apparatus, USA). For the recording of VEP, the stainless steel needle electrode (impedance: $2-5k{\Omega}$) was positioned on the surface of the cortex through the burr hole at 2.5 mm lateral and 4.6 mm caudal to bregma. DA 100C and EEG 100C BioPAC modules were used for the trigger signal and VEP recording, respectively. When left eye was blocked by black cover and right eye was stimulated by flash light using HMsERG (RetVet Corp, USA), VEP response at left V1 cortex was detected, but there was no response at right V1 cortex. Amplitudes and latencies of P2, N3 peaks of VEP recording varied according to the depths of the electrodes on V1 cortex. From the surface upto $600{\mu}m$ depth, amplitudes of P2 and N3 increased, while deeper than $600{\mu}m$, those amplitudes decreased. The deeper the insertion depth of the electrode, the latency of N1 peaks tends to be delayed. However, there was no statistically significant difference among the latencies of P2 and N3 peaks (P > 0.05, ANOVA). Our VEP recording data such as the insertion depth and the latency and amplitudes of peaks might be used as guidelines for electrically-evoked potential (EEP) recording experiment in near future.

Evaluation of Machining Characteristics through Wire-Cut EDM of Brass and SKD 11 (황동과 금형강의 와이어 컷 방전가공을 통한 가공특성 평가)

  • 김정석
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.6 no.4
    • /
    • pp.130-137
    • /
    • 1997
  • The demand for wire-cut EDM is increasing rapidly in the die and tool making industry. In this study machining characteristics such as machining rate, surface roughness, hand drum form and hardness of machined material are investigated experimentally under the conditions varing pulse on time, pulse off time, peak voltage, wire tension after fixing other conditions in SKD 11 and brass and brass workpiece. It was found that various operating conditions had significant influences on machining characteristics. But the hardness of workpiece was uneffected by operating conditions. Also it was obtained experimentally that brass workpeice had better machinability than SKD 11 one.dition according to the current(Ip) in an electric spark machine : 1) Electrode is utilized Cu and Graphite. 2) Work piece is used the material of carbon steel. The condition of experiment is : 1) Current is varied 0.7(A) to 50(A) and the time of electric discharging to work piece in each time is 30(min) to 60(min). 2) After the upper side of work piece was measured in radius(5$\mu$m) of stylus analyzed the surface roughness to ade the table and graph of Rmax by yielding data. 3) Electro wear ratio is : \circled1Cooper was measured ex-machining and post-machining by the electronic balance. \circled2The ex-machining of graphite measured by it, the post-machining was found the data from volume $\times$specific gravity and analyzed to made its table and graph on ground the data. 4) In order to keep the accuracy of voltage affected to the work piece was equipped with the A.V. R and the memory scope was sticked to the electric spark machine. 5) In order to preserve the precision of current, to get rid of the noise occured by internal resistance of electric spark machine and to force injecting for the discharge fluid , it made the fixed table for a work piece to minimize the work error by means of one's failure during the electric discharging.

  • PDF

Effects of Draw-In Bridge Exercise with Taping or Visual Feedback on Abdominal Muscle Activity (테이핑 또는 시각적 피드백을 병행한 드로우-인 교각운동이 복부 근활성도에 미치는 영향)

  • Won-Sik Bae;Hwa-Gyeong Lee
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.12 no.2
    • /
    • pp.177-186
    • /
    • 2024
  • Purpose : The purpose of this study was to use oral instruction and taping to induce abdominal draw-in in the previous study, but there is a lack of research on the comparison of effects. Therefore, in this study, we would like to study how the effect of oral instruction, taping, and no feedback can affect muscle activity when performing abdominal draw-in pier exercises. Methods : Before the experiment, group A trained piers and applied only draw-in piers, group B applied taping feedback, and group C were divided into three groups per week for six weeks, and three sets of contractions for five seconds per group were performed five times, and a minute break was provided between each exercise. As a measurement tool, a wireless surface electromyography (EMG) was used to measure surface electromyography (Telemyo-DTS, NORAXON, USA) that derives a synthetic unit of muscle using a surface electrode. For statistical processing of data, the analysis is performed using the SPSS/PC Version 25.0 statistical program for Windows, and the statistical significance level is a=.05 Results : First, the duration was somewhat shorter in order to more accurately compare the muscle activity of the core muscles. Therefore, future research needs to be research that can be exercises with precise biofeedback and taping applied over a longer period of time. Secondly, it is believed that there is no significant difference, since the subjects were studied in healthy young adult men and women, not patients. Thirdly, they could not control the daily life of the subjects. Through future research, it is necessary to analyze the correlation between muscle activity and abdominal muscle thickness by adding ultrasound in addition to muscle activity in various age groups. Conclusion : During draw-in bridge exercise according to feedback, the muscle activity of the back muscle increased, and there was no significant difference in the muscle activity of the back muscle according to each feedback. Therefore, both the feedback applied during the draw-in pier exercise and the control group are effective in changing the thickness of the abdominal muscles.

