• Title/Summary/Keyword: Toe

Search Result 1,124, Processing Time 0.021 seconds

Impact Shock Components and Attenuation in Flat Foot Running (편평족 달리기 시 충격 쇼크의 성분과 흡수)

  • Ryu, Ji-Seon;Lim, Ga-Young
    • Korean Journal of Applied Biomechanics
    • /
    • v.25 no.3
    • /
    • pp.283-291
    • /
    • 2015
  • Objective : The purpose of this study was to determine the differences in the head and tibial acceleration signal magnitudes, and their powers and shock attenuations between flat-footed and normal-footed running. Methods : Ten flat-footed and ten normal-footed subjects ran barefoot on a treadmill with a force plate at 3.22m/s averaged from their preferred running speed using heel-toe running pattern while the head and tibial acceleration in the vertical axis data was collected. The accelerometers were sampled at 2000 Hz and voltage was set at 100 mv, respectively. The peak magnitudes of the head and tibial acceleration signals in time domain were calculated. The power spectral density(PSD) of each signal in the frequency domain was also calculated. In addition to that, shock attenuation was calculated by a transfer function of the head PSD relative to the tibia PSD. A one-way analysis of variance was used to determine the difference in time and frequency domain acceleration variables between the flat-footed and normal-footed groups running. Results : Peaks of the head and tibial acceleration signals were significantly greater during flat-footed group running than normal-footed group running(p<.05). PSDs of the tibial acceleration signal in the lower and higher frequency range were significantly greater during flat-footed running(p<.05), but PSDs of the head acceleration signal were not statistically different between the two groups. Flat-footed group running resulted in significantly greater shock attenuation for the higher frequency ranges compared with normal-footed group running(p<.05). Conclusion : The difference in impact shock magnitude and frequency content between flat-footed and normal-footed group during running suggested that the body had different ability to control impact shock from acceleration. It might be conjectured that flat-footed running was more vulnerable to potential injury than normal-footed running from an impact shock point of view.

The Effects of Age and Walkway Type on Lower Extremities Kinematics in Elderly Women (보행로 형태가 여성노인들의 하지관절에 미치는 영향)

  • Woo, Byung-Hoon;Park, Yang-Sun
    • Korean Journal of Applied Biomechanics
    • /
    • v.25 no.3
    • /
    • pp.249-256
    • /
    • 2015
  • Objective : The purposes of this study was to perform a kinematical analysis on age and walkway types in elderly women subjects. Method : Forty subjects participated in the experiment (A1 group - age: $67.30{\pm}1.49yrs$, height: $153.81{\pm}4.47cm$, weight: $61.80{\pm}5.24kg$, A2 group - age: $71.70{\pm}1.10yrs$, height: $152.01{\pm}2.84cm$, weight: $59.69{\pm}7.34kg$, A3 group - age: $76.80{\pm}0.98yrs$, height: $150.16{\pm}6.08cm$, weight: $57.27{\pm}6.42kg$, A4 group - age: $81.80{\pm}0.60yrs$, height: $152.18{\pm}4.77cm$, weight: $55.80{\pm}7.78kg$). The study method adopted was the 3D analysis with six cameras. Ground type were classifed as gait pattern on flat, ascent and descent ramp. For the statistical analysis, the SPSS 21.0 was used to perform Repeated measured Two-way ANOVA. Results : In velocity of CM, there was faster movement on flat ground. When it came to the velocity of right toe, there was no significance in early mid-swing of right foot, but A4 was the slowest in late mid-swing of right foot on flat ground. In joint angle in left foot strike, the left hip joint and knee joint were more flexed in descent ramp, In addition left and right ankle joints were more plantarflexed in descent ramp, and left ankle joint was more plantarflexed in the over 75 yrs age groups. Conclusion : The higher age group were more flexed in lower body joints during descent ramp.

Biomechanical Analysis of Men's High Jump Medalists in IAAF World Championships, Daegu 2011 (2011 대구세계육상선수권대회 남자 높이뛰기 메달리스트들의 바이오메카닉스적 특성 분석)

  • Kim, Eui-Hwan;Bae, Young-Sang;Kim, Sung-Sup;Kwon, Moon-Seok;Wi, Ung-Ryang;KIm, Ki-Man;Lee, Jeong-Min
    • Korean Journal of Applied Biomechanics
    • /
    • v.21 no.5
    • /
    • pp.573-584
    • /
    • 2011
  • The purpose of this study was to perform a kinematic analysis of the high jump techniques of the three men's medalists at the 2011 IAAF Championships in Daegu (August 27-September 4, 2011). In particular, a three-dimensional coordinates method was used to analyze the last three strides before touchdown, the touchdown techniques, and the movements after takeoff toward the bar. An analysis of the, data for the biomechanical characteristics of the world's best high jumpers could contribute to an improvement in the performance of a national high jumper. The first conclusion of the data analysis was that the arm movements of the gold medalist, J. Williams, had a single arm form, whereas the arm movements of the other medalists were a double arm form. Second, the difference in the knee joint angles upon touchdown and toe-off was $10^{\circ}$. Third, J. Williams achieved his maximum CM height after takeoff (1.26 m) using the maximum flexion of his knee joint. Fourth, the foot contact duration of A. Dmitrik (0.11 s) was the shortest among the medalists, and the ratio for his transformation of horizontal velocity to vertical velocity was the greatest (75.25%) among the three. Last, the maximum CM height of T. Barry was the greatest, and his foot contact duration was the longest.

