• Title/Summary/Keyword: Titanium implant

Search Result 577, Processing Time 0.028 seconds

Quantitative evaluation of MRI distortion using orthopedic prosthetic metal (정형보철용 금속을 이용한 자기공명영상왜곡의 정량적 평가)

  • Kim, Hyeonggyun
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.1
    • /
    • pp.57-62
    • /
    • 2013
  • Despite the many advantages of magnetic resonance imaging in orthopedic prosthetic body image distortion to the differences in the magnetic susceptibility occurs. Attached to the phantom and pork produced by the same $65{\times}15{\times}2mm$ stainless steel and titanium specimen examined the relationship between magnetic resonance imaging and phantom images, the signal intensity changes of the subcutaneous tissue, fat-suppressed quantitative assessment of the degree through the length of image distortion and pig bones. Stainless steel to titanium to 2.8 times 4.4 times in the longitudinal direction than in the direction of the height of large image distortion, signal strength is relatively low 58.5%. Normal 56.2% compared to the subcutaneous tissue, fat-suppressed, were stainless steel 16.04%, 54.53% titanium. Experimental results than the diagnostic value of magnetic resonance imaging (MRI) images of stainless steel with a titanium metal if better could see.

The bactericidal effect of an atmospheric-pressure plasma jet on Porphyromonas gingivalis biofilms on sandblasted and acid-etched titanium discs

  • Lee, Ji-Yoon;Kim, Kyoung-Hwa;Park, Shin-Young;Yoon, Sung-Young;Kim, Gon-Ho;Lee, Yong-Moo;Rhyu, In-Chul;Seol, Yang-Jo
    • Journal of Periodontal and Implant Science
    • /
    • v.49 no.5
    • /
    • pp.319-329
    • /
    • 2019
  • Purpose: Direct application of atmospheric-pressure plasma jets (APPJs) has been established as an effective method of microbial decontamination. This study aimed to investigate the bactericidal effect of direct application of an APPJ using helium gas (He-APPJ) on Porphyromonas gingivalis biofilms on sandblasted and acid-etched (SLA) titanium discs. Methods: On the SLA discs covered by P. gingivalis biofilms, an APPJ with helium (He) as a discharge gas was applied at 3 different time intervals (0, 3, and 5 minutes). To evaluate the effect of the plasma itself, the He gas-only group was used as the control group. The bactericidal effect of the He-APPJ was determined by the number of colony-forming units. Bacterial viability was observed by confocal laser scanning microscopy (CLSM), and bacterial morphology was examined by scanning electron microscopy (SEM). Results: As the plasma treatment time increased, the amount of P. gingivalis decreased, and the difference was statistically significant. In the SEM images, compared to the control group, the bacterial biofilm structure on SLA discs treated by the He-APPJ for more than 3 minutes was destroyed. In addition, the CLSM images showed consistent results. Even in sites distant from the area of direct He-APPJ exposure, decontamination effects were observed in both SEM and CLSM images. Conclusions: He-APPJ application was effective in removing P. gingivalis biofilm on SLA titanium discs in an in vitro experiment.

Effect of various types of dental magnetostrictive ultrasonic scaler tip on surface characteristics of titanium (여러가지 치과용 자기변형 초음파 스케일러 팁이 티타늄 표면특성에 미치는 영향)

  • Min-Cheol Yang;Seok-Hwan Jeong;Seol Kim;Seung-Hwan Seol;Seung-Kyu Lee;Sang-Joun Yu;Byung-Ock Kim
    • Journal of the Korean institute of surface engineering
    • /
    • v.57 no.4
    • /
    • pp.296-305
    • /
    • 2024
  • The aim of this in vitro study was to evaluate the changes in the roughness and weight of titanium discs treated with 3 different types of magnetostrictive ultrasonic scaler tip. Eighty identical disks (10 mm in diameter), 50 for surface roughness and 30 for weight change, were investigated in this study. For this study, 3 types of scaler tip were used as follows; Powerline(FSI-PWR-1000), Slimline(FSI-SLI-1000), and Thinsert(-16 00037374). The power was set to high power(HP), medium power(MP), and low power(LP), in the blue zone recommended by the manufacturer. Surface topography analysis was carried out using scanning electron microscopy (SEM). Surface roughness measurements, the average surface roughness (Ra) and mean roughness profile depth (Rz), were compared between treated and non-treated surfaces with a profilometer. A PowerLINE-MP of magnetostrictive ultrasonic scalers for implant patients might be recommended when considering changes in the roughness and weight of titanium discs.

