• 제목/요약/키워드: Tonal noise

검색결과 107건 처리시간 0.025초

에어컨 용 횡단류 홴의 특정 주파수 소음 성분의 저감 대책에 관한 연구 -날개의 랜덤 배열과 경사진 스태빌라이저에 대한 연구- (A Study on the Reduction of Discrete Frequency Tones of a Cross-Flow Fan of Air-Conditioners -Studies on the Random Distribution of Fan Blades and the Skewed Stabilizers-)

  • 구형모
    • 소음진동
    • /
    • 제8권5호
    • /
    • pp.870-878
    • /
    • 1998
  • The cross-flow fan which constitutes a fan-duct system with a stabilizer and a scroll casing is widely used in many air-ventilating and air-conditioning devices. Its ooperating points of high efficiency and loading conditions frequently induce a annoying sharp tonal component of discrete frequency on the noise spectrum, which is open called as a BPF(Blade-Passing-Frequency) noise and degrades the sound quality of the devices. this BPF tone has been one of the defects of the cross-flow fan. This study proposes two methods in order to reduce this tonal noise component, which are the random distributions of the fan blades and the skewed shapes of the stabilizer. The proposed methods are verified by a simple analytical model and are applied in manufacturing the cross-flow fan and the stabilizer samples. Some experiments are carried out to verify the reduction capability of BPF tones of above two schemes and the experimental results are analyzed. The comparison between two method is also carried out.

  • PDF

불균일 난류 유입유동이 프로펠러형 송풍기의 톤소음에 미치는 영향에 대한 실험적 연구 (An Experimental Study on the Effects of Non-uniform Inlet Flows upon Tonal Radiation from an Axial-type Propeller Fan)

  • 이승배;김광용;양귀철
    • 한국유체기계학회 논문집
    • /
    • 제1권1호
    • /
    • pp.49-57
    • /
    • 1998
  • The acoustic signatures from a propeller fan under non-uniform inlet flow conditions were measured to reveal the mechanism for tonal radiation. Experimental studies were carried out by generating non-uniform turbulent flows with circumferential and radial components of harmonic incoming gust deliberately. This paper reports the measured acoustic power exponents and cross-spectra for circumferential and radial disturbances at a specified flow-rate coefficient.

  • PDF

뉴럴 네트워크를 이용할 선박의 Tonal성 신호 자동인식에 관한 연구 (A Study for Tonal Signal Automatic Recognition of He Ship Radiated Noise by Neural Network)

  • 이필호;임기현;박규칠;윤종락
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 2004년도 추계학술발표대회논문집 제23권 2호
    • /
    • pp.491-492
    • /
    • 2004
  • 선박의 수중방사소음은 다양한 기계류나 추진기 흑은 선체와 유체간의 상호 작용으로 인하여 여러 형태의 특성신호로 나타나며, 속력 종속적인 추진계통 신호 성분과 비종속적인 보기류 신호 성분이 혼재되어 다수의 신호성분으로 나타난다. 또한 토널 신호의 세기와 바다의 음향 전달 특성 등으로 인하여 신호가 미약하게 되거나 끊어져서 불연속하게 나타나기도 한다. 본 연구에서는 이러한 점을 해결하기 위해 선박의 Tonal성 신호를 자동으로 탐지하고 분류하기 위해 스펙트로그램 상에서 연속되는 신호에 가중치를 주어 지속성 신호여부를 판별한 후에 정해진 임계치를 초과하는 성분을 Tonal로 선정하였으며, 선정된 Tonal 신호의 발생 기원이 속력 종속/비종속적인지를 자동으로 판별하는 알고리즘을 실제 선박 방사소음에 대해 적용한 결과에 대해 보고한다.

  • PDF

도로 소음 저감을 위한 능동소음제어 시스템의 개발 및 기초실험 (Development and Basic Experiment of Active Noise Control System for Reduction of Road Noise)

