• 제목/요약/키워드: Time taken for initial water discharge

검색결과 2건 처리시간 0.016초

Measurement of the Time Taken for Initial Water Discharge According to the Number of Kinks in the Fire Hose of the Indoor Hydrant System

  • Hong, Suk-Hwan;Kong, Ha-Sung
    • International Journal of Advanced Culture Technology
    • /
    • 제9권3호
    • /
    • pp.360-366
    • /
    • 2021
  • In this study, we tried to examine how the kinking of the fire hose affects the time taken for initial water discharge by measuring and analyzing the time taken for initial water discharge with different number of kinks at different locations of the hose. The average time taken for initial water discharge was obtained by measuring the time in the unkinked state of the fire hose. Based on this standard, we conducted the experiment by selecting the kinking locations in the hose near the water outlet and nozzle, and setting the number of kinks to 3, 6, 9, and 12. The results of this study are as follows: First, if the fire hose has 5 kinks or more near the nozzle, no water was released. Second, when comparing the case of no kinks and 4 kinks near the nozzle, there was no significant difference in the time taken for initial water discharge. Third, when the fire hose was kinked 10 times near the outlet, the time required for initial water discharge increased by 1.62 seconds on average compared to the case with no kinking, but there was no problem with water discharge. Lastly, regarding the kinking locations of the fire hose, it was found that the greater the number of kinks near the nozzle than near the outlet, the greater the effect on the discharge. As a result, it is concluded that it would be preferable to install non-kinking devices near the nozzle of the fire hose.

냉각재 상실사고 분석 및 재충진 단계해석용 전산코드 개발 (LOCA Analysis and Development of a Simple Computer Code for Refill-Phase Analysis)

  • Ree, Hee-Do;Park, Goon-Cherl;Kim, Hyo-Jung;Kim, Jin-Soo
    • Nuclear Engineering and Technology
    • /
    • 제18권3호
    • /
    • pp.200-208
    • /
    • 1986
  • 원자로 냉각 계통의 배관 파열에 근거한 냉각재 상실 사고를 방출계수 0.4에 대하여 분석하였다. 분석은 원자로 냉각계통의 배관 파열에 의하여 발생된 감압부터 노심 복구까지의 전 과도 상태를 포함한다. 계통 열수력과 핵연료 성능 평가를 위하여 BLOWDOWN 단계에서는 RELAP4/MOD6-EM 코드와 RELAP4/MOD6-HOT CHANNEL 코드를 사용하였으며 REFLOOD 단계에서는 RELAP4/ MOD6-FLOOD 코드와 TOODEE2 코드를 각각 사용하였다. LOWER PLENUM 충전을 고려하기 위하여 DOWNCOMER에서 증기-물역방향 유동과 과열벽효과를 근사하여 간단한 해석적 모델이 개발되었다. EOB 발생시의 정보를 근거로 하여 재충전지속 시간과 초기 복구 온도가 계산되었으며 RELAP4/MOD6에 의한 분석결과와 비교하여 상당한 일치를 보였다. 또한, 조기 EOB 발생에 영향을 미치는 계통변수의 연구가 수행되어졌다. DOWNCOMER와 UPPER HEAD사이의 마찰손실이 조기 EOB 발생에 지대한 영향을 미쳤으며 적당한 마찰손실계수의 선택을 통하여 조기 EOB 발생을 방지할 수 있었다. 노심 nodalization이 여섯 개인 경우와 세 개인 경우의 분석 결과가 계통열수력학적 면에서 유사한 결과를 나타내지만, 좋은 결과를 얻기 위하여 전자의 경우가 요구된다.

  • PDF