• Title/Summary/Keyword: Tissue attenuation

Search Result 148, Processing Time 0.021 seconds

The Fabricating and Utilizing of the Transmission Scan Tool for I-131 Whole Body Scan (I-131 전신 스캔을 위한 Transmission Scan Tool 제작과 활용)

  • Shin, Chae-Ho;Pyo, Sung-Jai;Kim, Bong-Su;Cho, Yong-Gyi;Jo, Jin-Woo;Kim, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.40-46
    • /
    • 2009
  • Purpose: A whole body scan using a radioactive iodine (I-131) for the patients with differentiated thyroid cancer is generally an useful method to detect the remnant thyroid tissue, recurred lesion or metastasis lesion after a surgery. The high dose treatment using the radioactive iodine recently tends to increase, and a hospitalization wait for the treatment has been delayed for several months. In this hospital, the treatable patients per week were increased in number through expanding a water-purifier tank and the examination time also increased as the I-131 whole body scan patients increased. Improvement for this problem, this research reduce the existing examination time and classifying the lesion's exact position intended to by fabricating and utilizing the transmission scan tool and an excellent resolution for whole body imaging. Materials and Methods: After conducting the whole body scan for patients who visited the department from February to July 2008 and received the I-131 whole body scan using the ORBITER Gamma Camera. A rail was installed in the examination table for the transmission scan for show a contour of surface area and then the transmission image was obtained and fused to the whole body scan through fabricating the tool to put a flood phantom of diluted 2 mCi $^{99m}Tc$-pertechnetate. Results: Fused image of I-131 whole body scan and the transmission scan had the excellent resolution to discriminate an oral cavity or salivary gland region, neck region's lesion, and metastasis region's position through a simple marking, and could reduce the examination time of 8~28 minutes because without the additional local image. Conclusions: In I-131 whole body scan, the transmission scan can accurately show a contour of surface area through the attenuation of radioactivity, and is useful to indicate the remnant thyroid tissue or metastasis lesion's position by improving the resolution through the fusion image with alreadyexecuted I-131 whole body scan. Also, because the additional local image is not necessary, it can reduce the time required for the examination. It will extensively apply to other clinical examinations to be helpful for identifying an anatomical position because it shows the contour of surface area.

  • PDF

Radiation Absorbed Dose Measurement after I-131 Metaiodobenzylguanidine Treatment in a patient with Pheochromycytoma (갈색세포종 환자에서 Medical Internal Radiation Dose법을 이용한 I-131 Metaiodobenzylguanidine 치료 후 흡수선량 평가)

  • Yang, Weon-Il;Kim, Byeung-Il;Lee, Jae-Sung;Lee, Jung-Rim;Choi, Chang-Woon;Lim, Sang-Moo;Hong, Sung-Woon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.4
    • /
    • pp.422-429
    • /
    • 1999
  • Purpose: The measurement of radiation absorbed dose is useful to predict the response after I-131 labeled metaiodobenzylguanidine (MIBG) therapy and determine therapy dose in patients with unresectable or malignant pheochromocytoma. We estimated the absorbed dose in tumor tissue after high dose I-131 MIBG in a patient with pheochromocytoma using a gamma camera and Medical Internal Radiation Dose (MIRD) formula. Materials and Methods: A 64-year old female patient with pheochromocytoma who had multiple metastases of mediastinum, right kidney and periaortic lymph nodes, received 74 GBq (200 mCi) of I-131 MIBG. We obtained anterior and posterior images at 0.5, 16, 24, 64 and 145 hours after treatment. Two standard sources of 37 and 74 MBq of I-131 were imaged simultaneously. Cummulated I-131 MIBG uptake in tumor tissue was calculated after the correction of background activity, attenuation, system sensitivity and count loss at a high count rate. Results: The calculated absorbed radiation dose was 32-63 Gy/ 74 GBq, which was lower than the known dose for tumor remission (150-200 Gy). follow-up studies at 1 month showed minimally reduced tumor size on computed tomography, and mildly reduced I-131 MIBG uptake. Conclusion: We estimated radiation absorbed dose after therapeutic I-131 MIBG using a gamma camera and MIRD formula, which can be peformed in a clinical nuclear medicine laboratory. Our results suggest that the measurement of radiation absorbed dose in I-131 MIBG therapy is feasible as a routine clinical practice that can guide further treatment plan. The accuracy of dose measurement and correlation with clinical outcome should be evaluated further.

