• Title/Summary/Keyword: Tissue attenuation

Search Result 148, Processing Time 0.026 seconds

Rupture of Achilles Tendon after Steroid Injection in Achilles Tendinitis (A Report of Five Cases) (아킬레스 건염에서 스테로이드 주입 후 아킬레스 건 파열 (5예 보고))

  • Kim, Jeon-Gyo;Gwak, Heui-Chul;Baik, Jong-Min
    • Journal of Korean Foot and Ankle Society
    • /
    • v.17 no.4
    • /
    • pp.309-315
    • /
    • 2013
  • Purpose: The purpose of the study was to investigate five cases with chronic Achilles tendon rupture that occurred after steroid injections. Materials and Methods: In our hospital, we experienced five cases of chronic Achilles tendon rupture from September 2010 to March 2012. All patients had got steroid injection for Achilles tendinitis at the other hospitals, and their heel pain was aggravated when they visited our outpatient department. After treatment, signs and symptoms of Achilles tendon rupture were developed and the diagnosis was confirmed by ultrasonography or magnetic resonance imaging (MRI). Surgical treatment was done for Achilles tendon rupture. Results: There was difference between intra-operative findings of Achilles tendon rupture and usual chronic Achilles tendon rupture. Unlike usual findings of chronic Achilles tendon rupture whose scar tissue or tissue attenuation are found around the defect area of Achilles tendon, there were partial necrosis of tendon severe adhesion with surrounding tissue, extensive defect and longitudinal rupture on ruptured area. Also, severe inflammation of paratenon, granulation and fibrinoid deposit were found on biopsy findings in four cases. Conclusion: Based on review of data about relative risk and benefit of local corticosteroid injection to inflammatory lesion in Achilles tendon, it requires more attention to Achilles tendon rupture following local corticosteroid injection.

CT Findings of Bronchogenic Cyst (기관지 낭종의 전산화단층촬영 소견)

  • Cho, Hyun-Cheol;Lee, Yong-Woo;Hwang, Mi-Soo;Cho, Kil-Ho;Byun, Woo-Mok;Cho, Jae-Ho;Chang, Jae-Chun;Park, Bok-Hwan
    • Journal of Yeungnam Medical Science
    • /
    • v.12 no.2
    • /
    • pp.226-236
    • /
    • 1995
  • We studied to evaluate CT characteristics of bronchogenic cysts. We retrospectively evaluated CT of 11 patients with pathologically proved bronchogenic cyst. Precontrast and postcontrast CT scan was performed in all. We analyzed CT with viewpoints of location, size, attenuation on pre- and postcontrast scan, and calcification. Three of 11 bronchogenic cysts were intrapulmonary in location and eight were located in the mediastinum. Two of 3 intrapulmonary bronchogenic cysts were located in the right lower lobe, and the remaining one was left lower lobe. Intrapulmonary bronchogenic cysts ranged from 6cm to 12cm in diameter (average, 9.7 cm). On CT, intrapulmonary bronchogenic cysts appeared as thin-wall air cyst, homogenous water attenuation and soft tissue attenuation with air bubble respectively. Mediastinal bronchogenic cysts were located in posterior mediastinum(n=5), superior mediastinum(n=2), middle mediastinum(n=1) respectively. These cysts ranged in size from 3cm to 8cm in diameter (average, 5.0 cm). On CT, five showed homogenous water attenuation, two soft tissue attenuation similar to that of muscle, one air-fluid level. Calcification or contrast enhancement was not detected in any cases. On operative findings, all of intrapulmonary bronchogenic cysts contained dirty pus-like material and all of mediastinal bronchogenic cysts contained whitish or yellowish mucus material. Bronchogenic cysts showed homogenous water density in many cases, homogenous soft tissue density, air-fluid level and air-filled cyst. The constellation of CT findings may be helpful in the diagnosis and differentiation of bronchogenic cyst.

