• Title/Summary/Keyword: Tissue conditioners

Search Result 8, Processing Time 0.029 seconds

A STUDY ON THE VISCO-ELASTIC PROPERTIES OF FOUR CURRENTLY USED TISSUE CONDITIONERS (수종의 조직 양화재에서 탄성 변형과 복원에 관한 연구)

  • Choi Sung-Ho;Shim June-Sung;Moon Hong-Seok;Chung Moon-Kyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.1
    • /
    • pp.35-47
    • /
    • 2003
  • The dimensional stability of tissue conditioners characterizes the ability of the materials to yield accurate functional impressions of oral mucosa. This study evaluated the viscoelastic property and the linear dimensional changes with the factor of time and thickness of tissue conditioners ($COE-COMFORT^{TM}$, Visco-gel. $COE-SOFT^{TM}$, Soft-Liner). The thickness of these materials were changed (1.5mm, 3.0mm) and the percentage changes in dimension were measured at 1h, 12h, 24h, 36h, 3day, 7day after specimen preparation. From the results large differences appear between the various tissue conditioners. The results suggest that the period recommended for forming functional impression would be 2-3days after insertion in the mouth. in addition. it is important to select tissue conditioners suitable for functional impression because of the wide range of dimensional stability among the materials.

COMPARISON OF THE GROWTH OF CANDIDA ALBICANS AMONG THE TISSUE CONDITIONERS (수종의 점막조정제간에 Candida albicans의 성장 양상 비교)

  • Jung, Bock-Young;Kang, Woo-Jin;Chung, Moon-Kyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.3
    • /
    • pp.453-466
    • /
    • 1995
  • The use of tissue conditioners has come into favor for preprosthetic treatment and the treatment of Denture stomatitis, but the major problem in the use of the tissue conditioner is the growth of C.albicans. To compare the growth of C.albicans according to the type and the wearing period of the tissue conditioner, three commercial tissue conditioners were relined to intraoral plates which were delivered to 14 smoking, 12 nonsmoking healthy men. Cultures were made from the conditioner surface at 2, 7, 14, 21 days after after intraoral placement. The frequency of positive culture and colony counts of C.albicans were measured by imprint culture technique. The following results were achieved : 1. The frequency of positive cluture had increased significantly for all materials used. 2. The frequency of positive culture had incresed significantly around 2,14 days for day for COE-Comfort, SR-Ivoseal. 3. There were no significant difference in the colony counts of C.albicans among the mate rials used. 4. There were an over-all increase with the wearing period of tissue conditioners and significant increase around 2, 7, 14 days for COE-Comfort, and 2, 14 days for SR-Ivoseal, viscogel in colony counts. 5. Smoking had no effect on the growth of C.albicans. That is, there were no difference among the materials used in the growth of C.albicans. In the clinical application of tissue conditioners, we should avoid a long term use of it, but in inevitable cases, special disinfection procedures should be considered.

  • PDF

An Experimental Study on the Effect of Tissue Conditioner on the Oral Mucosa (Tissue Conditioner가 구강조직에 미치는 영향에 관한 실험적 연구)

  • Kim, Chang-Whe
    • The Journal of the Korean dental association
    • /
    • v.17 no.9 s.124
    • /
    • pp.695-700
    • /
    • 1979
  • An experimental study was performed to study the tissue reactions to tissue conditioners in rabbits. Thirty rabbits were divided into three groups, 10, Hydro-cast group, 10, Coe-comfort group, and 10, heat-cured resin group. Tissue conditioners and heat-cured resin were embedded in the oral mucosa of rabbits. The tissue specimens were removed on 3rd, 7th, 14h, 21st and 28th day after embedding and examined under microscope after staining them with H-E stain, Van Gieson's stain, Masson's trichrome stain and PAS reaction. The results were as follows : 1. Tissue reactions to tissue conditioners were somewhat different from each other in the early stage, but, with the increase of the embedding period, the fibrous capsule was thickened in both. These tissue reactions were similar to those to heat-cured resin. 2. Newly formd fibrous components were stained deep-red with Van Gieson's stain and dark-green with Masson's trichrome stain. But their stainability was decreased as collagenous fibers became matured. 3. Newly formed fibrous components showed intense PAS reactivity, but PAS reactivity was reduced as the connective tissue capsule became completed.