Durability Evaluation of ER Fluids in Hydraulic Control Systems (유압제어시스템 적용을 위한 ER 밸브의 내구성 평가)

  • Kim, Do-Tae;Jang, Sung-Cheol
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.16 no.2
    • /
    • pp.100-105
    • /
    • 2007
  • Electro-rheological(ER) fluid and valve are fabricated and evaluated experimentally in its durability to utilize the hydraulic control systems for long term operation. The two-ports ER valve used in the experiment consist of twelve parallel multi-layer electrodes and provide a restriction to the passage of ER fluid because of the viscous pressure drop and a component induced by the electric field. The durability test of ER valve are performed by measuring the surface roughness of electrodes with variation of an electric field strength and test time(1000 or 1800min.). Also, the shear stress and shear rate are measured to evaluate the durability of ER fluid as function of time. After durability test, ER shear stress increases approximately proportional to the shear rate with applied electric field intensity, In the ER valve, the center line average height roughness(Ra) of copper electrode increases about 1.56 times and ten-point median height roughness(Rz) increases about 2.2 times after the durability test. An understanding of these durability is essential to predicting the service life of ER fluid and valves.

Microfabrication by Localized Electrochemical Deposition Using Ultra Short Pulses (초단펄스 응용 전해증착에 의한 마이크로 구조물 제작)

  • 박정우;류시형;주종남
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.11
    • /
    • pp.186-194
    • /
    • 2004
  • In this research, microfabrication technique using localized electrochemical deposition (LECD) with ultra short pulses is presented. Electric field is localized near the tool tip end region by applying a few hundreds of nano second pulses. Pt-Ir tip is used as a counter electrode and copper is deposited on the copper substrate in 0.5 M CuSO$_4$ and 0.5 M H$_2$SO$_4$ electrolyte. The effectiveness of this technique is verified by comparison with LECD using DC voltage. The deposition characteristics such as size, shape, surface, and structural density according to applied voltage and pulse duration are investigated. The proper condition is selected from the results of the experiments. Micro columns less than 10 $\mu$m in diameter are fabricated using this technique. The real 3D micro structures such as micro pattern and micro spring can be fabricated by this method. It is suggested that presented method can be used as an easy and inexpensive method for fabrication of microstructure with complex shape.

A study for its Characteristics with Electric Variation in an Electrical Discharge Machining (방전가공에서 전기적 변화가 갖는 방전 특성에 관한 연구)

  • 신근하
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1996.03a
    • /
    • pp.132-136
    • /
    • 1996
  • A Study is a experiment which is figure out to aptimum discharge cutting condition of the surfaceroughness, electric discharging speed and electro wear ratio with Ton Toff and V(voltage) as an input condition according to the current(Ip) in an electric spark machine ; 1)Electrode is utilized Cu(coper) and Graphite. 2)Work piece is used the material of carbon steel. The condition of experiment is; 1)Current is varied 0.7(A) to 50(A). 2)Pulse time(Ton) is varied 3($\mu$s) to 240($\mu$s) and also Toff is varied 7($\mu$s) to 20($\mu$s). 3)The time of electric discharging to work piece in each time is 30(min) to 60(min) 4)After the upper side of work piece was measured in radius (5${\mu}{\textrm}{m}$) of syulus analyzed the surface roughness to made the table and graph of Rmax by yielding data. 5)Electro wear ratio is; \circled1Coper was measured cx-machining and post machining but the electronic baiance. \circled2The ex-machining of graphite measured by it, the post-machining was found the data from volume specific gravity and analyzed to made its table and graph on ground the data 6)In order to keep the accuracy of voltage affected to the work piece was equipped with the A.V.R(Automatic Voltage Regulator). 7)The memory scope was sticked to the electric spark machine. 8)In order to preserve the precision of current, to get rid of the noise occured by internal resistance of electric spark machine and to force injecting for the discharge fluid, it made the fixed table for a work piece to minimize the work error by means of one's failure during the electric discharging According to above results, the surface roughness by the variation of electrodw and current was analyzed to compare KS(Korea Standards) It was decided the optimum condition of electric discharge cutting through analyzing the effect of electric discharge speed and electro wear ratio.

