• Title/Summary/Keyword: Tm3+

Search Result 2,032, Processing Time 0.035 seconds

Evaluating efficiency of application the skin flash for left breast IMRT. (왼쪽 유방암 세기변조방사선 치료시 Skin Flash 적용에 대한 유용성 평가)

  • Lim, Kyoung Dal;Seo, Seok Jin;Lee, Je Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.49-63
    • /
    • 2018
  • Purpose : The purpose of this study is investigating the changes of treatment plan and comparing skin dose with or without the skin flash. To investigate optimal applications of the skin flash, the changes of skin dose of each plans by various thicknesses of skin flash were measured and analyzed also. Methods and Material : Anthropomorphic phantom was scanned by CT for this study. The 2 fields hybrid IMRT and the 6 fields static IMRT were generated from the Eclipse (ver. 13.7.16, Varian, USA) RTP system. Additional plans were generated from each IMRT plans by changing skin flash thickness to 0.5 cm, 1.0 cm, 1.5 cm, 2.0 cm and 2.5 cm. MU and maximum doses were measured also. The treatment equipment was 6MV of VitalBeam (Varian Medical System, USA). Measuring device was a metal oxide semiconductor field-effect transistor(MOSFET). Measuring points of skin doses are upper (1), middle (2) and lower (3) positions from center of the left breast of the phantom. Other points of skin doses, artificially moved to medial and lateral sides by 0.5 cm, were also measured. Results : The reference value of 2F-hIMRT was 206.7 cGy at 1, 186.7 cGy at 2, and 222 cGy at 3, and reference values of 6F-sIMRT were measured at 192 cGy at 1, 213 cGy at 2, and 215 cGy at 3. In comparison with these reference values, the first measurement point in 2F-hIMRT was 261.3 cGy with a skin flash 2.0 cm and 2.5 cm, and the highest dose difference was 26.1 %diff. and 5.6 %diff, respectively. The third measurement point was 245.3 cGy and 10.5 %diff at the skin flash 2.5 cm. In the 6F-sIMRT, the highest dose difference was observed at 216.3 cGy and 12.7 %diff. when applying the skin flash 2.0 cm for the first measurement point and the dose difference was the largest at the application point of 2.0 cm, not the skin flash 2.5 cm for each measurement point. In cases of medial 0.5 cm shift points of 2F-hIMRT and 6F-sIMRT without skin flash, the measured value was -75.2 %diff. and -70.1 %diff. at 2F, At -14.8, -12.5, and -21.0 %diff. at the 1st, 2nd and 3rd measurement points, respectively. Generally, both treatment plans showed an increase in total MU, maximum dose and %diff as skin flash thickness increased, except for some results. The difference of skin dose using 0.5 cm thickness of skin flash was lowest lesser than 20 % in every conditions. Conclusion : Minimizing the thickness of skin flash by 0.5 cm is considered most ideal because it makes it possible to keep down MUs and lowering maximum doses. In addition, It was found that MUs, maximum doses and differences of skin doses did not increase infinitely as skin flash thickness increase by. If the error margin caused by PTV or other factors is lesser than 1.0 cm, It is considered that there will be many advantages in with the skin flash technique comparing without it.

  • PDF

A New Approach with Combined Stereotactic Trans-multiarc Beams for Radiosurgery Based on the Linear Accelerator : Photon Knife (입체적횡다증회전조사를 병합한 방사선수술의 새로운 접근 : 포톤나이프)

