• Title/Summary/Keyword: Tomographic Reconstruction

Search Result 96, Processing Time 0.027 seconds

Implications of abnormal abdominal wall computed tomographic angiography findings on postmastectomy free flap breast reconstruction

  • Ngaage, Ledibabari Mildred;Hamed, Raed R.;Oni, Georgette;Ghorra, Dina T.;Ang, Jolenda Z.;Koo, Brendan C.;Benyon, Sarah L.;Irwin, Michael S.;Malata, Charles M.
    • Archives of Plastic Surgery
    • /
    • v.47 no.2
    • /
    • pp.146-152
    • /
    • 2020
  • Background Preoperative computed tomography angiography (CTA) of the abdominal wall vessels is used when planning free flap breast reconstruction (FFBR) because it provides a surgical road map which facilitates flap harvest. However, there are few reports on the effect of abnormal findings on the operative plan. Methods We conducted a retrospective study of all FFBRs performed at a tertiary referral center over a 6-year period (November 2011 to June 2017). One consultant radiologist reported on the findings. Details on patient demographics, CTA reports, and intraoperative details were collected. Results Two hundred patients received preoperative CTAs. Fourteen percent of patients (n=28) had abnormal findings. Of these findings, 18% were vascular anomalies; 36% tumorrelated and 46% were "miscellaneous." In four patients, findings subsequently prevented surgery; they comprised a mesenteric artery aneurysm, absent deep inferior epigastric (DIE) vessels, bilateral occluded DIE arteries, and significant bone metastases. Another patient had no suitable vessels for a free flap and the surgical plan converted to a pedicled transverse rectus abdominis musculocutaneous flap. The remaining incidental findings had no impact on the surgical plan or appropriateness of FFBR. More than one in 10 of those with abnormal findings went on to have further imaging before their operation. Conclusions CTA in FFBR can have a wider impact than facilitating surgical planning and reducing operative times. Incidental findings can influence the surgical plan, and in some instances, avoid doomed-to-fail and unsafe surgery. It is therefore important that these scans are reported by an experienced radiologist.

Precise System Models using Crystal Penetration Error Compensation for Iterative Image Reconstruction of Preclinical Quad-Head PET

  • Lee, Sooyoung;Bae, Seungbin;Lee, Hakjae;Kim, Kwangdon;Lee, Kisung;Kim, Kyeong-Min;Bae, Jaekeon
    • Journal of the Korean Physical Society
    • /
    • v.73 no.11
    • /
    • pp.1764-1773
    • /
    • 2018
  • A-PET is a quad-head PET scanner developed for use in small-animal imaging. The dimensions of its volumetric field of view (FOV) are $46.1{\times}46.1{\times}46.1mm^3$ and the gap between the detector modules has been minimized in order to provide a highly sensitive system. However, such a small FOV together with the quad-head geometry causes image quality degradation. The main factor related to image degradation for the quad-head PET is the mispositioning of events caused by the penetration effect in the detector. In this paper, we propose a precise method for modelling the system at the high spatial resolution of the A-PET using a LOR (line of response) based ML-EM (maximum likelihood expectation maximization) that allows for penetration effects. The proposed system model provides the detection probability of every possible ray-path via crystal sampling methods. For the ray-path sampling, the sub-LORs are defined by connecting the sampling points of the crystal pair. We incorporate the detection probability of each sub-LOR into the model by calculating the penetration effect. For comparison, we used a standard LOR-based model and a Monte Carlo-based modeling approach, and evaluated the reconstructed images using both the National Electrical Manufacturers Association NU 4-2008 standards and the Geant4 Application for Tomographic Emission simulation toolkit (GATE). An average full width at half maximum (FWHM) at different locations of 1.77 mm and 1.79 mm are obtained using the proposed system model and standard LOR system model, which does not include penetration effects, respectively. The standard deviation of the uniform region in the NEMA image quality phantom is 2.14% for the proposed method and 14.3% for the LOR system model, indicating that the proposed model out-performs the standard LOR-based model.

