• Title/Summary/Keyword: Time-to-treatment

Search Result 15,210, Processing Time 0.048 seconds

Early Results of Maze III Operation Without Cryoablation (냉동절제 없이 시행한 Maze III 술식의 조기 결과)

  • 김형수;이원용;오동진;지현근;홍기우;두영철
    • Journal of Chest Surgery
    • /
    • v.32 no.3
    • /
    • pp.255-261
    • /
    • 1999
  • Background: Atrial fibrillation is one of the most prevalent of all arrhythmias and in up to 79% of the patients with mitral valve disease. This study examined whether the atrial fibrillation that occur in patients with mitral valve operation could be eliminated by a concommitant maze operation without cryoablation. Material and Method: From May 1997 to April 1998, 14 patients with atrial fibrillation associated with mitral valve disease underwent Maze III operation without cryoablation. Preoperatively there were 6 men and 8 women with an average age of 46.2${\pm}$10.7 years. Eleven patients had mitral stenosis, and three had mitral insufficiency. The associated heart diseases were aortic valve disease in 4, tricuspid valve regurgitation in 1 and ASD in 2. Using transthoracic echocardiography, the mean left atrial diameters was 54.7${\pm}$5.3 mm and thrombi were found in the left atrium of 2 patients. Postoperatively the ratio between the peak speed of the early filling wave and that of the atrial contraction wave (A/E ratio) was determined from transmitral flow measurement. Operations were mitral valve replacement in 13 including 4 aortic valve replacements, 1 DeVega annuloplasty and 2 ASD closures. Maze III operation was performed in 1 patient. Result: Five patients (38%) had recurred atrial fibrillation, which was reversed with flecainide or amiodarone at the average time of postoperative 38.8${\pm}$23.5 days. Postoperative complications were postoperative transient junctional rhythm in 6, transient atrial fibrillation in 5, reoperation for bleeding in 3, postpericardiotomy syndrome(1), unilateral vocal cord palsy(1), postoperative psychosis(1), and myocardial infarction(1). Postoperatively A/E ratio was 0.43${\pm}$0.22 and A wave found in 9(64%) patients. 3 to 14 months postoperatively (average follow- up, 8.1 months), all of patients had normal sinus rhythm and 9(64%) patients had left atrial contraction and 11(79%) patients were not on a regimen of antiarrhythmic medication. Conclusion: We conclude that Maze III operation without cryoablation is an effective surgical treatment in atrial fibrillation associated with the mitral valve disease.

  • PDF

Phenolic Contents of Different Parts of Rhus verniciflua Stokes according to Extraction Conditions (추출조건에 따른 옻나무 부위별 Phenolics 함량)

  • Park, Hye Jin;Lee, Sang Hoon;Jang, Gwi Yeong;Li, Meishan;Kim, Min Young;Kim, Sung Tae;Lee, Ji Hyun;Yoon, Gun Mook;Lee, Junsoo;Jeong, Heon Sang
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.44 no.1
    • /
    • pp.97-103
    • /
    • 2015
  • This study investigated changes in phenolic contents of different parts of Rhus verniciflua Stokes (RV) according to extraction conditions. Bark and xylem parts of RV were extracted at 80, 100, 120, 140, and $160^{\circ}C$ for 1, 3, and 5 h, respectively. Major phenolic compounds (gallic acid, protocatechuic acid, fustin, fisetin, sulfuretin, and butein) of RV were analyzed. The gallic acid, fisetin, sulfuretin, and butein contents significantly increased as extraction temperature increased. Protocatechuic acid and fustin contents increased as increasing extraction temperature to $120^{\circ}C$ and decreased afterward. The gallic acid, protocatechuic acid, and butein contents of bark were higher than those of xylem extracts. The optimal extraction conditions of gallic acid, protocatechuic acid, fustin, fisetin, sulfuretin, and butein were $160^{\circ}C/3h$ (380.22 mg%), $120^{\circ}C/1h$ (9.25 mg%), $100^{\circ}C/3h$ (206.97 mg%), $140^{\circ}C/5h$ (93.84 mg%), $140^{\circ}C/5h$ (16.07 mg%) and $160^{\circ}C/5h$ (1.49 mg%), respectively. These results suggest that the optimum extraction temperature and time considering RV extraction yield and cost are $140^{\circ}C$ and 3 h, respectively.

