• Title/Summary/Keyword: Tomography, emission-computed, single-photon

Search Result 155, Processing Time 0.022 seconds

Influence of Ischemic Lesions on $^{99m}Tc$-HMPAO SPECT Findings in the Diagnosis of Alzheimer's Disease ($^{99m}Tc$-HMPAO SPECT를 이용한 알쯔하이머병의 진단에서 허혈성 뇌병변이 미치는 영향)

  • Lee, Kyung-Han;Lee, Myung-Chul;Lee, Dong-Soo;Kwon, June-Soo;Kim, Jong-Ho;Chung, June-Key;Woo, Jong-In;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.3
    • /
    • pp.282-292
    • /
    • 1994
  • Brain perfusion SPECT shows typical regional perfusion abnormalities in Alzheimer's disease(AD) and is useful for its diagnosis. However, there is also arguement that these patterns show significant overlap with other causes, and the accuracy for SPECT in differentiating AD has shown conflicting results. We postulate that the variation in re-ported results are partly due to a difference in patient or control selection with special reference to the mixture of ischemic cerebral disease in the studied population. To deter-mine the effect of ischemic lesions and the nature of control subjects on SPECT studies for AD, we performed $^{99m}Tc$-HMPAO single photon emission computed tomography (SPECT) in 11 probable AD patients with a low (<4) Hachinski ischemic score and 12 non-demented age matched controls. Magnetic resonance imaging(MRI) disclosed ischemic cerebral lesions in 27% (3/11) of the PAD group and 25% (3/12) of the control group. Regional perfusion indices were quantitated from the SPECT images as follows and the distribution of perfusion indices from both groups were compared. This was repeated with controls after excluding those with significant ischemic lesions by MRI : regional perfusion index = average regional count/average cerebellar count All PAD patients showed perfusion abnormality in SPECT. However, 53% (10/12) of controls also showed perfusion at-normalities, and no pattern could reliably differentiate the two groups. After excluding controls with significant cerebral ischemia, the difference in temporal and parietal perfusion index was increased. A decreased tempore-parietal and any parietal or temporal per-fusion index had a sensitivity of 18% and 36% in detecting AD, respectively. When using a separate group of normal age mathced controls, the indices showed an even more difference in the temporal and parietal lobes and the sensitivity of a decreased tempore-parietal and any parietal or temporal perfusion index had a sensitivity of 36% and 55% in detecting AD, respectively. Thus, the type of control with special reference to the pres-once of ischemic cerebral lesions contribute significantly to the accuracy of perfusion SPECT in diagnosing AD. This nay have particular importance in the diagnosis of AD in populations where the prevalance of cerebrovascular disease is high.

  • PDF

Lesion Localization in Patients with Hyperparathyroidism Using Double-phase Tc-99m MIBI Parathyroid Scintigraphy (부갑상선기능항진증 환자에서 Tc-99m MIBI 부갑상선 신티그라피를 이용한 병소 국소화)

  • Shin, Jung-Woo;Ryu, Jin-Sook;Kim, Jae-Seung;Moon, Dae-Hyuk;Hong, Seung-Mo;Gong, Gyung-Yub;Hong, Suk-Joon;Lee, Hee-Kyung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.2
    • /
    • pp.120-130
    • /
    • 1999
  • Purpose: This study was performed to evaluate the diagnostic usefulness of double-phase Tc-99m MIBI parathyroid scintigraphy with single photon emission computed tomography (SPECT) in patients with hyper-parathyroidism. We also evaluated the relationship between Tc-99m MIBI uptake and oxyphil cell contents in parathyroid glands. Materials and Methods: The subjects were 28 parathyroid glands of 10 patients who underwent Tc-99m MIBI parathyroid scintigraphy and parathyroidectomy for clinically suspected hyper-parathyroidism. Early and delayed pinhole images were obtained at 15 minutes and 2 hours after injection of Tc-99m MIBI, and SPECT images were followed. The weight and oxyphil cell contents of parathyroid tissue were obtained from pathologic specimen, and the scintigraphic findings were compared with histopathology. Results: In surgical histopathology, 6 parathyroid adenomas and 9 parathyroid hyperplasias were confirmed. The sensitivity, specificity, and positive predictive value of early and delayed images were 46.7% (7/15), 76.9% (10/13), 70% (7/10) and 66.7% (10/15), 92.3% (12/13), 90.9% (10/11), respectively. SPECT image detected an additional small hyperplasia.. The sensitivity, specificity, and positive predictive value of combined interpretation of early and delayed images with SPECT were 73.3% (11/15), 100% (13/13), 100% (11/11). The sensitivity was 100% (6/6) for adenoma, whereas that was 55.5% (5/9) for hyperplasia. Both adenomas and hyperplasias showed significantly increased oxyphil cell contents compared with normal parathyroid glands (p<0.0001), but the oxyphil cell content and weight were not significantly different between adenomas and hyperplasias. Conclusion: Double-phase Tc-99m MIBI parathyroid scintigraphy with SPECT is useful for lesion localization in patients with hyperparathyroidism. Although both adenoma and hyperplasia have increased oxyphil cell content, the sensitivity is high in adenoma, but low in hyperplasia.