  • PDF

Numerical Simulation of Normal Logging Measurements in the Proximity of Earth Surface (지표 부근에서의 노멀전기검층 수치 모델링)

  • Nam, Myung-Jin;Hwang, Se-Ho
    • Economic and Environmental Geology
    • /
    • v.43 no.3
    • /
    • pp.259-267
    • /
    • 2010
  • Resistivity logging instruments were designed to measure electrical resistivity of formation, which can be directly interpreted to provide water-saturation profile. Short and long normal logging measurements are made under groundwater level. In some investigation sites, groundwater level reaches to a depth of a few meters. It has come to attention that the proximity of groundwater level might distort short and long normal logging readings, when the measurements are made near groundwater level, owing to the proximity of an insulating air. This study investigates the effects of the proximity of groundwater level (and also the proximity of earth surface) on the normal by simulating normal logging measurements near groundwater level. In the simulation, we consider all the details of real logging situation, i.e., the presence of wellbore, the tool mandrel with current and potential electrodes, and currentreturn and reference-potential electrodes. We also model the air to include the earth’'s surface in the simulation rather than the customary choice of imposing a boundary condition. To obtain apparent resistivity, we compute the voltage, i.e., potential difference between monitoring and reference electrodes. For the simulation, we use a twodimensional, goal-oriented and high-order self-adaptive hp finite element refinement strategy (h denotes the element size and p the polynomial order of approximation within each element) to obtain accurate simulation results. Numerical results indicate that distortion on the normal logging is greater when the reference potential electrode is closer to the borehole and distortions on long normal logging are larger than those on short normal logging.

Effect of Applied Pressure Differences to Abdomen on Lumbar and Abdominal Muscle Activation During Upper Limb Exercise (상지운동 동안 복부에 적용된 압력 차이가 요부와 복부 근육 활성도에 미치는 영향)

  • Ko, Eun-Hye;Yoon, Hye-Sun;Cynn, Heon-Seock;Lee, Kang-Sung
    • Journal of Korean Physical Therapy Science
    • /
    • v.10 no.2
    • /
    • pp.96-103
    • /
    • 2003
  • The purpose of this study was to assess the effect of applied pressure to abdomen on lumbar and abdominal muscle activation during upper limb exercise. The experimental group consisted of twenty-seven healthy male subjects (mean age=$22.40{\pm}2.19years$, mean height=$175.30{\pm}2.19cm$, mean weight= $67.67{\pm}7.44kg$, RM=$8.43{\pm}2.76kg$). In each different pressure condition (OmmHg, 30mmHg, 70mmHg, 100mmHg), upper limb exercise was performed in total of 10 trials with 10 RM dumb-bell exercise. Lumbar and abdominal muscle activity was measured using surface bipolar electrode electromyography(EMG). EMG activity was measured from upper rectus abdominis, external oblique abdominis, internal oblique abdominis, and elector spinae. The raw EMG signal was processed into the root mean square(RMS). All RMS EMG data were normalized and express as a percentage of the EMG(%EMG). Collected data were statistically analyzed by SPSS/PC Ver 10.0 using two-way analysis of variance for repeated measures($4{\pm}3$) and Bonferroni post hoc, test. Lumbar and abdominal muscle activation was significantly increased when 100 mmHg was applied(p<.05). Upper rectus abdominis activation was significantly increased compared as other muscles activation(p<.05). However, there were no interaction between pressure and muscles(p>.05). The findings of this study can be used as a fundamental data when lumbar orthosis is applied and external pressure can be used as a therapeutic tool.

  • PDF

PCA­based Waveform Classification of Rabbit Retinal Ganglion Cell Activity (주성분분석을 이용한 토끼 망막 신경절세포의 활동전위 파형 분류)

  • 진계환;조현숙;이태수;구용숙
    • Progress in Medical Physics
    • /
    • v.14 no.4
    • /
    • pp.211-217
    • /
    • 2003
  • The Principal component analysis (PCA) is a well-known data analysis method that is useful in linear feature extraction and data compression. The PCA is a linear transformation that applies an orthogonal rotation to the original data, so as to maximize the retained variance. PCA is a classical technique for obtaining an optimal overall mapping of linearly dependent patterns of correlation between variables (e.g. neurons). PCA provides, in the mean-squared error sense, an optimal linear mapping of the signals which are spread across a group of variables. These signals are concentrated into the first few components, while the noise, i.e. variance which is uncorrelated across variables, is sequestered in the remaining components. PCA has been used extensively to resolve temporal patterns in neurophysiological recordings. Because the retinal signal is stochastic process, PCA can be used to identify the retinal spikes. With excised rabbit eye, retina was isolated. A piece of retina was attached with the ganglion cell side to the surface of the microelectrode array (MEA). The MEA consisted of glass plate with 60 substrate integrated and insulated golden connection lanes terminating in an 8${\times}$8 array (spacing 200 $\mu$m, electrode diameter 30 $\mu$m) in the center of the plate. The MEA 60 system was used for the recording of retinal ganglion cell activity. The action potentials of each channel were sorted by off­line analysis tool. Spikes were detected with a threshold criterion and sorted according to their principal component composition. The first (PC1) and second principal component values (PC2) were calculated using all the waveforms of the each channel and all n time points in the waveform, where several clusters could be separated clearly in two dimension. We verified that PCA-based waveform detection was effective as an initial approach for spike sorting method.

  • PDF