Analysis of Quality and Processing Suitability of Mixed Seeding and Flour Blending between Wheat Varieties (밀 품종 혼파와 밀가루 혼합에 따른 품질 및 가공적성 분석)

  • Kim, Kyeong-Min;Kim, Kyeong-Hoon;Kang, Chon-Sick;Jeong, Han young;Choi, Chang-Hyun;Park, Jinhee;Son, Jae-Han;Yang, Jinwoo;Kim, Young-Jin;Park, Tae-Il;Kweon, Meera
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.64 no.3
    • /
    • pp.225-233
    • /
    • 2019
  • This study was conduct to investigate the effect of mixed seed sowing and flour blending on the uniformity of flour quality of Korean domestic wheat. Two wheat varieties (Keumkang and Baegjoong) were selected for sowing mixed seeds, and their growth characteristics and flour quality were analyzed. Quality of flour blending with the same varieties was also evaluated. The ratios for mixed seed sowing and flour blending were from 0 to 100% with a 10% increase of interval for each treatment. On increasing the portion of Baegjoong in mixed seed sowing, the heading time was a little delayed, however, yield increased. The results of the flour quality showed lower damaged starch content and sodium carbonate SRC (solvent retention capacity) value for Keumkang than for Baegjoong. Protein quantity by protein content and quality by SDSS (Sodium Dodecyle Sulfate-Sedimentation) volume, lactic acid SRC, and mixograph pattern of Keumkang were superior to those of Baegjoong. Compared with mixed seed sowing, overall quality characteristics of flours with different ratios showed predictable and proportional change by flour blending. This demonstrated the successful application of flour blending, compared with mixed seed sowing, for improving the uniformity of flour quality.

Proteome analysis of storage roots of two sweet potato cultivars with contrasting low temperature tolerance during storage (저온 저장 감수성 및 저항성 고구마 품종에서 저온 반응성 단백질체 연구)

  • Kim, Yun-Hee;Ji, Chang Yoon;Kim, Ho Soo;Chung, Jung-Sung;Choi, Sung Hwan;Kwak, Sang-Soo;Lee, Jeung Joo
    • Journal of Plant Biotechnology
    • /
    • v.49 no.2
    • /
    • pp.118-123
    • /
    • 2022
  • To obtain information on the molecular mechanism underlying the low temperature tolerance of sweet potato [Ipomoea batatas (L.) Lam], the proteome expressed in the sweet potato cultivar Xushu 15-1 with high cold storage tolerance and in the cultivar Xushu 15-4 with low cold storage tolerance was analyzed using 2-D and MALDI-TOF/TOF analyses. Compared with the control (without cold treatment), four protein spots were newly expressed in Xushu 15-1. The expression level of one protein spot was higher in Xushu 15-4 than in Xushu 15-1. Spot 2, which was newly expressed in Xushu 15-1, was identified as sporamin. Assessment of the change in protein expression levels over 8 weeks in the storage roots of the two cultivars treated at 4℃ revealed no significant difference in the expression levels in Xushu 15-1 over time. However, in Xushu 15-4, the expression level of one protein spot increased, while those of four spots decreased. Of the proteins with reduced expression levels, spots 7 and 8 were identified as actin and spots 9 and 10 were identified as fructokinase-like proteins. The present results are expected to enhance the understanding of the complex mechanism underlying the low temperature tolerance of sweet potatoes during storage and can be used to identify candidate genes for the development of new varieties of sweet potatoes with improved low temperature tolerance during cold storage in the future.

