• Title/Summary/Keyword: Titanium implant

Search Result 577, Processing Time 0.026 seconds

Effects of noninvasive electrical stimulation on osseointegration of endosseous implants;A histomorphometric evaluation in the rabbit tibia (비침습적인 전기자극이 임프란트의 골융합에 미치는 영향;토끼경골에서의 조직계측학적 평가)

  • Sohn, Sung-Bae;Park, Jin-Woo;Suh, Jo-Young
    • Journal of Periodontal and Implant Science
    • /
    • v.35 no.3
    • /
    • pp.635-648
    • /
    • 2005
  • The procedure that enhances osteogenesis and shortens the healing period is required for successful implant therapy. It has been introduced that osteogenesis is enhanced by the generation of electric field. Many researchers have demonstrated that application of electric and electromagnetic field promote bone formation. It also has been shown that electrical stimulation enhances peri-implant bone formation. Recently, several investigators have reported that noninvasive electrical stimulation using negatively charged electret such as polytetrafluoroethylene(PTFE) promotes osteogenesis. Therefore, we were interested in the effect of noninvasive electrical stimulation using negatively charged electret on the periimplant bone healing. After titanium implant were installed in the proximal tibial metaphysis of New Zealand white rabbit, negatively charged PTFE membrane fabricated by corana dischage was inserted into the inner hole of the experimental implant and noncharged membrane was applied into control implant. After 4 weeks of healing, histomorphometric analysis was performed to evaluate peri-implant bone response. The histomorphometric evaluations demonstrated experimental implant tended to have higher values in the total bone-to-implant contact ratio(experimental ; $49.9{\pm}13.52%$ vs control ; $37.5{\pm}19.44%$) , the marrow bone contact ratio(experimental ; $34.94{\pm}13.32%$ vs control ; $24.15{\pm}13.69%$), amount of newly formed bone in the endosteal region(experimental ; $1.00{\pm}0.30mm$ vs control ; $0.61{\pm}0.24mm$) and bone area in the medullary canal(experimental ; $13.55{\pm}4.98%$ vs control ; $9.03{\pm}3.05%$). The mean values of the amount of newly formed bone(endosteal region) and bone area(medullary canal) of the experimental implant demonstrated a statistically significant difference as compared to the control implant(p<0.05). In conclusion, noninvasive electrical stimulation using negatively charged electret effectively promoted peri-implant new bone formation in this study. This method is expected to be used as one of the useful electrical stimulation for enhancing bone healing response in the implant therapy

The effect of photodynamic therapy on Aggregatibacter actinomycetemcomitans attached to surface-modified titanium

  • Cho, Kyungwon;Lee, Si Young;Chang, Beom-Seok;Um, Heung-Sik;Lee, Jae-Kwan
    • Journal of Periodontal and Implant Science
    • /
    • v.45 no.2
    • /
    • pp.38-45
    • /
    • 2015
  • Purpose: The purpose of this study was to evaluate the effect of photodynamic therapy (PDT) using erythrosine and a green light emitting diode (LED) light source on biofilms of Aggregatibacter actinomycetemcomitans attached to resorbable blasted media (RBM) and sandblasted, large-grit, acid-etched (SLA) titanium surfaces in vitro. Methods: RBM and SLA disks were subdivided into four groups, including one control group and three test groups (referred to as E0, E30, E60), in order to evaluate the effect of PDT on each surface. The E0 group was put into $500{\mu}L$ of $20{\mu}M$ erythrosine for 60 seconds without irradiation, the E30 group was put into erythrosine for 60 seconds and was then irradiated with a LED for 30 seconds, and the E60 group was put into erythrosine for 60 seconds and then irradiated with a LED for 60 seconds. After PDT, sonication was performed in order to detach the bacteria, the plates were incubated under anaerobic conditions on brucella blood agar plates for 72 hours at $37^{\circ}C$, and the number of colony-forming units (CFUs) was determined. Results: Significant differences were found between the control group and the E30 and E60 groups (P<0.05). A significantly lower quantity of CFU/mL was found in the E30 and E60 groups on both titanium disk surfaces. In confocal scanning laser microscopy images, increased bacterial death was observed when disks were irradiated for a longer period of time. Conclusions: These findings suggest that PDT using erythrosine and a green LED is effective in reducing the viability of A. actinomycetemcomitans attached to surface-modified titanium in vitro.