  • Choi, Tae-Jin;Kim, Jin-Hee;Kim, Ok-Bae
    • Radiation Oncology Journal
    • /
    • v.14 no.2
    • /
    • pp.149-158
    • /
    • 1996
  • Purpose : To get an accute steepness of dose gradients at outside the target volume in intracranial lesion and a less limitation of beam selection avoiding the high dose at normal brain tissue, this Photon Knife Radiosurgery System was developed in order to provide the three-dimensional dose distribution through the reconstruction of CT scan and the combined stereotactic trans-multiarc beam mode based on linear accelerator photon beam. Materials and methods : This stereotactic radiosurgery, Photon Knife based on linear accelerator photon beam was provided the non-coplanar multiarc and trans-multiarc irradiations. The stereotactic trans-multiarc beam mode can be obtained from the patient position in decubitus. This study has provided the 3-dimensional isodose curve and anatomical structures with the surface rendering technique. The dose distribution from the combined two trans-multiarcs (2M 2TM) was compared to that of four non-coplanar multiarcs (4M) with same collimator size of 25 mm in a diameter and total gantry movements. Results : In this study, it shows that the dose distributions of stereotactic beam mode are significantly depended on the selected couch and gantry angle in same collimator size. Practical dose distribution of combined stereotactic trans-multiarc beam has shown a more small rim thickness than that of the non-coplanar multiarc beam mode in axial, sagittal and coronal plane in our study. 3-Dimensional dose line displayed with surface rendering of irregular target shape is helpful to determine the target dose and to predict the prognosis in follow-up radiosurgery. Conclusions : 3-Dimensional dose line displayed with surface rendering of irregular target shape is essential in stereotactic radiosurgery. This combined stereotactic trans-multiarc beam has shown a less limitation of the selection couch and gantry beam angles for the target surrounding critical organs. It has shown that the dose distribution of combined trans-multiarc beam greatly depended on the couch and gantry angles. In our experiments, the absorbed dose has been decreased to $27%$ / mm in maximum at the interval of $50\%$ to $80\%$ of isodose line.

  • PDF

Self-Perceived Oral Health Status according to Regulation of Blood Glucose in the Type 2 Diabetic Patients (제2형 당뇨병 환자에서 혈당조절에 따른 구강건강인식도)

  • Kang, Hui-Eun;Kim, Sun-Ju;Choi, Jun-Seon
    • Journal of dental hygiene science
    • /
    • v.12 no.5
    • /
    • pp.493-502
    • /
    • 2012
  • The aim of this study was to investigate the oral health problems among type 2 diabetes patients and suggest basic data for the promotion of their body and oral health by emphasizing the correlation between hemoglobin A1c and subjective oral health status. For 174 patients with type 2 diabetes and who were older than 40 years old, the questionnaire and measurement of hemoglobin A1c were conducted from January 9, 2012 to March 9, 2012. The results of the study were as follows. 1. They tended to be most aware of the following; 'inflammation on the oral mucosa' and 'pain on the oral mucosa' among the symptoms of oral mucosa, 'gum bleeding when brushing teeth' among the symptoms of periodontal disease, and 'feels dry in general' among the symptoms of xerostomia. 2. The patients with longer duration of diabetes showed greater recognition with regards to the symptoms of oral mucosa disease, periodontal disease, and xerostomia (p<0.05). 3. The group with regular meal showed lower level of hemoglobin A1c (p<0.001). 4. The level of hemoglobin A1c was higher in the group that recognized 'burning sensation', 'gum bleeding', 'gum recession' and 'bad breath' (p<0.05) as well as in the group that responded 'get up at night to drink' among the symptoms of xerostomia (p<0.05). Especially the symptoms of periodontal disease were revealed to be a factor that showed the 3rd strongest correlation with hemoglobin A1c.

The Study about Application of LEAP Collimator at Brain Diamox Perfusion Tomography Applied Flash 3D Reconstruction: One Day Subtraction Method (Flash 3D 재구성을 적용한 뇌 혈류 부하 단층 촬영 시 LEAP 검출기의 적용에 관한 연구: One Day Subtraction Method)

