• Title/Summary/Keyword: Tn3

Search Result 1,099, Processing Time 0.024 seconds

Optical transmission characteristics of a bistable TN LCD (쌍안정 TN LCD의 광투과 특성)

  • 최길재;김양수;강기형;정태혁;윤태훈;김재창;남기곤;이응상
    • Korean Journal of Optics and Photonics
    • /
    • v.8 no.3
    • /
    • pp.218-222
    • /
    • 1997
  • We fabricated a bistable TN LCD with 180$^{\circ}$ twist angle and confirmed that it has a fast switching response time and a high contrast ratio. We also investigated the effects of the amplitude and width of the reset and selection pulses on a bistable TN LC cell and the conditions of the bistability and the memory time. The range of d/p values showing the bistability is determinded for the pretilt angle according to the rubbing depth.

  • PDF

Quality Control on the BOD, COD, TN, TP of Water Quality Pollutant (수질오염물질 BOD, COD, TN, TP의 정도관리(I))

  • Park, Sun-Ku;Kim, Tae-Seung;Ryu, Jae-Kyun
    • Analytical Science and Technology
    • /
    • v.12 no.4
    • /
    • pp.312-317
    • /
    • 1999
  • Quality control was carried out the three analytes, BOD, COD, TN, TP of high and low concentration for thirteen laboratories. Evaluation values of Quality control was determined from average value which were made by six times test, repeatedly and periodically. This value had not only error ratio of within 5% from prepared sample value but also high precision of standard deviation, 0.44 (BOD, low concentration), 2.15 (BOD, high concentration), 0.12 (COD, low concentration), 1.63 (COD, high concentration), 0.35 (TN, low concentration), 1.99 (TN, high concentration), 0.05 (TP, low concentration), 0.14 (TP, high concentration). Upper (Lower) Warning Limit (ULWL) and Upper (Lower) Acceptance Limit (ULAL) values made from quality control chart. Three (5.30, 9.70, 5.30 mg/L) and five laboratories were over ULAL value in low and high BOD concentration, respectively. Two (41.00, 30.60 mg/L) and four laboratories were over ULAL value in low and high COD concentration, respectively. while, other eleven laboratories appeared reliable data. One laboratory (0.70 mg/L) was over ULAL at low TN concentration, while other eleven laboratories had reliable values. In case of high TN concentration, eleven laboratories were over ULAL value, it should be focuced for improvement of reliability about measurement and analysis of TN. Four (1.14, 0.45, 0.64, 1.49mg/L) and seven laboratories were over ULAL in low and high TP concentration, respectively.

  • PDF

Quantitative Analysis of Thyroid Blood Flow and Static Imaging in the Differential Diagnosis of Thyroid Nodules

  • Song, Li-Ping;Zhang, Wen-Hong;Xiang, Yang;Zhao, Na
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.11
    • /
    • pp.6331-6335
    • /
    • 2013
  • Objective:To evaluate the performance of combined quantitative analysis of thyroid blood flow and static imaging data in the differential diagnosis of thyroid nodules. Method: Thyroid blood flow and static imaging were performed in 165 patients with thyroid nodules. Patients were divided into a benign thyroid nodule group (BTN, n=135) and a malignant thyroid nodule group (MTN, n=30) based on the results of post-surgical pathologic examination. Carotid artery thyroid transit times (CTTT), perfusion ratio of thyroid nodule blood/thyroid blood (TNB/TB), and perfusion ratio of thyroid nodule blood/carotid artery blood (TNB/CAB) were measured using thyroid blood flow imaging. The ratios between thyroid nodule and ipsilateral submandibular gland (TN/SG) and thyroid nodule and normal thyroid tissue (TN/T) were measured from thyroid static imaging. The differences between the BTN and MTN groups were compared. Results: 1) CTTT was markedly lower in the MTN group than the BTN group, the difference being statistically significant. 2) TNB/TB and TNB/CAB were both significantly higher in MTN than BTN groups. 3) TN/T was significantly lower in MTN group than BTN group. 4) TN/SG was lower in MTN group than BTN group, but the difference was not statistically significant. 5) Using the combination of CTTT and TN/T, the sensitivity, specificity and accuracy were 93.1%, 95.3% and 94.9% respectively for the diagnosis of MTN. Using the combination of CTTT, TNB/TB and TN/T, the sensitivity, specificity and accuracy changed to 89.7%, 100%, and 98.1% respectively. 6) Correlation analysis demonstrated a significant correlation between TN/T and TNB/TB (r=-0.384, P=0.036) and TNB/CAB (r=-0.466, P=0.009) in the MTN group. Conclusion: The combination of quantitative markers from thyroid blood flow and thyroid static imaging had high specificity and accuracy in differential diagnosis of benign and malignant thyroid nodules, thus providing an important imaging diagnostic approach.

