• Title/Summary/Keyword: Timer accuracy

Search Result 27, Processing Time 0.022 seconds

Modelling of Differentiated Bandwidth Requests in IEEE 802.16m Systems

  • Yoon, Kang Jin;Kim, Ronny Yongho;Kim, Young Yong
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.7 no.4
    • /
    • pp.726-747
    • /
    • 2013
  • In order to support a large number of mobile stations (MSs) with statistical multiplexing in cellular networks, a random access scheme is widely used for uplink (UL) bandwidth request (BR). In the design of a random access based BR scheme, there are two important requirements: short connection delay and diverse Quality of Services (QoSs) support. Such requirements are crucial for IMT-Advanced systems like IEEE 802.16m to provide various types of fourth generation (4G) data services. IEEE 802.16m provides advanced UL BR schemes for non-real time polling service (nrtPS) and best-effort (BE) service to meet the requirements of short connection time and multiple QoS level support. In order to provide short connection time and multiple QoS support, three-step and differentiated BR procedures are adopted. In this paper, a novel modelling of IEEE 802.16m contention based BR scheme is proposed that uses a 2-dimensional discrete time Markov chain. Both the short access delay three-step BR procedures and normal five-step BR procedure are considered in the model. Our proposed model also incorporates the IEEE 802.16m differentiated BR procedure. With the proposed model, we extensively evaluate the performance of IEEE 802.16m BR for two different service classes by changing QoS parameters, such as backoff window size and BR timer. Computer simulations are performed to corroborate the accuracy of the proposed model for various operation scenarios. With the proposed model, accurate QoS parameter values can be derived for the IEEE 802.16m contention-based BR scheme.

Study on the Optoelectronic Design for Korean Mobile Satellite Laser Ranging System

  • Lim, Hyung-Chul;Bang, Seong-Cheol;Yu, Sung-Yeol;Seo, Yoon-Kyung;Park, Eun-Seo;Kim, Kwang-Dong;Nah, Ja-Kyoung;Jang, Jeong-Gyun;Jang, Bi-Ho;Park, Jang-Hyun;Park, Jong-Uk
    • Journal of Astronomy and Space Sciences
    • /
    • v.28 no.2
    • /
    • pp.155-162
    • /
    • 2011
  • Korea Astronomy and Space Science Institute has been developing one mobile and one stationary satellite laser ranging system for the space geodesy research and precise orbit determination since 2008, which are called as ARGO-M and ARGO-F, respectively. They will be capable of daytime laser ranging as well as nighttime and provide the accurate range measurements with millimeter level precision. Laser ranging accuracy is mostly dependent on the optics and optoelectronic system which consists of event timer, optoelectronic controller and photon detectors in the case of ARGO-M. In this study, the optoelectronic system of ARGO-M is addressed and its critical design is also presented. Additionally, the experiment of the integrated optoelectronic system was performed in the laboratory to validate the functional operation of each component and its results are analyzed to investigate ARGO-M performance in advance.

Power consumption estimation of active RFID system using simulation (시뮬레이션을 이용한 능동형 RFID 시스템의 소비 전력 예측)

  • Lee, Moon-Hyoung;Lee, Hyun-Kyo;Lim, Kyoung-Hee;Lee, Kang-Won
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.8
    • /
    • pp.1569-1580
    • /
    • 2016
  • For the 2.4 GHz active RFID to be successful in the market, one of the requirements is the increased battery life. However, currently we do not have any accurate power consumption estimation method. In this study we develop a simulation model, which can be used to estimate power consumption of tag accurately. Six different simulation models are proposed depending on collision algorithm and query command method. To improve estimation accuracy, we classify tag operating modes as the wake-up receive, UHF receive, sleep timer, tag response, and sleep modes. Power consumption and operating time are identified according to the tag operating mode. Query command for simplifying collection and ack command procedure and newly developed collision control algorithm are used in the simulation. Other performance measures such as throughput, recognition time for multi-tags, tag recognition rate including power consumption are compared with those from the current standard ISO/IEC 18000-7.

A Study on Developing Safety and Performance Assessment Guideline for Electronic Warm-Acupuncture Apparatus (전기식 온침기에 대한 안전성 및 성능평가 가이드라인 개발 연구)

  • Hansol Jang;U-Ryeong Chung;Jeong-Hyun Moon;Seong-Kyeong Choi;Won-Suk Sung;Min-Seop Hwang;Seung-Deok Lee;Kyung-Ho Kim;Jong-Hwa Yoon;Eun-Jung Kim
    • The Journal of Korean Medicine
    • /
    • v.43 no.3
    • /
    • pp.150-163
    • /
    • 2022
  • Objectives: This research aimed to develop a guideline for evaluating safety and performance of electronic warm-acupuncture apparatus. With the development of medical devices like electronic warm-acupuncture apparatus with improved performance, convenience and safety measures compared to traditional warm-acupuncture needling, safety and performance guideline is a necessity. Methods: By referring to existing standards and guidelines of other electronic devices for Korean medicine with heating function, guideline for safety and performance assessment of electronic warm-acupuncture apparatus was drafted Results: The guideline, presents explanation for adequate temperature and settings of the apparatus, and safety measurements providing against thermal runaway situations along with guidelines for the manual. Guideline for detailed test method for the performance of the apparatus such as accuracy of temperature increase and the timer, and safety unit was also provided. The test items and suggested test methods for the requirements of biological, electrical and electromagnetic safety were referred to Korean approval documents of ministry of Food and Drug Safety. Conclusion: We proposed the relevant items to verify performance and safety of warm-acupuncture apparatus to assure patient safety and improve the quality of currently developing devices for application in clinical field.