Biological response of primary rat calvarial cell by surface treatment of Ti-8Ta-8Nb alloy (Ti-8Ta-3Nb 합금의 표면처리에 의한 백서 두개관 세포의 반응)

  • Kim, Hae-Jin;Son, Mee-Kyoung;Park, Ji-Il;Chung, Hyun-Ju;Kim, Young-Joon
    • Journal of Periodontal and Implant Science
    • /
    • v.38 no.4
    • /
    • pp.595-602
    • /
    • 2008
  • Purpose: Ti-6Al-4V alloy is widely used as an implant material because of its good biocompatibility and good mechanical property compared with commercial pure titanium. Otherwise, toxicity of aluminum and vanadium in vivo has been reported. Ti-8Ta-3Nb alloy is recently developed in the R&D Center for Ti and Special Alloys and it was reported that this alloy has high mechanical strength, no cytotoxicity and similar biocompatibility to commercial pure titanium, but many studies are needed for its clinical use. In these experiment, we carried out different surface treatment on each Ti-8Ta-3Nb alloy disks, then cultured cell on it and assessed biological response. Materials and Methods: cpTi, Ti-6Al-4V, Ti-8Ta-3Nb alloy disks were prepared and carried out sandblasting and acid etching (SLA) or alkali-heat treatment (AH) on the Ti-8Ta-3Nb alloy disks. We cultured primary rat calvarial cells on each surface and assessed early cell attachment and proliferation by scanning electron microscopy, cell proliferation, alkaline phosphatase activity. Result: The rates of cell proliferation on the cpTi, Ti-8Ta-3Nb AH disks were higher than others (p<0.05) and alkaline phosphatase activity was significantly enhanced on the Ti-STa-8Nb AH disks(p<0.05). Conclusion: Most favorable cell response was shown on the Ti-8Ta-3Nb AH surfaces. It is supposed that alkali-heat treatment of the Ti-8Ta-3Nb alloy could be induced earlier bone healing and osseointegration than smooth surface.

Corrosion Characteristics of Titanium Alloys for Medical Implant (생체용 Ti 합금의 부식특성)

  • Han, Jun-Hyun;Lee, Kyu Hwan;Shin, Myung Chul
    • Analytical Science and Technology
    • /
    • v.9 no.2
    • /
    • pp.192-197
    • /
    • 1996
  • The purpose of this study is to develop new V-free Ti alloys which have good mechanical properties and corrosion resistance. Although pure Ti has an excellent biocompatibility and corrosion resistance in body, it is inferior to Ti alloys in mechanical properties, and Ti-6Al-4V which has good mechanical properties was known to be cytotoxic due to the alloying element V. New Ti based alloys which do not contain the toxic metallic components were developed by the alloy design technique. Their corrosion and mechanical characteristics were compared with pure Ti and Ti-6Al-4V in this study. The results showed that Ti-20Zr-3Nb-3Ta-0.2Pd-1In and Ti-5AI-4Zr-2.5Mo exhibit good mechanical oroperties and an excellent corrosion resistance in 0.9% NaCl solution.

