• Title/Summary/Keyword: Ton of $CO_2$

Search Result 333, Processing Time 0.03 seconds

Performance Analysis of Upgrading Process with Amine-Based CO2 Capture Pilot Plant

  • Kwak, No-Sang;Lee, Junghyun;Lee, Dong Woog;Lee, Ji Hyun;Shim, Jae-Goo
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.4 no.1
    • /
    • pp.33-38
    • /
    • 2018
  • This study applied upgrades to the processes of a 10 MW wet amine $CO_2$ capture pilot plant and conducted performance evaluation. The 10 MW $CO_2$ Capture Pilot Plant is a facility that applies 1/50 of the combustion flue gas produced from a 500 MW coal-fired power plant, and is capable of capturing up to 200 tons of $CO_2$. This study aimed to quantitatively measure efficiency improvements of post-combustion $CO_2$ capture facilities resulting from process upgrades to propose reliable data for the first time in Korea. The key components of the process upgrades involve absorber intercooling, lean/rich amine exchanger efficiency improvements, reboiler steam TVR (Thermal Vapor Recompression), and lean amine MVR (Mechanical Vapor Recompression). The components were sequentially applied to test the energy reduction effect of each component. In addition, the performance evaluation was conducted with the absorber $CO_2$ removal efficiency maintained at the performance evaluation standard value proposed by the IEA-GHG ($CO_2$ removal rate: 90%). The absorbent used in the study was the highly efficient KoSol-5 that was developed by KEPCO (Korea Electric Power Corporation). From the performance evaluation results, it was found that the steam consumption (regeneration energy) for the regeneration of the absorbent decreased by $0.38GJ/tonCO_2$ after applying the process upgrades: from $2.93GJ/ton\;CO_2$ to $2.55GJ/tonCO_2$. This study confirmed the excellent performance of the post-combustion wet $CO_2$ capture process developed by KEPCO Research Institute (KEPRI) within KEPCO, and the process upgrades validated in this study are expected to substantially reduce $CO_2$ capture costs when applied in demonstration $CO_2$ capture plants.

Budget and distribution of organic carbon in Taxus cuspidata forest in subalpine zone of Mt. Halla

  • Jang, Rae-Ha;Jeong, Heon-Mo;Lee, Eung-Pill;Cho, Kyu-Tae;You, Young-Han
    • Journal of Ecology and Environment
    • /
    • v.41 no.1
    • /
    • pp.19-28
    • /
    • 2017
  • Background: In order to investigate organic carbon distribution, carbon budget, and cycling of the subalpine forest, we studied biomass, organic carbon distribution, litter production, forest floor litter, accumulated soil organic carbon, and soil respiration in Taxus cuspidata forest in Halla National Park from February 2012 to November 2013. Biomass was calculated by using allometric equation and the value was converted to $CO_2$ stocks. Results: The amount of plant organic carbon was $13.60ton\;C\;ha^{-1}year^{-1}$ in 2012 and $14.29ton\;C\;ha^{-1}year^{-1}$ in 2013. And average organic carbon introduced to forest floor through litter production was $0.71ton\;C\;ha^{-1}year^{-1}$. Organic carbon distributed in forest floor litter layer was $0.73ton\;C\;ha^{-1}year^{-1}$ on average and accumulated organic carbon in soil was $51.13ton\;C\;ha^{-1}year^{-1}$ on average. In 2012, Amount of released $CO_2$ from soil to atmosphere was 10.93 ton $CO_2ha^{-1}year^{-1}$. Conclusions: The net ecosystem production based on the difference between net primary production of organic carbon and soil respiration was $-1.74ton\;C\;ha^{-1}year^{-1}$ releasing more carbon than it absorbed.