Preparation of Metal Injection Molded Dental Components using Spheroidized Ti Powders by Plasma Process (플라즈마 공정으로 구상화된 티타늄 분말과 금속사출성형 공정을 이용한 치과용 부품 제조)

  • Gwak, Ji-Na;Yang, Sangsun;Yun, Jung-Yeul;Kim, Ju-Yong;Park, Seongjin;Kim, Hyun-Seung;Kim, Yong-Jin;Park, Yong-Ho
    • Journal of Powder Materials
    • /
    • v.20 no.6
    • /
    • pp.467-473
    • /
    • 2013
  • This research presents a preparation method of dental components by metal injection molding process (MIM process) using titanium scrap. About $20{\mu}m$ sized spherical titanium powders for MIM process were successfully prepared by a novel dehydrogenation and spheroidization method using in-situ radio frequency thermal plasma treatment. The effects of MIM process parameters on the mechanical and biological properties of dental components were investigated and the optimum condition was obtained. After sintering at $1250^{\circ}C$ for 1 hour in vacuum, the hardness and the tensile strength of MIMed titanium components were 289 Hv and 584 MPa, respectively. Prepared titanium dental components were not cytotoxic and they showed a good cell proliferation property.

EFFECTS OF VARIOUS SURFACE TREATMENTS FOR TITANIUM ON SURFACE MICRO ROUGHNESS, STATIC WETTABILITY, FIBRONECTIN ADSORPTION (표면 처리 방법에 따른 타이타늄의 미세 표면 거칠기, 표면 젖음성, fibronectin 흡착량에 미치는 영향)

  • Shin Hwa-Sub;Kim Young-Su;Shin Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.4
    • /
    • pp.443-454
    • /
    • 2006
  • Purpose: This study aims to get the fundamental data which is necessary to the development direction of implant surface treatment hereafter, based on the understanding the surface structure and properties of titanium which is suitable for the absorption of initial tissue fluid by researching effects of additional surface treatments fir sandblasted with large git and acid-etched(SLA) titanium on surface micro-roughness, static wettability, fibronectin adsorption Materials and Method: In the Control groups, the commercial pure titanium disks which is 10mm in diameter and 2mm in thickness were treated with HCI after sandblasting with 50$\mu$m $Al_2O_3$. The experiment groups were made an experiment each by being treated with 1) 22.5% nitric acid according to SLA+ASTM F86 protocol, 2) SLA+30% peroxide, 3) SLA+NaOH, 4) SLA+ Oxalic acid, and 5) SLA+600$^{\circ}C$ heating. In each group, the value of Ra and RMS which are the gauges of surface roughness was measured, surface wettability was measured by analyzing with Sessile drop method, and fibronectin adsorption was measured with immunological assay. The significance of each group was verified by (SPSS, ver.10.0 SPSS Inc.) Kruskal-Wallis Test. (α=0.05) And the correlation significance between Surface micro-roughness and surface wettability. surface roughness and fibronectin adsorption, and surface wettability and fibronectin adsorption was tested by Spearman's correlation analysis. Result: All measure groups showed the significant differences in surface micro-roughness, surface wettability, and fibronectin adsorption. (p<0.05) There was no significance in correlation among the surface micro-roughness, surface wettability, and fibronectin adsorption. (p>0.05) Conclusion: Surface micro-roughness and surface wettability rarely affected the absorption of initial tissue fluid on the surface of titanium.

Osteogenic Gene Expression on Anodizing Titanium Surface (양극산화 처리된 타이타늄 표면에서 골형성 유전자 발현)

  • Kim, Won-Seok;Kim, Young-Seok;Jeon, Seong-Bae;Jun, Sang-Ho;Lee, Eui-Suk;Jang, Hyon-Seok;Kwon, Jong-Jin;Rim, Jae-Suk
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.34 no.2
    • /
    • pp.91-99
    • /
    • 2012
  • Purpose: The purpose of this study was to evaluate the expression of osteogenic genes associated with bone regeneration on anodizing titanium surface. Methods: $20{\times}20{\times}1$ (mm) commercially pure titanium plate was made, one group was pure titanium, second group was punched, and last group was punched and anodized by electrochemical method. Through the osteogenic cell culture model, the expression of extracellular matrix proteins, such as bone morphogenetic protein-2, bone sialoprotein, aggrecan, osteocalcin, Alkaline phosphatase, collagen I had been evaluated by Real-time polymerase chain reaction, and the morphology of growing cells was evaluated by scanning electron microscopy. Results: The attachment of mesenchymal stem cell was even and well-oriented on all Ti surfaces. The osteogene expression was increased on punching groups but, decreased on anodizing surfaces in 3 week samples. Conclusion: Punched anodizing Ti has possibility be using as a dental implant material, but further in vivo study would be needed.

