• Title/Summary/Keyword: Time to contact

Search Result 2,989, Processing Time 0.05 seconds

Effect of current density and contact time on membrane fouling in electrocoagulation-MBR and their kinetic studies on fouling reduction rate (전기응집-MBR 공정의 전류밀도와 접촉시간이 막 오염에 미치는 영향과 막 오염 저감 속도론적 고찰)

  • Um, Se-Eun;Chang, In-Soung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.4
    • /
    • pp.321-328
    • /
    • 2017
  • Recently EC-MBR (Elctrocoagulation - Membrane Bio Reactor) has been suggested as one of alternative processes to overcome membrane fouling problems. Most important operational parameters in the EC-MBR are known to current density and contact time. Their effect on membrane filtration performances has been reported well, however, quantitative interrelationship between both parameters not been investigated yet. The purpose of this study is to give a kinetic model suggesting the current density and the contact time required to reduce the membrane fouling. The 4 different set of current densities (2.5, 6, 12 and $24A/m^2$) and contact times (0, 2, 6 and 12 hr) were selected as operational parameters. After each electro-coagulation under the 16 different conditions, a series of membrane filtration was carried out. The membrane fouling decreased as the current density and contact time increased, Total fouling resistances under different conditions, $R_t(=R_c+R_f)$ were calculated and compared to those of the controls ($R_0$), which were calculated from the data of experiments without electro-coagulation. A kinetic approach for the fouling reduction rate ($R_t/R_0$) was carried out and the equation ${\rho}^{0.46}_it=7.0$ was obtained, which means that the product of current density and the contact time needed to reduce the fouling in certain amounts (in this study, 10% of fouling reduction) is always constant.

A Study on the Elastic-Plastic Contact Problem for Large Deformation (대변형 탄소성 접촉문제에 관한 연구)

  • Jeon, Byung-Hee;Kim, Dong-Won
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.7 s.94
    • /
    • pp.1658-1667
    • /
    • 1993
  • In this research, a numerical algorithm has been developed, which can be applied to the large deformation and large displacement contact problems between two deformable bodies. The contact conditions expressed in terms of the rate of angle change have been proposed considering the change in geometric shape and rate of contact force. A set of linear simultaneous equations is constructed by adding the geometric shape change and contact conditions to the original stiffness matrix. A new method to determine time increment has been proposed based on Euler method, in which the condition to prevent the contact bodies from penetrating and overrunning each other has been taken into consideration. Practical application to contact problem is extrusion in which bodies are sliding along the contact boundary.

Effects of Centric Relation Splint Therapy on the Occlusal Contact State in Craniomandibular Disorders (교합안정장치 치료가 교합접촉상태에 끼치는 효과)

  • Whan-Cheol Kim;Kyung-Soo Han;Seok-Man Kang
    • Journal of Oral Medicine and Pain
    • /
    • v.18 no.2
    • /
    • pp.71-79
    • /
    • 1993
  • Many types of occlusal splints are used for treatment of craniomandibular disorders. Most widely used splint among them is flat-type centric relation splint. Insertion of splint into the mouth may cause increasing of vertical dimension, masticatory muscle realignment and rearrangement of maxillo-mandibular relationship, so as a result of splint treatment, occlusal relation may vary whether you like it or not. From this point of view, occlusal state of patient shold be frequently monitored to prevent undesired or harmful effect during occlusal splint therapy. The purpose of this study was to investigate the effect of occlusal splint, especially centric relation splint, on the occlusal contact state after 3 months treatment. 32 patients with craniomandibular disorders who had unilateral symptoms participated in this study. To observe and record occlusal contact state, the author used T-Scan system (Tekscan Co. U.S.A.) at both pretreatment and posttreatment. The recorded date were analyzed with regard to contact number, contact force and contact time, change of anterior tooth contact and coincidence of first contact point with affected side were observed, too. Aan last, the subjects were divided into 2 groups and compared, according to average value of VAS index, with respect to joint pain, sound and limitation of movement, respectively. The collected date were statistically processed with SPSS and the result as follows : 1. Total occlusal contact number and force were not changed by occlusal splint therapy but total occlusal contact time decreased slightly. 2. There was a tendency of increasing number of subjects with anterior tooth contact after treatment and change of first contact point side were observed in as many as 40.6% of subjects. 3. There were no difference between higher and lower group of VAS index, and between pretreatment and posttreatment in each group, either.

