• Title/Summary/Keyword: Tomography, computed

Search Result 5,324, Processing Time 0.029 seconds

Accessory mental foramen: A rare anatomical variation detected by cone-beam computed tomography

  • Torres, Marianna Guanaes Gomes;Valverde, Ludmila De Faro;Vidal, Manuela Torres Andion;Crusoe-Rebello, Ieda Margarida
    • Imaging Science in Dentistry
    • /
    • v.45 no.1
    • /
    • pp.61-65
    • /
    • 2015
  • The mental foramen is a bilateral opening in the vestibular portion of the mandible through which nerve endings, such as the mental nerve, emerge. In general, the mental foramen is located between the lower premolars. This region is a common area for the placement of dental implants. It is very important to identify anatomical variations in presurgical imaging exams since damage to neurovascular bundles may have a direct influence on treatment success. In the hemimandible, the mental foramen normally appears as a single structure, but there are some rare reports on the presence and number of anatomical variations; these variations may include accessory foramina. The present report describes the presence of accessory mental foramina in the right mandible, as detected by cone-beam computed tomography before dental implant placement.

Removal of a broken needle using three-dimensional computed tomography: a case report

  • Kim, Jin-Ha;Moon, Seong-Yong
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.39 no.5
    • /
    • pp.251-253
    • /
    • 2013
  • Inferior alveolar nerve block obtained maximum anesthetic effect using a small dose of local anesthetic agent, which also has low a complication incidence. Complications of an inferior alveolar nerve block include direct nerve damage, bleeding, trismus, temporary facial nerve palsy, and etc. Among them, the major iatrogenic complication is dental needle fracture. A fragment that disappears into the soft tissue would be hard to remove, giving rise to a legal problem. A 31-year-old woman was referred for the removal of a broken needle, following an inferior alveolar nerve block. Management involved the removal of the needle under local anesthesia with pre- and peri-operative computed tomography scans.

Case Report of a Simple Rib Fracture Caused by Coughing (기침으로 초래된 단순 늑골골절 1례)

  • Choi, Woo-Ik
    • Journal of Trauma and Injury
    • /
    • v.27 no.1
    • /
    • pp.9-12
    • /
    • 2014
  • Violent or severe persistent coughing is rarely associated with rib fracture. We report a rare case of a cough-induced rib fracture in a patient without any traumatic history or any other underlying disease. A 32-year-old female presented to the emergency department complaining of having had right-sided pleuritic chest pain for 5 days. She had a background of an 8-week coughing illness. A posteroanterior view of the chest radiograph showed no definite fractured line. Chest computed tomography revealed a subtle break cortical line of the 7th rib in the right-sided chest wall. Early identification of a cough-induced fracture of the rib by using computed tomography may avoid unnecessary further work-ups including laboratory examination and may lead to appropriate discharge instructions including rest and reassurance. The clinical presentations and radiologic findings of rib fractures caused by coughing are presented along with a review of the literature.

Three-dimensional cone-beam computed tomography based comparison of condylar position and morphology according to the vertical skeletal pattern

  • Park, In-Young;Kim, Ji-Hyun;Park, Yang-Ho
    • The korean journal of orthodontics
    • /
    • v.45 no.2
    • /
    • pp.66-73
    • /
    • 2015
  • Objective: To compare condylar position and morphology among different vertical skeletal patterns. Methods: Diagnostic cone-beam computed tomography images of 60 adult patients (120 temporomandibular joints) who visited the orthodontic clinic of Hallym University Sacred Heart Hospital were reviewed. The subjects were divided into three equal groups according to the mandibular plane angle: hypodivergent, normodivergent, and hyperdivergent groups. Morphology of the condyle and mandibular fossa and condylar position were compared among the groups. Results: The hypodivergent and hyperdivergent groups showed significant differences in superior joint spaces, antero-posterior condyle width, medio-lateral condyle width, condyle head angle, and condylar shapes. Conclusions: Condylar position and morphology vary according to vertical facial morphology. This relationship should be considered for predicting and establishing a proper treatment plan for temporomandibular diseases during orthodontic treatment.

Multiple idiopathic external and internal resorption: Case report with cone-beam computed tomography findings

  • Celikten, Berkan;Uzuntas, Ceren Feriha;Kurt, Hakan
    • Imaging Science in Dentistry
    • /
    • v.44 no.4
    • /
    • pp.315-320
    • /
    • 2014
  • Root resorption is loss of dental hard tissue as a result of clastic activities. The dental hard tissue of permanent teeth does not normally undergo resorption, except in cases of inflammation or trauma. However, there are rare cases of tooth resorption of an unknown cause, known as "idiopathic root resorption". This report would discuss a rare case of multiple idiopathic resorption in the permanent maxillary and mandibular teeth of an otherwise healthy 36-year-old male patient. In addition to a clinical examination, the patient was imaged using conventional radiography and cone-beam computed tomography (CBCT). The examinations revealed multiple external and internal resorption of the teeth in all four quadrants of the jaws with an unknown cause. Multiple root resorption is a rare clinical phenomenon that should be examined using different radiographic modalities. Cross-sectional CBCT is useful in the diagnosis and examination of such lesions.