  • 문학룡;강원평;임유진
    • 한국도로학회논문집
    • /
    • 제15권6호
    • /
    • pp.41-47
    • /
    • 2013
  • PURPOSES : The purpose of this study is about noise which is generated from roads and is consist of irregular frequency variation from low frequency to various band. The existing methods of noise reduction are sound barrier that uses insulation material and absorbing material or have applied passive technology of noise reduction by devices. The total frequency band is needed to apply active noise control. METHODS : In this study applies to the field of road traffic environment, signal processing controller and various analog signal input/output, the amplifier module is based on parallel-core embedded processor designed. DSP performs the control algorithm of the road traffic noise. Noise sources in the open space performance of evaluation were applied. In this study, controller of active signal processor was designed based on the module of audio input/output and main controller of embedded process. The controller of active signal processor operates noise reduction algorithm and performance tests of noise reduction in inside and outside environment were executed. RESULTS : The signal processing controller with OMAP-L137 parallel-core processors as the center, DSP processors in the active control operations dealt with quickly. To maximize the operation speed of an object and ARM processor is external function keys and display for functions and evaluating the performance management system was designed for the purpose of the interface. Therefore the reduction of road traffic noise has established an electronic controller-based noise reduction. CONCLUSIONS : It is shown that noise reduction is effective in the case of pour tonal sound and complex tonal sound below 500Hz by appling to Fx-LMS.

ON IMPROVING THE QUALITY OF RELP VOCODER

  • Oh, S.K.
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 1985년도 학술발표회 논문집
    • /
    • pp.79-86
    • /
    • 1985
  • Residual-ecited linear prediction vocoding is known to be one of the best approaches to speech coding in the range of 4.8 to 9.6 kbits/s. One problem associated with the RELP vocoder is that it often produces some roughness and tonal noise as the transmission rate becomes lower. In this paper, we investigate three methods to improve its quality. These include the multiband spectral folding method, the method of using both the spectrally folded signal and the pulsed ecitation signal, and the method of using both the multiband spectrally folded signal and the pulsed ecitation signal. It has been found that, among the three methods, the last one yields the best performance. It produces no roughness and little tonal noise.

  • PDF

축소형 UH-1H 로터에서의 광역소음과 이산소음의 비교 (Comparison of Discrete Noise with Broadband Noise from Small-scaled UH-1H Rotor)

  • 유기완
    • 한국항공우주학회지
    • /
    • 제33권1호
    • /
    • pp.20-25
    • /
    • 2005
  • 본 연구에서는 UH-1H 헬리콥터의 축소 로터에 대한 두께소음과 하중소음, 그리고 와류흘림에 의한 광역소음을 각각 수치계산을 통해 얻어내고, 그 크기를 비교하였다. 로터의 후류형상은 Kocurek과 Tangler의 지정후류 방법을 사용하였으며, 팁 마하수 $M_{T}$의 범위는 0.2, 0.4, 0.8로 나누어서 유동장 계산과 그에 따른 소음해석을 시도하였다. 팁 마흐 수 $M_{T}$ = 0.8에서 와류 흘림에 의한 광역 소음은 가청주파수 대역 및 A-가중함수를 고려하였을 때에 상대적으로 저주파수 특성을 갖는 두께소음이나 하중소음에 비해 작은 값을 보이는 것으로 나타났다. 특히 광역소음은 가청주파수를 벗어난 초음파 영역에서 대부분의 음압을 방사하는 것으로 나타났다. 반면 $M_{T}$를 0.4 이하로 하였을 때에는 광역소음이 저주파수 영역으로 이동하면서 이산소음에 비해 더 소음레벨을 보이는 것으로 나타났다. 즉, 저속 회전하는 헬리콥터 로터의 경우에는 광역소음의 고려가 필수적임을 알 수 있다.

KTX 차량 곡선부 스퀼 소음 특성 (Analysis of curve squeal noise for KTX train)

  • 이찬우;김재철
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집
    • /
    • pp.1187-1190
    • /
    • 2009
  • CURVE SQUEAL NOISE IS THE INTENSE HIGH FREQUENCY TONAL THAT CAN OCCUR WHEN A RAILWAY VEHICLE TRAVERSES A CURVE OR A SWITCH. THE HIGH NOISE LEVEL CAUSES ANNOYANCE FOR PEOPLE WHO LIVE IN THE NEIGHBOURHOOD OF THE SQUEALING RAILWAY TRACK AS WELL AS FOR THE PASSENGERS IN CARS WITH CURVES. THIS PAPER EXAMINES THE SPECTRAL SOUND DISTRIBUTION IN CURVES FOR KTX TRAIN. THE FREQUENCY RANGE IS FROM AROUND 4,000 TO ALMOST 16,000Hz, WITH NOISE LEVELS UP TO 92dB IN CURVE R400.