  • PDF

THE INHIBITING EFFECT OF TISSUE CONDITIONER COMBINED WITH ANTIFUNGAL AGENTS ON THE GROWTH OF CANDIDA ALBICANS (항진균제를 첨가한 수종의 점막 조정제가 Candida albicans 성장 억제에 미치는 효과)

  • Chang Dae-Soon;Lee Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.32 no.2
    • /
    • pp.268-280
    • /
    • 1994
  • Tissue conditioners have been used for treatment of denture stomatitis caused by wearing of dentures. Early studies pointed out Candide albicans (C. albicans) as main etiologic factor, and antifugal agents were added for control of the species. But there is a little information about broad comparison on the effect of tissue conditioners and antifungal agents added. The purpose of the present study was to compare the inhibiting effect of four tissue conditioners and one temporary soft liner on the growth of C. albicans for treatment of denture stomatitis using gel diffusion method by measuring diameter of the zone of growth inhibition. Three antifungal agents were added to each material for evaluation of the effect of added agents. Finally, observation was made to evaluate the effect of the loss of antifungal elements by aging of the specimen. The results of this study were obtained as follows : 1. Tempo had remarkable antifungal effect showing the zone of growth inhibition as 2.35 mm at 1st day, and was most effective on End: 4th and 7th day from incubation (p<0.05). But Coecomfort, Dura conditioner, Visco-gel, Coe-soft had little antifungal effect from the 1st day of incubation. 2. Nystatin was most effective showing 9.60-12.04 mm of zone of inhibition at the 1st day from incubation. The antifungal properties were reduced to amphotericin B, chlorhexidine and materials without agent (p<0.05), and the effect was diminished by time. 3. As pretreatment with amphotericin B, nystatin, chlorhexidine, Tempo was very effective at the 1st day from incubation showing zone of inhibition as 3.65, 12.04, 4.78 mm with addition of each agent. Dura conditioner had strongest antifungal effect at the next day as 2.86, 5.33, 1.29 mm of zone of inhibition, and yielding results of Coe-comfort, Tempo, Coe-soft was shown at 4th and 7th day from incubation (p<0.05). Taken all together, tissue conditioners have little antifungal effect except Tempo. Formation of the zone of growth inhibition was due to agents amphotericin B, nystatin, chlorhexidine and nystatin was most effective. Conclusively, it is advisable to select material which is effective on the growth of C. albican and consider addition of antifungal agents for treatment of denture stomatitis.

  • PDF

Tissue conditioner in edentulous patients, depending on the time and the thickness of the changes affect the dimensional stability (무치악 환자에서 조직양화제(tissue conditioner)가 시간과 두께에 따라 체적안정성의 변화에 미치는 영향)

  • Shim, Youn-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.10
    • /
    • pp.3794-3801
    • /
    • 2010
  • This study evaluated the linear dimensional changes with the factor of time and thickness using of three commercially available tissue conditioners (Coe-Comport, Visco-Gel, Soft-Liner). The thickness of materials were changed (1.5mm, 3.0mm) and the percentage changes in dimension were measured at 1h(baseline), 12h, 24h, 3 days and 7days after specimen preparation. The obtained data were analyzed by ANOVA with the SAS/PC statistical package. From the results, large differences appear between the various tissue conditioners. The results suggested that the period recommended for forming functional impression would be 36h to 3days after insertion in the mouth. Depending on the type of tissue conditioner over time, as there were significant differences in the elastic change(p<0.05). Tissue conditioner of the 1.5mm, 3.0mm thickness were significantly different by the dimensional stability(p<0.05). Elastic deformation of the ideal itself, and resilient when compared only the look, Visco-Gel 3.0mm group, stability was the most stable volume. In addition, it is important to select tissue conditioners suitable for functional impression because of the wide range of dimensional stability among the materials.

INHIBITORY EFFECT OF ANTIFUNGAL AGENTS INCORPORATED IN DENTURE LINING MATERIALS AGAINST CANDIDA ALBICANS (의치상 이장재 표면의 캔디다 균주에 대한 항균제의 억제 효과)

  • Jang, Kyung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.3
    • /
    • pp.293-300
    • /
    • 1999
  • The purpose of this study was to evaluate the in vitro antifungal effect of several kinds of denture lining materials containing nystatin and silver-zeolite on Candida albicans. Three commercially available tissue conditioners (Soft-Liner, Coe-Comfort, Coe-Soft) and two direct denture relining materials (Tokuso Rebase, Durabase) were selected. In terms of the zone of inhibition and some basic physical properties, I could find the following results ; 1. Nystatin or silver-zeolite included in those relining materials had definite antifungal activities against the Candida albicans. 2. As times went on, both of the antifungal agents's activities decreased gradually. 3. Antifungal agents did not affect the relining materials' basic physical properties. 4 Direct chairside relining materials showed unfavorable dark discoloration with response to silver-zeolite.