Cone-beam computed tomographic reconstructions in the evaluation of maxillary impacted canines

  • David MacDonald;Sharifa Alebrahim;Edwin Yen;Jolanta Aleksejuniene
    • Imaging Science in Dentistry
    • /
    • v.53 no.2
    • /
    • pp.145-151
    • /
    • 2023
  • Purpose: Prior to cone-beam computed tomography (CBCT), orthodontic competence included radiological interpretation. Nevertheless, maxillary impacted canines (MICs), because of their position and adjacent complex anatomy, have been challenging to interpret, particularly with regard to root resorption. Although CBCT cross-sectional reconstructions of MICs yielded clearer insights into its diagnosis and treatment planning, the value of simultaneously using 2 different cross-sectional or multiplanar reconstructions of the CBCT datasets - orthogonal and curved/panoramic multiplanar reconstructions - has hitherto not been considered. Materials and Methods: Both orthogonal and curved/panoramic multiplanar reconstruction series of 5 screenshots were each reconstructed from the 5 cm×5 cm CBCT datasets of 15 separate MICs. Fifteen credentialled and experienced orthodontist volunteers reviewed 2 separate PowerPoints of 15 randomized series each, 1 week apart. Their review considered 6 factors that could affect treatment: the position and level of the MIC, the presence or absence of root resorption, ankylosis, cysts, and dilaceration. Results: All 15 orthodontists were statistically similar regarding overall years of experience and of CBCT use. Although either reconstruction alone allowed the orthodontists to determine whether ankylosis and, to a lesser extent, most of the other features were present or absent in the MIC, reviewing both reconstructions together was necessary to determine whether root resorption was present or absent in the adjacent tooth. Conclusion: Reviewing both orthogonal and curved/panoramic multiplanar reconstructions was necessary to evaluate the presence or absence of root resorption in the teeth adjacent to MICs and that of many other features.

Quantitative Analysis of Artifactual Perfusion Defects due to the Cutoff Frequencies of Reconstruction Filters in Tc-99m-MIBI Myocardial SPECT Images (Tc-99m-MIBI 심근 SPECT에서 재구성필터의 차단주파수에 의한 인위적 관류결손의 정량적 평가)

  • Kwark, Cheol-Eun;Chung, June-Key;Lee, Myung-Chul
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.2
    • /
    • pp.231-238
    • /
    • 1995
  • Tc-99m-MIBI (Sestamibi) myocardial SPECT along with TI-201 tomographic Imaging has demonstrated wide application and high image quality sufficient for the diagnosis of myocardial perfusion defect, which consequently reflects regional myocardial blood flow. The qualitative values of myocardial SPECT with Tc-99m-MIBI as well ds the quantitative cases depend in some degree on the reconstruction techniques of multiple projections. Filtered backprojection (FBP) Is the common standard method for reconstruction rather than the complicated and time-consuming arithmetic methods. In FBP it is known that the distribution of radioactivity in reconstructed transverse slices varies with the selected litter parameters such as cutoff frequencies and order (Butterworth case) The cutoff frequencies used in clinicAl practice partially remove and decrease the true radioactive distribution and alter the pixel counts, which lead to underestimation of true counts in specific myocardial regions. In this study, we have investigated the effect of cutoff frequencies of reconstruction filter on the artifactually induced perfusion defects, which are often demonstrated near inferior and/or inferoseptal cardiac walls due to the intense hepatic uptake of Tc-99m-MIBI. A computerized method for Identifying the relative degree of artifactual perfusion defect and for comparing those degrees along with the relative amount of hepatic uptake to myocardium was developed and patient images were studied to observe the quantitative degree of underestimation of myocardial perfusion, and to propose some reasonable threshold of cutoff frequency in the diagnosis of perfusion defect quantitatively. We concluded that from the quantitative viewpoint cutoff frequencies may be used as high as possible with the sacrifice of homogeneity of image quality, and those frequencies lower than the common 0.3 Wyquist frequency would reveal severe degradation of radioactive distribution near inferior and/or inferoseptal myocardium when applying Butterworth or low pass filter.

  • PDF

Morphology of the Aging Forehead: A Three-Dimensional Computed Tomographic Study

  • Yi, Hyung Suk
    • Archives of Craniofacial Surgery
    • /
    • v.16 no.2
    • /
    • pp.58-62
    • /
    • 2015
  • Background: Age-related changes have been studied for lower and middle facial bones. Although the forehead comprises one-third of the facial area, no studies have investigated age-related changes in the upper part of the face or forehead. The purpose of this study was to use three-dimensional computed tomography (3D CT) to investigate age-related changes in the frontal bone. Methods: A retrospective review was performed for patients who underwent 3D CT scan of facial bones. Patients were divided by gender and age (20 to 40 years, 41 to 60 years, and above 60 years). The frontal bone curvature was evaluated by the length of frontal bone and by two frontal bone angles in relation to the Frankfurt horizon. Results: In both genders, aging was associated with increasing lower slope length. In elderly men (>60 years), the upper slope angle was significantly higher when compared to younger male subjects. Women demonstrated similar age-related changes, but the differences were only statistically significant for the middle and older age groups. Conclusion: This study demonstrates quantifiable age-related changes in the frontal bone. These findings contribute to the understanding of age-related changes of the facial soft tissues. The mean measurements in each age group can be used as a reference when planning forehead reconstruction.