  • PDF

Evaluation of Tissue Inhomogeneity for Gamma-knife Radiosurgery Using Film Dosimetry (감마 나이프 방사선 수술시 필름 선량 측정에 의한 조직 불균일성에 대한 연구)

  • Cho, Heung-Lae;Shon, Seung-Chang;Shu, Hyun-Suk
    • Radiation Oncology Journal
    • /
    • v.16 no.3
    • /
    • pp.325-335
    • /
    • 1998
  • Purpose : Since the mid cranial fossa is composed of various thickness of bone, the tissue inhomogeneity caused by bone would produce dose attenuation in cobalt-60 gamma knife irradiation. The correction factor for bone attenuation of cobalt-60 which is used for gamma knife source is -3.5$\%$. More importantly, nearly all the radiosurgery treatment planning systems assume a treatment volume of unit density: any perturbation due to tissue inhomogeneity is neglected, This study was performed to confirm the bone attenuation in mid cranial fossa using gamma knife. Materials and Methods : Computed tomography was performed after Leksell stereotactic frame had been liked to the Alderson Rando Phantom (human phantom) skull area. Kodak X-omat V film was inserted into two sites of pituitary adenoma point and acoustic neurinoma point, and irradiated by gamma knife with 14mm and 18mm collimator. An automatic scanning densitometer with a 1mm aperture is used to measure the dose profile along the x and y axis. Results : Isodose curve constriction in mid cranial fossa is observed with various ranges. Pituitary tumor point is greater than acoustic neurinoma point (0.2-3.0 mm vs 0.1-1.3 mm) and generally 14 mm collimator is greater than 18mm collimator (0.4-3.0 mm vs. 0.2-2.2 mm) Even though the isodose constriction is found, constriction of 50$\%$ isodose curve which is used for treatment reference line does not exceed 1 mm. This range is too small to influence the treatment planning and treatment results. Conclusion : Radiosurgery planning system of gamma knife does not show significant error to be corrected without consideration of bone attenuation.

  • PDF

Ultrasonic Bone Densitometer by Measuring the Speed of Sound (SOS를 이용한 초음파 골밀도 측정 장치)

  • Jung, Min-Sang;Hahn, Eun-Joo;Kim, Yeong-Sik
    • Progress in Medical Physics
    • /
    • v.18 no.3
    • /
    • pp.172-178
    • /
    • 2007
  • An ultrasonic bone densitometer has been developed by measuring speed of sound signal transmitted and received on the skin, not through the horizontal axis but through the vertical one in tissue. The SOS(speed of sound) method measuring the time difference between the ultrasound signals reflected from the both sides of surface of bone could produce more precise result compared with the BUA(broadband ultrasound attenuation) method measuring the frequency difference. Middle finger is selected to be the best measurement position in order to increase the accuracy, after due consideration that the thickness of flesh at the down part of thumb shows too much variation although the ratio of the receiving signal is higher than the other fingers. The measured value by using SOS method shows almost the same result as compared with the conventional DEXA method.

  • PDF

Hybrid model-based and deep learning-based metal artifact reduction method in dental cone-beam computed tomography

  • Jin Hur;Yeong-Gil Shin;Ho Lee
    • Nuclear Engineering and Technology
    • /
    • v.55 no.8
    • /
    • pp.2854-2863
    • /
    • 2023
  • Objective: To present a hybrid approach that incorporates a constrained beam-hardening estimator (CBHE) and deep learning (DL)-based post-refinement for metal artifact reduction in dental cone-beam computed tomography (CBCT). Methods: Constrained beam-hardening estimator (CBHE) is derived from a polychromatic X-ray attenuation model with respect to X-ray transmission length, which calculates associated parameters numerically. Deep-learning-based post-refinement with an artifact disentanglement network (ADN) is performed to mitigate the remaining dark shading regions around a metal. Artifact disentanglement network (ADN) supports an unsupervised learning approach, in which no paired CBCT images are required. The network consists of an encoder that separates artifacts and content and a decoder for the content. Additionally, ADN with data normalization replaces metal regions with values from bone or soft tissue regions. Finally, the metal regions obtained from the CBHE are blended into reconstructed images. The proposed approach is systematically assessed using a dental phantom with two types of metal objects for qualitative and quantitative comparisons. Results: The proposed hybrid scheme provides improved image quality in areas surrounding the metal while preserving native structures. Conclusion: This study may significantly improve the detection of areas of interest in many dentomaxillofacial applications.

