• Title/Summary/Keyword: Time progress

Search Result 2,177, Processing Time 0.028 seconds

Evaluation of Dosimetric Characteristics of Reproducibility, Linearity and Dose Dependence of Optically Stimulated Luminescence Dosimeters in Co-60 Gamma-rays (Co-60 감마선을 이용한 광자극발광선량계의 재현성, 선형성, 선량의존성에 대한 특성평가)

  • Han, Su Chul;Choi, Sang Hyoun;Park, Seungwoo;Kim, Chul Hang;Jung, Haijo;Kim, Mi-Sook;Yoo, Hyung Jun;Kim, Chan Hyeong;Ji, Young Hoon;Yi, Chul Young;Kim, Kum Bae
    • Progress in Medical Physics
    • /
    • v.25 no.1
    • /
    • pp.31-36
    • /
    • 2014
  • We aimed to evaluate the dosimetric characteristics of reproducibility, linearity and dose dependence of optical stimulated luminance dosimeter (OSLD) in the Co-60 Gamma-rays and to analyze with a precedent study in field of the diagnostic radiography and radiotherapy. The reproducibility was 0.76% of the coefficient of variation, the homogeneity was within 1.5% of the coefficient of variation and OSLD had supra-linear response more than 3 Gy. So the correlation between dose and count was fitted by quadratic function. The count depletion by repeated reading was 0.04% per reading regardless of the irradiated dose. And the half time of decay curve according to the irradiated dose was 0.68 min. with 1 Gy, 1.04 min. with 5 Gy, and 1.10 min. with 10 Gy, respectively. In case of annealing for 30 min, the removal rate was 88% with 1 Gy, 90% with 5 Gy, and 92% with 10 Gy, respectively and 99% in case of annealing time for 4 hour. It is feasible to use OSLDs for dose evaluation in Co-60 Gamma-rays when considering the uncertainty on the procedure according to the irradiated dose.

Potential Risk Assessment of Cardiovascular Disease in Low Calcium-Score (낮은 칼슘 수치에서 심혈관질환의 잠재 위험도 평가)

  • Yoo, Heangsoo;Park, Jikoon;Jung, Bongjae;Noh, Sicheol;Choi, IlhHong;Jung, Hyungjn;Kang, Sangsik
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.6
    • /
    • pp.369-376
    • /
    • 2013
  • Prepared her for the early detection of the risk of cardiovascular disease prevention for the various attempts being made ill through a lot of research to the criteria of coronary artery calcification, but the figure is more than 100 the progress of the flow can be expected to be was. In this study, we quantify the correlation between body composition analysis, blood lipid levels of calcium and public asymptomatic even at low calcium levels in comparison with the existing studies by analyzing potential risk of cardiovascular disease will be represented on the were evaluated. Studies, the calcium scores in the body composition analysis "1-10", and when "11-100" when there was a significant correlation in BMI and WHR look more normal frequency range of the mean values in the normal range meomulreoteuna 21% relative HDL and TG in lipid profiles, no significant correlation look more normal frequency range of risk were derived from the mean values in the normal range, 21% to 40% of the relative risk were derived. meomulreoteuna. In addition, there is no correlation between BFM and BMR Also, average increases in the frequency of a higher standard was higher relative risk derived 31 to 93%, and geological correlation test TC above 20mg/dl atherosclerotic sclerosis seems to be the value of HDL to act to remove cholesterol from atheroma already looking at the same time to suppress the occurrence of atherosclerosis, increased LDL showed higher values occurs rapidly increasing. At this time, the relative risk of 43-50% have been identified. In other words, even when calcium levels are low, that is inherent in the incidence of cardiovascular disease was unknown.