  • PDF

Effects of UV-A Blocking Contact Lenses on the Enzymes Denaturation Induced by UV-A Irradiation (UV-A로 유발된 효소 변성에 대한 콘택트렌즈의 차단 효과)

  • Park, Mijung;Lee, Keum Hee;Lee, Eun Kyung;Park, Sang Hee;Kim, So Ra;Lee, Heum Sook
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.4
    • /
    • pp.43-49
    • /
    • 2008
  • Purpose: The current study was conducted to evaluate the compatibility of UV-A blocking contact lens on eye protection with regular contact lens. Methods: The protective activity of regular contact lens (UV-A blocking: 20%) and UV-A blocking contact lens (UV-A blocking: 85%) on the denaturation of RNase A, catalase, and superoxide dismutase (SOD) induced UV-A irradiation were compared by acrylamide gel electrophoresis. The enzyme solutions were irradiated with UV-A for 1, 3, 6, 24 and 96 hours at the wavelength of 365 nm. Covering area with contact lenses were varied as 50%, 70% and 100% according to the calculation of blocking areas of anterior eye that could be covered with RGP lens, soft contact lens, and eye glasses, respectively. Results: Denaturations of RNase, catalase and SOD were exaggerated when they were exposed to UV-A for a longer period. The denaturation was effectively prevented by UV-A blocking contact lens compared to regular contact lens. The capability of UV-A blocking contact lens was considerably reduced when the covering area with contact lens decreased and exposure time to UV-A extended. Conclusion: Therefore, it would be suggested that wearing contact lens for a long time under sunlight is carefully considered since the activity of UV-A blocking contact lens against UV-A irradiation may not be enough to protect enzymes presented in eyes when exposure time to UV-A increased.

  • PDF

The Effect of Customer Contact on Hotel Service Quality (고객접촉이 서비스품질에 미치는 영향)

  • Jung, Moon-Young;Cho, Geon-Seob
    • Korean Business Review
    • /
    • v.19 no.1
    • /
    • pp.193-221
    • /
    • 2006
  • Customer Contact, defined as "the extent of interpersonal interaction between customer and service provider", is recognized as an important contributor to the perception of service quality, which in turn brings positive impacts on customer satisfaction, customer retention and loyalty especially in service contexts. The major purposes of this study are to explore the dimensionality of customer contact construct, to access the influences of customer contact dimensions on service quality dimensions, and to evaluate the relative importance of customer contact dimensions on service quality. Data from 388 customers of hotels at youngdong area in Kangwon-do were analyzed with major findings and their implications for service companies including hotels are as follows. First of all, the results of factor analysis show that customer contact is constructed with two dimensions, namely communication time and contact proximity. Secondly, overall customer contact is found to have positive effects on customers' perception of overall service quality and each dimension of customer contact has significant effects on overall service quality. Third, contact proximity dimension has relatively more important contributors than communication time has on overall service quality and four dimensions of service quality.

  • PDF

Robust Controller Design using SSV (${\mu}$) for Teleoperated Robot System with Time-Delay (구조적 특이값(${\mu}$)을 이용한 시간지연이 있는 원격조작 로봇시스템의 견실제어기 설계)

  • Jeong, Kyu-Won
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.2 no.1
    • /
    • pp.35-44
    • /
    • 1996
  • A design method for a teleoperator robot system is presented in this paper. The control system consists of two phases; approach phase and contact one. The end-effector position of the estimated slave robot and the contact force between the end-effector and wall are displayed on the monitors at control site, using which the operator controls the teleoperator system. The approach phase controller is designed using Smith's principle and the contact one designed based upon the structured singular value ${\mu}$ in order to increase the robustness of the system. The uncertainatices such as communication time delay and the variations of system parameters are considered as a muliplicative pertubation. Computer simulations are conducted in order to evaluate the performance of the proposed design method. It is found that desirable control performance, especially in the contact phase, is obtained if the control mode is switched into contact phase when the estimated position of the slave robot end-effector is in front of the wall.

