• Title/Summary/Keyword: Tm3+

Search Result 2,032, Processing Time 0.029 seconds

Ontology describing Process Information for Web Services Discovery (웹 서비스 발견을 위해 프로세스 정보를 기술하는 온톨로지)

  • Yu, Jeong-Youn;Lee, Kyu-Chul
    • The Journal of Society for e-Business Studies
    • /
    • v.12 no.3
    • /
    • pp.151-175
    • /
    • 2007
  • Until now, most semantic web service discovery research has been carried out using either Web Service Modeling Ontology (WSMO) or a profile of OWL-based Web Service ontology (OWL-S). However, such efforts have focused primarily on service name and input/output ontology. Thus, the internal information of a service has not been utilized, and queries regarding internal information such as 'Find book-selling services allowing payment after delivery' are not addressed. This study outlines the development of TM-S (Topic Maps for Service) ontology and TMS-QL (TM-S Query Language), two novel technologies that address the aforementioned issues in semantic web service discovery research. TM-S ontology describes the behavior of services using process information and consists of three sub-ontologies: process signature ontology, process structure ontology and process concept ontology. TMS-QL allows users to describe service discovery requests.

  • PDF

Remote Sensing Application for the Mineralized Zone Using Landsat TM Data (LANSAT TM자료에 의한 광화대조사 응용기법개발)

  • 姜必鍾;智光薰;曺民肇;崔映燮;Choi, Young Sup
    • Korean Journal of Remote Sensing
    • /
    • v.2 no.2
    • /
    • pp.79-94
    • /
    • 1986
  • TM data, which have better resolution in spatial and spectral than MSS data, were used for this study, and several Image Processing Techniques (IPT) were examined for finding the best IPT to fit to lineament extraction and mineralized zone mapping. The Ryeongnam area was selected as test area, because the area is one of major mineralized zones in Korea and its hydrothermal alteration zone is wider and deeper than other areas. The spatial filtering method is most optimum one for limeament extraction: that is, the directional spatial filtering is most efficient to detect N-S, E-W direction lineaments on the image, and the high boost filtering can be applied for mapping all direction lineaments. The ratio method was selected for detecting altered zone. It is possible to make several tens combinations in ratio with 7 bands of TM data, but considering spectral characteristics of each band of TM to the geological meterials and vegetation, the band 4/band 3(A), band 5/band 7(B), and B/A ratio methods were chosen among them. The 5/7 ratio image did not show clearly the altered area due to noise from vegetation cover, so the 4/3 ratio imae was used for trying to decrease the effect of vegetation. As a result the B/A ratio image showed quite nicely the altered zone of the test area. In conclusion, the spatial filtering is the best image processing techniques for lineament mapping, and the B/A ratio image in TM data is useful for the mineralized zone mapping.

Comparison of Shear Bond Strength of Different Restorative Materials to Tricalcium Silicate-Based Pulp Capping Materials (Tricalcium Silicate-Based 치수복조재에 대한 수 종 수복재의 전단결합강도 비교)

  • Jeong, Hwakyong;Lee, Nanyoung;Lee, Sangho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.44 no.2
    • /
    • pp.200-209
    • /
    • 2017
  • The aim of this study was to evaluate the shear bond strength (SBS) of three typical restorative materials - glass ionomer cement (GIC), resin-modified glass ionomer (RMGIC) and composite resin (CR) - to different pulp capping materials, i.e., Theracal $LC^{TM}$ (TLC), $Biodentine^{TM}$ (BD), and $ProRoot^{TM}$ white MTA (WMTA). 90 acrylic blocks with a center hole were prepared. The holes were completely filled with three pulp capping materials (TLC, BD, and WMTA), with 30 specimens per capping material. The samples were then randomly divided into 3 subgroups of 10 specimens each and were overlaid with GIC, RMGIC, or CR. A total 9 specimen groups were prepared. The SBS was assessed using a universal testing machine. Kruskal-Wallis test and Mann-Whitney's test were performed to compare the SBS among the subgroups (p < 0.05). After the SBS test, the fractured surfaces were examined under a stereomicroscope at a magnification of $25{\times}$. The highest and lowest SBS values were recorded for TLC-CR and TLC-GIC, respectively. With regard to the SBS to the three pulp capping materials, CR was found to be superior to RMGIC and GIC. BD showed a higher SBS compared to TLC and WMTA when used with GIC.

Photoluminescence properties of $Gd_{1-x}Ln_xCa_3(GaO)_3(BO_3)_4$ (Ln=Eu, Tb, Tm) under UV excitation

  • Kyung, Hyun-Ai;Jung, Ha-Kyun;Seong, Tae-Yeon
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08b
    • /
    • pp.1565-1568
    • /
    • 2007
  • A borate compound was adopted as new host material for $Eu^{3+}$, $Tb^{3+}$ and $Tm^{3+}$ activators. The phosphor samples, $Gd_{1-x}Eu_xCa_3(GaO)_3(BO_3)_4$, $Gd_{1-x}Tb_xCa_3(GaO)_3(BO3)_4$ and $Gd_{1-x}Tm_xCa_3(GaO)_3(BO_3)_4$ have been synthesized by conventional solid-state reaction. The crystalline phase for the resulting powders was identified using an X-ray diffraction $system^1$. Their photoluminescence properties under the excitation of UV ray were investigated. The Eu, Tb or Tm-doped $GdCa_3(GaO)_3(BO_3)_4$ emits efficient red, green or blue light, respectively. It was observed that the optimum concentration of Eu or Tb activator for the borate host was much higher than other $Eu^{3+}$ or $Tb^{3+}-doped$ phosphors.