A Study on Energy Consumption and Estimation of CO2 from Re-bar Production (철근 생산과정의 에너지 사용량 및 CO2배출량 산출에 관한 연구)

  • Choi, Jae-Hwi;Lee, Dong-Hoon;Kwon, Gi-Deoc;Kim, Sun-Kuk
    • KIEAE Journal
    • /
    • v.10 no.4
    • /
    • pp.101-109
    • /
    • 2010
  • As global warming progresses, nations around the world are trying to reduce emission of $CO_2$ that accounts for the greatest portion of greenhouse gases. To reduce $CO_2$ emission, it is first necessary to estimate $CO_2$ emission of each industry. Government authorities estimate basic unit of $CO_2$ emission from re-bar that is one of the key materials of construction industry with LCA technique (Life Cycle Assessment). However, basic unit of $CO_2$ emission varies from organization to organization. The Ministry of Land, Transport and Maritime Affairs (2004) publishes it 3.48($TCO_2/ton$) and 0.30($TCO_2/ton$) with input-output analysis while the Korea Environmental Industry & Technology Institute (2008) defines it as 0.34($TCO_2/ton$) with process analysis, which indicates ambiguity in application of basic unit of $CO_2$emission. Based on the analysis of conventional methods used for estimating the $CO_2$ emission, therefore, this research suggests existing problems on the methods and focuses on proposing an strategy to effectively estimate the basic unit of $CO_2$ emission according to the energy consumption limited to the re-bar production in steel mill in order to overcome the problems. The result of this research is expected to be helpful in calculating and reducing $CO_2$ emission.

Calculation and Projection of Greenhouse Gas Emissions from La Chureca Landfill in Managua, Nicaragua (니카라과 마나과시 La Chureca 매립장 온실가스 발생량 산정 및 예측)

  • Kim, Choong Gon;Lee, Hyun Jun;Kang, Ho Jeung;Kim, Jae Young
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.30 no.4
    • /
    • pp.131-139
    • /
    • 2022
  • The aim of this study was to assess the feasibility of a landfill project to reduce greenhouse gas (GHG) from La Chureca Landfill in Managua, Nicaragua ("Project"). The feasibility study involved surveying the status and composition of waste on its way in to the landfill and projecting GHG emissions from the landfill. A projection of the GHG emissions with the IPCC model based on the survey results indicated the period 2006 to 2043 would see mean yearly GHG emissions of 290,147 ton-CO2/year with model certainty not considered, and 217,610 ton-CO2/year with model certainty considered. Thus, the result exceeded the corresponding median and mean values of other CDM projects implemented in Central America, even after model uncertainty was considered together with the conservative estimation of carbon capture efficiency. The similar result was produced even with an analysis of sensitivity to error factors. All the findings of the study are expected to be applicable as basic data for deciding about whether & how to proceed with the Project.

Analysis of Performance and Energy Saving of a SOFC-Based Hybrid Desiccant Cooling System (건물용 연료전지 기반 하이브리드 제습냉방시스템 성능 및 에너지 절감 분석)

  • IN, JUNGHYUN;LEE, YULHO;KANG, SANGGYU;PARK, SUNGJIN
    • Journal of Hydrogen and New Energy
    • /
    • v.30 no.2
    • /
    • pp.136-146
    • /
    • 2019
  • A solid oxide fuel cell (SOFC) based hybrid desiccant cooling system model is developed to study the effect of fuel utilization rate of the SOFC on the reduction of energy consumption and $CO_2$ emission. The SOFC-based hybrid desiccant cooling system consists of an SOFC system and a Hybrid desiccant cooling system (HDCS). The SOFC system includes a stack and balance of plant (BOP), and HDCS. The HDCS consists of desiccant rotor, indirect evaporative cooler, electric heat pump (EHP), and heat exchangers. In this study, using energy load data of a commercial office building and SOFC-based HDCS model, the amount of ton of oil equivalent (TOE) and ton of $CO_2$ ($tCO_2$) are calculated and compared with the TOE and $tCO_2$ generation of the EHP using grid electricity.