  • PDF

Ischemic Preconditioning and Its Relation to Glycogen Depletion (허혈성 전처치와 당원 결핍과의 관계)

  • 장대영;김대중;원경준;조대윤;손동섭;양기민;라봉진;김호덕
    • Journal of Chest Surgery
    • /
    • v.33 no.7
    • /
    • pp.531-540
    • /
    • 2000
  • Baclgrpimd; Recent studies have suggested that the cardioprotective effect of ischemic preconditioning(IP) is closely related to glycogen depletion and attenuation of intracellular acidosis. In the present study, the authors tested this hypothesis by perfusion isolated rabbit hearts with glucose(G) is closely related to glycogen depletion and attenuation of intracellular acidosis. In the present study, the authors tested this hypothesis by perfusion isolated rabbit hearts with glucose(G)-free perfusate. Material and Method; Hearts isolated from New Zealand white rabbits(1.5~2.0 kg body weight) were perfused with Tyrode solution by Langendorff technique. After stabilization of baseline hemodynamics, the hearts were subjected to 45 min global ischemia followed by 120 min reperfusion with IP(IP group, n=13) or without IP(ischemic control group, n=10). IP was induced by single episode of 5 min global ischemia and 10 min reperfusion. In the G-free preconditioned group(n=12), G depletion was induced by perfusionwith G-free Tyrode solution for 5 min and then perfused with G-containing Tyrode solution for 10 min; and 45 min ischemia and 120 min reperfusion. Left ventricular functionincluding developed pressure(LVDP), dP/dt, heart rate, left ventricular end-distolic pressure(LVEDP) and coronary flow (CF) were measured. Myocardial cytosolic and membrane PKC activities were measured by 32P-${\gamma}$-ATP incorporation into PKC-specific peptide and PKC isozymes were analyzed by Western blot with monoclonal antibodies. Infarct size was determined by staining with TTC(tetrazolium salt) and planimetry. Data were analyzed by one-way analysis of variance (ANOVA) and Turkey's post-hoc test. Result ; In comparison with the ischemic control group, IP significantly enhanced functional recovery of the left ventricle; in contrast, functional significantly enhanced functional recovery of the left ventricle; in contrast, functional recovery were not significantly different between the G-free preconditioned and the ischemic control groups. However, the infarct size was significantly reduced by IP or G-free preconditioning(39$\pm$2.7% in the ischemic control, 19$\pm$1.2% in the IP, and 15$\pm$3.9% in the G-free preconditioned, p<0.05). Membrane PKC activities were increased significantly after IP (119%), IP and 45 min ischemia(145%), G-free [recpmdotopmomg (150%), and G-free preconditioning and 45 min ischemia(127%); expression of membrane PKC isozymes, $\alpha$ and $\varepsilon$, tended to be increased after IP or G-free preconditioning. Conclusion; These results suggest that in isolated Langendorff-perfused rabbit heart model, G-free preconditioning (induced by single episode of 5 min G depletion and 10 min repletion) colud not improve post-ischemic contractile dysfunction(after 45-minute global ischemia); however, it has an infarct size-limiting effect.