The Development of a Ship Firefighting Drill Simulator (선박소화훈련 시뮬레이터 개발에 관한 연구)

  • Kim, Won-Ouk;Kim, Dae-Hee
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.22 no.5
    • /
    • pp.410-416
    • /
    • 2016
  • After the Sewol Ferry accident, the importance of maritime safety has been emphasized in Korea. In particular, educational and experience training are not only being conducted for maritime personnel but also in schools and at maritime-related organizations in order to broadly instill maritime safety awareness. Based on SOLAS regulations, safety education for sailors conducted every 10 days passenger boats, and fire-fighting drills and abandon-ship training should be conducted once a month on merchant ships. After the Sewol Ferry accident, the maximum number of trainees was reduced from 40 to 20 in order to improve the effectiveness of these training sessions by requiring all trainees to participate in the actual training. The current training process consists of two steps: textbook-based theoretical training and actual practice. Current training environment provides limited capability from human and facility recourses which limit the numbers of trainee participated and system operation time. By introducing the simulation training, it will improve the trainee skill and performance prior to the on-site training and allow the more effective and rapid progress on actual practice. Therefore, it will be proposed the three-step training method in order to improve the effectiveness on fire-fighting drill in Maritime Safety Education on this study. This study suggests a three step training method that would increase the efficiency of maritime safety education. An image-training step to enhance individual task awareness and equipment usage via simulation techniques after theoretical training has been added. To implement this simulation, a virtual training session will be conducted before actual training, based on knowledge obtained from theoretical training, which is expected to increase the speed with which trainees can adapt during the practical training session. In addition, due to the characteristics of the simulation, repeated training is possible for reaction drills in emergency circumstances and other various scenarios that are difficult to replicate in actual training. The efficiency of training is expected to improve because trainees will have practiced before practical training takes place, which will decrease the time needed for practical training and increase the number of training sessions that can be executed, increasing the efficiency of training overall. This study considers development methods for fire-fighting drill simulations using virtual reality techniques.

The Molecular Weight Dependance of Paramagnetic Gd-chelates on T1 and T2 Relaxation Times (상자성 복합체의 분자량에 따른 T1 및 T2 자기이완시간에 관한 연구)

  • Kim In-Sung;Lee Young-Ju;Kim Ju-Hyun;Sujit Dutta;Kim Suk-Kyung;Kim Tae-Jeong;Kang Duk-Sik;Chang Yong-Min
    • Progress in Medical Physics
    • /
    • v.17 no.2
    • /
    • pp.61-66
    • /
    • 2006
  • To evaluate the T1, T2 magnetic relaxation properties of water molecule according to molecular weight of paramagnetic complex. 4-aminomethyicyclohexane carboxylic acid (0.63 g, 4 mmol) was mixed with the suspension solution of DMF (15 ml) and DTPA-bis-anhydride (0.71 g, 2 mmol) to synthesize the ligand. The ligand was then mixed with $Gd_2O_3$ (0.18 g, 0.5 mmol) to synthesize Gd-chelate. For the measurement of magnetic relaxivity of paramagnetic compounds, the compounds were diluted to 1 mM and then the relaxation times were measured at 1.57 (64 MHz). Inversion-recovery pulse sequence was employed for T1 relaxation measurement and CPMG (Carr-Purcell-Meiboon-Gill) pulse sequence was employed for T2 relaxation measurement. In case of inversion recovery sequence, total 35 images with different inversion time(T1)s ranging from 50 msec to 1,750 msec. To estimate the relaxation times, the signal intensity of each sample was measured using region of Interest (ROI) and then fitted by non-linear least square method to yield T1, T2 relaxation times and also R1 and R2. Compared to T1=($205.1{\pm}2.57$) msec and T2=($209.4{\pm}4.28$) msec of Omniscan (Gadodiamide), which is commercially available paramagnetic MR agent, T1 and T2 values of new paramagnetic complexes were reduced along with their molecular weight. That is, T1 value was ranged from $(96.35{\pm}2.04)\;to\;(79.38{\pm}1.55)$ msec and T2 value was ranged from $(91.02{\pm}2.08)\;to\;(76.66{\pm}1.84)$ msec. Among new paramagnetic complexes, there is a tendency that the R1 and R2 increase as the molecular weight is increases. As molecular weight of paramagnetic complex increases, T1 and T2 relaxation times reduce and thus the increase of relaxivity (R1 and R2) Is proportional to molecular weight.