Quantitative and Qualitative Differences according to the Shoe Type for the Grand Jete Landing in Ballet

  • Yi, Kyung-Ok;Park, Hye-Rhee
    • Korean Journal of Applied Biomechanics
    • /
    • v.21 no.1
    • /
    • pp.25-29
    • /
    • 2011
  • The purpose of this study was to analyze quantitative and qualitative differences according to shoe type for the grand jete landing in ballet. The subjects for this study were 9 female ballet majors with an average of 12 years of experience. Subjects jumped, performing a front split, and landed on 1 foot, a movement called the grand jete. Analysis was performed on the students' landing. Independent variables were 3 shoe types: split sole, traditional out sole, and 5-toed forefoot shoes, with bare feet as a control group. Dependent variables were vertical passive ground reaction force and qualitative elements. Passive ground reaction force variables(maximum passive peak value, number of passive peaks, passive force-time integral, and center of pressure) were measured by the Kistler 9281B Force Platform. Qualitative elements were comfort, cushioning, pain, and fit. Statistical analysis included both 1-way ANOVA and Tukey's test for follow-up. Finalized data demonstrated that the 5-toed forefoot shoe allows the forefoot to expand and the toes to individually press down upon landing, increasing foot contact with the surface. Five-toed forefoot shoes minimize passive peaks and pain, while increasing comfort, cushioning, and fit. Most ballet movements are composed of jumping, balancing, landing, and spinning. Wearing 5-toed forefoot shoes allows for a natural range of movement in each toe, to improve both technique and balance. Pain and injuries from ballet can be minimized by wearing the correct shoe type. According to this analysis, it is possible to customized ballet shoes to increase the efficiency of techniques and movements.

Comparative Analysis on Gait Patterns of the Elderly and the Young Regarding to Foot Pressure (고령자와 청장년층의 발바닥 압력분포에 따른 보행패턴 비교 분석)

  • Lee, Kyung-Deuk;Kim, Dae-Woong;Yoo, Jung-Hyeon;Kim, Kyung-Hun;Lee, Tae-Yong;Park, Kwang-Suk;Chung, Gih-Sung;Park, Seung-Bum
    • Korean Journal of Applied Biomechanics
    • /
    • v.21 no.1
    • /
    • pp.67-75
    • /
    • 2011
  • The purpose of this study was to find the difference in gait patterns when elderly and young people walk by analyzing COP, Gait Line, Foot pressure pattern, and ensuring the original biomechanics technology of developing high performance footwear for the elderly. The subjects who took part in the test consist of 20 elderly people and 20 young people. The physical features of the elderly people that were recruited for the study are as below: 20 healthy male subjects(elderly people) with an average age of 75.43 yrs(S.D 6.46 yrs), weight of 68.10 kg(S.D 0.94 kg) and a height of 168.65 cm(S.D 1.47 cm). Foot pressure pattern data was collected using a EMED-AT system(Novel Gmbh, Germany) operating at the 50 Hz during walking. The results are as follow : COP route of the elderly leans to lateral compared to the young, and Gait Line from heel to toe is not clear and laterally curved. At the same time, a contact are aonthe midfoot is high compared to the young, and maximum force of the forefoot is low. As a result of analysis, in order to develop high performance footwear for the elderly, it is necessary to develop lasts and soles reflecting the elderly's gait patterns.

The Effect of Increased Running Speed on the Magnitude of Impact Shock Attenuation during Ground Contact (착지 시 달리기 속도 증가가 충격 쇼크 흡수에 미치는 영향)

  • Ryu, Jiseon
    • Korean Journal of Applied Biomechanics
    • /
    • v.30 no.3
    • /
    • pp.197-204
    • /
    • 2020
  • Objective: The purpose of this study was to investigate the effect of increased running speed on the magnitude of impact shock attenuation in high frequency (9~20 Hz) at support phase on the treadmill running. Method: Twenty-four healthy male heel-toe runners participated in this study. Average age, height, mass, and preference running speed were 23.43±3.78 years, 176.44±3.38 cm, 71.05±9.04 kg, and 3.0±0.5 m/s, respectively. Three triaxial accelerometer (Noraxon, USA) were mounted to the tuberosity of tibia, PSIS (postero-superior iliac spine), and forehead to collect acceleration signals, respectively. Accelerations were collected for 20 strides at 1,000 Hz during treadmill (Bertec, USA) running at speed of 2.5, 3.0, 3.5, and 4.0 m/s. Power Spectrum Density (PSD) of three acceleration signals was calculated to use in transfer function describing the gain and attenuation of impact shock between the tibia and PSIS, and forehead. One-way ANOVA were performed to compare magnitude of shock attenuation between and within running speeds. The alpha level for all statistical tests was .05. Results: No significant differences resulted for magnitude of the vertical and resultant impact shock attenuation between the tibia and PSIS, and forehead between running speeds. However, significant differences within running speed were found in magnitude of the vertical shock attenuation between tibia and PSIS, tibia and forehead at speed of 2.5, 3.0 m/s, respectively. Conclusion: In conclusion, it might be conjectured that muscles covering the knee and ankle joints and shoe's heel pad need to strengthen to keep the lower extremities from injuries by impact shock at relatively fast running speed that faster than preferred running speed.