  • PDF

Effect of Inhaled Nitric Oxide on Hemodynamics, Gas Exchange and Pulmonary Inflammation in Newborn Piglets with Escherichia coli Induced Septic Lungs (패혈성 폐가 유도된 신생자돈에서 외인성 Nitric Oxide 흡입의 혈역학, 가스교환 및 폐 염증에 대한 효과)

  • Chang, Yun Sil;Ko, Sun Young;Park, Won Soon
    • Clinical and Experimental Pediatrics
    • /
    • v.46 no.8
    • /
    • pp.777-783
    • /
    • 2003
  • Purpose : The aim of this study was to evaluate the effect of inhaled nitric oxide(iNO) on gas exchange, hemodynamics and pulmonary inflammation in newborn piglets with E. coli induced septic lung. Methods : Twenty three instrumented and ventilated piglets were randomized into three groups : CON(n=6), PCON(n=9), and PNO(n=8). In the piglets of the PCON and PNO groups, E. coli septic lung was induced by endotracheal instillation of E. coli. Ten ppm iNO was given continuously in the PNO group after endotracheal instillation of E. coli. All animals were mechanically ventilated for six hour with a peak inspiratory pressure of 30 $cmH_2O$, frequency of 25 breaths/min, $FiO_2$ 1.0 and a positive end-expiratory pressure of 4 $cmH_2O$. All measurements were made at one hour intervals during the experiment. At the end of the experiment, lung tissue was harvested for the analysis of myeloperoxidase activity, indicative of lung inflammation. Results : All piglets with pulmonary instillation of E. coli developed E. coli sepsis. Piglets in the PCON group developed progresseve pulmonry hypertension, hypoxemia and hypercarbia compared to the CON group due to increased pulmonary vascular resistance, intrapulmonary shunt fraction and physiologic dead space fraction. iNO did not reverse pulmonary hypertension in the PNO group. However iNO significantly improved oxygenation, which was attributed to marked improvement of venous admixture and partial attenuation of increase in dead space fraction. Increased myeloperoxidase activity in PCON compared to CON was significantly attenuated in PNO. Conclusion : iNO improves oxygenation and lung inflammation in newborn piglets with E. coli induced septic lung.

The Study of New Reconstruction Method for Brain SPECT on Dual Detector System (Dual detector system에서 Brain SPECT의 new reconstruction method의 연구)

  • Lee, Hyung-Jin;Kim, Su-Mi;Lee, Hong-Jae;Kim, Jin-Eui;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.57-62
    • /
    • 2009
  • Purpose: Brain SPECT study is more sensitive to motion than other studies. Especially, when applying 1-day subtraction method for Diamox SPECT, it needs shorter study time in order to prevent reexamination. We were required to have new study condition and analysing method on dual detector system because triple head camera in Seoul National University Hospital is to be disposed. So we have tried to increase image quality and make the dual and triple head to have equivalent study time by using a new analysing program. Materials and Methods: Using IEC phantom, we estimated contrast, SNR and FWHM. In Hoffman 3D brain phantom which is similar with real brain, we were on the supposition that 5% of injected doses were distributed in brain tissue. To compare with existing FBP method, we used fan-beam collimator. And we applied 15 sec, 25 sec/frame for each SEPCT studies using LEHR and LEUHR. We used OSEM2D and Onco-flash3D reconstruction method and compared reconstruction methods between applied Gaussian post-filtering 5mm and not applied as well. Attenuation correction was applied by manual method. And we did Brain SPECT to patient injected 15 mCi of $^{99m}Tc$-HMPAO according to results of Phantom study. Lastly, technologist, MD, PhD estimated the results. Results: The study shows that reconstruction method by Flash3D is better than exiting FBP and OSEM2D when studied using IEC phantom. Flowing by estimation, when using Flash3D, both of 15 sec and 25 sec are needed postfiltering 5 mm. And 8 times are proper for subset 8 iteration in Flash3D. OSEM2D needs post-filtering. And it is proper that subset 4, iteration 8 times for 15sec and subset 8, iteration 12 times for 25sec. The study regarding to injected doses for a patient and study time, combination of input parameter-15 sec/frame, LEHR collimator, analysing program-Flash3D, subset 8, iteration 8times and Gaussian post-filtering 5mm is the most appropriate. On the other hands, it was not appropriate to apply LEUHR collimator to 1-day subtraction method of Diamox study because of lower sensitivity. Conclusions: We could prove that there was also an advantage of short study time effectiveness in Dual camera same as Triple gamma camera and get great result of alternation from existing fan-beam collimator to parallel collimator. In addition, resolution and contrast of new method was better than FBP method. And it could improve sensitivity and accuracy of image because lesser subjectivity was input than Metz filter of FBP. We expect better image quality and shorter study time of Brain SPECT on Dual detector system.