  • PDF

Corrosion Charateristics of PEO-treated Ti-6Al-4V Alloy in Solution Containing Si and Mg Ions

  • Park, Seon-Yeong;Choe, Han-Cheol
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2017.05a
    • /
    • pp.153-153
    • /
    • 2017
  • The application of the coating supports the mechanical characteristics of the implant, and various materials and coatings are currently being used in the implant in a way to accelerate adhesion. Especially, plasma electrolytic oxidation (PEO) coating has been proposed continually with good surface treatment of titanium alloys. Also, the PEO process can incorporate Ca and P ions on the titanium surface through variables varied factor. PEO process for bioactive surface has carried out in electrolytes containing Ca and P ions. Natural bone is composed of mineral elements such as Mg, Si, Zn, Sr, and Mn, etc. Especially, Mg and Si of these elements play role in bone formation and growth after clinical implantation of bio-implants. In this study, corrosion charateristics of PEO-treated Ti-6Al-4V alloy in solution containing Si and Mg ions has been investigated using several experimental techniques. The PEO-treated surfaces were identified by X-ray diffraction, using a diffractometer (XRD, Philips X' pert PRO, Netherlands) with Cu $K{\alpha}$ radiation. The morphology was observed by field-emission scanning electron microscopy (FE-SEM, Hitachi 4800, Japan) and energy-dispersive X-ray spectroscopy (EDX, Oxford ISIS 310, England). The potentiodynamic polarization and AC impedance tests for electrochemical degradations were carried out in 0.9% NaCl solution at similar body temperature using a potentiostat with a scan rate of 1.67mV/s and potential range from -1500mV to + 2000mV.

  • PDF

Biological Effects of Different Thin Layer Hydroxyapatite Coatings on Anodized Titanium

  • Sohn, Sung-Hwa;Jun, Hye-Kyoung;Kim, Chang-Su;Kim, Ki-Nam;Ryu, Yeon-Mi;Lee, Seung-Ho;Kim, Yu-Ri;Seo, Sang-Hui;Kim, Hye-Won;Shin, Sang-Wan;Ryu, Jae-Jun;Kim, Meyoung-Kon
    • Molecular & Cellular Toxicology
    • /
    • v.1 no.4
    • /
    • pp.237-247
    • /
    • 2005
  • Several features of the implant surface, such as roughness, topography, and composition play a relevant role in implant integration with bone. This study was conducted in order to determine the effects of various thin layer hydroxyapatite (HA) coatings on anodized Ti surfaces on the biological responses of a human osteoblast-like cell line (MG63). MG63 cells were cultured on A (100 nm HA coating on anodized surface), B (500-700 nm HA coating on anodized surface), C ($1{\mu}m$ HA coating on anodized surface), and control (non HA coating on anodized surface) Ti. The morphology of these cells was assessed by SEM. The cDNAs prepared from the total RNAs of the MG63 were hybridized into a human cDNA microarray (1,152 elements). The appearances of the surfaces observed by SEM were different on each of the four dental substrate types. MG63 cells cultured on A, C and control exhibited cell-matrix interactions. It was B surface showing cell-cell interaction. In the expression of several genes were up-, and down-regulated on the different surfaces. The attachment and expression of key osteogenic regulatory genes were enhanced by the surface morphology of the dental materials used.

The Experimental Study of Effects of Irradiation on Osseointegration (방사선조사가 임프란트의 골유착에 미치는 영향에 관한 실험적 연구)

  • Park Kwan-Soo;Lee Sang-Rae;Hwang Eui-Hwan
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.1
    • /
    • pp.119-147
    • /
    • 1999
  • The purpose of this study was to investigate the effects of the Co-60 γ irradiation on the osseointegration. 2.0 mm titanium alloy screw implants(Sankin Industry Co. Ltd., Japan) were placed in the tibial metaphysis of the rabbits, bilaterally. The mean length of the implants was 6.0 mm. The right tibia was irradiated with a single dose of 15Gy from 60Co teletherapic machine at 5th postoperative day. The experimental group was irradiated tibia. The control group was non­irradiated tibia. To observe the phase of bone formation, the bone labeling by intramuscular injection of 20mg/Kg of Tetracycline, Calcein, Alizarin red S, was performed. The rabbits were sacrificed on the 1st, 2nd, 4th, 6th, 8th week and the tibia including implants were taken, and then the specimens were examined by the microradiography, light microscopy, and fluorescent microscopy. The obtained results were as follows: 1. There were connective tissue between bone and titanium at 1st week, in both group. Especially, the many empty lacunae without nucleus and obscure cytoplasm in experimental group, were observed. 2. The osteons were observed at 4th week in control group, and at 6th week in experimental group. The bone formation in experimental group was retarded as compared to the control group. 3. In fluorescent microscopy, bone labelling band was observed as linear, arc or concentric shape. Occasionary interrupted labelling band was observed, which is demonstrated bone remodeling. 4. In microradiographic examination, the radiolucent image was found between bone and implant with widening of bone marrow spaces as compared to the control group.