Tissue Mimicking Phantom for Visualization of Temperature Elevation Caused by Ultrasound (초음파에 의한 온도상승 가시화용 생체 모의매질)

  • Jung, Ji-Hee;Kim, Jung-Soon;Ha, Kang-Lyeol;Kim, Moo-Joon;Cao, Yonggang
    • The Journal of the Acoustical Society of Korea
    • /
    • v.33 no.5
    • /
    • pp.291-299
    • /
    • 2014
  • To probe the temperature elevation effect caused by ultrasound, a tissue mimicking phantom was newly suggested. A carrageenan gel was adopted to realize not only the required transparency for visualization but also acoustic characteristics similar to human tissue. To visualize the temperature elevation inside phantom, thermochromic film with a critical temperature of discoloration was introduced. Acoustic characteristics of the tissue mimicking phantom were examined when the concentrations of carrageenan and sucrose changed. As the results, the attenuation coefficient of the phantom could be controlled in the range of 0.44~0.49 dB/cm/MHz, and the acoustic impedance in the range of 1.52~1.77 Mrayls. We could control the acoustic characteristics of the phantom by different concentration of carrageenan and sucrose, and it was possible to examine the temperature elevation caused by ultrasound in the phantom. The suggested method was verified by noninvasively visualizing the temperature elevation due to planar and focused ultrasound using the fabricated phantom.

Development of Tissue mimicking ultrasound phantom materials (Tissue mimicking 초음파 팬텀물질의 개발에 관한 연구)

  • Ma, Sang-Chull;Kong, Young-Kun;Park, Ki-Jung;Lee, Suk
    • Journal of radiological science and technology
    • /
    • v.26 no.1
    • /
    • pp.51-62
    • /
    • 2003
  • We carried out studies on develop of the ultrasound tissue mimicking materials(TMM) by synthesis of polymer urethane(C, CCR, $TiO_2$, tungsten, graphite, silver type). The major finding were as follows; (1) C type TMM was shown good homogeneity, penetration, gray scale like as liver tissue and propagated speed 1,540 m/s, attenuation $0.5{\sim}0.7\;dB/cm/MHz$. (2) $TiO_2$ type TMM was shown heterogeneous dot echo pattern. (3) Silver type TMM was appear good homogeneous echo pattern like as echo texture of thyroid gland. Therefor, C type TMM will be useful for ultrasound Q/A phantom materials and previous phantom materials.

  • PDF

The Influence of Air Cavity on Interface Doses for Photon Beams (X선치료 조사야 내 공동의 존재에 따른 선량분포의 측정)

  • Chung Se Young;Kim Young Bum;Kwon Young Ho;Kim You Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.10 no.1
    • /
    • pp.69-77
    • /
    • 1998
  • When a high energy photon beam is used to treat lesions located in the upper respiratory air passages or in maxillary sinus, the beams often must traverse an air cavity before it reaches the lesion. Because of this traversal of air, it is not clear that the surface layers of the lesion forming the air-tumor tissue interface will be in a state of near electronic equilibrium; if they are not, underdosing of these layers could result. Although dose corrections at large distances beyond an air cavity are accountable by attenuation differences, perturbations at air-tissue interfaces are complex to measure or calculate. This problem has been investigated for 4MV and 10MV X-ray beams which are becoming widely available for radiotherapy with linear accelerator. Markus chamber was used for measurement with variouse air cavity geometries in X-ray beams. Underdosing effects occur at both the distal and proximal air cavity interface. The magnitude depended on geometry, energy, field sizes and distance from the air-tissue interfaces. As the cavity thickness increased, the central axis dose at the distal interface decreased. Increasing field size remedied the underdosing, as did the introduction of lateral walls. Fellowing a $20{\times}2{\times}2\;cm^3$\;air\;cavity,\;4{\times}4\;cm\;field\;there\;was\;an\;11.5\%\;and\;13\%\;underdose\;at\;the\;distal\;interface,\;while\;a\;20{\times}20{\times}2\;cm^3\;air\;cavity\;yielded\;a\;24\%\;and\;29\%$ loss for the 4MV and 10MV beams, respectively. The losses were slightly larger for the 10MV beams. The measurements reported here can be used to guide the development of new calculation models under non-equilibrium conditions. This situation is of clinical concern when lesions such as larynx and maxillary carcinoma beyond air cavities are irradiated.