  • PDF

Diagnostic Performance of Combined Single Photon Emission Computed Tomographic Scintimammography and Ultrasonography Based on Computer-Aided Diagnosis for Breast Cancer (유방 SPECT 및 초음파 컴퓨터진단시스템 결합의 유방암 진단성능)

  • Hwang, Kyung-Hoon;Lee, Jun-Gu;Kim, Jong-Hyo;Lee, Hyung-Ji;Om, Kyong-Sik;Lee, Byeong-Il;Choi, Duck-Joo;Choe, Won-Sick
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.3
    • /
    • pp.201-208
    • /
    • 2007
  • Purpose: We investigated whether the diagnostic performance of SPECT scintimammography (SMM) can be improved by adding computer-aided diagnosis (CAD) of ultrasonography (US). Materials and methods: We reviewed breast SPECT SMM images and corresponding US images from 40 patients with breast masses (21 malignant and 19 benign tumors). The quantitative data of SPECT SMM were obtained as the uptake ratio of lesion to contralateral normal breast. The morphologic features of the breast lesions on US were extracted and quantitated using the automated CAD software program. The diagnostic performance of SPECT SMM and CAD of US alone was determined using receiver operating characteristic (ROC) curve analysis. The best discriminating parameter (D-value) combining SPECT SMM and the CAD of US was created. The sensitivity, specificity and accuracy of combined two diagnostic modalities were compared to those of a single one. Results: Both SPECT SMM and CAD of US showed a relatively good diagnostic performance (area under curve = 0.846 and 0.831, respectively). Combining the results of SPECT SMM and CAD of US resulted in improved diagnostic performance (area under curve =0.860), but there was no statistical differerence in sensitivity, specificity and accuracy between the combined method and a single modality. Conclusion: It seems that combining the results of SPECT SMM and CAD of breast US do not significantly improve the diagnostic performance for diagnosis of breast cancer, compared with that of SPECT SMM alone. However, SPECT SMM and CAD of US may complement each other in differential diagnosis of breast cancer.

Development of Unmatched System Model for Iterative Image Reconstruction for Pinhole Collimator of Imaging Systems in Nuclear Medicine (핀홀콜리메이터를 사용한 핵의학영상기기의 순환적 영상 재구성을 위한 비동일 시스템 모델 개발)

  • Bae, Jae-Keon;Bae, Seung-Bin;Lee, Ki-Sung;Kim, Yong-Kwon;Joung, Jin-Hun
    • Journal of radiological science and technology
    • /
    • v.35 no.4
    • /
    • pp.353-360
    • /
    • 2012
  • Diverse designs of collimator have been applied to Single Photon Emission Computed Tomography (SPECT) according to the purpose of acquisition; thus, it is necessary to reflect geometric characteristic of each collimator for successive image reconstruction. This study carry out reconstruction algorithm for imaging system in nuclear medicine with pinhole collimator. Especially, we study to solve sampling problem which caused in the system model of pinhole collimator. System model for a maximum likelihood expectation maximization (MLEM) was developed based on the geometry of the collimator. The projector and back-projector were separately implemented based on the ray-driven and voxel-driven methods, respectively, to overcome sparse sampling problem. We perform phantom study for pinhole collimator by using geant4 application for tomographic emission(GATE) simulation tool. The reconstructed images show promising results. Designed iterative reconstruction algorithm with unmatched system model effective to remove sampling problem artefact. Proposed algorithm can be used not only for pinhole collimator but also for various collimator system of imaging system in nuclear medicine.

Clinical Significance of Reverse Redistribution Phenomenon on Delayed Tc-99m Tetrofosmin Myocardial Perfusion Imaging in Patients with Acute Myocardial Infarction (급성 심근경색 환자의 Tc-99m Tetrofosmin 심근 관류 지연영상에서 관찰되는 역재분포 현상의 임상적 의의)