  • PDF

The Effect of Matrix Metalloproteinase Inhibitor for Left Ventricular Remodeling after Myocardial Infarction in a Rabbit Model (토끼에서 Myocardial Infarction 후 Left Ventricular Remodeling에 대한 Matrix Metalloproteinase의 차단 효과)

  • Kim, Soo-Hyun;Jung, Tae-Eun;Hong, Geu-Ru;Han, Sung-Sae
    • Journal of Chest Surgery
    • /
    • v.40 no.5 s.274
    • /
    • pp.329-340
    • /
    • 2007
  • Background: Matrix Metalloproteinase (MMP) inhibition has emerged as a potential therapeutic strategy for the left ventricular dilatation that occurs after myocardial infarction. This study is designed to evaluate which treatment is better for attenuating the left ventricular remodeling via MMP inhibition 1) during the early, short highly MMP producing period of the initial phase or 2) during most of the period of the initial phase after myocardial infarction. Material and Method: Myocardial infarction was induced by ligation of the left anterior descending coronary artery in rabbits. The experimental group was divided into 3 groups. The myocardial infarction only (MI only) group consisted of 7 cases. The MMP inhibitor administered for 5 days after MI (MMPI 50) group had 6 cases, and these rabbits were given MMP inhibitor for 5 days after myocardial infarction, beginning with the postoperative first day. MMP inhibitor administered for 9 days (MMPI 90) group consisted of 5 cases and these rabbits were given MMPI for 9 days the same manner as above. CG2300 was used as a selective MMPI; this is a potent MMP-2 and -9 inhibitor Two-D echocardiograms were performed on all the groups at the time of preoperative period, the post-operative 1st week, the postoperative 20 week and the postoperative 30 week, and we measured the end-diastolic dimension (EDD), the end-systolic dimension (ESD), and the ejection fraction (EF). Result: The echocardiograms generally showed postoperative left ventricular dilatation in the MI only group. The EDD was increased significantly higher in the postoperative 1 week compared to the preoperative value (p<0.05). The ESD was also increased significantly higher in the postoperative 1st week, the postoperative 20 week and the postoperative 30 week compared to the preoperative value (p<0.05). Left ventricular dilatation was noted to be less In the MMPI 9d group than in the MI only and MMPI 5d groups. In the MMPI 9d group, there was no significant change of EF postoperatively compared to the preoperative period. MMP-2 and MMP-9 were measured from the infarcted myocardial tissue at post-MI 4 weeks by performing western blotting and zymography. The changes the of protein expression and activity of MMP-2 and MMP-9 were not significant in the three MI groups and the normal heart group. Histopathologic examination revealed severe collagen deposition in the MI only group. Collagen accumulation was reduced in both the MMPI groups. The MMPI 9d group revealed an increased number of capillaries. Conclusion: Left ventricular dilatation developed rapidly after, MI from ligation of the coronary artery and MMPI attenuated the ventricular dilatation. The effect of MMPI seemed to have better a result from its usage during most of the period of the initial phase after myocardial infarction. This suggested that increased neovascularization by MMPI may also contribute to attenuation of the left ventricular remodeling.

