• Title/Summary/Keyword: Tongue bulb

Search Result 3, Processing Time 0.017 seconds

Size and Retention of Tongue Bulb for Tongue Retaining Device (혀 유지구의 크기와 유지력 평가)

  • Park, Nam-Seon;Lee, Ki-Ho;Kim, Mee-Eun;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.32 no.3
    • /
    • pp.283-292
    • /
    • 2007
  • In several treatment modalities for snoring and obstructive sleep apnea (OSA), oral appliances mainly including mandibular advancement appliance (MAA) and tongue retaining device (TRD) are recognized as a non-invasive, reversible alternative with favorable results. Tongue bulb is a major component of TRD which prevents the tongue from approaching the posterior wall of the pharynx and can be combined with MAA. Determination of tongue bulb size for the patient is important for therapeutic effect, but frequently needs time-consuming work. For effective fabrication and standardization of tongue bulbs, this study aimed to categorize tongue bulb size for healthy young men and to examine its relation with maximum retention force and with physical parameters including tongue-related variables. 36 non-snoring, asymptomatic young men with normal occlusion were voluntarily participated in this study (mean age: $24.47{\pm}2.58$ years). Experimental procedures consisted of prefabrication of tongue bulb set (20 types with a width of 27-36mm and thickness of 8 and 10 mm), determination of tongue bulb size and the maximum retention force for each subject, and measurement of physical parameters including body mass index (BMI), neck circumference and width, thickness and length of tongue. This study showed that there was significant difference of retention force among the bulb size-related groups both in upright and supine position (p<0.05) and that retention force increased with bulb size. Correlation of tongue bulb size with physical parameters was not clearly verified and there was no significant difference in retention force between upright and supine positions. Based on our results, it can be suggested that retention force relates with tongue bulb size, ultimately with tongue volume. A further study needs to be performed in the patients with snoring and OSA.

A Literature Review of Tongue Movement and Measurement Tools for Dysphagia (연하장애 환자의 혀 운동 및 측정 도구에 대한 고찰)

  • Kim, Jin-Yeong;Son, Yeong-Soo;Hong, Deok-Gi
    • Therapeutic Science for Rehabilitation
    • /
    • v.11 no.4
    • /
    • pp.55-68
    • /
    • 2022
  • Objective : This review aimed to provide information for clinical application by confirming the principles and characteristics of the tool through a review of tongue movement and measurement tools for patients with swallowing disorders. Results : We identified 15 tools used as tongue exercises and measurement tools in the field of dysphagia. According to principle, the tools were classified as either a bulb sensor, resistive sensor sheet, mouthpiece with sensor, or other techniques. The bulb sensor was easy to use but had limitations in fixing the position when measuring tongue pressure. The resistive sensor sheet could be measured at a more stable position than the bulb sensor. A mouthpiece with a sensor could be used in an individual's oral cavity such that the position was fixed when measuring the tongue pressure. Other techniques had the advantage of being wireless and capable of sensing light. Conclusion : Based on this literature review, it is necessary to facilitate the selection of the best tool for quantitative tongue measurement in dysphagia. The review can also be used to develop a Korean tongue movement tool model that can be used in hospitals and community centers.

Effect of CT Contrast Media on Radiation Therapy Planning (Head & Neck Cancer and Prostate Cancer) (CT조영제가 방사선치료계획(두경부, 전립선)에 미치는 영향)

  • Jang, Jaeuk;Han, Manseok;Kim, Minjeong;Kang, Hyeonsoo
    • Journal of the Korean Magnetics Society
    • /
    • v.26 no.5
    • /
    • pp.173-178
    • /
    • 2016
  • This study is to evaluate the effect of a Contrast Media (CM) on dose calculations and clinical significance in Radiation (Electromagnetic wave) Therapy (RT) plans for head & neck (H&N) and prostate cancer. Pinnacle 8.0 system was used to measure the change of Electron Density (ED) of the tissue for CM. To determine the effect of dose calculation due to CM, we did the RT planning for 30 patients. To compare the ED and dose calculations of RT plans, 3D CRT and IMRT plans were do with pinnacle and Tomotherapy planning system. Mean difference of ED between enhanced and unenhanced CT was less than 4%: H&N Target Volume (TV) 2.1%, parotid 1.9%, SMG 3.6%, tongue 0.9%, spinal cord 0.3%, esophagus 2.6%, mandible 0.1% and prostate TV 0.7%, lymph node 1.1%, bladder 1.2%, rectum 1.5%, small bowel 1.2%, colon 0.6%, penile bulb 0.8%, femoral head -0.2%. The dose difference between RT plan using CM and without CM showed an increase of dose in TV. The rate of increase was less than 2.5% (3D CRT: H&N 0.69~2.51%, prostate 0.04~1.14%, IMRT: H&N 0.58~1.31%, prostate 0.36~1.04%). RT plans using a CM has the insignificant effect on the organs and TV, so this error is allowable clinically. However, the much more accurate plan is possible as to image fusion (CM and without CM images) to ROI contour and when dose calculation, use the without CM image. Using the fusion of 'ROI import' perform calculations on without CM, it will be able to reduce the error (1~3%) caused by the CM.