Effects of Light Intensity, Light Quality and Photoperiod for Growth of Perilla in a Closed-type Plant Factory System (완전제어형 식물공장에서 광량과 광질, 광주기가 들깨의 생장에 미치는 영향)

  • Sul, Seonggwan;Baek, Youngtaek;Cho, Young-Yeol
    • Journal of Bio-Environment Control
    • /
    • v.31 no.3
    • /
    • pp.180-187
    • /
    • 2022
  • In order to select suitable light in a plant factory, electric energy use efficiency and light use efficiency should be considered simultaneously to consider operating costs as well as quantitative and functional aspects. The growth characteristics, electric energy use efficiency, light use efficiency by light intensity, LED ratio, and photoperiod conditions were compared together. Light intensity is 60, 130, 230, and 320 µmol·m-2·s-1 treatments, and light quality is the mixing ratio of red light and blue light 8:2, 6:4, 4:6, and 2:8 treatments. Photoperiod is 9, 12, 15, and 18 hours treatments based on the daytime. In the light intensity experiment, the growth rate increased as the light intensity increased, but there was no significant difference in the light use efficiency. When comparing the leaf fresh weight per power consumption, only the 320 µmol·m-2·s-1 treatment group showed significantly low efficiency, and there was no significant difference in the other treatments, so 230 µmol·m-2·s-1, which produced the most, was the most efficient. In the light quality experiment, the ratio of red light and blue light was measured to be high at the same time as the growth rate and light use efficiency in RB 8:2, and there was no significant difference in color difference and flavonoids content, so a Red:Blue ratio of 8:2 was the most suitable condition. In the photoperiod experiment, the longer the photoperiod, the higher the growth rate. However, there was no significant difference in the growth rate over 12 hours of daytime, so 12 hours considering the light consumption efficiency was a suitable condition. Based on the above results, LED light environmental conditions for perilla growth in plant factories were light intensity, light quality, and day length of 230 µmol·m-2·s-1 or more, 8:2, and 12 hours or more, respectively.

Evaluation of HbA1c Levels Via the Latex Immunoturbidimetric Method by Using Chemistry Autoanalyzer (자동화학분석기에서의 라텍스 면역비탁법의 Autolab HbA1c 평가)

  • Jo, Yongjun;Lee, So-young;Park, Hae-il;Kim, YeongSic;Lee, Jehoon;Kim, Yonggoo;Han, Kyungja
    • Laboratory Medicine Online
    • /
    • v.2 no.1
    • /
    • pp.10-14
    • /
    • 2012
  • Background: Measurement of HbA1c levels is widely used to diagnose diabetes mellitus and to evaluate and monitor plasma-glucose concentrations over 6-8 weeks. In this study, we evaluated the diagnostic performance of the newly developed latex immunoturbidimetric method by using Autolab HbA1c. Methods: We analyzed and compared the diagnostic performance of Autolab HbA1c with that of Toshiba 200FR between April 2009 and July 2009. According to guidelines (EP5-A2, EP6-P, EP9-A2) of the clinical and laboratory standards institute (CLSI), we compared linearity, precision and correlation of Autolab HbA1c with those of G7 (Tosoh Corp., Kyoto, Japan) by using high-performance liquid chromatography (HPLC) method. Results: Data obtained using Autolab HbA1c showed good linearity in mixtures of samples with low (3.1%) and high (15.1%) levels of HbA1c (r2=0.9997). In the analysis of within-run precision of the samples with HbA1c levels of 5.1% and 12.1%, the SDs were 0.04 and 0.06 and covariances of these samples were 0.8% and 0.5%, respectively. In the Deming regression model, the regression equation was as follows: Autolab HbA1c=1.0859×Tosoh HPLC-0.6957. Conclusions: In this study, Autolab HbA1c method showed better performance characteristics than Tosoh G7 did. In reference review, there was no interference of variant hemoglobin. The data acquisition time of Autolab HbA1c was lower than that of Tosoh G7. The advantages of Autolab HbA1c are that it can be used as an autoanlyzer in routine chemical analysis, it does not require pre-analytical treatment, and the samples are automatically treated with distilled water for hemolysis.