The Efficacy of Microvascular Decompression for Trigeminal Neuralgia (삼차신경통에 대한 미세혈관감압술의 효과)

  • Kim, Sung-Hoon;Choi, Chang-Hwa
    • Journal of Korean Neurosurgical Society
    • /
    • v.37 no.5
    • /
    • pp.357-363
    • /
    • 2005
  • Objective: The microvascular decompression(MVD) for trigeminal neuralgia(TN) is known as an effective surgical technique. But the failed MVD cases have been reported in long term follow-up studies. This study is to evaluate the efficacy of MVD through our operative techniques, offending vessels in operative field, failed cases with the review of the literatures. Methods: We analyzed total 63 cases of TN which underwent MVD from 1955 to 2003 according to characters of pain, operative findings, operative results related to causative vessel compression and operative method, progonotic factor. Statistical analysis was performed using paired t-test with SPSS Ver 11.0. Results: In TN, the most common offending vessel was superior cerebellar artery(45.0%). In compression group of nerve root by offending vessel, the cure rate was 91.7%. However, the cure rate of the contact group was 64.7% and the cure rate of the negative group was 37.5%. There was no statistical significance between the degree of compression by vessel and the operative result(p=0.076). In 51 cases with MVD only, the cure rate was 84.3% and in 3 cases with PSR only, 42.8% and in 2 cases with PSR(partial sensory rhizotomy) with MVD, 50.0%. TN recurred in 7 cases within the follow-up period and reoperations(PSR) were added in 2 cases of them. Conclusion: This study shows that MVD provided a high rate of success with a minor risk of complications, which has been regarded as the most safe and effective procedure for trigeminal neuralgia. Additional MVD in recurred TN by severe adhesion of teflon showed poor outcome. But, revisional operation(PSR) in recurred TN showed relatively good outcome. PSR should be considered for treatment of recurrent TN after MVD.

Evaluation of Korean Water Quality Standards in Winter by Characteristics and Statistical Analyses of the Effluent Water Quality at the Sewage Treatment Plants in Korea (우리나라 공공하수처리시설의 방류수 수질현황 분석을 통한 겨울철 방류수수질기준의 적정성 평가)

  • Um, Chul Yong;Chu, Kyoung Hoon;Yun, Zu Whan;Choi, Ik Hoon;Park, Jae Young;Lee, Han Saem;Ko, Kwang Baik
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.4
    • /
    • pp.523-532
    • /
    • 2011
  • In this study, from 2004 to 2008 influents and discharging effluents from 241 municipal public sewage treatment plants were surveyed. Statistics including average, Coefficient of Variation (CV) and Coefficient of Reliability (COR) for each season, time series analysis for removal efficiency and water quality of effluents, and a comparison of the effluent standards in Korea and other countries were presented. The average concentrations of TN and TP in influents. during winter season were 32.6 and 3.78 mg/L and during other season were 30.8 and 3.61 mg/L in 2008, respectively. The average TN concentration on the basis of the maximum monthly concentrations in the effluents during winter season ranged from 14.2~17.4 mg/L and during other season ranged from 12.2~14.8 mg/L. The TP concentration in the effluents depending on the each season was no big difference. TN removal efficiency decreased from Jan. to Feb. and TP removal efficiency decreased in Jan., Jun and July. Maximum COR during winter season were 0.61 but the COR for TN and TP during other season ranged from 0.96~1.48 and 1.09~1.81, respectively, due to big difference in the standard for TN and TP in effluents depending on the season. TN and TP standards for effluent of sewage treatment during winter season in Korea was much higher than those in other countries. Therefore the lower effluent standards during winter season is essential for the water quality improvement.