Computed Tomographic Characteristics Of Nasal Squamous Cell Carcinoma In a Dog (개의 비강 편평상피세포종의 컴퓨터단층촬영상의 특징)

  • 권정국;송경진;이기창;이희천;최민철
    • Journal of Veterinary Clinics
    • /
    • v.20 no.3
    • /
    • pp.399-402
    • /
    • 2003
  • A female unknown aged Yorkshire terrier, weighing 3.5 kg with nasal discharge, left facial swelling and severe inflammation was referred to Veterinary Medical Teaching Hospital, Seoul National University. Radiographic findings were lytic change and soft tissue swelling of left zygomatic process and increased radiopacity of nasal cavity. In computed tomography, turbinate bone destruction was observed as well as lytic change of left zygomatic process and left maxilla indicating aggressive lesion. Then 3-dimensional reconstruction was also performed. Biopsy of tissue mass revealed it as squamous cell carcinoma. For this patient, euthanasia was performed guarded prognosis. Generally, tumors of the nasal cavity in dogs account for approximately 1 % to 2% of all neoplasms. The prevalence of these tumors increased with age and exposure to the ultraviolet. About two thirds of all nasal tumors are malignant tumors such as squamous cell carcinoma and adenocarcinoma. As these tumors of nasal cavity are locally invasive, and external beam radiotherapy is the current treatment of choice. Unfortunately, diagnosis of these tumors often occurs late in the course of disease, resulting in a poor prognosis for outcome in many patients. It is considered that computed tomography could be used as an aid modality for the exact evaluation of extend and degree of bone lysis of nasal cavity and metastasis.

Measurement of facial soft tissues thickness using 3D computed tomographic images (3차원 전산화단층찰영 영상을 이용한 얼굴 연조직 두께 계측)

  • Jeong Ho-Gul;Kim Kee-Deog;Han Seung-Ho;Shin Dong-Won;Hu Kyung-Seok;Lee Jae-Bum;Park Hyok;Park Chang-Seo
    • Imaging Science in Dentistry
    • /
    • v.36 no.1
    • /
    • pp.49-54
    • /
    • 2006
  • Purpose : To evaluate accuracy and reliability of program to measure facial soft tissue thickness using 3D computed tomographic images by comparing with direct measurement. Materials and Methods : One cadaver was scanned with a Helical CT with 3 mm slice thickness and 3 mm/sec table speed. The acquired data was reconstructed with 1.5 mm reconstruction interval and the images were transferred to a personal computer. The facial soft tissue thickness were measured using a program developed newly in 3D image. For direct measurement, the cadaver was cut with a bone cutter and then a ruler was placed above the cut side. The procedure was followed by taking pictures of the facial soft tissues with a high-resolution digital camera. Then the measurements were done in the photographic images and repeated for ten times. A repeated measure analysis of variance was adopted to compare and analyze the measurements resulting from the two different methods. Comparison according to the areas was analyzed by Mann-Whitney test. Results : There were no statistically significant differences between the direct measurements and those using the 3D images (p>0.05). There were statistical differences in the measurements on 17 points but all the points except 2 points showed a mean difference of 0.5 mm or less. Conclusion : The developed software program to measure the facial soft tissue thickness using 3D images was so accurate that it allows to measure facial soft tissues thickness more easily in forensic science and anthropology.