Surface characteristics and bioactivity of an anodized titanium surface

  • Kim, Kyul;Lee, Bo-Ah;Piao, Xing-Hui;Chung, Hyun-Ju;Kim, Young-Joon
    • Journal of Periodontal and Implant Science
    • /
    • v.43 no.4
    • /
    • pp.198-205
    • /
    • 2013
  • Purpose: The aim of this study was to evaluate the surface properties and biological response of an anodized titanium surface by cell proliferation and alkaline phosphatase activity analysis. Methods: Commercial pure titanium (Ti) disks were prepared. The samples were divided into an untreated machined Ti group and anodized Ti group. The anodization of cp-Ti was formed using a constant voltage of 270 V for 60 seconds. The surface properties were evaluated using scanning electron microscopy, X-ray photoelectron spectroscopy, and an image analyzing microscope. The surface roughness was evaluated by atomic force microscopy and a profilometer. The contact angle and surface energy were analyzed. Cell adhesion, cell proliferation, and alkaline phosphatase activity were evaluated using mouse $MC_3T_3-E_1$ cells. Results: The anodized Ti group had a more porous and thicker layer on its surface. The surface roughness of the two groups measured by the profilometer showed no significant difference (P>0.001). The anodized Ti dioxide ($TiO_2$) surface exhibited better corrosion resistance and showed a significantly lower contact angle than the machined Ti surface (P>0.001). Although there was no significant difference in the cell viability between the two groups (P>0.001), the anodized $TiO_2$ surface showed significantly enhanced alkaline phosphatase activity (P<0.001). Conclusions: These results suggest that the surface modification of Ti by anodic oxidation improved the osteogenic response of the osteoblast cells.

Effect of abutment types and resin cements on the esthetics of implant-supported restorations

  • Asena Ceken;Hamiyet Kilinc;Sedanur Turgut
    • The Journal of Advanced Prosthodontics
    • /
    • v.15 no.3
    • /
    • pp.114-125
    • /
    • 2023
  • PURPOSE. The aim of the study was to evaluate the optical properties of new generation (3Y-TZP) monolithic zirconia (MZ) with different abutment types and resin cement shades. MATERIALS AND METHODS. A1/LT MZ specimens were prepared (10 × 12 × 1 mm, N = 30) and divided into 3 groups according to cement shades as transparent (Tr), yellow (Y) and opaque (O). Abutment specimens were obtained from 4 different materials including zirconia (Group Z), hybrid (Group H), titanium (Group T) and anodized yellow titanium (Group AT). MZ and abutment specimens were then cemented. L*, a*, and b* parameters were obtained from MZ, MZ + abutment, and MZ + abutment + cement. ∆E001* (between MZ and MZ + abutment), ∆E002* (between MZ and MZ + abutment + cement) and ∆E003* (between MZ + abutment and MZ + abutment + cement) values were calculated. Statistical analyses included 2-way ANOVA, Bonferroni, and Paired Sample t-Tests (P < .05). RESULTS. Abutment types and resin cements had significant effect on L*, a*, b*, ∆E001*, ∆E002*, and ∆E003* values (P < .001). Without cementation, whereas zirconia abutment resulted in the least discoloration (∆E001* = 0.68), titanium abutment caused the most discoloration (∆E001* = 4.99). The least ∆E002* = 0.68 value was seen using zirconia abutment after cementation with yellow shaded cement. Opaque shaded cement caused the most color change (∆E003* = 5.24). Cement application increased the L* values in all groups. CONCLUSION. The least color change with/without cement was observed in crown configurations created with zirconia abutments. Zirconia and hybrid abutments produced significantly lower ∆E002* and ∆E003* values in combination with yellow shaded cement. The usage of opaque shaded cement in titanium/anodized titanium groups may enable the clinically unacceptable ∆E00* value to reach the acceptable level.

EVALUATION OF BONE RESPONSE BY RESONANCE FREQUENCY ANALYSIS OF ANODIZED IMPLANTS

  • Roh Hyun-Ki;Heo Seong-Joo;Rhyu In-Chul
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.6
    • /
    • pp.745-750
    • /
    • 2005
  • Statement of problem. Resonance frequency analysis has been increasingly served as a non-invasive and objective method for clinical monitoring of implant stability. Many clinical studies must be required for standardized data using RFA. Purpose. This study was performed to evaluate RFA value changes in two anodized implant groups. Material and method. Among a total of 24 implants, twelve screw shaped implants as a test group (H2-R8.5) were manufactured, which had a pitch-height of 0.4 mm, an outer diameter of 4.3 mm, a length of 8.5 mm, and external hexa-headed, were turned from 5 mm rods of commercially pure titanium (ASTM Grade IV, Warantec Co., Seoul, Korea), and another twelve implants as a control group were $Br{\aa}nemark$ Ti-Unite MK4 (diameter 4.0 mm, length 8.5 mm). Each group was installed in tibia of rabbit. Two implants were placed in each tibia (four implants per rabbit). Test two implants were inserted in right side and control two in left side. ISQ values were measured using $Osstell^{TM}$ (Integration Diagnostics Ltd. Sweden) during fixture installation, and 12 weeks later and evaluated the RFA changes. Results. Mean and SD of baseline ISQ values of test group were $75.0{\pm}3.4$ and $68.7{\pm}8.1$ for control group. Mean and SO of ISQ values 12 weeks after implant insertion were $73.2{\pm}4.7$ for test group and $72.6{\pm}3.9$ for control group. There were no statistically significant differences between groups in ISQ values after 3 months (P>0.05). From the data, RFA gains after 3 months were calculated, and there was statistically significant difference between groups (P<0.05). Conclusion. Although there were RFA changes between groups, implant stability after experimental period shows alike tendency and good bone responses.