Comparison of Seasonal Nitrogen Removal by Free-Water Surface Wetlands Planted with Iris pseudacorus L. (노랑꽃창포 자유수면습지의 계절에 따른 질소제거 비교)

  • Yang, Hongmo
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.14 no.1
    • /
    • pp.121-132
    • /
    • 2011
  • Removal rates of $NO_3$-N and TN in the free-water surface wetland system during winter; December, January, February and March, spring and fall; April, May, October and November, and summer; Jun, July, August and September were investigated. The system was established on floodplain in the downstream reach of the Gwangju Stream in 2008. It measures 50 meters in length and 5.5 meters in width. Iris pseudacorus L. grown in pots for about two years were planted in the system. The water stream was funneled in by gravity and its effluent was discharged back in. Volumes and water quality of inflow and outflow were analyzed from December 2008 to November 2010. The inflow was averaged approximately 350 $m^3/day$ and hydraulic residence time was about 3 hours. Average influent and effluent $NO_3$-N concentration was 3.75 and 3.35 mg/L, respectively and $NO_3$-N retention was amounted to 10.6%. Influent and effluent TN concentration were averaged 4.93 and 4.30 mg/L, respectively and TN abatement reached to 12.9%. One-way ANOVA statistics claimed that the average removal rates of $NO_3$-N and TN during winter, spring and fall, and summer were not always the same (p<0.001). The t-Tests of three pairs among $NO_3$-N removal rates of winter, spring and fall, and summer illustrated that the removal rates of winter ($5.04{\pm}1.94$), spring and fall ($10.53{\pm}2.24$), and summer ($18.61{\pm}2.26$) were significantly different each others (p<0.001). Among TN removal rates, the three pairs of t-Tests of three seasons showed that the removal rates of winter ($5.21{\pm}2.51$), spring and fall ($11.71{\pm}3.12$), and summer ($21.53{\pm}4.86$) were significantly different from each others (p<0.001).

Optimization of Human Thrombopoietin Production in Insert Cells Using Baculovirus Expression System (베큘로 바이러스 발현 시스템에 의한 곤충세포에서의 인간 트롬보포이에틴 생산 최적화)

  • 고여욱;손미영;박상규;안혜경;박승국;박명환;양재명
    • KSBB Journal
    • /
    • v.13 no.2
    • /
    • pp.181-186
    • /
    • 1998
  • In order to obtain high-level production of recombinant human thrombopoietin (rhTPO) in insect cell line, HTI-TN-5B1-4 (TN5), conditions for optimal rhTPO expression such as multiplicity of infection (MOI), the cell density at infection, harvesting time and type of culture method as well as growth media were determined. When TN5 cells were cultured as anchorage-dependent state in 60-mm dish, cell density $2\times^6$ cells,MOI of 10 and Garvesting the culture media at 72 hr post-infection wrere the cinditions for highest rh TPO production. High production of rhTPO was also achieved by using EXPRESS FIVE serum free media rather than SF900II serum free media-1. Anchorage-dependent TN5 cells were adapted as a suspension culture when they were grown in the presence of heparin. TN5 cells were successfully cultured at 0.2 L scale in suspension culture without having aggregation. When TN5 cells were cultured as suspension state, cell density of $0.6\times10^6$ cells/mL, MOI of 1 and harvesting the culture media at 72 hr post-infection, gave the highest yield of rhTPO.

  • PDF

Comparison of Nitrogen Removal in a Horizontal Subsurface-Flow Wetland Purifying Stream Water with and without Litter Layer on its Surface (하천수를 정화하는 수평흐름 여과습지의 표면 잔재물층 유무에 의한 질소제거 비교)