  • PDF

A Case of Bronchus-Associated Lymphoid Tissue(BALT) Lymphoma in the Lung of the Patient with Primary Sj$\ddot{o}$gren's Syndrome (원발성 쇼그렌 증후군(Primary Sj$\ddot{o}$gren's Syndrome) 환자에서 발생한 Bronchus-Associated Lymphoid Tissue(BALT) 림프종 1례)

  • Kang, Min-Jong;Lee, Jae-Myung;Lee, Seung-Joon;Son, Jee-Woong;Kim, Dong-Gyu;Lee, Myung-Goo;Hyun, In-Gyu;Jung, Ki-Suck
    • Tuberculosis and Respiratory Diseases
    • /
    • v.52 no.2
    • /
    • pp.179-185
    • /
    • 2002
  • A bronchus-associated lymphoid tissue(BALT) lymphoma of the lung is a rare disorder of patients with Sj$\ddot{o}$gren's syndrome. A 49-year-old woman was admitted for an evaluation of exertional dyspnea and general weakness which had persisted for two years. The patient had suffered from dry mouth and dry eyes for five years. The physical examinations showed a coarse breath sound with inspiratory crackles on the whole lung field, particularly on the both basal lungs. The laboratory data disclosed high titers of anti-nuclear antibodies, and anti-SSA (Ro), and anti-SSB (La) antibodies. Chest radiographs demonstrated the presence of bilateral, diffuse, reticulonodular densities in both lungs. Thin-section CT scans showed diffusely distributed mosaic pattern of an inhomogeneous attenuation extending over the entire lung zone. The histological findings from an open-lung biopsy specimen revealed an accumulation of lymphoid cells around the bronchioles and an extension of malignant lymphoma cells from the bronchiolar epithelium toward the alveolar space. Immunohistochemically, the neoplastic cells reacted positively to the CD 20 antigen and were focally positive for the UCHL 1 antigen. The histological diagnosis was consistent with a low grade marginal zone B-cell lymphoma originating in the BALT. Here, we present a case of a histologically proven BALT lymphoma of the lung in a patient with primary Sj$\ddot{o}$gren's Syndrome.

The Effect of Substrate on Ecophysiological Characteristics of Green Macroalga Ulva pertusa Kjellman (Chlorophyta) (구멍갈파래(Ulva pertusa Kjellman)의 생태생리에 대한 생육기질의 효과)

  • Choi, Tae-Seob;Kim, Kwang-Young
    • ALGAE
    • /
    • v.20 no.4
    • /
    • pp.369-377
    • /
    • 2005
  • Seashore joining with land and sea, which is typical habitat for marine macroalgae, is classified two types of shore as soft- and hard-bottom shore according to topographical (geological) and ecological features. We compared two of Ulva pertusa Kjellman from two contrasting habitats, sandy (soft-bottom, Haenam) and rocky shore (hard-bottom, Hadong) in terms of chlorophyll-a fluorescence and its parameters, and various photosynthetic pigment and nutrient content in the tissue of those. Both of habitats were different in the light environment such as light attenuation coefficient and even in nutrient concentration of ambient seawater. Electron transport rate (ETR) of Ulva from sandy shore was higher than from rocky shore. The range of photosynthetic pigment content in the tissue of U. pertusa was significantly much more in from sandy shore, and also nitrogen and phosphorus content were significantly higher except for carbon content. However, there were no significant differences in the ratio of among photosynthetic pigments, and N:P ratio was similar between each other, even though significantly different. Our result implied on the reason of why most of green tides in the worldwide concentrated and frequently occurred at sites with sandy, muddy and silty bottoms, being classified as soft-bottom shore.