  • Choi, Jong-Sook;Jung, Woo-Young;Ryu, Jae-Kwang
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.102-109
    • /
    • 2009
  • Purpose: Flash 3D (pixon(R) method; 3D OSEM) was developed as a software program to shorten exam time and improve image quality through reconstruction, it is an image processing method that usefully be applied to nuclear medicine tomography. If perfoming brain diamox perfusion scan by reconstructing subtracted images by Flash 3D with shortened image acquisition time, there was a problem that SNR of subtracted image is lower than basal image. To increase SNR of subtracted image, we use LEAP collimators, and we emphasized on sensitivity of vessel dilatation than resolution of brain vessel. In this study, our purpose is to confirm possibility of application of LEAP collimators at brain diamox perfusion tomography, identify proper reconstruction factors by using Flash 3D. Materials and methods: (1) The evaluation of phantom: We used Hoffman 3D Brain Phantom with $^{99m}Tc$. We obtained images by LEAP and LEHR collimators (diamox image) and after 6 hours (the half life of $^{99m}Tc$: 6 hours), we use obtained second image (basal image) by same method. Also, we acquired SNR and ratio of white matters/gray matters of each basal image and subtracted image. (2) The evaluation of patient's image: We quantitatively analyzed patients who were examined by LEAP collimators then was classified as a normal group and who were examined by LEHR collimators then was classified as a normal group from 2008. 05 to 2009. 01. We evaluate the results from phantom by substituting factors. We used one-day protocol and injected $^{99m}Tc$-ECD 925 MBq at both basal image acquisition and diamox image acquisition. Results: (1) The evaluation of phantom: After measuring counts from each detector, at basal image 41~46 kcount, stress image 79~90 kcount, subtraction image 40~47 kcount were detected. LEAP was about 102~113 kcount at basal image, 188~210 kcount at stress image and 94~103 at subtraction image kcount were detected. The SNR of LEHR subtraction image was decreased than LEHR basal image about 37%, the SNR of LEAP subtraction image was decreased than LEAP basal image about 17%. The ratio of gray matter versus white matter is 2.2:1 at LEHR basal image and 1.9:1 at subtraction, and at LEAP basal image was 2.4:1 and subtraction image was 2:1. (2) The evaluation of patient's image: the counts acquired by LEHR collimators are about 40~60 kcounts at basal image, and 80~100 kcount at stress image. It was proper to set FWHM as 7 mm at basal and stress image and 11mm at subtraction image. LEAP was about 80~100 kcount at basal image and 180~200 kcount at stress image. LEAP images could reduce blurring by setting FWHM as 5 mm at basal and stress images and 7 mm at subtraction image. At basal and stress image, LEHR image was superior than LEAP image. But in case of subtraction image like a phantom experiment, it showed rough image because SNR of LEHR image was decreased. On the other hand, in case of subtraction LEAP image was better than LEHR image in SNR and sensitivity. In all LEHR and LEAP collimator images, proper subset and iteration frequency was 8 times. Conclusions: We could archive more clear and high SNR subtraction image by using proper filter with LEAP collimator. In case of applying one day protocol and reconstructing by Flash 3D, we could consider application of LEAP collimator to acquire better subtraction image.

  • PDF

A Study of volumetric modulated arc therapy for stereotactic body radiation therapy in case of multi-target liver cancer using flattening filter free beam (다중표적 간암의 정위적체부방사선치료에서 무편평화여과기선질 용적변조회전치료의 유용성 평가)

  • Yeom, Misuk;Yoon, Inha;Hong, Donggi;Back, Geummun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.1
    • /
    • pp.31-43
    • /
    • 2015
  • Purpose : Stereotactic body radiation therapy (SBRT) has proved its efficacy in several patient populations with primary and metastatic limited tumors. Because SBRT prescription is high dose level than Conventional radiation therapy. SBRT plan is necessary for effective Organ at risk (OAR) protection and sufficient Planning target volume (PTV) dose coverage. In particular, multi-target cases may result excessive doses to OAR and hot spot due to dose overlap. This study evaluate usefulness of Volumetric modulated arc therapy (VMAT) in dosimetric and technical considerations using Flattening filter free (FFF) beam. Materials and Methods : The treatment plans for five patients, being treated on TrueBeam STx(Varian$^{TM}$, USA) with VMAT using 10MV FFF beam and Standard conformal radiotherapy (CRT) using 15MV Flattening filter (FF) beam. PTV, liver, duodenum, bowel, spinal cord, esophagus, stomach dose were evaluated using the dose volume histogram(DVH). Conformity index(CI), homogeneity index(HI), Paddick's index(PCI) for the PTV was assessed. Total Monitor unit (MU) and beam on time was assessed. Results : Average value of CI, HI and PCI for PTV was $1.381{\pm}0.028$, $1.096{\pm}0.016$, $0.944{\pm}0.473$ in VMAT and $1.381{\pm}0.042$, $1.136{\pm}0.042$, $1.534{\pm}0.465$ in CRT respectively. OAR dose in CRT plans evaluated 1.8 times higher than VMAT. Total MU in VMAT evaluated 1.3 times increase than CRT. Average beam on time was 6.8 minute in VMAT and 21.3 minute in CRT. Conclusion : VMAT for SBRT in multi-target liver cancer using FFF beam is effective treatment techniqe in dosimetric and technical considerations. VMAT decrease intra-fraction error due to treatment time shortening using high dose rate of FFF beam.