  • PDF

Changes of the surface roughness depending on immersion time and powder/liquid ratio of various tissue conditioners (수종의 조직 양화재의 침수시간과 분액비에 따른 표면 거칠기의 변화)

  • Kim, Kyung-Soo;Moon, Hong-Suk;Shim, June-Sung;Jung, Moon-Kyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.108-118
    • /
    • 2009
  • Statement of problem: Volume stability, microstructure reproducibility and fluidity along with compatibility with dental stone must be in consideration in order to use tissue conditioner as a material for functional impression. There are few studies concerning the influence of time factor in oral condition on surface roughness of the stone and optimal retention period in the oral cavity considering such changes in surface roughness. Purpose: The purpose of this study was to find out the influence of various kinds of tissue conditioner, its powder/liquid ratio and immersion time on surface roughness of the stone. Material and methods: Materials used in this study were the three kinds of tissue conditioners(Coe-Comfort, Visco-Gel, Soft-Liner) and were grouped into three: group R-mixed with standard powder/liquid ratio that was recommended by the manufacturers, group M-mixed with 20% more powder, group L-mixed with 20% less powder. Specimens were made with the size of 20 mm diameter and 2 mm width. Each tissue conditioner specimens were subdivided into 5 groups according to the immersion time(0 hour, 1 day, 3 days, 5 days, 7 days), completely immersed into artificial saliva and were stored under $37^{\circ}C$. Specimens of which the given immersion time elapsed were taken out and were poured with improved stone, making the stone specimens. Surface roughness of the stone specimens was measured by a profilometer. Results: Within the limitation of this study, the following results were drawn. 1. Major influencing factor on surface roughness of the stone model made from tissue conditioner was the retention period(contribution ratio($\rho$)=62.86%, P<.05) of the tissue conditioner in oral cavity to make functional impression. 2. In case of Coe-Comfort, higher mean surface roughness value of the stone model with statistical significance was observed compared to that of Soft-Liner and Visco-Gel as immersion time changes(P<.05). 3. In case of group L(less), higher mean surface roughness value of the stone model with statistical significance was observed compared to that of R(recommended) and M(more) group as immersion time changes(P<.05). Conclusion: We may conclude that as the retention period of time in oral cavity influences surface roughness of the stone model the most and as the kind of tissue conditioner and its P/L ratio may influence also, clinician should well understand the optimal retention period in oral cavity and choose the right tissue conditioner for the functional impression, thus making the functional impression with tissue conditioner usefully.

A STUDY ON THE ADHESION OF A SOFT LINER CONTAINING 4-META TO THE BASE METAL ALLOY AND ITS VISCOELASTIC PROPERTY

  • Park Hyun-Joo;Kim Chang-Whe;Kim Yung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.6
    • /
    • pp.732-746
    • /
    • 2003
  • Statement of problem. Soft lining materials, also referred to as tissue conditioning materials, tissue heating materials, relining materials, soft liners or tissue conditioners, were first introduced to dentistry by a plastic manufacturer in 1959. Since the introduction of the materials to the dental field, their material properties have been continually improved through the effort of many researchers. Soft lining materials have become widely accepted, particularly by prosthodontists, because of their numerous clinical advantages and ease of manipulation. Unfortunately, few reports have been issued upon the topic of increasing the bond strength between the base metal alloy used in cast denture bases and PMMA soft liner modified with 4-META, nor upon the pattern of debonding and material change in wet environment like a intra oral situation. Purpose. The purposes of this study were comparing the bond strength between base metal alloy used for the cast denture bases and PMMA soft liner modified with 4-META, and describing the pattern of debonding and material property change in wet environment like the intraoral situation. Material and Methods. This study consisted of four experiments: 1. The in vitro measurement of shear bond strength of the adhesive soft liner. 2. The in vitro measurement of shear bond strength of the adhesive soft liner after 2 weeks of aging. 3. A comparison of debonding patterns. 4. An evaluation the Relation time of modified soft liner. The soft liner used in this study was commercially available as Coe-soft (GC America.IL.,USA), which is provided in forms of powder and liquid. This is a PMMA soft liner commonly used in dental clinics. The metal primer used in this study was 4-META containing primer packed in Meta fast denture base resin (Sun Medical Co., Osaka, Japan). The specimens were formed in a single lap joint desist which is useful for evaluating the apparent shear bond strength of adhesively bonded metal plate by tensile loading. Using the $20{\times}20mm$ transparent grid, percent area of adhesive soft liner remaining on the shear area was calculated to classify the debonding patterns. To evaluate the change of the initial flow of the modified adhesive soft liner, the gelation time was measured with an oscillating rheometer (Haake RS150W/ TC50, Haake Co., Germany). It was a stress control and parallel plate type with the diameter of 35mm. Conclusion. Within the conditions and limitations of this study, the following conclusions were drawn as follows. 1. There was significant increase of bond strength in the 5% 4-META, 10% 4-META containing groups and in the primer coated groups versus the control group(P<0.05). 2. After 2 weeks of aging, no significant increase in bond strength was found except for the group containing 10% 4-META (P<0.05). 3. The gelation times of the modified soft liner were 9.3 minutes for the 5% 4-META containing liner and 11.5 minutes for the 10% 4-META liner. 4. The debonding patterns of the 4-META containing group after 2 weeks of aging were similar to those of immediaely after preparation, but the debonding pattern of the primer group showed more adhesive failure after 2 weeks of aging.