• Title/Summary/Keyword: Time-varying magnetic environment

Search Result 4, Processing Time 0.023 seconds

Magnetic Disturbance Model-Embedded Heading Estimation Filter for Time-Varying Magnetic Environments (시변 자기 환경에 강한 자기왜곡 모델 내장형 헤딩 추정 필터)

  • Lee, Jung Keun;Choi, Mi Jin
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.4
    • /
    • pp.286-291
    • /
    • 2017
  • With regards to heading estimation using gyroscope and magnetometer signals, magnetic disturbance added in the magnetometer signals is a main degradation factor in the estimation accuracy. Although there are a number of existing mechanisms that may properly compensate for the magnetic disturbances, they are designed to react only to the magnetic disturbances, but not to the time derivative of disturbances. Note that the sensors may experience abrupt changes in the magnetic disturbances, particularly for ambulatory applications. This paper proposes a magnetic disturbance model-embedded heading estimation filter for time-varying magnetic environments. The proposed magnetic disturbance model is based on a first-order Markov chain with a conditional switching technique depending on the time derivative of disturbances. Once a high amount of derivative is detected, the corrupted magnetometer signals are discarded to protect the filter from them. In our experimental results, the averaged heading error of tests was $1.46^{\circ}$, while that of the original approach without switching was $5.75^{\circ}$.

A Study of Characteristic of Electrical-magnetic and Neutron Diffraction of Long-wire High-superconductor for Reducing Energy Losses

  • Jang, Mi-Hye
    • Transactions on Electrical and Electronic Materials
    • /
    • v.9 no.6
    • /
    • pp.265-272
    • /
    • 2008
  • In this paper, AC losses of long wire Bi-2223 tapes with different twist pitch of superconducting core were fabricated, measured and analyzed. These samples produced by a powder-in-tube method are multi-filamentary tape with Ag matrix. Also, it's produced by non-twist. The critical current measurement was carried out under the environment in Liquid nitrogen and in zero field by 4-prob method. And the Magnetic measurement was carried out under the environment of applied time-varying transport current by transport method. From experiment, the susceptibility measurements were conducted while cooling in a magnetic field. Flux loss measurements were conducted as a function of ramping rate, frequency and field direction. The AC flux loss increases as the twist-pitch of the tapes decreased, in agreement with the Norris Equation. Neutron-diffraction measurements have been carried out investigate the crystal structure, magnetic structures, and magnetic phase transitions in Bi-2223([Bi, Pb]:Sr:Ca:Cu:O).

Research of operators and patients exposed to electromagnetic field in the hospital (병원에서의 환자, 의료진의 전자파 노출 실태 조사)

  • Ji, Hyo-Chul;Hong, Hyun-Ki;Kim, Sung-Woo;Lee, Ju-Hyung;Kim, Deok-Won
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.70-72
    • /
    • 2007
  • In this study, electromagnetic fields emitted from the various environment in the hospital were measured. Measurement spot was patients' head. To monitor how much magnetic fields are emitting from operation room, monitoring device was attached to 19 anesthesiologist and monitoring lasted 8 hours. We also took a measurement from various medical devices. Devices include ESWL, PET, MRI, CT, Gamma knife, X-ray, Angiogram, Echocardiogram, Upper GI and Linear Accelerator. Electromagnetic fields were measured from 10 spots from each of 5 patient waiting room. As a results, there were no places showing risk of high exposure. All the measurement values were below the reference levels for general public exposure to time varying electric and magnetic fields which is issued by ICNIRP.

  • PDF

Head Motion Detection and Alarm System during MRI scanning (MRI 영상획득 중의 피험자 움직임 감지 및 알림 시스템)

  • Pae, Chong-Won;Park, Hae-Jeong;Kim, Dae-Jin
    • Investigative Magnetic Resonance Imaging
    • /
    • v.16 no.1
    • /
    • pp.55-66
    • /
    • 2012
  • Purpose : During brain MRI scanning, subject's head motion can adversely affect MRI images. To minimize MR image distortion by head movement, we developed an optical tracking system to detect the 3-D movement of subjects. Materials and Methods: The system consisted of 2 CCD cameras, two infrared illuminators, reflective sphere-type markers, and frame grabber with desktop PC. Using calibration which is the procedure to calculate intrinsic/extrinsic parameters of each camera and triangulation, the system was desiged to detect 3-D coordinates of subject's head movement. We evaluated the accuracy of 3-D position of reflective markers on both test board and the real MRI scans. Results: The stereo system computed the 3-D position of markers accurately for the test board and for the subject with glasses with attached optical reflective marker, required to make regular head motion during MRI scanning. This head motion tracking didn't affect the resulting MR images even in the environment varying magnetic gradient and several RF pulses. Conclusion: This system has an advantage to detect subject's head motion in real-time. Using the developed system, MRI operator is able to determine whether he/she should stop or intervene in MRI acquisition to prevent more image distortions.