  • PDF

A STUDY ON TRANSPORTATION OF APICAL FORAMEN AFTER OVERINSTRUMENTATION BY PROFILE® ;PROTAPERTM AND K3TM IN SIMULATED CANALS WITH DIFFERENT CURVATURES (ProFile®, ProTaperTM 및 K3TM Ni-Ti 파일의 과기구 조작이 치근단공 변위에 미치는 영향)

  • Yang, Hyun;Yang, In-Seok;Hwang, Yun-Chann;Hwang, In-Man;Yoon, Suk-Ja;Kim, Won-Jae;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.2
    • /
    • pp.87-94
    • /
    • 2007
  • This study was done to evaluate transportation of the apical foramen after 0.5 mm overinstrumentation by ProFile, ProTaper and $K^3$ in simulated resin root canal. Sixty simulated resin root canal with a curvature of J and S-shape were divided into two groups. Each group consisted of three subgroups with 10 blocks according to the instruments used: $ProFile^{(R)},\;ProTaper^{TM},\;and\;K^{3TM}$. Simulated resin root canal was prepared by ProFile, ProTaper and $K^3$ with 300 rpm by the crown-down preparation technique. Pre- and post-instrumentation apical foramen images were overlapped and recorded with Image-analyzing microscope 100X (Camcope, Sometech Inc, Korea). The amounts of difference in width and dimension on overlapped images were measured after reference points were determined by Image Analysis program ($Image-Pro^{(R)}$ Express, Media Cybernetic, USA). Data were analyzed using Kruskal-Wallis and Mann-Whitney U-test. The results suggest that ProFile showed significantly less canal transportation and maintained original apical foramen shape better than $K^3$ and ProTaper.

Electrical Conductivity of $(ZrO_2)_x-(Tm_2O_3)_y$ System ($(ZrO_2)_x-(Tm_2O_3)_y$계의 전기전도도)

  • Eun Kyung Cho;Won Yang Chung;Keu Hong Kim;Seung Koo Cho;Jae Shi Choi
    • Journal of the Korean Chemical Society
    • /
    • v.31 no.6
    • /
    • pp.498-502
    • /
    • 1987
  • Electrical conductivities of $(ZrO_2)_x-(Tm_2O_3)_y$ systems containing 1, 3 and 5mol% of $ZrO_2$ have been measured as a function of temperature and of oxygen partial pressure at temperatures from 600 to 1,100$^{\circ}$C and oxygen partial pressures from $10^{-5}$ to $2{\times}10^{-1}atm$. Plots of log conductivity vs. 1/T are found to be linear and average activation energy is 1.51 eV. The electrical conductivity dependences on PO$_2$ are different at two temperature regions, indicating ${\sigma}{\alpha}PO_2^{1/5.3}$ and ${\sigma}{\alpha}PO_2^{1/10.7}$ at high-and low-temperature regions, respectively. The defect of $(ZrO_2)_x-(Tm_2O_3)_y$ system is $V_{Tm}^{'''}$ and an electron hole is suggested as a carrier at high temperature region. At low temperature region, a mixed ionic and hole conduction is reasonable.

  • PDF

Evaluating the usefulness of BinkieRTTM (oral positioning stent) for Head and Neck Radiotherapy (두경부암 환자 방사선 치료 시 BinkieRTTM(구강용 고정장치)에 대한 유용성 평가)