A Study on the Availability of Spatial and Statistical Data for Assessing CO2 Absorption Rate in Forests - A Case Study on Ansan-si - (산림의 CO2 흡수량 평가를 위한 통계 및 공간자료의 활용성 검토 - 안산시를 대상으로 -)

  • Kim, Sunghoon;Kim, Ilkwon;Jun, Baysok;Kwon, Hyuksoo
    • Journal of Environmental Impact Assessment
    • /
    • v.27 no.2
    • /
    • pp.124-138
    • /
    • 2018
  • This research was conducted to examine the availability of spatial data for assessing absorption rates of $CO_2$ in the forest of Ansan-si and evaluate the validity of methods that analyze $CO_2$ absorption. To statistically assess the $CO_2$ absorption rates per year, the 1:5,000 Digital Forest-Map (Lim5000) and Standard Carbon Removal of Major Forest Species (SCRMF) methods were employed. Furthermore, Land Cover Map (LCM) was also used to verify $CO_2$ absorption rate availability per year. Great variations in $CO_2$ absorption rates occurred before and after the year 2010. This was due to improvement in precision and accuracy of the Forest Basic Statistics (FBS) in 2010, which resulted in rapid increase in growing stock. Thus, calibration of data prior to 2010 is necessary, based on recent FBS standards. Previous studies that employed Lim5000 and FBS (2015, 2010) did not take into account the $CO_2$ absorption rates of different tree species, and the combination of SCRMF and Lim5000 resulted in $CO_2$ absorption of 42,369 ton. In contrast to the combination of SCRMF and Lim5000, LCM and SCRMF resulted in $CO_2$ absorption of 40,696 ton. Homoscedasticity tests for Lim5000 and LCM resulted in p-value <0.01, with a difference in $CO_2$ absorption of 1,673 ton. Given that $CO_2$ absorption in forests is an important factor that reduces greenhouse gas emissions, the findings of this study should provide fundamental information for supporting a wide range of decision-making processes for land use and management.

Studies on the Productivity and the Productive Structure of the Forests III. Comparison between the Productivity of Pinus rigida and of Pinus rigitaeda Plantation (삼림의 생산구조와 생산력에 대한 연구 III. 리기다소나무와 리기테다소나무의 비교)

  • 김준호
    • Journal of Plant Biology
    • /
    • v.19 no.3
    • /
    • pp.85-91
    • /
    • 1976
  • A comparison betwen the productivity of Pinus rigida which is native in the Eastern United States, and P. rigitaeda which is F1 hybrid between P. rigida and P. taeda, has been established. For each tree the diameter at breast height (D) and the height of tree (H) were measured in three years. The standard sample trees were down and then weighed each organ. From obtained data the allometric relation between $D_2H$ and dry weight of the trunk (Ws), the branches (Wb) and the leaves (Wl) of P. rigida were approxmated by $$Ws=0.0592 (D^2H)^{0.837}$$ $$Wb=0.0065 (D^2H)^{0.989}$$ $$Wl=0.0447(D^2H)^{0.690}$$ and those of P. rigitaeda were approximated by $$Ws=0.0522 (D^2H)^{0.843}$$ $$Wb=0.0037 (D^2H)^{1.117}$$ $$Wl=0.0207 (D^2H)^{0.856}$$ From the above, the standing crops of above ground of P. rigida were estimated to be as much as 16.93-34.35 ton dry matter per ha, and those of P. rigitaeda were 20.45-45.55 ton per ha. Annual net production was appraised at 8.07-9.35 ton/ha.yr in P. rigida and at 11.59-13.41 ton/ha.yr in P. rigitaeda (1.0:1.4). It is assumed that high productivity of P. rigitaeda stand compared with P. rigida resulted from an increase of the leaf amount with age. Photosynthetic ability under the saturated light of the current and theold leaves of P. rigida were respectively 2.62 and 0.66mg CO2/g. d. wt..hr and those of P. rigitaeda were 1.17 and 0.96mg CO2/g.d. wt.hr. Respiration of the current and the old leaves at $25^{\circ}C$ were 1.00 and 0.90 mg CO2/g. d. wt..hr. in P. rigida and 0.90 and 0.45mg CO2/g.d.wt.hr in P. rigitaeda. It is assumed that photosynthetic longevity of P. rigitaeda leaves was vigorously maintained longer than that of P. rigida.