Effect of Oil in Water Nanoemulsion Containing a Mixture of Lactic Acid and Gluconolactone for Skin Barrier Improvement (유산 및 글루코노락톤 혼합물을 함유하는 수중유형 나노에멀젼의 피부장벽개선 효과)

  • Ji-Hye Hong;Young Duck Choi;Gye Won Lee;Young Ho Cho
    • Journal of Life Science
    • /
    • v.33 no.11
    • /
    • pp.905-914
    • /
    • 2023
  • To evaluate the effectiveness of the skin barrier improvement of lactic acid (LA) and gluconolactone (GL), the expression of filaggrin, loricrin, hyaluronic acid (HA), hyaluronan syhthase-2 (HAS2), and aquaporine-3 (AQP3) in keratinocytes, and the moisture content and transepidermal water loss (TEWL) by clinical trials were evaluated. The expression levels of filaggrin and locricrin, which are the main factors affecting the proper functioning of skin barrier function, and HA, HAS2, and AQP3, which are skin moisturizing-related proteins measured by quantitative real-time polymerase chain reaction (qRT-PCR) and western blotting. The results showed that the expression levels of the factors that decreased by H2O2 treatment were significantly increased by LA, GL, and a mixture of LA and GL at the mRNA and protein levels (p<0.05). The nanoemulsion containing a mixture of LA and GL was prepared using the emulsion inversion method, and the average particle size was 299.9 ± 0.287 nm. After measuring the TEWL of nanoemulsion using Vapometer, it was found that TEWL significantly decreased by 15.53% and 26.73% after two weeks and four weeks of product use, respectively, compared to TEWL before product use (p<0.001). Similarly, the skin moisture content of the nanoemulsion significantly increased by 15.40% and 26.59% after two weeks and four weeks of product use, respectively, compared to skin moisture content before product use (p<0.001). Therefore, the skin barrier function and moisturizing effect of a mixture of LA and GL are shown by increasing the moisture content and decreasing the TEWL by increasing the expression of filaggrin, loricrin, HA, HAS2, and AQP3. This suggests the possibility for the development of functional cosmetic ingredients in the future.

Recognition and Attitude to Implement at ion of Service Area Assigned System of Public Health Programs among the Health Officer (공공보건사업의 지역담당제 실시에 관한 보건기관 근무 공무원의 인식과 태도)

  • Kim, Mi-Soon;Lee, Moo-Sik;Kim, Nam-Song
    • Journal of agricultural medicine and community health
    • /
    • v.26 no.2
    • /
    • pp.15-41
    • /
    • 2001
  • Since medical clients and the community they live in are expected to be center of future public health and medical care system, new service programs must be developed with patients focused on in line with widening public access of information and social participation. Patients- focused service shall mean the area- oriented provision of public health service. In this study, health officers working at public health centers, public health sub- centers and medical offices in Jeonbuk- do area were taken for population in order to investigate their attitudes toward and knowledge about the service area assigning system under the public health programs. Findings from the survey to 260 health officers, divided by general category, are as follows : Government officers at public health organizations appeared to have high grade of understanding to the service area assigning system and also great appreciation for the necessity of it. Regarding the timing for the system to be introduced, they support the gradual implementation and, as for the type of service to be provided, they preferred home nursing and treatment of chronic diseases. Highly positive responses were centered on the health classes under the health promotion projects, and as far as health projects for the old are concerned, services for home nursing, for the disabled and for home- alone people are favored most. On the other hand, budgeting, manpower and reorganization are rated as prerequisite to establishment of the service area assigning system. From the viewpoint of system side, the improvement of working conditions is rendered as most urgent, while the information system for establishing the service area assigning system is conceived far from satisfactory. Proper assignment of specialists was noted as mostly important to establish the delivery system for medical service through the service area assigning system by team. As merits of the service area assigning system, it is pointed out that, through the system, health clients can better be managed and the nursing quality will be improved thank to the enhanced specialization. It is also perceived that the district health service is not well prepared to respond to the increased and diversified needs of community people and, furthermore, service programs of health centers have not been fully developed. The most serious problem standing in the way to expansion of health projects is, it is noted, uniformity (formality) of the project. Based on the results of the survey which suggest time has ripen to introduce the service area assigning system, following strategies are proposed to anchor down the system as soon as possible: First, we should introduce the system gradually, starting from the area selected, and in consideration of area specialities, refraining from the hitherto stereotyped way of providing health service. Second, we should seek to properly assign the specialists and improve the working conditions of the assigned officers by securing sufficient budget, since it is a most urgent step to lay foundation for the service area assigning system. Third, best service program should be developed to meet the satisfaction of community people by responding to their needs and solidifying the management of medical clients. Fourth, wide scope of study should further be conducted in order to help this system take roots in the central living of community residents since pilot project on the experimental base attended by specialists only can not win popularity among the masses.

