레이다 도파관의 작동상태점검법에 관한 연구 (A Studyu on the Waveguide Running Condition Inspection of Radar)

  • 류대근
    • 한국항해학회지
    • /
    • 제5권2호
    • /
    • pp.41-47
    • /
    • 1981
  • Many new radar techniques have appeared on the electronic scene in recent years, such as a variety of automatic computer processing. However, even with the advent of these sophisticated radar techniques, an old problem continues to plague all radars: the problem of transmission line losses. With the higher performance required today, the Waveguide testing and trouble-shooting techniques remain essentially unchanged in principle. This paper dealt with the rf pulse "Time-domain Reflectometry" to inspect radar wave-guide system and compared with the conventional methods. During the investigation, it was verified that the pulsed TDR for wave-guide is superior to the conventional methods; 1. Disassembling is not needed to locate the discontinity points and measure the reflections of trobled points. 2. The results of the data are more precise. 3. The condition of individual component is able to the photographed and recorded permanently. 4. Since rf pulse TDR is based on the well-known basic radar principle, such a test set requires the minimum of training to operate. With the level of transmission line problems, the prospect of increasing complexity of equipment, and no relief in sight, the benifits must be emphasizied to adopt such a testing procedure.procedure.

  • PDF

함수비 특성곡선과 투수계수 특성곡선이 불포화토내에서의 물의 흐름에 미치는 영향분석 (Analysis of Influence by soil water-characteristic curve and permeability-suction relationship for the water flow in unsaturated soil)

  • 김석남
    • 한국방재학회 논문집
    • /
    • 제3권2호
    • /
    • pp.119-125
    • /
    • 2003
  • 불포화토에서 물의 흐름은 함수비 특성곡선과 투수계수 특성곡선(permeability-suction relation ship)이라 불리우는 두 방정식에 의해서 영향 받는다. 함수비 특성곡선은 체적함수비와 석션(suction)간의 관계를 나타내는 방정식이다. 많은 연구자들은 특성곡선식들을 제시해 왔다. 이 논문은 불포화토에서 물의 흐름을 분석할 때 특성곡선식들을 정확하게 결정하는 것이 중요하다는 것을 보여준다. 비교목적을 위해서 두 방법 즉, Gardner (1958)에 의해서 제시된 특성곡선식들과 Fredlund (1994) 의해서 제시된 특성곡선식들이 사용된다. 이 두 방법을 사용하여 유한요소법에 의한 물 흐름의 수치해석이 수행된다. 수치해석 결과들은 미 Ohio주 Delaware County에 있는 TDR (Time-domain reflectometry) 계측기로부터 얻어진 현장 데이터와 비교된다. 이 데이터는 전략적 고속도로 연구 프로그램(Strategic Highway Research Program)의 한 부분으로 포함된 계절 계측 프로그램(Seasonal Instrumentation Program)에 의해 얻어졌다.

Application of electrical resistivity for assessing characterizations of frozen and unfrozen soils

  • Dae-Hong Min;Hyung-Koo Yoon
    • Geomechanics and Engineering
    • /
    • 제38권2호
    • /
    • pp.205-214
    • /
    • 2024
  • Permafrost refers to the condition where the ground is frozen. It is crucial to review and evaluate the ground's characteristics before construction. In this study, electrical resistivity surveying is chosen as the investigative technique to apply and illustrate the results on the state of permafrost ground and to summarize its applicability. Field experiments are conducted in the Yeoncheon area of South Korea, which has a freezing index of 522.6°C·days. The target area is categorized into two ground conditions: the first where the original ground freezes, and the second involves excavating the original ground up to a depth of 3 meters, backfilling it, and then artificially injecting fluid. Thus, frozen ground conditions are simulated under both natural and artificial circumstances. Electrical resistivity surveys are performed under both above-freezing and sub-zero temperature conditions, with the experiments conducted at sub-zero temperatures revealing relatively more high-resistivity zones due to the temperature conditions. In this area, the distribution of soil moisture content is also investigated using the Time Domain Reflectometry (TDR) technique. It is observed that the ground into which water is artificially injected had a relatively higher moisture content, although the difference is minor. Finally, a 3D map of the target ground is constructed based on the measured electrical resistivity values, and through this, the distribution of porosity, a crucial design parameter, is also depicted. This research demonstrates that the electrical resistivity technique can effectively evaluate the state of frozen and unfrozen ground and further suggests that it can detailed extract the characteristics of the target ground.