  • PDF

Microbial Quality and Safety of Fresh-Cut Broccoli with Different Sanitizers and Contact Times

  • Das, Basanta Kumar;Kim, Ji-Gang
    • Journal of Microbiology and Biotechnology
    • /
    • v.20 no.2
    • /
    • pp.363-369
    • /
    • 2010
  • This study was conducted to investigate the effects of different sanitizers and contact times on storage quality and microbial growth in fresh-cut broccoli. Fresh broccoli samples were cut into small pieces, washed each for 90 s and 180 s in normal tap water (TW), $100\;{\mu}/l$ chlorinated water (CL, pH 7), electrolyzed water (EW, pH 7.2) containing $100\;{\mu}/l$ free chlorine, or $2\;{\mu}/l$ ozonated water ($O_3$). Then, samples were packaged in 30-${\mu}m$ polyethylene bags and stored at $5^{\circ}C$ for 9 days. No significant differences were observed in gas composition and color parameters ($L^*$, $a^*$, $b^*$, and hue angle) among different sanitizers with contact times. No off-odor was detected during the storage. A longer contact time was not effective in reducing microbial population, except with $O_3$ washing. $O_3$ with 90 s was not much effective in reducing microbial population compared with Cl or EW. However, samples washed with $O_3$ for 180 s observed the lowest numbers of total aerobic and coliform plate counts. The result suggested that, a longer contact time of ozone can be used as a potential sanitizer to maintain the microbial quality and safety of fresh-cut broccoli.

Development of a Novel System for Measuring Sizing Degree Based on Contact Angle(I) - Development of a Novel Principle for Automatic Measurement of Contact Angle - (접촉각 측정 원리를 이용한 새로운 사이즈도 측정기 (제1보) -자동 접촉각 측정 원리의 개발 -)

  • 이찬용;김철환;최경민;박종열;권오철
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.35 no.3
    • /
    • pp.43-52
    • /
    • 2003
  • The new principle to measure a sizing degree by a contact angle was developed using an automatic determination of the 3-end point coordinates of the water droplet on a sheet, which could diminish the operator's bias during measurement. A constant amount of water was first placed on a sample sheet by a water dispenser, and then an image of the liquid droplet was captured by a digital camera and then transmitted to a computer. The program measuring for contact angle extracted a liquid contour by Gaussian function combined with a 8-direction chain code. The Euclidean equation was applied to the binary image of the liquid contour in order to measure the diameter of the contour. Finally, the contact angle of the liquid was calculated by using the diameter and the top coordinates. In addition, a surface free energy of the sample sheet and an elapsed time taken up to the complete absorption into the sheet were simultaneously measured with the contact angle.

Analysis of Hertzian Contact using East Fourier Transform (FFT를 이용한 Hertzian Contact 해석)

  • 구영필;조용주
    • Tribology and Lubricants
    • /
    • v.14 no.4
    • /
    • pp.121-127
    • /
    • 1998
  • In this study, a numerical procedure to solve a contact problem has been developed. The procedure takes advantage of signal processing technique in frequency domain to achieve shorter computing time. Boussinesq's equation was adopted as the response function. This procedure is applicable to a non-periodic surface profile as well as a periodic one. The validity of this procedure has been established by comparing the numerical results with the exact solutions. The fastness of this procedure was shown in comparison with other algorithm.

Analysis of Hertzian Contact using Fast Fourier Transform (FFT를 이용한 Hertz Contact 해석)

  • 구영필;조용주
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1998.04a
    • /
    • pp.131-138
    • /
    • 1998
  • In this study, a numerical procedure to solve a contact problem has been developed. The procedure takes the advantage of signal processing technique in frequency domain to achieve the shorter computer processing time. The Boussinesq's equation was adopted as the response function. This procedure is applicable to the non-periodic surface profile as well as the periodic one. The validity of this procedure has been established by comparing the numerical results with the exact solutions. The effectiveness of this procedure is lied on the shorter computing time than any other contact analysis algorithm.

  • PDF