  • PDF

Radiation Therapy and Chemotherapy after Breast Conserving Surgery for Invasive Breast Cancer: An Intermediate Result (침윤성 유방암에서 유방보존수술 후 방사선치료 및 항암화학 병용치료의 성적 및 위험인자 분석)

  • Lee, Seok-Ho;Choi, Jin-Ho;Lee, Young-Don;Park, Heoung-Kyu;Kim, Hyun-Young;Park, Se-Hoon;Lee, Kyu-Chan
    • Radiation Oncology Journal
    • /
    • v.25 no.1
    • /
    • pp.16-25
    • /
    • 2007
  • [ $\underline{Purpose}$ ]: Breast conserving surgery (BCS) followed by chemotherapy (CTx.) and radiation therapy (RT) is widely performed for the treatment of early breast cancer. This retrospective study was undertaken to evaluate our interim results in terms of failure patterns, survival and relative risk factors. $\underline{Materials\;and\;Methods}$: From January 1999 through December 2003, 129 patients diagnosed with invasive breast cancer and treated with BCS followed by RT were subject to retrospective review. The median age of the patients was 45 years (age distribution, $27{\sim}76$ years). The proportions of patients according to their tumor, nodes, and metastases (TNM) stage were 65 (50.4%) in stage I, 41 (31.7%) in stage IIa, 13 (10.1%) in stage IIb, 9 (7.0%) in stage III, and 1 patient (0.8%) in stage IIIc. For 32 patients (24.8%), axillary node metastasis was found after dissection. BCS consisted of quadrantectomy in 115 patients (89.1%) and lumpectomy in 14 patients (10.6%). Axillary node dissection at axillary level I and II was performed for 120 patients (93%). For 7 patients (5.4%), only sentinel node dissection was performed with BCS. For 2 patients (1.6%) axillary dissection of any type was not performed. Postoperative RT was given with 6 MV X-rays. A tumor dose of 50.4 Gy was delivered to the entire breast area using a tangential field with a wedge compensator. An aditional dose of $9{\sim}16\;Gy$ was given to the primary tumor bed areas with electron beams. In 30 patients (23.3%), RT was delivered to the supraclavicular node. Most patients had adjuvant CTx. with $4{\sim}6$ cycles of CMF (cyclophosphamide, methotrexate, 5-fluorouracil) regimens. The median follow-up period was 50 months (range: $17{\sim}93$ months). $\underline{Results}$: The actuarial 5 year survival rate (5Y-OSR) was 96.9%, and the 5 year disease free survival rate (5Y-DFSR) was 93.7%. Local recurrences were noted in 2 patients (true: 2, regional node: 1) as the first sign of recurrence at a mean time of 29.3 months after surgery. Five patients developed distant metastases as the first sign of recurrence at $6{\sim}33$ months (mean 21 months). Sites of distant metastatic sites were bone in 3 patients, liver in 1 patient and systemic lesions in 1 patient. Among the patients with distant metastatic sites, two patients died at 17 and 25 months during the follow-up period. According to stage, the 5Y-OSR was 95.5%, 100%, 84.6%, and 100% for stage I, IIa, IIb, and III respectively. The 5Y-DFSR was 96.8%, 92.7%, 76.9%, and 100% for stage I, IIa, IIb, and III respectively. Stage was the only risk factor for local recurrence based on univariate analysis. Ten stage III patients included in this analysis had a primary tumor size of less than 3 cm and had more than 4 axillary lymph node metastases. The 10 stage III patients received not only breast RT but also received posterior axillary boost RT to the supraclavicular node. During the median 53.3 months follow-up period, no any local or distant failure was found. Complications were asymptomatic radiation pneumonitis in 10 patients, symptomatic pneumonitis in 1 patient and lymphedema in 8 patients. $\underline{Conclusion}$: Although our follow up period is short, we had excellent local control and survival results and reaffirmed that BCS followed by RT and CTx. appears to be an adequate treatment method. These results also provide evidence that distant failure occurs earlier and more frequent as compared with local failure. Further studies and a longer follow-up period are needed to assess the effectiveness of BCS followed by RT for the patients with less than a 3 cm primary tumor and more than 4 axillary node metastases.