에너지와 물수지 연계방법과 TDR로부터 얻어진 매일 토양 함수량의 비교 (Comparison of Daily Soil Water Contents between Energy BalanceWater Budget Approach and TDR)

  • 임창수
    • 물과 미래
    • /
    • 제29권4호
    • /
    • pp.119-129
    • /
    • 1996
  • 여름기간 동안 두 다른 준건조 기지역에 위치한 소유역들(Lucky Hills 그리고 Kendall)로부터 eddy 상관을 기초로 한 에너지 수지와 물수지 방법 그리고 TDR 방법을 이용하여 매일의 토양 함수량이 측정되어졌으며, 그 두 다른 방법들로부터 측정되어지고 계산되어진 매일의 토양 함수량에 대한 비교가 있었다. 그 비교는 유역을 대상으로 하는 경우에 있어서 eddy상관을 이용한 에너지 수지와 물수지 방법 그리고 TDR 방법을 사용한 토양 함수량 특정 방법에 대한 정확돌알아보는데 유용하다. 토양 함수량을 측정하는 이 두 방법들로부터 구해진 회귀 사이의 유사도는 이 방법들 사이의 상관 정도를 알아보는 것에 의해서 설명되어졌다. 단순선형상관분석은 Lucky Hills 유역에서는 TDR 방법에 의해서 측정된 토양 함수량이 에너지와 물수지 방법에 의해서 측정된 토양 함수량의 58% 정도임을 나타냈고, 그리고 Kendall 유역에서는 63% 정도임을 나타내었다. 분포도와 상관분석 결과는, 소유역에서 토양 함수량 측정을 위한 두 방법들에 있어서 유의한 차이를 나타내지 않았다.

  • PDF

Sentinel-1A/B SAR 센서 기반 고해상도 토양수분 산정 (Estimation of High-Resolution Soil Moisture based on Sentinel-1A/B SAR Sensors)

  • 김상우;이태화;신용철
    • 한국농공학회논문집
    • /
    • 제61권5호
    • /
    • pp.89-99
    • /
    • 2019
  • In this study, we estimated the spatially-distributed soil moisture at the high resolution ($10m{\times}10m$) using the satellite-based Sentinel-1A/B SAR (Synthetic Aperture Radar) sensor images. The Sentinel-1A/B raw data were pre-processed using the SNAP (Sentinel Application Platform) tool provided from ESA (European Space Agency), and then the pre-processed data were converted to the backscatter coefficients. The regression equations were derived based on the relationships between the TDR (Time Domain Reflectometry)-based soil moisture measurements and the converted backscatter coefficients. The TDR measurements from the 51 RDA (Rural Development Administration) monitoring sites were used to derive the regression equations. Then, the soil moisture values were estimated using the derived regression equations with the input data of Sentinel-1A/B based backscatter coefficients. Overall, the soil moisture estimates showed the linear trends compared to the TDR measurements with the high Pearson's correlations (more than 0.7). The Sentinel-1A/B based soil moisture values matched well with the TDR measurements with various land surface conditions (bare soil, crop, forest, and urban), especially for bare soil (R: 0.885~0.910 and RMSE: 3.162~4.609). However, the Mandae-ri (forest) and Taean-eup (urban) sites showed the negative correlations with the TDR measurements. These uncertainties might be due to limitations of soil surface penetration depths of SAR sensors and complicated land surface conditions (artificial constructions near the TDR site) at urban regions. These results may infer that qualities of Sentinel-1A/B based soil moisture products are dependent on land surface conditions. Although uncertainties exist, the Sentinel-1A/B based high-resolution soil moisture products could be useful in various areas (hydrology, agriculture, drought, flood, wild fire, etc.).

Radio Frequency 회로 모듈 BGA(Ball Grid Array) 패키지 (Radio Frequency Circuit Module BGA(Ball Grid Array))