  • PDF

Early Clinical Outcome and Doppley Echocardiographic Data after Cardiac Valve Replacement with the ATS prosthesis (ATS 인공 판막의 조기 임상성적 및 도플러 심에코 검사 소견)

  • 박계현;박승우
    • Journal of Chest Surgery
    • /
    • v.30 no.7
    • /
    • pp.663-669
    • /
    • 1997
  • This is a report on the clinical outcome and hemodynamic profile of the ATSwcardiac valve prosthesis, which is a recently introduced pyrolytic carbon bileaflet prosthesis. We retrospectively reviewed the early outcome of 100 consecutive patients who underwent isolated cardiac valve replacement with the ATS(w prosthesis from October 1994 through June 1996 at our hospital. All patients were evaluated with Doppler echocardiography before discharge from the hospital. The mean age of the patients was 48.6 years(range: 2 to 74). A tota of 124 prosthesis were implanted; 71 mitral, 46 aortic, and 7 tricuspid. The two most frequently used sizes were 27 mm(40.8%) and 29 mm(35.2%) in the mitral position, and 23 mm(30.4%) and 21 mm(28.3%) in the aortic position. There was no early or late death. The total follow-up period was 950 patient-months with 99% follow-up rate. Serious late morbidity occurred in three patients; reoperation in two patients for late rupture of Sinus of Valsava in one and for endocarditis with prosthetic dehiscence in the other, and intracranial hemorrhage due to hypertension in one patient. There has been no thromboembolic complication or structural valval deterioration. In the mitral position, the average values of peak and mean transprosthetic pressure gradients and valve area calculated from pressure half time were 6.9$\pm$2.8 mmHg, 2.6$\pm$ 1.5 mmHg, and 2.7 $\pm$0.8 cm2 respectively. In the aortic position, the peak and mean pressure gradients'were 26.4 $\pm$ 15.9 mmHg and 14.2 $\pm$ 7.9 mmHg. For the mitra prostheses larger than 25-mm size, there was no significant difference among prosthetic sizes in terms of transprosthetic gradients, whereas there was a significant negative correlation between the prosthesis size and the transprosthetic gradients for the aortic valves. The peak and mean Pressere pradients were 52.2 $\pm$ 17.6 tmHg and 26.9$\pm$ 7.4 mmHg across the 19-mm aortic Prostheses, and 27.1 $\pm$ 11.9 mmHg and 13.3$\pm$6.6 mmHg across the 21-mm size. Above results can lead to the conclusion that the early clinical outcome of the ATS valve prosthesis is quite satisfactory, And the hemodynamic characteristics are comparable, if not better, with other bileaflet prostheses.

  • PDF

LONG-TERM EVALUATING OF THE REMINERALIZATION OF INTERPROXIMAL CARIES ADJACENT TO GLASS IONOMER RESTORATIONS: A MICRO-CT STUDY (미세 전산화 단층 촬영을 이용한 글라스 아이오노머 수복물의 인접면우식 재광화 효과에 관한 장기간 연구)