  • Park, Soon-Ah;Kim, Dae-Weung;Kim, Chang-Guhn;Jeong, Jin-Won;Kim, Nam-Ho;Yun, Kyeong-Ho
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.2
    • /
    • pp.112-119
    • /
    • 2009
  • Purpose: This study was performed to investigate the clinical significance of reverse redistribution(RR) phenomenon detected on delayed Tc-99m tetrofosmin myocardial single photon emission computed tomography(SPEG) in patients with acute myocardial infarction after revascularization. Materials and Methods: A Tc-99m tetrofrosmin myocardial SPECT was performed in 67 consecutive patients after revascularization for acute myocardial infarction. Myocardial SPECT imaging was performed for early imaging at 40 min and for delayed imaging at 180 min after reinjection at myocardial stress. Regional myocardial uptakes were scored by 4-point scoring in the left ventricular wall divided into 17 segments. Reverse redistribution was defined as an increase of more than 2 point in the activity score on the delayed image. Follow-up myocardial SPECT and coronary angiography(CAG) were performed 9 months later. Results: On myocardial SPECT performed following revascularization, RR was observed in 100 of all 319 segments(31%) and in 43 patients(64%). The abnormalities of perfusion and regional wall motion were more severe in the patients with RR compared to those without RR(p<0.05). On follow-up myocardial SPECT, the myocardial perfusion, regional wall motion, and myocardial thickness were significantly improved in the patients with RR(p<0.05) however, these changes were not significant in those without RR. There was no significant difference between the patients with RR and those without RR in the occurrence of restenosis on CAG. Conclusions: In patients with acute myocardial infarction, the regions showing the RR phenomenon on delayed Tc-99m tetrofosmin SPECT may reflect viable myocardium and indicate recovery of salvaged myocardium.

Clinical Usefulness of 99mTc-DMSA Renal SPECT Using High Sensitivity-All Purpose Collimator for Pediatric Patients (고감도 범용성 콜리메이터를 이용한 소아 환자 99mTc-DMSA 신장 SPECT의 유용성)

  • Kim, Jin-Eui;Kim, Jung-Soo;Han, Jae-Bok;Choi, Nam-Gil
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.3
    • /
    • pp.219-231
    • /
    • 2016
  • $^{99m}Tc$-DMSA planar scan that can analyze the functions of kidney quantitatively provides less information on a lesion than tomography scanning. Therefore, this study applied a high sensitivity all-purpose collimator that is sensitive to photonic signals to $^{99m}Tc$-DMSA and carried out a clinical scan with single photon emission computed tomography (SPECT). And diagnostic accuracy and time requirement of were analyzed to know the clinical usefulness of the applied scanning method. 10 subjects were intravenously injected with radiopharmaceutical product (1.0-1.2 MBq/kg) and scanned by a gamma camera with planar scanner (high resolution (HR)-mode, $256{\times}256$, 50 kcts/view, 4 image) and SPECT (HR / high sensitive (HS)-mode, $128{\times}128$, step and shoot, $180^{\circ}$, variable sec/angle, total 64 frame, OSEM reconstruction), respectively. The collected data was compared with an analysis program. The results showed that HS-mode SPECT detected total counts 1.8-5.6 times more than planar scan. Relative renal function evaluated based on the counts was not significantly different by two scanning methods (p=0.96) and it turned out that test time was shortened by 39% when HS-mode SPECT was used. Therefore, SPECT using HR, HS-mode collimator could analyze renal function more quantitatively than using planar scan and the former could diagnose the location information of a lesion more accurately than the latter as well as shortened test time requirement, which demonstrated the clinical usefulness of $^{99m}Tc$-DMSA renal SPECT using high sensitivity all purpose collimator.

Assessment of Cerebral Collateral Circulation Using $^{99m}Tc$-Hexamethyleneamine Oxime (HMPAO) SPECT During Internal Carotid Artery Balloon Test Occlusion (내경동맥 풍선 시험 결찰술(BTO)시 $^{99m}Tc$-HMPAO 뇌 SPECT를 이용한 대뇌 측부 순환의 평가)

  • Ryu, Young-Hoon;Yun, Mi-Jin;Chung, Tae-Sub;Lee, Jong-Doo;Park, Chang-Yun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.1
    • /
    • pp.22-30
    • /
    • 1995
  • To predict preoperatively the safety of permanent occlusion of an internal carotid artery with $^{99m}Tc$-HMPAO brain single photon emission computed tomography(SPECT) from an objective point of view, Twenty-four patients underwent balloon test occlusion (BTO) of the internal carotid arteries because of neck and skull base tumors. The authors assessed the uptake of both middle cerebral artery territories before and during BTO with $^{99m}Tc$-HMPAO brain SPECT using semiquantitative analysis method and compared the results with other factors(neurologic examination, arterial stump pressure and electroenceph-alogram). Nineteen patients had not experienced neurological deteriorating or any problem during BTO. Their comparative uptakes of the middle cerebral artery territories were 95 to 101% of the pre-BTO state. The remaining five patients showed severe neurologic symptoms such as transient hemiplegia and unconsciousness. Their comparative uptake of the middle cerebral artery territories were 77 to 85% of the pre-BTO state, and were well matched with other factors. $^{99m}Tc$-HMPAO brain SPECT before and during BTO seems to be a simple and objective method for prediction of permanent neurologic deficits when the comparative uptake of middle cerebral artery territories during BTO is lower than 85% of that before BTO.