  • PDF

Reducing of Craniofacial Radiation Dose Using Automatic Exposure Control Technique in the 64 Multi-Detector Computed Tomography (64 다중 검출기 전산화단층촬영에서 관전류 자동노출조절 기법을 이용한 두개부 방사선량 감소 정도 평가)

  • Seoung, Youl-Hun;Kim, Yong-Ok;Choe, Bo-Young
    • Progress in Medical Physics
    • /
    • v.21 no.2
    • /
    • pp.137-144
    • /
    • 2010
  • The purpose of this study was to evaluate the usefulness of reducing of craniofacial radiation dose using automatic exposure control (AEC) technique in the 64 multi-detector computed tomography (MDCT). We used SOMATOM Definition 64 multi-detector CT, and head of whole body phantom (KUPBU-50, Kyoto Kagaku CO. Ltd). The protocol were helical scan method with 120 kVp, 1 sec of rotation time, 5 mm of slice thickness and increment, 250 mm of FOV, $512{\times}512$ of matrix size, $64{\times}0.625\;mm$ of collimation, and 1 of pitch. The evaluation of dose reducing effect was compared the fixed tube current of 350 with AEC technique. The image quality was measured the noise using standard deviation of CT number. The range of craniofacial bone was to mentum end from calvaria apex, which devided three regions: calvaria~superciliary ridge (1 segment), superciliary ridge~acanthion (2 segment), and acanthion~mentum (3 segment). In the fixed tube current technique, CTDIvol was 57.7 mGy, DLP was $640.2\;mGy{\cdot}cm$ in the all regions. The AEC technique was showed that 1 segment were 30.7 mGy of CTDIvol, 340.7 $mGy{\cdot}cm$ of DLP, 2 segment were 46.5 mGy of CTDIvol, $515.0\;mGy{\cdot}cm$ of DLP, and 3 segment were 30.3 mGy of CTDIvol, $337.0\;mGy{\cdot}cm$ of DLP. The standard deviation of CT number was 2.622 with the fixed tube current technique and 3.023 with the AEC technique in the 1 segment, was 3.118 with the fixed tube current technique and 3.379 with the AEC technique in the 2 segment, was 2.670 with the fixed tube current technique and 3.186 with the AEC technique in the 3 segment. The craniofacial radiation dose using AEC Technique in the 64 MDCT was evaluated the usefulness of reducing for the eye, the parotid and thyroid with high radiation sensitivity particularly.

Change of Flora of Damaged Land in Juwangsan National Park for Five Years (2010~2014) (주왕산국립공원 내 훼손지의 5년간(2010~2014년) 식물상 변화)

  • You, Juhan;Kim, Mijin
    • Journal of Environmental Impact Assessment
    • /
    • v.25 no.4
    • /
    • pp.233-247
    • /
    • 2016
  • The purpose of this study is to offer the basic data for management of National Park by surveying and analysing the change of flora of damaged lands in Juwangsan National Park, Korea. In cause of occurring the damaged lands, site-1 was the vegetation damage by stamping, the removing Gwangamsa of site-2, 3, 4 and the removing Naewon village of site-5, 6, 7. Whole sites are caused by the artificial disturbance and interference. The numbers of flora were summarized as 135 taxa including 52 families, 109 genera, 116 species, 2 subspecies and 17 varieties in whole sites. The status of flora by sites, site-6 is the largest number of 52 taxa, site-1 is the lowest of 23 taxa. The rare plant is 1 taxa, 4 taxa of endemic plants, 10 taxa of specific plants by floristic region, 9 taxa of naturalized plants and 1 taxa of invasive alien plant. In the results of analysis about the change of coverage ratio, for this shrub layer, site-7 was changed to the most $0%{\rightarrow}50%$, and the herb layer, site-5 was changed to the most $75%{\rightarrow}95%$. In case of the change of species numbers, most sites tended to increase in the sites introduced different species or generated by the growth. It is contemplated that is similar to the restoration with the surrounding natural vegetation that is in progress is a transition occurs with the passage of time. In the dominant species, the shrub layer is Fraxinus sieboldiana, Lespedeza bicolor, Rhus javanica, Lespedezamaximowiczii, Salix koreensis and Zelkova serrata, and Miscanthus sinensis var. purpurascens, Oplismenus undulatifolius, Artemisia princeps, Bothriochloa ischaemum and Erigeron annuus of herb layer. In the results of analysing Naturalized Index(NI) and Urbanized Index(UI), NI was increased or decreased this phenomenon with the lapse of time, UI was the most increase. In particular, the increase in UI is due to the transition process, the pioneering plant, naturalized plant was imported to continue.