Coupled Effect of Soil Nail/Slope Systems (쏘일네일-사면의 상호작용 효과)

  • Jeong Sang Seom;Lee Jin Hyung;Lee Sun Keun
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.2
    • /
    • pp.127-135
    • /
    • 2005
  • In this paper, a numerical comparison of predictions by limit equilibrium analysis and finite difference analysis is presented for slope/soil-nail system. Special attention is given to the coupled analysis based on the explicit-finite-difference code, FLAC 2D. To this end, an internal routine (FISH) was developed to calculate a factor of safety for a soil nail slope according to shear strength reduction method. The case of coupled analyses was performed for soil nails in slope in which the soil nails response and slope stability are considered simultaneously. In this study, by using these methods, the failure surfaces and factors of safety were compared and analyzed in several cases, such as toe, middle and top of the slope, respectively. Furthermore, the coupled method based on shear strength reduction method was verified by the comparison with other analysis results.

Combustion Characteristics of Ionized Fuels for Battery System Safety (배터리 시스템 안전을 위한 이온화 연료의 연소 특성)

  • Ko, Hyeok Ju;Lee, Eui Ju
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.1
    • /
    • pp.22-27
    • /
    • 2018
  • Many electronic devices are powered by various rechargeable batteries such as lithium-ion recently, and occasionally the batteries undergo thermal runaway and cause fire, explosion, and other hazards. If a battery fire should occur in an electronic device of vehicle and aircraft cabin, it is important to quickly extinguish the fire and cool the batteries to minimize safety risks. Attempts to minimize these risks have been carried out by many researchers but the results have been still unsatisfied. Because most rechargeable batteries are operated on the ion state during charge and discharge of electricity and the combustion of ion state has big difference with normal combustion. Here we focused on the effect of ions including an electron during combustion process. The effects of an ionized fuel on the flame stability and the combustion products were experimentally investigated in the propane jet diffusion flames. The burner used in this experiment consisted of 7.5 mm diameter tube for fuel and the propane was ionized with th ionizer (SUNJE, SPN-11). The results show that toe overall flame stability and shape such as flame length has no significant difference even in the higher ion concentration. However the fuel ionization affects to the pollutant emissions such as NOx and soot. NOx and CO emissions measured in post flame region decreased by fuel ionization, especially high fuel velocity, i.e. high ion density. TGA analysis and morphology of soot by TEM indicates that the fuel ionization makes soot to be matured.

Evaluation of Analysis Technique for Piles Driven by Vibration through Parametric Study (매개변수연구를 통한 진동타입말뚝 해석기법 평가)

  • Lee, Seung-Hyun;Lee, Su-Hyung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.3
    • /
    • pp.1749-1755
    • /
    • 2014
  • Technique for analyzing a pile installed by vibrohammer was developed and parametric studies were executed in order to evaluate reliability of the developed technique. Comparing the accelerations obtained from parametric studies of varying eccentric moment and frequency, it can be seen that magnitude of maximum acceleration was proportional to the eccentric moment and square of frequency. It can also be seen that amplitude of displacement was roughly proportional to the eccentric moment but has nothing to do with the frequency. It can be said that all of the analysis results reflect characteristics of behavior of a pile in case of free vibration. Comparing the dynamic load transfer curves, maximum dynamic unit toe resistance was constant regardless of the eccentric moment and the frequency and it can be seen that dynamic unit skin friction was affected by the eccentric moment not by frequency. Comparing all of the analysis results, it can be said that the developed technique is reliable.

The study of effect lumbar flexibility by massage (마사지가 요부 유연성에 미치는 효과 연구(요통환자를 중심으로))

  • Um, Ki-Mae;Yang, Yoon-Kwon;Sung, Ki-Suk
    • Journal of Korean Physical Therapy Science
    • /
    • v.5 no.3
    • /
    • pp.633-642
    • /
    • 1998
  • This study researched 30 subjects. Among them, 15 students, who were experimental group, had lumbago. They received massages during 12weeks(4 times/ week). The effects of massage is fellowing: 1. It represented the discrepancy between the comparison group and the experimental group by toe touching, there was no differences in the comparison group(p<0.05). 2. It represented the discrepancy between the comparison group and the experimental group by trunk and neck, there was no difference in the experimental group, but there were significant differences in the comparison group(p<0.05). 3. It represented the discrepancy between the comparison group and the experimental group by leg elevation, there was no difference in the experimental group, but there were significant difference in the comparison group(p<0.05). 4. It represented the discrepancy between the comparison group and the experimental group, but there were signifiant differences in the comparison(p<0.05).

  • PDF