  • PDF

The comparisons of three scatter correction methods using Monte Carlo simulation (몬테카를로 시뮬레이션을 이용한 산란보정 방법들에 대한 비교)

  • 봉정균;김희중;이종두;권수일
    • Progress in Medical Physics
    • /
    • v.10 no.2
    • /
    • pp.73-81
    • /
    • 1999
  • Scatter correction for single photon emission computed tomography (SPECT) plays an important role to improve image quality and quantitation. The purpose of this study was to investigate three scatter correction methods using Monte Carlo simulation. Point source and Jaszack phantom filled with Tc-99m were simulated by Monte Carlo code, SIMIND. For scatter correction, we applied three methods, Compton window (CW) method, triple window (TW) method, and dual photopeak window (DPW) method. Point sources located at various depths along the center line within a 20-cm phantom were simulated to calculate the window ratios and corresponding scatter fractions by evaluating the polynomial coefficients for DPW method. Energy windows were located in W$_1$=92-125 keV, W$_2$=124-126 keV, W$_3$=136-140 keV, W$_4$=140-141 keV, and W$_{5}$=154-156 keV. The results showed that in Jaszack phantom with cold sphere and hot sphere, the TW gave the closest contrast and percentage recovery to the ideal image, respectively, while CW overestimated and DPW underestimated the contrast of ideal one. All three scatter correction methods showed an improved image contrast. In conclusion, scatter correction is essential for improving image contrast and accurate quantification. The choice of scatter correction method should be made on the basis of accuracies and ease of implementation.

  • PDF

Compared Performance of Semiconductor SPECT in Myocardial Perfusion SPECT: Phantom study (범용 신틸레이터 감마카메라와 심근전용 반도체 감마카메라의 성능 비교 연구)

  • Bahn, Young Kag;Hwang, Dong Hoon;Kim, Jung Yul;Kang, Chun Koo;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.49-53
    • /
    • 2016
  • Purpose Recently, Cadmium-zinc-telluride (CZT) semiconductor myocardial SPECT (Single Photon Emission Computed Tomography) has been used myocardial scintigraphy. In this study, the performance of Semiconductor SPECT and conventional SPECT systems was compared by a comprehensive analysis of phantom SPECT images. Materials and Methods Methods: We evaluated the DSPECT CZT SEPCT (Spectrum-dynamic) and INFINA conventional (GE). Physical performance was compared on reconstructed SPECT images from a phantom. Results For count sensitivity on cardiac phantom images ($counts{\cdot}sec^{-1}{\cdot}MBq^{-1}$), DSPECT had a sensitivity of conventional SPECT. This classification was similar to that of myocardial counts normalized to injected activities from phantom images (respective mean values, $counts{\cdot}sec^{-1}{\cdot}MBq^{-1}$: 195.83 and 52.83). For central spatial resolution: DSPECT, 9.47mm; conventional SPECT, 16.90mm. For contrast-to-noise ratio on the phantom: DSPECT, 4.2; conventional SPECT, 3.6. Conclusion The performance of CZT cameras is dramatically higher than that of conventional SPECT. However, CZT cameras differ in that spatial resolution and contrast-to-noise ratio are better with conventional SPECT, whereas count sensitivity is markedly higher with the DSPECT.

  • PDF

Venous Congestion in Cerebral Hyperperfusion Syndrome: A Case Report (뇌과관류증후군에서 보일 수 있는 정맥울혈 1례)

  • Bong, Jeong Bin;Kang, Hyun Goo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.8
    • /
    • pp.84-87
    • /
    • 2017
  • Cerebral hyperperfusion syndrome (CHS) is a rare complication that can occur when conducting stent insertion or endarterectomy in patients with carotid artery stenosis and is known to be caused by various mechanisms when the blood volume abruptly increases. The main clinical symptoms are unilateral headache, hypertension, seizure, and focal neurologic deficit. Subarachnoid hemorrhage and parenchymal hemorrhage may lead to permanent impairment or death in severe cases. CHS can be predicted by using transcranial Doppler, perfusion magnetic resonance imaging, and single photon emission computed tomography. In our case report, a patient developed CHS subsequent to significant venous congestion caused by carotid artery stent insertion. The patient had preexisting, symptomatic bilateral carotid artery stenosis. Venous congestion occurs when the direction of blood flow changes because of increased blood volume in patients with well-developed collateral vessels. We believe that CHS can be predicted from this finding. This study reports the possibility that CHS could be confirmed by cerebral angiography after insertion of the internal carotid stent.