  • GyeongJin Lee;SangJun Son;GyeongDal Lim;ChanYong Kim;JeHee Lee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.34
    • /
    • pp.21-30
    • /
    • 2022
  • Purpose: The purpose of this study is to evaluate the effectiveness of oral positioning stent, the BinkieRTTM in radiation treatment for head and neck cancer patients in terms of tongue positions reproducibility, tongue doses and material properties. Materials and Methods: 24 cases using BinkieRTTM during radiation treatments were enrolled. The tongue was contoured on planning CT and CBCT images taken every 3 days during treatment, and then the DSC and center of tongue shift values were analyzed to evaluate the reproducibility of the tongue. The tongue dose was compared in terms of dose distribution when using BinkieRTTM and different type of oral stents (mouthpiece, paraffin wax). Randomly selected respective 10 patients were measured tongue doses of initial treatment plan for nasal cavity and unilateral parotid cancer. Finally, In terms of material evaluation, HU and relative electron density were identified in RTPS. Results: As a result of DSC analysis, it was 0.8 ± 0.07, skewness -0.8, kurtosis 0.61, and 95% CI was 0.79~0.82. To analyze the deviation of the central tongue shift during the treatment period, a 95% confidence interval for shift in the LR, SI, and AP directions were indicated, and a one-sample t-test for 0, which is an ideal value in the deviation(n=144). As a result of the t-test, the mean and SD in the LR and SI directions were 0.01 ± 0.14 cm (p→.05), 0.03 ± 0.25 cm (p→.05), and -0.08 ± 0.25 cm (p ←.05) in the AP direction. In the case of unilateral parotid cancer patients, the Dmean to the tongue of patients using BinkieRTTM was 16.92% ± 3.58% compared to the prescribed dose, and 23.99% ± 10.86% of patients with Paraffin Wax, indicating that the tongue dose was relatively lower when using BinkieRTTM (p←.05). On the other hand, among nasal cavity cancer patients, the Dmean of tongue dose for patients who used BinkieRTTM was 4.4% ± 5.6%, and for those who used mouthpiece, 5.9% ± 6.8%, but it was not statistically significant (p→.05). The relative electron density of Paraffin Wax, BinkieRTTM and Putty is 0.94, 0.99, 1.26 and the mass density is 0.95, 0.99 and 1.32 (g/cc), Transmission Factor is 0.99, 0.98, 0.96 respectively. Conclusion: The result of the tongue DSC analysis over the treatment period was about 0.8 and Deviation of the center of tongue shifts were within 0.2 cm, the reproducibility was more likely excellent. In the case of unilateral head and neck cancer patients, it was found that the use of BinkieRTTM rather than Paraffin Wax or Putty can reduce the unnecessary dose irradiated to the tongue. This study might be useful to understand of BinkieRTTM's properties and advantages. And also it could be another considered option as oral stent to keep the reproducibility of tongue and reducing dose during head and neck radiation treatments.

A Study on Electrooptic Guided-Wave TE-TM Mode Converter (전기광학효과를 이용한 광도파로형 TE-TM 모드 변환기에 관한 연구)

  • Hong Sik Jung
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.30A no.2
    • /
    • pp.29-35
    • /
    • 1993
  • A guided-wave TE to TM mode converter was demonstrated by using of the off-diagonal electrooptic coefficients in LiTaO$_{3}$. The input mode is coupled to the other orthogonal mode by the electrooptically induced off-diagonal polarizability. Compared with LiNbO$_{3}$, LiTaO$_{3}$ provides a smaller birefringence and thus a larger phase match period and larger optical bnadwidth. A novel electrode structure allowed a first-order Bragg-coupling phase matching. TE/TM mode conversion efficiency of 90% at 25 [V] was demonstrated with ${\lambda}$=0.63$\mu$m He-Ne laser.

  • PDF

Environmental Fatigue Evaluation of Top-Mounted In-Core Instrumentation Nozzle (상부 탑재형 노내계측기 노즐의 환경피로평가)

  • Yoon, Hyo-Sub;Kim, Jong-Min;Maeng, Cheol-Soo;Kim, Gee-Seok;Kim, Hyun-Min
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.29 no.3
    • /
    • pp.245-252
    • /
    • 2016
  • The development of Top-Mounted In-Core Instrumentation(TM-ICI) is an ongoing project to reduce the risk due to severe accidents by inserting the instrumentation into a reactor closure head instead of a reactor bottom head. As part of this project, environmental fatigue analyses for TM-ICI nozzle have been performed using two methods of NUREG/CR-6909 and Code Case N-761. TM-ICI nozzle is subjected to transient loads for level A, level B and test conditions that should be evaluated for a fatigue analysis. It is found that a cumulative usage factor considering reactor coolant environment for TM-ICI nozzle is evaluated as less than 1, which is ASME Code allowable criteria of a fatigue analysis.

A Study on the Relationship between Organizational Performance and Organizational Communication in Public Libraries: Based on Service Quality Measured with LibQUAL+TM (공공도서관 조직성과와 조직 커뮤니케이션과의 관계 연구: LibQUAL+TM 모형에 따른 서비스 품질을 중심으로)

  • Kim, Jihae;Kim, Giyeong
    • Journal of the Korean Society for information Management
    • /
    • v.31 no.3
    • /
    • pp.65-87
    • /
    • 2014
  • Organizational communication is an element of organizational structure formation; it is also a process of achieving organizational goals through the information sharing among the staff members in the organization as a social system. Organizational performance is a multidimensional concept composed of efficiency and effectiveness and satisfaction. Effectiveness implies service quality and the degree of goal achievement. Service quality by using the $LibQUAL+^{TM}$ model can be considered as an objective performance measure for libraries. This study aims to identify the effect of organizational communication in public libraries on service quality as a performance measure using the $LibQUAL+^{TM}$ model through statistical analyses of the results from questionnaire surveys of librarieans and users in 8 public libraries in Seoul metropolitan area. The result says the characteristics of organizational communication(upward, horizontal, downward communication) affects the three elements in the library service quality, such as affect of service, information control and library as place.