  • PDF

Aeroacoustic Characteristics and Noise Reduction of a Centrifugal Fan for a Vacuum Cleaner

  • Jeon, Wan-Ho;Rew, Ho-Seon;Kim, Chang-Joon
    • Journal of Mechanical Science and Technology
    • /
    • 제18권2호
    • /
    • pp.185-192
    • /
    • 2004
  • The aeroacoustic characteristics of a centrifugal fan for a vacuum cleaner and its noise reduction method are studied in this paper. The major noise source of a vacuum cleaner is the centrifugal fan. The impeller of the fan rotates at over 30000 rpm, and generates very high-level noise. It was revealed that the dominant noise source is the aerodynamic interaction between the rotating impeller and stationary diffuser. The directivity of acoustic pressure showed that most of the noise propagates backward direction of the fan-motor assembly. In order to reduce the high tonal sound generated from the aerodynamic interaction, unevenly pitched impeller and diffuser, and tapered impeller designs were proposed and experiments were performed. Uneven pitch design of the impeller changes the sound quality while the overall sound power level (SPL) and the performance remains similar. The effect of the tapered design of impeller was evaluated. The trailing edge of the tapered fan is inclined. This reduces the flow interaction between the rotating impeller and the stationary diffuser because of some phase shifts. The static efficiency of the new impeller design is slightly lower than the previous design. However, the overall SPL is reduced by about 4 dB(A). The SPL of the fundamental blade passing frequency (BPF) is reduced by about 6 dB (A) and the 2$\^$nd/ BPF is reduced about 20 dB (A). The vacuum cleaner with the tapered impeller design produces lower noise level than the previous one, and the strong tonal sound was dramatically reduced.

차세대 고속전철 차량연결부의 저소음 형상설계를 위한 차량연결부의 2차원적 수치해석 연구 (Two Dimensional Numerical Study in Gangway of Next Generation High Speed Train For Reduction of Aero-acoustic Noise)

  • 강형민;김철완;조태환;전완호;윤수환;권혁빈;박춘수
    • 한국철도학회논문집
    • /
    • 제14권4호
    • /
    • pp.327-332
    • /
    • 2011
  • 본 연구에서는 차세대 고속전철의 차량 연결부 저소음 형상 설계를 위한 선행연구로서 차량연결부의 공기역학적 소음 해석을 수행하였다. 이를 위해 차량 연결부는 Mud Flap 형상을 고려한 2차원 Cavity로 가정하였으며, Mud Flap 사이의 간극을 주요 변수로 하여 5개의 간극에 대하여 Parametric Study를 수행하였다. 이를 토대로 차량 Mud Flap 사이의 간극에 따른 Vortex Shedding 등의 유동 특성에 대한 해석을 수행하였다. 또한 높이 별로 3개의 Microphone 위치를 선정하고 간극에 따른 Tonal Noise 및 Overall Noise 등의 공기역학적 소음 특성을 분석하였으며, 차량 연결부 Mud Flap 간 간극 및 소음 특성 간의 상관 관계를 평가하였다. 그 결과 기본 및 특정한 Mud flap 간 간극에서의 소음 특성이 다른 형상에 비해 우수함을 확인하였다.

Atomic norm minimization을 통한 수중 방사 소음 신호의 토널 주파수 탐지 (Detection of tonal frequency of underwater radiated noise via atomic norm minimization)

  • 김준한;김진홍;심병효;홍정표;김성일;홍우영
    • 한국음향학회지
    • /
    • 제38권5호
    • /
    • pp.543-548
    • /
    • 2019
  • 수중 표적의 기어박스 및 보조 장치 등으로부터 방사되는 토널 신호의 주파수 성분은 처리하고자 하는 주파수 대역에 비해 상대적으로 적어 희소신호로 모델링될 수 있다. 근래에 토널 신호의 주파수 희소성을 이용하여 빠른 시간 내에 적은 수의 관측치로 토널 주파수를 복원하는 압축센싱 기반의 연구가 활발히 진행되고 있다. 기존의 방법들은 이산(discrete) 주파수 영역에서 주파수를 검출하기 때문에 이산화로 인한 basis mismatch error가 불가피하다. 본 논문에서는 atomic norm minimization을 이용하여 적은 수의 관측치로 연속(continuous) 주파수 영역에서 토널 주파수를 검출하는 기법을 제안한다. 모의실험을 통해 기존의 기법들에 비해 제안하는 기법의 성능이 정확성과 평균제곱오차 측면에서 우수함을 확인하였다.