Effect of Device Rigidity and Physiological Loading on Spinal Kinematics after Dynamic Stabilization : An In-Vitro Biomechanical Study

  • Chun, Kwonsoo;Yang, Inchul;Kim, Namhoon;Cho, Dosang
    • Journal of Korean Neurosurgical Society
    • /
    • v.58 no.5
    • /
    • pp.412-418
    • /
    • 2015
  • Objective : To investigate the effects of posterior implant rigidity on spinal kinematics at adjacent levels by utilizing a cadaveric spine model with simulated physiological loading. Methods : Five human lumbar spinal specimens (L3 to S1) were obtained and checked for abnormalities. The fresh specimens were stripped of muscle tissue, with care taken to preserve the spinal ligaments and facet joints. Pedicle screws were implanted in the L4 and L5 vertebrae of each specimen. Specimens were tested under 0 N and 400 N axial loading. Five different posterior rods of various elastic moduli (intact, rubber, low-density polyethylene, aluminum, and titanium) were tested. Segmental range of motion (ROM), center of rotation (COR) and intervertebral disc pressure were investigated. Results : As the rigidity of the posterior rods increased, both the segmental ROM and disc pressure at L4-5 decreased, while those values increased at adjacent levels. Implant stiffness saturation was evident, as the ROM and disc pressure were only marginally increased beyond an implant stiffness of aluminum. Since the disc pressures of adjacent levels were increased by the axial loading, it was shown that the rigidity of the implants influenced the load sharing between the implant and the spinal column. The segmental CORs at the adjacent disc levels translated anteriorly and inferiorly as rigidity of the device increased. Conclusion : These biomechanical findings indicate that the rigidity of the dynamic stabilization implant and physiological loading play significant roles on spinal kinematics at adjacent disc levels, and will aid in further device development.

ON THE SURFACE CHARACTERISTICS AND STABILITY OF IMPLANT TREATED WITH ANODIZING OXIDATION (양극산화 처리한 임플랜트의 표면 특성 및 골유착 안정성에 관한 연구)

  • Kim, Won-Sang;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.5
    • /
    • pp.549-560
    • /
    • 2006
  • Purpose : This experiment examined the effects of anodization on commercially pure titanium implant fixtures. Material & methods : The implant fixtures were anodized at three different voltage levels, producing three different levels of oxidation on the surface of the fixure. Implant were divided into four groups according to the level of oxidation. Group 1 consist of the control group of machined surface implants, Group 2 implants were treated by anodizing to 100 voltage, Group 3 implants were treated by anodizing oxidation to 200 voltage Group 4 implants were treated by anodizing oxidation to 350 voltage. Surface morphology was observed by Scanning Electron Microscope(SEM) and the surface roughness was measured using NanoScan $E-1000^{\circledR}$. Implantation of the fixtures were performed using New Zealand white rabbits. $Periotest^{\circledR}$ value(PTV) resonance frequency analysis(RFA), and removal torque were measured in 0, 2, 4, 8, 12 weeks after implantation. Results : The results of the study were as follows: 1. Values for the measured surface roughness indicate statistically significant differences in Ra, Rq, and Rt values among group 1, 2, 3, and 4 at the top portion of the thread,(p<0.05) while values at the base of the threads indicated no significant difference in these values. 2. A direct correlation between the firming voltage, and surface roughness and irregularities were observed using scanning electron microscope. 3. No statistically significant differences were found between test groups regarding $Periotest^{\circledR}$ values. 4. Analysis of the data produced by RFA, significant differences were found between group 1 and group 4 at 12 weeks after implantation.(p<0.05) Conclusions : In conclusion, no significant differences could be found among test groups up to a certain level of forming voltage threshold, beyond this firming voltage threshold, statistically significant differences occurred as the surface area of the oxide layer increased with the increase in surface porosity, resulting in enhanced bone response and osseointegration.