  • 김동영;정태호;최순신;지용
    • 대한전자공학회논문지SD
    • /
    • 제37권1호
    • /
    • pp.8-18
    • /
    • 2000
  • 본 논문은 RF 호로 모듈을 구현하기 위한 방법으로서 BGA(Ball Grid Array) 패키지 구조를 제시하고 그 전기적 변수를 추출하였다. RF 소자의 동작 주파수가 높아지면서 RF 회로를 구성하는 패키지의 전지적 기생 성분들은 무시할 수 없을 정도로 동작회로에 영향을 끼친다. 또한 소형화 이동성을 요구하는 무선 통신 시스템은 그 전기적 특성을 만족시킬 수 있도록 새로운 RF 회로 모듈 구조를 요구한다. RF 회로 모듈 BGA 패키지 구조는 회로 동작의 고속화, 소형화, 짧은 회로 배선 길이, 아날로그와 디지탈 혼성 회로에서 흔히 발생하는 전기적 기생 성분에 의한 잡음 개선등 기존의 구조에 비해 많은 장점을 제공한다. 부품 실장 공정 과정에서도 BGA 패키지 구조는 드릴링을 이용한 구멍 관통 홀 제작이 아닌 순수한 표면 실장 공정만으로 제작될 수 있는 장점을 제시한다. 본 실험은 224MHz에서 동작하는 ITS(Intelligent Transportation System) RF 모튤을 BGA 패키지 구조로 설계 제작하였으며, HP5475A TDR(Time Domain Reflectometry) 장비를 이용하여 3${\times}$3 입${\cdot}$출력단자 구조을 갖는 RF 모튤 BGA 패키지의 전기적 파라메타의 기생성분을 측정하였다. 그 결과 BGA 공납의 자체 캐패시턴스는 68.6fF, 자체 인덕턴스는 1.53nH로써 QFP 패키지 구조의 자체 캐패시턴스 200fF와 자체 인덕턴스 3.24nH와 비교할 때 각각 34%, 47%의 값에 지나지 않음을 볼 수 있었다. HP4396B Network Analyzer의 S11 파라메타 측정에서도 1.55GHz 근방에서 0.26dB의 손실을 보여주어 계산치와 일치함을 보여 주었다. BGA 패키지를 위한 배선 길이도 0.78mm로 짧아져서 RF 회로 모튤을 소형화시킬 수 있었으며, 이는 RF 회로 모듈 구성에서 BGA 패키지 구조를 사용하면 전기적 특성을 개선시킬 수 있음을 보여준 것이다.

  • PDF

휴대용 TDR 함수량계로 측정한 현장 함수비를 이용한 현장 상온 재활용 아스팔트 포장의 수분 감소계수 개발 (Development of Moisture Loss Index Based on Field Moisture Measurement using Portable Time Domain Reflectometer (TDR) for Cold In-place Recycled Pavements)

  • 김용주;이호신;임수혁
    • 한국도로학회논문집
    • /
    • 제13권2호
    • /
    • pp.139-145
    • /
    • 2011
  • 최근 10년간 전세계적으로 아스팔트 포장을 재활용하는 기술이 급속도로 확산되고 있으며 노후 아스팔트 포장을 폼드 아스팔트 또는 유화 아스팔트를 사용하여 현장에서 바로 100% 재활용하는 현장 상온 재생 아스팔트 포장기술이 다양하게 적용되고 있다. 특히, 아이오와 주에서는 교통량이 적은 지방도로에서 기존 포장의 수명을 연장 시켜주는 현장 상온 재생 아스팔트 공법을 많이 적용하고 있다. 일반적으로 현장 상온 재생 아스팔트 포장층은 수분의 침투나 교통하중으로부터 보호하거나 포장설계를 만족시키기 위해 가열 아스팔트 포장으로 덧씌우기를 한다. 일반적으로 현장 상온 재생 아스팔트 포장층 위에 가열 아스팔트 포장으로 덧씌우기 할 시기는 대부분에 감독자들은 일정한 양생기간 또는 최대 함수비에 근거하여 결정하고 있다. 따라서, 본 연구에서는 감독자가 최적에 덧씌우기 아스팔트 포장 시기를 결정할 수 있도록 현장 상온 재생 아스팔트 포장층의 현장 함수비를 간단하게 측정하여 덧씌우기 시기를 결정할 수 있는 수분 감소계수를 개발하는 것이다. 먼저, 현장 상온 재생 아스팔트 포장층의 함수비를 TDR 함수량계를 사용하여 측정하였고 현장 상온 재생 아스팔트 포장이 시공되는 기간 동안에 강우량, 대기온도, 습도, 바람속도 등 기상정보를 수집하였다. 마지막으로 현장 상온 재생 아스팔트 포장의 초기 함수비, 대기온도, 습도, 바람속도를 변수로 하는 수분 감소계수를 개발하였다. 실제 현장 상온 재생 아스팔트 포장에서 측정한 값을 사용하여 개발한 수분 감소계수는 감독자가 연속적으로 현장 상온 재생 아스팔트 포장층의 함수비를 측정하지 않고 최적의 덧씌우기 포장 시점을 결정할 수 있다.