  • Yang, Hongmo
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.12 no.1
    • /
    • pp.111-122
    • /
    • 2009
  • Abatements of TN and ${NO_3}^-$-N in a horizontal subsurface-flow wetland with litter layer on its surface were compared with those without one. The wetland was constructed in 2001 on floodplain of the Gwangju Stream which flows through Gwangju City in Korea. Its dimensions were 29m in length, 9m in width and 0.65m in depth. A bottom layer of 45cm was filled with crushed granites (15~40mm in diameter) and a middle layer of 10cm had pea pebbles. An upper layer of 5cm contained coarse sands. Reeds (Phragmites australis) growing in natural wetlands were transplanted on its surface. Water of the stream was channelled into the wetland by gravity flow and its effluent was discharged back into the stream. Average Litter layer of 12.2cm was formed on its surface in 2007. The layer and above-ground parts of reeds were eliminated in April 2008. Volumes and water quality of influent and effluent of the wetland were analyzed from May to November in 2007 and 2008, respectively. Inflow into the wetland both in 2007 and 2008 averaged approximately 40$m^3$/day and hydraulic residence time both in 2007 and 2008 was about 1.5days. Influent TN concentration in 2007 and 2008 averaged 3.96 and 3.89mg/L, respectively and average influent ${NO_3}^-$-N concentration in 2007 and 2008 was 2.11 and 2.05mg/L, respectively. With a 0.05 significance level, influent concentrations of TN and ${NO_3}^-$-N, temperatures and pH of effluent, and heights and stem numbers of reeds showed no difference between the wetland with litter layer and without one. TN retention in the wetland with litter layer and without one averaged 64,76 and 54.69%, respectively and ${NO_3}^-$-N removal averaged 60.83 and 50.61%, respectively. Both TN and ${NO_3}^-$-N abatement rates in the wetland with litter layer were significantly high (TN abatement: p<0,001, ${NO_3}^-$-N abatement: p=0.001) when compared with those without one. The subsurface-flow wetland having litter layer on its surface was more efficient for TN and ${NO_3}^-$-N removal.

Evaluation of Percolated Water Quality of Paddy Fields Using Nonparametric Test (비모수검정을 이용한 논침투수 수질의 평가)

  • Oh, Seung-Young;Kim, Jin-Soo;Oh, Kwang-Young
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.47 no.2
    • /
    • pp.99-110
    • /
    • 2005
  • Characteristics of concentrations of total nitrogen (TN), total phosphorus (TP), and chemical oxygen demand (COD) pollutant in percolated water at four paddy field sites (Soro, Odong, Munui, and Boeun) were investigated by a nonparametric test. Percolation rate measurement and percolated water sampling were taken during irrigation periods at $5{\sim}10$ day intervals. The normality of percolation rate and pollutant concentrations were examined using histogram, boxplot, and the Kolmogorov-Smirnov (K-S) test. Pollutant concentrations in percolated water showed positively skewed distribution. The median concentrations of pollutant were 1.91 mg/L for TN, 0.021 mg/L for TP, and 6.6 mg/L for COD, which were lower than its arithmetic mean concentrations by $35\%$ for TN, $36\%$ for TP, and $13\%$ for COD. The median concentrations of TN and TP differed significantly among sample sites according to the Kruskal-Wallis test. However, median concentrations were not significantly different among month except for TN and TP of Soro and COD of Odong. The percolation load of pollutants during irrigation periods in the study area were estimated at $3.12{\sim}7.75\;kg/ha$ for TN, $0.033{\sim}0.155\;kg/ha$ for TP, and 10.7 kg/ha for COD, which were much lower than respective values reported in Japan.

GRAZING MANAGEMENT STUDIES WITH THAI GOATS II. REPRODUCTIVE PERFORMANCES OF DIFFERENT GENOTYPES OF DOES GRAZING IMPROVED PASTURE WITH OR WITHOUT CONCENTRATE SUPPLEMENTATION

  • Kochapakdee, S.;Pralomkarn, W.;Saithanoo, S.;Lawpetchara, A.;Norton, B.W.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.7 no.4
    • /
    • pp.563-570
    • /
    • 1994
  • Fifty-one Thai Native (TN) and Anglo-Nubian (AN) $\times$ TN does were studied. The purpose of the study was to investigate the reproductive performances of different goat genotypes grazing improved pasture with or without supplementary feeding. The feeding regimes were: 1. no concentrate supplement (T1), 2. supplemented for 15 days before mating and 45 days during mating period (T2), 3. supplemented from 15 days before mating to 42 days after kidding (T3) and 4. supplemented for 30 days before kidding, followed by 42 days after kidding. Cross-bred does tended to have higher conception rates, kidding opportunities and higher multiple birth rates than TN does. However, these differences were not statistically significant (p>0.05), and concentrate supplementation under the various regimes did not increase reproductive performance. TN kids had significantly (p<0.01) lower birth weights and lower weights at 3, 6 and 12 weeks of age than those of the cross-bred kids. However, there was no significant difference between the genotypes in growth rate (g/d or $g/kg^{75}/d$) of kids during these periods. Supplementary feeding did not significantly affect either kid birth weight or weight gain in the first 6 weeks after birth and during this period supplementary adequate in both quantity and quality, substantial reproductive performances were achieved from both TN and AN $\times$ TN does without concentrate supplementation.