The Alignment Evaluation for Patient Positioning System(PPS) of Gamma Knife PerfexionTM (감마나이프 퍼펙션의 자동환자이송장치에 대한 정렬됨 평가)

  • Jin, Seong Jin;Kim, Gyeong Rip;Hur, Beong Ik
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.3
    • /
    • pp.203-209
    • /
    • 2020
  • The purpose of this study is to assess the mechanical stability and alignment of the patient positioning system (PPS) of Leksell Gamma Knife Perfexion(LGK PFX). The alignment of the PPS of the LGK PFX was evaluated through measurements of the deviation of the coincidence of the Radiological Focus Point(RFP) and the PPS Calibration Center Point(CCP) applying different weights on the couch(0, 50, 60, 70, 80, and 90 kg). In measurements, a service diode test tool with three diode detectors being used biannually at the time of the routine preventive maintenance was used. The test conducted with varying weights on the PPS using the service diode test tool measured the radial deviations for all three collimators 4, 8, and 16 mm and also for three different positions of the PPS. In order to evaluate the alignment of the PPS, the radial deviations of the correspondence of the radiation focus and the LGK calibration center point of multiple beams were averaged using the calibrated service diode test tool at three university hospitals in Busan and Gyeongnam. Looking at the center diode for all collimators 4, 8, and 16 mm without weight on the PPS, and examining the short and long diodes for the 4 mm collimator, the means of the validation difference, i.e., the radial deviation for the setting of 4, 8, and 16 mm collimators for the center diode were respectively measured to 0.058 ± 0.023, 0.079 ± 0.023, and 0.097 ± 0.049 mm, and when the 4 mm collimator was applied to the center diode, the short diode, and the long diode, the average of the radial deviation was respectively 0.058 ± 0.023, 0.078 ± 0.01 and 0.070 ± 0.023 mm. The average of the radial deviations when irradiating 8 and 16 mm collimators on short and long diodes without weight are measured to 0.07 ± 0.003(8 mm sd), 0.153 ± 0.002 mm(16 mm sd) and 0.031 ± 0.014(8 mm ld), 0.175 ± 0.01 mm(16 mm ld) respectively. When various weights of 50 to 90 kg are placed on the PPS, the average of radial deviation when irradiated to the center diode for 4, 8, and 16 mm is 0.061 ± 0.041 to 0.075 ± 0.015, 0.023 ± 0.004 to 0.034 ± 0.003, and 0.158 ± 0.08 to 0.17 ± 0.043 mm, respectively. In addition, in the same situation, when the short diode for 4, 8, and 16 mm was irradiated, the averages of radial deviations were 0.063 ± 0.024 to 0.07 ± 0.017, 0.037 ± 0.006 to 0.059 ± 0.001, and 0.154 ± 0.03 to 0.165 ± 0.07 mm, respectively. In addition, when irradiated on long diode for 4, 8, and 16 mm, the averages of radial deviations were measured to be 0.102 ± 0.029 to 0.124 ± 0.036, 0.035 ± 0.004 to 0.054 ± 0.02, and 0.183 ± 0.092 to 0.202 ± 0.012 mm, respectively. It was confirmed that all the verification results performed were in accordance with the manufacturer's allowable deviation criteria. It was found that weight dependence was negligible as a result of measuring the alignment according to various weights placed on the PPS that mimics the actual treatment environment. In particular, no further adjustment or recalibration of the PPS was required during the verification. It has been confirmed that the verification test of the PPS according to various weights is suitable for normal Quality Assurance of LGK PFX.