  • Lee, Hyeok-Sang;Kim, Young-Jae;Kim, Jung-Wook;Jang, Ki-Taeg
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.3
    • /
    • pp.498-503
    • /
    • 2006
  • This in vitro study compared the remineralization of incipient interproximal caries in the presence of three glass ionomer cements (highly-filled glass ionomer cement, compomer, resin-modified glass ionomer cement) and a resin composite(control). The long-term changes in remineralization caused by each material were evaluated by microtomography. Proximal restoration was simulated by placing tooth specimens and the various glass ionomer cements in closed containers with artificial saliva at $37^{\circ}C$ and pH 7.0 for 30 days with constant circulation Tomographic images were obtained with a micro CT scanner at 90, 180, and 270 days, and density-measuring software was used to calculate the micro-density of artificial caries lesions in the specimens. The mean density changes were compared between groups in order to evaluate the effects of remineralization. All data were analyzed using one-way ANOVA and the post-HOC Tukey multiple comparison test at p<0.05. While the density of artificial caries lesions increased for all treatments, the increases for the three glass ionomer groups were significantly higher than that for the resin group in each three month period. As time went on, the amount of density increase of the glass ionomer groups decreased, and significant differences were found between the remineralization effects of the glass ionomer groups.

  • PDF

Development of Yoghurt with Sanmeoru (Vitis amurensis Ruprecht) Wine as an Additive (산머루 와인을 첨가한 요구르트의 품질 특성)

  • Kim, Jae-Kyeoung;Lee, Jai-Sung;Jeong, Yu-Tae;Bae, In-Hyu
    • Journal of Dairy Science and Biotechnology
    • /
    • v.30 no.1
    • /
    • pp.23-30
    • /
    • 2012
  • This study was carried out to investigate the quality characteristics of yoghurt with varying contents of Sanmeoru (Vitis amurensis Ruprecht) wine (SW). Yoghurts were fermented with 2 kinds of lactic acid bacteria (Streptococcus thermophilus and Lactobacillus bulgaricus; Yo-$MIX^{TM5}505$, Danisco, Denmark). The changes in quality characteristics were investigated during fermentation and storage, and anthocyanin composition was analyzed after fermentation. The pH decreased in all treatments, while titratable acidity and viscosity gradually increased during fermentation. The viscosity of the yoghurt with 5.0% cultured SW added was higher than in other groups. The viable counts of lactic acid bacteria gradually increased during fermentation. The sample of the 5.0% cultured SW-yoghurt was higher than that of the other groups. The pH slowly decreased during the storage period; this was lower in the control yoghurt than in the yoghurts containing SW, and the changes of titratable acidity in the samples containing 5.0% and 30.0% cultured SW were lower than that in the yoghurt containing 1.0% cultured SW and in the control. The change in viscosity and number of viable cells during storage was higher in the yoghurts containing SW than in the control group. The levels of anthocyanin increased with the SW content in the yoghurt. Sensory scores for taste of the yoghurt with 1.0% added SW was significantly higher than for the other groups. Yoghurt with added SW kept at $4^{\circ}C$ for 12 days retained its quality characteristics fairly well.

  • PDF

Usefulness of volumetric BMD measurement by using low dose CT image acquired on L-spine Bone SPECT/CT (L-spine Bone SPECT/CT에서 획득된 저선량 CT 영상을 이용한 용적 골밀도 결과의 유용성)