Signal Integrity Analysis of High Speed Interconnects In PCB Embedded with EBG Structures

  • Sindhadevi, M.;Kanagasabai, Malathi;Arun, Henridass;Shrivastav, A. K.
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권1호
    • /
    • pp.175-183
    • /
    • 2016
  • This paper brings out a novel method for reducing Near end and Far end Crosstalk using Electromagnetic Band Gap structures (EBG) in High Speed RF transmission lines. This work becomes useful in high speed closely spaced Printed Circuit Board (PCB) traces connected to multi core processors. By using this method, reduction of −40dB in Near-End Crosstalk (NEXT) and −60 dB in Far End Crosstalk (FEXT) is achieved. The results are validated through experimental measurements. Time domain analysis is performed to validate the signal integrity property of coupled transmission lines.

토양수분량 측정 현황 및 분석 (Study on the Characteristic Analysis of Soil Moisture)

  • 이정훈;장은세;이연길;김상현;정성원
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2016년도 학술발표회
    • /
    • pp.223-223
    • /
    • 2016
  • 수문 순환과 물 수지에 관한 연구는 강수량, 지표유출량, 지하수, 토양수분 및 증발산량 등에 대한 관측이 이루어질 때 실제로 규명될 수 있다. 특히 국내 지형의 대부분을 차지하고 있는 산림 사면에서 토양수분량 측정은 물순환을 이해하는데 중요한 것으로 판단된다. 본 연구는 국토교통부의 기초수문자료 구축사업의 일환으로 수행되고 있으며, 수문자료의 다양화 목적을 가지고 TDR(Time Domain Reflectometry, TDR) 장비를 이용하여 2시간 간격으로 2015년 3월부터 12월까지 측정을 수행하였다. 관측지점은 경기도 파주시 적성면 설마리의 설마천 유역 내에 위치한 감악산내 범륜사 주변 사면과, 충청북도 음성군의 청미천 유역내의 수레의산 산지 사면에서 수행하였다. 관측소에서 측정된 토양수분량 자료는 토양수분량의 시공간적 분포 특성을 파악하기 위해 토양수분량의 통계분석(평균, 표준편차, 변동계수)를 수행하였다. 설마천유역의 설마천 관측소에서는 2015년 강수량이 적어 2014년의 토양수분량 평균값보다 낮게 측정되었다(평균 12.96%, 표준편차 2.2%). 청미천유역의 청미천 관측소에서도 설마천관측소와 마찬가지로 과거보다 적은 강수량이 발생하였지만, 설마천 관측소와는 다르게 안정적인 토양수분 평균값을 유지하는 것은 설마천 관측소 보다 토양층이 발달하고 토성의 점토 함량이 상대적으로 높기 때문으로 보인다. 청미천 관측소의 토양수분량은 평균 24.3%, 표준 편차 1.7%로 나타났다.

  • PDF

산지사면에서의 토양수분량 특성 분석 (Analysis of Soil Moisture Content in Mountain Slopes)

  • 이정훈;이연길;김상현;정성원
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2017년도 학술발표회
    • /
    • pp.234-234
    • /
    • 2017
  • 국내 지형의 대부분을 차지하고 있는 산지 사면에서 토양수분량 측정은 물순환을 이해하는데 중요하다. 본 연구는 국토교통부의 기초수문자료 구축사업의 일환으로 수행되었으며, TDR(Time Domain Reflectometry, TDR)방식의 장비를 이용하여 2시간 간격으로 토양이 동결되어 있는 기간을 제외한 2016년 3월 중순부터 12월초까지 측정을 수행하였다. 관측지점은 설마천 유역 내에 위치한 경기도 파주시 적성면의 감악산 범륜사 주변 산지 사면과, 청미천 유역 내에 위치한 충청북도 음성군 수레의산 산지 사면에 위치하고 있다. 각각의 관측소에서 측정된 토양수분량 자료는 분포 특성을 파악하기 위해 토양수분량의 통계분석(평균, 표준편차)을 수행하였다. 2016년 토양수분량 관측소 운영기간 동안에는 2014년, 2015년보다 많은 강우량이 발생하였다. 또한 강우 패턴이 과거와는 다르게 가을철 많은 강우량이 발생하였다. 설마천 유역에 위치한 설마천 토양수분량 관측소의 경우 2016년 평균토양수분량이 13.7%, 표준편차 6.3%로 2015년(평균 12.9%)보다 큰 특성을 보였다. 청미천 유역에 위치한 청미천 토양수분량 관측소에서도 2016년 평균토양수분량이 24.5%, 표준편차 5.0%로 2015년 (24.3%)보다 증가하였다. 설마천 관측소보다 청미천 관측소의 토양수분량 특성이 크게 나타나는데 이는 청미천 관측소가 설마천 관측소에 비해 유효토심이 깊고 토성의 점토 함량이 상대적으로 높기 때문으로 판단된다.

  • PDF