Actual Condition of Quality Control of X-ray Imaging System in Primary Care Institution: focused on Gwangju Metropolitan City (1차 의료기관의 엑스선 발생장치 정도관리에 관한 현황조사:광주광역시 지역을 중심으로)

  • Dong, Kyung-Rae;Lee, Seun-Joo;Kweon, Dae-Cheol;Goo, Eun-Hoe;Jung, Jae-Eun;Lee, Kyu-Su
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.1
    • /
    • pp.34-42
    • /
    • 2010
  • With the expanded use of radiation in modern medical practices, the most important issue in regards to efforts to reduce individual exposure dose is quality assurance. Therefore in order to study the present condition of quality assurance, the Gwangju Metropolitan City area was divided into five districts each containing ten hospitals. Four experiments were conducted: a reproducibility experiment for kVp, mA, and examination time (sec) intensity of illumination; half-value layer (HVL) measurement; and beam perpendicularity test matching experiment. The tube voltage reproducibility experiment for all fifty hospitals resulted in a 95.33% passing rate and mA and examination time both resulted in a 77.0% passing rate. The passing rate for intensity of illumination was 86.0% and 52.0% for HVL, which was the lowest passing rate of all four factors. For the beam perpendicularity test matching experiment, generally the central flux is matched to within $1.5^{\circ}$. Of all fifty hospitals 30.0% were beyond $3^{\circ}$. The results of the survey showed that 58% responded that they knew about quality assurance cycle. All fifty respondents stated that they have not received any training in regards to quality assurance at their current place of employment. Although quality assurance is making relative progress, the most urgent issue is awareness of the importance of quality assurance. Therefore, the implementation of professional training focusing on safety management and accurate quality assurance of radiation will reduce the exposure to radiation for radiologists and patients and higher quality imaging using less dosage will also be possible.

p53 and c-erbB2 as the Immunohistochemical Markers in Patients with Squamous Cell Carcinoma of the Lung (편평상피 폐암 및 주위 정상조직에서 p53 및 c-erbB2 발현의 의의)

  • Song, Chang-Seuk;Ok, Chul-Ho;Jung, Yong-Seuk;Jang, Tae-Won;Jung, Maan-Hong;Lee, Jae-Seong;Jung, Hae-Jeen;Hur, Bahng;Hur, Man-Ha
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.4
    • /
    • pp.523-532
    • /
    • 1999
  • Background: With the development of the molecular biological methods, studies of the early diagnosis of lung cancer and the detection in the preneoplastic state by using genetic probes in the high risk groups are widely investigated. In lung cancer, squamous cell carcinoma is considered to progress from the normal bronchial mucosa to the preneoplastic state, and finally to the invasive carcinoma. In this study, we investigated the expression of p53 and c-erbB2 in the normal bronchi and the cancer tissues in patients with squamous cell lung cancer to evaluate the possibility of using these immunohistochemical markers as the diagnostic and prognostic parameters of patients with squamous cell lung cancer. Method: The normal and cancerous bronchial tissues of 25 patients with squamous cell carcinoma of the lung, surgically resected from May 1995 to November 1996, were immunohistochemically stained with the monoclonal antibodies to p53(DAKO-p53) and c-erbB2(phamingen 15821A) respectively. We compared the expression status of these markers between the normal bronchial mucosa and the tumor tissue, and also investigated the relationship between the expression status of these markers in tumor tissues and the pathological stage, and the survival time. Results: The pathological stage was as follows; stage I, II were found in 5 patients respectively, stage IIIA was in 8 patients, stage IIIB was in 4 patients, and stage IV was in 3 patients. The expression rate of p53 in the squamous cell lung cancer was 48%, and it was not expressed in the normal bronchial mucosa. The expression status was increased as the pathological stage advanced(p=0.0091 by test of trend). But there were no relationship between the expression of p53 and the median survival time. C-erbB2 did not yield a significantly meaningful result. Conclusion: p53 was not found in the normal bronchial mucosa, but it was expressed in 48% of the tumor tissue. And the expression rate increased as the pathological stage advanced. So it would be helpful to apply the immunochistochemical stain with p53 in the bronchial biopsy specimen in the early diagnosis trial or staging of squamous cell lung cancer.