  • PDF

Characteristics of $H_2$/CO ratio control of syngas by waste gasification (폐기물 가스화 합성가스의 $H_2$/CO 생산비 제어 특성)

  • Gu, Jae-Hoi;Kim, Su-Hyun;Kim, Mun-Hyun;Choi, Jong-Hyea;Heo, Su-Jung;Yoon, Ki-Soo;Kim, Soung-Hyoun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.475-478
    • /
    • 2008
  • The 3 ton/day-scale pilot plant consists of waste press, feed channel, fixed bed type gasification & melting furnace, quench scrubber, syngas refinery facility and flare stack. $H_2$/CO ratio of gasification syngas using the solid waste and sludge in the 3 ton/day gasifier showed about 1. Gasification melting furnace was operated $1,300{\sim}1,600^{\circ}C$. $H_2$/CO ration control system was obtained $H_2$/CO ratio 2 and 3.

  • PDF

The Greenhouse-Gas Mitigation Potential analysis by Distribution of Solar Thermal System in Housing Sector (태양열난방시스템 도입에 따른 주거부문에서의 온실가스 감축 잠재량 분석)

  • Jeong, Young-Sun;Mun, Sun-Hye;Yu, Ki-Hyung
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.1
    • /
    • pp.32-39
    • /
    • 2012
  • New and renewable energy systems(solar thermal system, photovoltaic system, geothermal system, wind power system) are environmentally friendly technologies and these in South Korea are very important measures to reduce greenhouse-gas(GHG) and to push ahead with Green Growth. The purpose of this paper is to analyze GHG mitigation potential by distribution of solar thermal system in housing sector with bottom-up model called 'Long-range Energy Alternative Planning system'. Business as usual(BAU) was based on energy consumption characteristic with the trend of social-economic prospects and the volume of housing. The total amount of GHG emission of BAU was expected to continuous increase from 66.0 million-ton $CO_{2e}$ in 2007 to 73.1 million-ton $CO_{2e}$ in 2030 because of the increase of energy consumption in housing. The alternative scenario, distribution of solar thermal system in housing sector had GHG mitigation potential 1.54 million-ton $CO_{2e}$ in 2030. The results of this study showed that new and renewable energy systems made a contribution of reducing the use of fossil fuel and the emission of greenhouse-gas in building.

A Study on Effects of Vegetative Cover on Atmospheric Purification in Seoul, Korea (서울시 도시녹지의 대기정화효과)

  • Cho, Yong-Hyeon;Jo, Hyun-Kil
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.5 no.4
    • /
    • pp.51-60
    • /
    • 2002
  • This study quantified $CO_2$, $SO_2$ and $NO_2$ uptake by vegetation in Seoul. The natural area was only 20% of the area of Seoul and its tree-age structure was dominated by a young and growing tree population. However the natural area accounted for about 65%, 60%, and 59% of total $CO_2$, $SO_2$ and $NO_2$ uptake relatively. In natural area broad-leaved forest was dominative and accounted for about 37.8%, 36.7%, 36.6% of total $CO_2$, $SO_2$ and $NO_2$ uptake in Seoul relatively. In urbanized area the park type land use played an important role. It's area was only 17% of the urbanized area in Seoul, but it accounted for about 67%, 57%, and 56% of $CO_2$, $SO_2$ and $NO_2$ uptake in urbanized area relatively. Total annual uptake by vegetative cover was estimated as 446,741 ton/yr for $CO_2$, 314 ton/yr for $SO_2$ and 815 ton/yr for $NO_2$, and economic value of atmospheric purification for the entire area of Seoul amounted to approximately \228,073 millions/yr for the annual $CO_2$, $SO_2$ and $NO_2$ uptake. The results from this study are expected to be useful not merely in informing the public of atmospheric purification values of vegetative cover, but in urging the necessity for replanting and management budgets.