A Study on Ocean Meteorological Observation Wave Meter System based on Kalman-Filter (칼만 필터 기반의 스마트 해양기상관측 파고 시스템 연구)

  • Park, Sanghyun;Park, Yongpal;Kim, Heejin;Kim, Jinsul;Park, Jongsu
    • Journal of Digital Contents Society
    • /
    • v.18 no.7
    • /
    • pp.1377-1386
    • /
    • 2017
  • We propose a smart ocean meteorological observation system which is capable of real-time measurement of vulnerable marine climate and oceanographic conditions. Besides, imported products have several disadvantages such that they can't be measured for a long time and can't transmit data in real time. In the proposed system, smart ocean observation digging system, it observes real-time ocean weather with data logger methods. Furthermore, we also use existing dataloggers functions with various sensors which are available in the ocean at the same time. Also, we applied the Kalman-filter algorithm to the ocean crest measurement to reduce the noise and increase the accuracy of the real-time wave height measurement. In the experiment, we experimented the proposed system with our proposed algorithms through calibration devices in the real ocean environment. Then we compared the proposed system with and without the algorithms. As a result, the system developed with a lithium iron phosphate battery that can be charged by a system used in the ocean and minimized power consumption by using an RTC based timer for optimal use. Besides, we obtained optimal battery usage and measured values through experiments based on the measurement cycle.

Display of Irradiation Location of Ultrasonic Beauty Device Using AR Scheme (증강현실 기법을 이용한 초음파 미용기의 조사 위치 표시)

  • Kang, Moon-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.9
    • /
    • pp.25-31
    • /
    • 2020
  • In this study, for the safe use of a portable ultrasonic skin-beauty device, an android app was developed to show the irradiation locations of focused ultrasound to a user through augmented reality (AR) and enable stable self-surgery. The utility of the app was assessed through testing. While the user is making a facial treatment with the beauty device, the user's face and the ultrasonic irradiation location on the face are detected in real-time with a smart-phone camera. The irradiation location is then indicated on the face image and shown to the user so that excessive ultrasound is not irradiated to the same area during treatment. To this end, ML-Kit is used to detect the user's face landmarks in real-time, and they are compared with a reference face model to estimate the pose of the face, such as rotation and movement. After mounting a LED on the ultrasonic irradiation part of the device and operating the LED during irradiation, the LED light was searched to find the position of the ultrasonic irradiation on the smart-phone screen, and the irradiation position was registered and displayed on the face image based on the estimated face pose. Each task performed in the app was implemented through the thread and the timer, and all tasks were executed within 75 ms. The test results showed that the time taken to register and display 120 ultrasound irradiation positions was less than 25ms, and the display accuracy was within 20mm when the face did not rotate significantly.

erratum : A Study on Developing Safety and Performance Assessment Guideline for Electronic Warm-Acupuncture Apparatus (erratum : 전기식 온침기에 대한 안전성 및 성능평가 가이드라인 개발 연구)

  • Hansol Jang;U-Ryeong Chung;Jeong-Hyun Moon;Seong-Kyeong Choi;Won-Suk Sung;Min-Seop Hwang;Seung-Deok Lee;Kyung-Ho Kim;Jong-Hwa Yoon;Eun-Jung Kim
    • The Journal of Korean Medicine
    • /
    • v.44 no.1
    • /
    • pp.128-128
    • /
    • 2023
  • Objectives: This research aimed to develop a guideline for evaluating safety and performance of electronic warm-acupuncture apparatus. With the development of medical devices like electronic warm-acupuncture apparatus with improved performance, convenience and safety measures compared to traditional warm-acupuncture needling, safety and performance guideline is a necessity. Methods: By referring to existing standards and guidelines of other electronic devices for Korean medicine with heating function, guideline for safety and performance assessment of electronic warm-acupuncture apparatus was drafted Results: The guideline, presents explanation for adequate temperature and settings of the apparatus, and safety measurements providing against thermal runaway situations along with guidelines for the manual. Guideline for detailed test method for the performance of the apparatus such as accuracy of temperature increase and the timer, and safety unit was also provided. The test items and suggested test methods for the requirements of biological, electrical and electromagnetic safety were referred to Korean approval documents of ministry of Food and Drug Safety. Conclusion: We proposed the relevant items to verify performance and safety of warm-acupuncture apparatus to assure patient safety and improve the quality of currently developing devices for application in clinical field.