  • Hyunsoo Ko;Soonki Park;Eunhye Kim;Jongsook Choi;Wooyoung Jung;Dongyun Lee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.27 no.2
    • /
    • pp.99-109
    • /
    • 2023
  • Purpose: CT scan makes up for the weak point of the nuclear medicine image having a low resolution and also were used for attenuation correction on image reconstruction. Recently, many studies try to make use of CT images additionally, one of them is to measure the bone mineral density(BMD) using Quantitative CT(QCT) software. BMD exams are performed to scan lumbar and femur with DXA(Dual-Energy X-Ray Absorptiometry) in order to diagnose bone disease such as osteopenia, osteoporosis. The purpose of this study is to identify the usefulness of QCT_BMD analyzed with low dose CT images on L-spine Bone SPECT/CT comparing with DXA_BMD. Materials and Methods: Fifty five women over 50 years old (mean 66.4 ± 9.1) who took the both examinations(L-spine Bone SPECT/CT with SIEMENS Intevo 16 and DXA scan with GE Lunar prodigy advance) within 90 days from April 2017 to July 2022, BMD, T-score and disease classification were analyzed. Three-dimensional BMD was analyzed with low dose CT images acquired on L-spine Bone SPECT/CT scan on Mindways QCT PROTM software and two-dimensional BMD was analyzed on DXA scan. Basically, Lumbar 1-4 were analyzed and the patients who has lesion or spine implants on L-spine were excluded for this study. Pearson's correlation analysis was performed in BMD and T-score, chi-square test was performed in disease classification between QCT and DXA. Results: On 55 patients, the minimum of QCT_BMD was 18.10, maximum was 166.50, average was 82.71 ± 31.5 mg/cm3. And the minimum of DXA-BMD was 0.540, maximum was 1.302, average was 0.902 ± 0.201 g/cm2, respectively. The result shows a strong statistical correlation between QCT_BMD and DXA_BMD(p<0.001, r=0.76). The minimum of QCT_T-score was -5.7, maximum was -0.1, average was -3.2 ± 1.3 and the minimum of DXA_T-score was -5.0, maximum was 1.7, average was -2.0 ± 1.3, respectively. The result shows a statistical correlation between QCT T-score and DXA T-score (p<0.001, r=0.66). On the disease classification, normal was 5, osteopenia was 25, osteoporosis was 25 in QCT and normal was 10, osteopenia was 25, osteoporosis was 20 in DXA. There was under-estimation of bone decrease relatively on DXA than QCT, but there was no significant differences statistically by chi-square test between QCT and DXA. Conclusion: Through this study, we could identify that the QCT measurement with low dose CT images QCT from L-Spine Bone SPECT/CT was reliable because of a strong statistical correlation between QCT_BMD and DXA_BMD. Bone SPECT/CT scan can provide three-dimensional information also BMD measurement with CT images. In the future, rather than various exams such as CT, BMD, Bone scan are performed, it will be possible to provide multipurpose information via only SPECT/CT scan. In addition, it will be very helpful clinically in the sense that we can provide a diagnosis of potential osteoporosis, especially in middle-aged patients.

The variability of tumor motion and respiration pattern in Stereotactic Body RadioTherapy(SBRT) for Lung cancer patients (RPM SystemTM을 이용한 호흡 관찰의 유용성 평가)

  • Park, hyun jun;Bae, sun myeong;Baek, Geum Mun;Kang, tae young;Seo, Dong Rin
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.1
    • /
    • pp.17-25
    • /
    • 2016
  • Purpose : The purpose of this study is to evaluate the variability of tumor motion and respiration pattern in lung cancer patients undergoing Stereotactic Body RadioTherapy(SBRT) by using On-Board imager (OBI) system and Real-time Position Management (RPM) System. Materials and Methods : This study population consisted of 60 lung cancer patient treated with stereotactic body radiotherapy (48 Gy / 4 fractions). Of these, 30 were treated with gating (group 1) and 30 without gating(group2): typically the patients whose tumors showed three-dimensional respiratory motion > 10 mm were selected for gating. 4-dimensional Computed Tomography (4DCT). Cone Beam CT (CBCT) and Fluoroscopy images were used to measure the tumor motion. RPM system was used to evaluate the variability of respiration pattern on SBRT for group1. Results : The mean difference of tumor motion among 4DCT, CBCT and Fluoroscopy images in the cranio-caudal direction was 2.3 mm in group 1, 2. The maximum difference was 12.5 mm in the group 1 and 8.5 mm in group 2. The number of treatment fractions that patient's respiration pattern was within Upper-Lower threshold on SBRT in group 2 was 31 fractions. A patient who exhibited the most unstable pattern exceeded 108 times in a fraction Conclusion : Although many patients in group 1 and 2 kept the reproducibility of tumor motion within 5 mm during their treatment, some patients exhibited variability of tumor motion in the CBCT and Fluoroscopy images. It was possible to improve the accuracy of dose delivery in SBRT without gating for lung cancer patient by using RPM system.

  • PDF