Clinical and Radiological Characteristics of Non-Tuberculous Bronchial Anthracofibrosis (비결핵성 기관지탄분섬유증의 임상적 특징과 방사선학적 특징)

  • Jang, See Jin;Lee, Sook Young;Kim, Suk Chan;Lee, So Young;Cho, Hyun Sun;Park, Ki Hoon;Moon, Hwa Sik;Song, Jeong Sup;Park, Sung Hak;Kim, Young Kyoon;Park, Hyun Jin
    • Tuberculosis and Respiratory Diseases
    • /
    • v.63 no.2
    • /
    • pp.139-144
    • /
    • 2007
  • Background: Bronchial anthracofibrosis, which is defined as bronchial narrowing with black pigmentation of the overlying bronchial mucosa, is frequently associated with tuberculosis. The aim of this study was to examine the relationship between bronchial anthrocofibrosis and to identify the clinical and radiological characteristics of non-tuberculous bronchial anthracofibrosis. Methods: All patients who showed bronchial anthracofibrosis in more than one segment on a bronchoscopic examination from January 2003 to July 2006 at Kangnam St. Mary's hospital were enrolled in this study. The underlying diseases, baseline clinical characteristics, characteristic findings on a computed tomogram (CT) of the chest, pathologic findings of the bronchial mucosa, and the clinical response to steroid therapy were analyzed retrospectively. Results: A total 54 patients (19 males, 35 females) were enrolled with a mean age of 75 years. The most common presenting symptoms were cough, sputum and dyspnea. The predominant X-ray findings were peribronchial soft tissue attenuation with or without calcification, mediastinal lymphadenopathy with or without calcification and atelectasis. Fourteen non-tuberculous anthracofibrosis patients were treated with steroid. Nine patients were improved clinically, and 6 patients were improved radiologically. Conclusion: Bronchial anthracofibrosis is frequently associated with various pulmonary diseases not only tuberculosis but also COPD pneumonia etc.

A Study of a Non-commercial 3D Planning System, Plunc for Clinical Applicability (비 상업용 3차원 치료계획시스템인 Plunc의 임상적용 가능성에 대한 연구)

  • Cho, Byung-Chul;Oh, Do-Hoon;Bae, Hoon-Sik
    • Radiation Oncology Journal
    • /
    • v.16 no.1
    • /
    • pp.71-79
    • /
    • 1998
  • Purpose : The objective of this study is to introduce our installation of a non-commercial 3D Planning system, Plunc and confirm it's clinical applicability in various treatment situations. Materials and Methods : We obtained source codes of Plunc, offered by University of North Carolina and installed them on a Pentium Pro 200MHz (128MB RAM, Millenium VGA) with Linux operating system. To examine accuracy of dose distributions calculated by Plunc, we input beam data of 6MV Photon of our linear accelerator(Siemens MXE 6740) including tissue-maximum ratio, scatter-maximum ratio, attenuation coefficients and shapes of wedge filters. After then, we compared values of dose distributions(Percent depth dose; PDD, dose profiles with and without wedge filters, oblique incident beam, and dose distributions under air-gap) calculated by Plunc with measured values. Results : Plunc operated in almost real time except spending about 10 seconds in full volume dose distribution and dose-volume histogram(DVH) on the PC described above. As compared with measurements for irradiations of 90-cm 550 and 10-cm depth isocenter, the PDD curves calculated by Plunc did not exceed $1\%$ of inaccuracies except buildup region. For dose profiles with and without wedge filter, the calculated ones are accurate within $2\%$ except low-dose region outside irradiations where Plunc showed $5\%$ of dose reduction. For the oblique incident beam, it showed a good agreement except low dose region below $30\%$ of isocenter dose. In the case of dose distribution under air-gap, there was $5\%$ errors of the central-axis dose. Conclusion : By comparing photon dose calculations using the Plunc with measurements, we confirmed that Plunc showed acceptable accuracies about $2-5\%$ in typical treatment situations which was comparable to commercial planning systems using correction-based a1gorithms. Plunc does not have a function for electron beam planning up to the present. However, it is possible to implement electron dose calculation modules or more accurate photon dose calculation into the Plunc system. Plunc is shown to be useful to clear many limitations of 2D planning systems in clinics where a commercial 3D planning system is not available.

  • PDF