  • PDF

Benchmark Results of a Monte Carlo Treatment Planning system (몬데카를로 기반 치료계획시스템의 성능평가)

  • Cho, Byung-Chul
    • Progress in Medical Physics
    • /
    • v.13 no.3
    • /
    • pp.149-155
    • /
    • 2002
  • Recent advances in radiation transport algorithms, computer hardware performance, and parallel computing make the clinical use of Monte Carlo based dose calculations possible. To compare the speed and accuracies of dose calculations between different developed codes, a benchmark tests were proposed at the XIIth ICCR (International Conference on the use of Computers in Radiation Therapy, Heidelberg, Germany 2000). A Monte Carlo treatment planning comprised of 28 various Intel Pentium CPUs was implemented for routine clinical use. The purpose of this study was to evaluate the performance of our system using the above benchmark tests. The benchmark procedures are comprised of three parts. a) speed of photon beams dose calculation inside a given phantom of 30.5 cm$\times$39.5 cm $\times$ 30 cm deep and filled with 5 ㎣ voxels within 2% statistical uncertainty. b) speed of electron beams dose calculation inside the same phantom as that of the photon beams. c) accuracy of photon and electron beam calculation inside heterogeneous slab phantom compared with the reference results of EGS4/PRESTA calculation. As results of the speed benchmark tests, it took 5.5 minutes to achieve less than 2% statistical uncertainty for 18 MV photon beams. Though the net calculation for electron beams was an order of faster than the photon beam, the overall calculation time was similar to that of photon beam case due to the overhead time to maintain parallel processing. Since our Monte Carlo code is EGSnrc, which is an improved version of EGS4, the accuracy tests of our system showed, as expected, very good agreement with the reference data. In conclusion, our Monte Carlo treatment planning system shows clinically meaningful results. Though other more efficient codes are developed such like MCDOSE and VMC++, BEAMnrc based on EGSnrc code system may be used for routine clinical Monte Carlo treatment planning in conjunction with clustering technique.

  • PDF

A Study of Optimized MRI Parameters for Polymer Gel Dosimetry (중합체 겔 선량측정법을 위한 최적의 자기공명영상 변수에 관한 연구)

  • Cho, Sam-Ju;Chung, Young-Lip;Lee, Sang-Hoon;Huh, Hyun-Do;Choi, Jin-Ho;Park, Sung-Ill;Shim, Su-Jung;Kwon, Soo-Il
    • Progress in Medical Physics
    • /
    • v.23 no.2
    • /
    • pp.71-80
    • /
    • 2012
  • In order to verify exact dose distributions in the state-of-the-art radiation techniques, a newly designed three-dimensional dosimeter and technique has been took strongly into consideration. The main purpose of our study is to verify the optimized parameters of polymer gel as a real volumetric dosimeter in terms of the various study of MRI. We prepared a gel dosimeter by combing 8% of gelatin, 8% of MAA, and 10 mM of THPC. We used a Co-60 gamma-ray teletherapy unit and delivered doses of 0, 2, 4, 6, 8, 10, 12, and 14 Gy to each polymer gel with a solid phantom. We used a fast spin-echo pulse to acquire the characterized T2 time of MRI. The signal noise ratio (SNR) of the head & neck coil was a relatively lower sensitivity than the body coil; therefore the dose uncertainty of head & neck coil would be lower than body coil's. But the dose uncertainty and resolution of the head & neck coil were superior to the body coil in this study. The TR time between 1,500 ms and 2,000 ms showed no significant difference in the dose resolution, but TR of 1,500 ms showed less dose uncertainty. For the slice thickness of 2.5 mm, less dose uncertainty of TE times was at 4 Gy, as well, it was the lowest result over 4 Gy at TE of 12 ms. The dose uncertainty was not critical up to 6 Gy, but the best dose resolution was obtained at 20 ms up to 8 Gy. The dose resolution shows the lowest value was over 20 ms and was an excellent result in the number of excitation (NEX) of three. The NEX of two was the highest dose resolution. We concluded that the better result of slice thickness versus NEX was related to the NEX increment and thin slice thickness.