Computed Tomography-Aided Diagnosis of Nasal Adenocarcinoma Treated with Rhinotomy and Radiation Therapy in a Dog (CT 진단 후 비절개술 및 방사선요법으로 치료한 개의 비강 선암의 발생례)

  • 홍성혁;김명철
    • Journal of Veterinary Clinics
    • /
    • v.19 no.2
    • /
    • pp.256-259
    • /
    • 2002
  • A 39 kg, 7-year-old male Labrador Retriever dog with a 3-month history of epistaxis, sneezing, and nasal discharge was referred to the Veterinary Medical Center of the Tokyo University. On the plain X-ray and computed tomography (CT) of the head showed increased density of the soft tissue in the left nasal cavity and the tumor infiltrated to nasal septum. The tumor mass removed by rhinotomy. Histopathological examination of the mass revealed adenocarcinoma. Four weeks after the surgery, the radiation therapy was performed twice a week for f weeks. 4 months after surgery, the dog had a recurrence in nasal cavity and administered carboplatin 300 mg/$m^2$ twice. However, the tumor had no response to chemotherapy, additional surgery and additional radiation therapy, and the dog was euthanized at the owner's request. At necropsy, metastatic proliferation was confirmed in the lung, lymph nodes and nasal cavity.

Patient Radiation Exposure Dose in Computed Tomography (전산화단층촬영장치에서 환자피폭선량)

  • Cho, Pyong Kon
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.2
    • /
    • pp.109-115
    • /
    • 2015
  • In case of a CT examinations, there is a difference in the distribution of radiation dose from that of general X-ray equipments, and it has been known to cause a great radiation exposure during the examinations. However, owing to its high reliability on the accuracy of a examinations result, its use has increased continuously. In consideration of such a circumstance, the CT equipment, radiation dose during CT examinations, diagnostic reference level, and solutions to reduce radiation dose were mentioned on the basis of previously reported data.

Communication Bronchopulmonary Malformation (교통성 폐격리증 -1례 보고-)

  • 김종호
    • Journal of Chest Surgery
    • /
    • v.28 no.12
    • /
    • pp.1183-1187
    • /
    • 1995
  • We have experienced a case of communicating bronchopulmonary malformation. A 35-year-old female patient was admitted for coughing with sputum. About eight years ago, she had treated for bronchiectasis with medication. Chest computed tomography revealed esophagopulmonary communication with upper esophageal dilatation and bronchiectasis of the left lower lobe. A about 3 mm diameteded abnormal feeding vessel from descending thoracic aorta to the left lower lobe was detected at operation. Division and closure of the communication between the esophagus and left lower lobe was performed. Communicating bronchopulmonary malformation is the rare form of pulmonary sequestion and chest computed tomography is one of the useful diagnostic methods for pulmonary sequestion.

  • PDF

Cone-beam computed tomography: Time to move from ALARA to ALADA

  • Jaju, Prashant P.;Jaju, Sushma P.
    • Imaging Science in Dentistry
    • /
    • v.45 no.4
    • /
    • pp.263-265
    • /
    • 2015
  • Cone-beam computed tomography (CBCT) is routinely recommended for dental diagnosis and treatment planning. CBCT exposes patients to less radiation than does conventional CT. Still, lack of proper education among dentists and specialists is resulting in improper referral for CBCT. In addition, aiming to generate high-quality images, operators may increase the radiation dose, which can expose the patient to unnecessary risk. This letter advocates appropriate radiation dosing during CBCT to the benefit of both patients and dentists, and supports moving from the concept of "as low as reasonably achievable" (ALARA) to "as low as diagnostically acceptable" (ALADA).

Evaluation of Radiation Dose Reduction from the Automatic Exposure Control Technique in Different Manufactures Multi-Detector Computed Tomography (제조사별 다중 검출기 컴퓨터단층촬영 장비의 관전류 자동노출조절 기법의 방사선량 감소 평가)

  • Kim, Yeong-Ok;Seong, Yeol-Hun
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2011.11a
    • /
    • pp.563-571
    • /
    • 2011
  • The purpose of the study was to evaluation of the radiation dose reduction using various automatic exposure control (AEC) systems in different manufactures multi-detector computed tomography (MDCT). We used three different manufacturers for the study: General Electric Healthcare, Philips Medical systems and Siemens Medical Solutions. The general scanning protocol was created for the each examination with the same scanning parameters as many as possible. In the various AEC systems, the evaluation of reduced-dose was evaluated by comparing to fixed mAs with using body phantom. Finally, when we applied to AEC for three manufacturers, the radiation dose reduction decreased each 35.3% in the GE, 58.2% in the Philips, and 48.6% in the Siemens. This applies to variety of the AEC systems which will be very useful to reduce the dose and to maintain the high quality.

  • PDF