  • PDF

Clinical usefulness of facial soft tissues thickness measurement using 3D computed tomographic images (3차원 전산화단층촬영 영상을 이용한 안면 연조직 두께 계측의 임상적 유용성)

  • Jeong Ho-Gul;Kim Kee-Deog;Han Seung-Ho;Hu Kyung-Seok;Lee Jae-Bum;Park Hyok;Choi Seong-Ho;Kim Chong-Kwan;Park Chang-Seo
    • Imaging Science in Dentistry
    • /
    • v.36 no.2
    • /
    • pp.89-94
    • /
    • 2006
  • Purpose : To evaluate clinical usefulness of facial soft tissue thickness measurement using 3D computed tomographic images. Materials and Methods : One cadaver that had sound facial soft tissues was chosen for the study. The cadaver was scanned with a Helical CT under following scanning protocols about slice thickness and table speed; 3 mm and 3 mm/sec, 5 mm and 5 mm/sec, 7 mm and 7 mm/sec. The acquired data were reconstructed 1.5, 2.5, 3.5 mm reconstruction interval respectively and the images were transferred to a personal computer. Using a program developed to measure facial soft tissue thickness in 3D image, the facial soft tissue thickness was measured. After the ten-time repeation of the measurement for ten times, repeated measure analysis of variance (ANOVA) was adopted to compare and analyze the measurements using the three scanning protocols. Comparison according to the areas was analyzed by Mann-Whitney test. Results : There were no statistically significant intraobserver differences in the measurements of the facial soft tissue thickness using the three scanning protocols (p>0.05). There were no statistically significant differences between measurements in the 3 mm slice thickness and those in the 5 mm, 7 mm slice thickness (p>0.05). There were statistical differences in the 14 of the total 30 measured points in the 5 mm slice thickness and 22 in the 7 mm slice thickness. Conclusion : The facial soft tissue thickness measurement using 3D images of 7 mm slice thickness is acceptable clinically, but those of 5 mm slice thickness is recommended for the more accurate measurement.

  • PDF

Implementation of Multi-channel Concurrent Detection Homodyne Frequency-domain Diffuse Optical Imaging System (다채널 동시측정을 적용한 호모다인 주파수영역 확산 광 이미징 시스템의 구현)

  • Jun, Young Sik;Baek, Woon Sik
    • Korean Journal of Optics and Photonics
    • /
    • v.23 no.1
    • /
    • pp.23-31
    • /
    • 2012
  • In this paper, we developed a frequency-domain diffuse optical imaging (DOI) system for imaging non-invasively using near-infrared (NIR) light sources and detectors. 70-MHz modulation and a homodyne scheme were adopted. By calibration of the coupling coefficients, concurrent detection measurements by 4 detector sets were optimized. We presented experimental reconstruction images of absorption and scattering coefficients in a liquid phantom, located an anomaly in the phantom and determined its optical properties. The images by the multi-channel concurrent detection were improved over the results by single-channel sequential detection. Tomographic slices of absorption and scattering coefficients in the phantom with an anomaly were also presented.

Computerized Tomographic Measurements of Morphometric Parameters of the C2 for the Feasibility of Laminar Screw Fixation in Korean Population

  • Kim, Young-June;Rhee, Woo-Tack;Lee, Sang-Bok;You, Seung-Hoon;Lee, Sang-Youl
    • Journal of Korean Neurosurgical Society
    • /
    • v.44 no.1
    • /
    • pp.15-18
    • /
    • 2008
  • Objective : C2 laminar screw fixation is considered as an excellent alternative to Magerl's transfacetal approach or Harms construct for the atlantoaxial stabilization. However, to our knowledge, there is no report on the feasibility of the new approach to Korean population. We investigated morphometric parameters of the dorsal arch of the C2 to provide the quantitative data for the feasibility of laminar screw fixation. Methods : One-hundred-and-two patients' cervical computed tomography had been reconstructed and investigated on the anatomical parameters related with C2 laminar screw placement. Sixty patients were male and forty-two patients were female. Measurements included the laminar thickness and slope, spino-laminar angle, and maximal screw length. Results : Ages ranged from 20 to 81 and the mean age was 48.4. Mean laminar thickness was 5.7 mm (${\pm}1.0$) (5.8 mm in male and 5.4 mm in female). Fifty-one patients (50%) had a laminar thickness smaller than 5.5 mm at least unilaterally, therefore the patients were considered as inappropriate candidates for the laminar screw fixation in the smaller side of the laminae. Mean value of maximal length of screw was 33.3 mm (34.3 mm in male and 31.9 mm in female). Mean spino-laminar angle was $43.2^{\circ}$ and mean slope angle was $32.9^{\circ}$. Conclusion : Half of patients had inappropriate laminar profiles to accommodate a 3.5 mm screw in at least one side of the axis. The three-dimensional computed tomography reconstruction is mandatory for the preoperative assessment for the feasibility of the C2 lamina.