  • PDF

Comparing the Results of Using Bioabsorbable Magnesium Screw with Those Using a Titanium Screw for the Treatment of Mild to Moderate Hallux Valgus: Short-term Follow-Up (경도-중등도 무지외반증 환자의 생체 흡수성 마그네슘 나사못과 티타늄 나사못을 사용한 수술의 단기 결과 비교)

  • Hong, Sung yup;Kim, Gab-Lae;Han, Woosol
    • Journal of Korean Foot and Ankle Society
    • /
    • v.24 no.3
    • /
    • pp.107-112
    • /
    • 2020
  • Purpose: Hallux valgus (HV) is a common foot deformity that causes pain in the first metatarsophalangeal joint. Distal metatarsal osteotomies are commonly performed as a treatment. This retrospective study compared the clinical and radiological results of bioabsorbable magnesium (Mg) versus titanium (Ti) screw fixation for modified distal chevron osteotomy in HV. Materials and Methods: Forty-nine patients, who underwent modified distal chevron osteotomy for HV in 2018 and 2019, were reviewed retrospectively. Bioabsorbable Mg screw fixation was applied in 20 patients (22 feet), and a traditional Ti compression screw was applied in 29 patients (40 feet). The patients were followed up for at least six months. The clinical results were evaluated using the American Orthopaedic Foot and Ankle Society hallux metatarsophalangeal-interphalangeal (AOFAS-MTP-IP) scale and a visual analogue scale (VAS). The hallux valgus angle (HVA), intermetatarsal angle (IMA), and distal metatarsal articular angle (DMAA) were measured before, after surgery, and at the six months follow-up. Results: The AOFAS-MTP-IP scale and VAS points were improved in both groups, with no significant difference between them. At the six-month follow-up, HVA, IMA, and DMAA were similar. Bone union was confirmed in both groups, and there were no significant major complications in both groups. Four people in the Ti screw group underwent implant removal surgery. Conclusion: Bioabsorbable Mg screws showed comparable clinical, radiologic results to Ti standard screws six months after distal modified chevron osteotomy. These screws are an alternative fixation material that can be used safely and avoid the need for implant removal operations.

Modified Pharmacokinetic/Pharmacodynamic model for electrically activated silver-titanium implant system

  • Tan, Zhuo;Orndorff, Paul E.;Shirwaiker, Rohan A.
    • Biomaterials and Biomechanics in Bioengineering
    • /
    • v.2 no.3
    • /
    • pp.127-141
    • /
    • 2015
  • Silver-based systems activated by low intensity direct current continue to be investigated as an alternative antimicrobial for infection prophylaxis and treatment. However there has been limited research on the quantitative characterization of the antimicrobial efficacy of such systems. The objective of this study was to develop a semi-mechanistic pharmacokinetic/pharmacodynamic (PK/PD) model providing the quantitative relationship between the critical system parameters and the degree of antimicrobial efficacy. First, time-kill curves were experimentally established for a strain of Staphylococcus aureus in a nutrientrich fluid environment over 48 hours. Based on these curves, a modified PK/PD model was developed with two components: a growing silver-susceptible bacterial population and a depreciating bactericidal process. The test of goodness-of-fit showed that the model was robust and had good predictability ($R^2>0.7$). The model demonstrated that the current intensity was positively correlated to the initial killing rate and the bactericidal fatigue rate of the system while the anode surface area was negatively correlated to the fatigue rate. The model also allowed the determination of the effective range of these two parameters within which the system has significant antimicrobial efficacy. In conclusion, the modified PK/PD model successfully described bacterial growth and killing kinetics when the bacteria were exposed to the electrically activated silver-titanium implant system. This modeling approach as well as the model itself can also potentially contribute to the development of optimal design strategies for other similar antimicrobial systems.