• Title/Summary/Keyword: Time Synchronization System

Search Result 613, Processing Time 0.022 seconds

A Study of VR Interaction for Non-contact Hair Styling (비대면 헤어 스타일링 재현을 위한 VR 인터렉션 연구)

  • Park, Sungjun;Yoo, Sangwook;Chin, Seongah
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.2
    • /
    • pp.367-372
    • /
    • 2022
  • With the recent advent of the New Normal era, realistic technologies and non-contact technologies are receiving social attention. However, the hair styling field focuses on the direction of the hair itself, individual movements, and modeling, focusing on hair simulation. In order to create an improved practice environment and demand of the times, this study proposed a non-contact hair styling VR system. In the theoretical review, we studied the existing cases of hair cut research. Existing haircut-related research tend to be mainly focused on force-based feedback. Research on the interactive haircut work in the virtual environment as addressed in this paper has not been done yet. VR controllers capable of finger tracking the movements necessary for beauty enable selection, cutting, and rotation of beauty tools, and built a non-contact collaboration environment. As a result, we conducted two experiments for interactive hair cutting in VR. First, it is a haircut operation for synchronization using finger tracking and holding hook animation. We made position correction for accurate motion. Second, it is a real-time interactive cutting operation in a multi-user virtual collaboration environment. This made it possible for instructors and learners to communicate with each other through VR HMD built-in microphones and Photon Voice in non-contact situations.

An accuracy analysis of Cyberknife tumor tracking radiotherapy according to unpredictable change of respiration (예측 불가능한 호흡 변화에 따른 사이버나이프 종양 추적 방사선 치료의 정확도 분석)

  • Seo, jung min;Lee, chang yeol;Huh, hyun do;Kim, wan sun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.157-166
    • /
    • 2015
  • Purpose : Cyber-Knife tumor tracking system, based on the correlation relationship between the position of a tumor which moves in response to the real time respiratory cycle signal and respiration was obtained by the LED marker attached to the outside of the patient, the location of the tumor to predict in advance, the movement of the tumor in synchronization with the therapeutic device to track real-time tumor, is a system for treating. The purpose of this study, in the cyber knife tumor tracking radiation therapy, trying to evaluate the accuracy of tumor tracking radiation therapy system due to the change in the form of unpredictable sudden breathing due to cough and sleep. Materials and Methods : Breathing Log files that were used in the study, based on the Respiratory gating radiotherapy and Cyber-knife tracking radiosurgery breathing Log files of patients who received herein, measured using the Log files in the form of a Sinusoidal pattern and Sudden change pattern. it has been reconstituted as possible. Enter the reconstructed respiratory Log file cyber knife dynamic chest Phantom, so that it is possible to implement a motion due to respiration, add manufacturing the driving apparatus of the existing dynamic chest Phantom, Phantom the form of respiration we have developed a program that can be applied to. Movement of the phantom inside the target (Ball cube target) was driven by the displacement of three sizes of according to the size of the respiratory vertical (Superior-Inferior) direction to the 5 mm, 10 mm, 20 mm. Insert crosses two EBT3 films in phantom inside the target in response to changes in the target movement, the End-to-End (E2E) test provided in Cyber-Knife manufacturer depending on the form of the breathing five times each. It was determined by carrying. Accuracy of tumor tracking system is indicated by the target error by analyzing the inserted film, additional E2E test is analyzed by measuring the correlation error while being advanced. Results : If the target error is a sine curve breathing form, the size of the target of the movement is in response to the 5 mm, 10 mm, 20 mm, respectively, of the average $1.14{\pm}0.13mm$, $1.05{\pm}0.20mm$, with $2.37{\pm}0.17mm$, suddenly for it is variations in breathing, respective average $1.87{\pm}0.19mm$, $2.15{\pm}0.21mm$, and analyzed with $2.44{\pm}0.26mm$. If the correlation error can be defined by the length of the displacement vector in the target track is a sinusoidal breathing mode, the size of the target of the movement in response to 5 mm, 10 mm, 20 mm, respective average $0.84{\pm}0.01mm$, $0.70{\pm}0.13mm$, with $1.63{\pm}0.10mm$, if it is a variant of sudden breathing respective average $0.97{\pm}0.06mm$, $1.44{\pm}0.11mm$, and analyzed with $1.98{\pm}0.10mm$. The larger the correlation error values in both the both the respiratory form, the target error value is large. If the motion size of the target of the sine curve breathing form is greater than or equal to 20 mm, was measured at 1.5 mm or more is a recommendation value of both cyber knife manufacturer of both error value. Conclusion : There is a tendency that the correlation error value between about target error value magnitude of the target motion is large is increased, the error value becomes large in variation of rapid respiration than breathing the form of a sine curve. The more the shape of the breathing large movements regular shape of sine curves target accuracy of the tumor tracking system can be judged to be reduced. Using the algorithm of Cyber-Knife tumor tracking system, when there is a change in the sudden unpredictable respiratory due patient coughing during treatment enforcement is to stop the treatment, it is assumed to carry out the internal target validation process again, it is necessary to readjust the form of respiration. Patients under treatment is determined to be able to improve the treatment of accuracy to induce the observed form of regular breathing and put like to see the goggles monitor capable of the respiratory form of the person.

  • PDF

Possibility of Repeated Use of Elite Donor Cows for Mass Production of OPU-Derived Embryos (OPU 유래 수정란의 대량생산을 위한 고능력 공란우 반복사용 가능성에 관한 연구)

  • Jin, Jong-In;Choi, Byung-Hyun;Kim, Seong-Su;Park, Bun-Young;Lee, Jung-Gyu;Kong, Il-Keun
    • Journal of Embryo Transfer
    • /
    • v.30 no.3
    • /
    • pp.149-159
    • /
    • 2015
  • This study was designed to know the possibility in repeat uses of elite donor cows for getting mass production of OPU-derived embryo production (OPU-IVP). Ultrasound transvaginal ovum pick-up (OPU) performed in 6 Korean native cows was aged 4 to 10 years old. The aspiration of immature oocytes for OPU derived embryo was carried out 2 times per week, and OPU-IVP of $1^{st}$ period was carried out 22~48 sessions from each donors. And the break time for OPU-IVP of $2^{nd}$ period after $1^{st}$ OPU from each donors were 2~25 months. The OPU-IVP of $2^{nd}$ period each donors conducted total 15~65 times for 2~8 months by an ultrasonographic, was guided follicular aspiration system. The average numbers of collected oocytes, grade 1 + grade 2(G1+G2) oocytes and cleavage embryo from $1^{st}$ period OPU-IVP were significantly differences between donors (p<0.05). Total collected oocytes of donor D were significantly higher compared with donors of A, B, C, E and F (average 17.0 per session vs. 11.2, 10.1, 8.5, 10.2 and 9.6; p<0.05) and also oocytes of G1+G2 were significantly higher compared with r A and D and subsequently to donors of B, C, E and F (average 7.9 and 8.5 per session vs. 5.0, 2.7, 6.0 and 1.6; p<0.05). Cleavage rate of donor D was significantly higher compared with donors of A, B, C, E and F (average 13.1 per session vs. 10.1, 9.1, 6.9, 8.9 and 6.7; p<0.05). The average numbers of OPU-IVP for $1^{st}$ period was significantly higher from donors of B, D and E than those from donors of A, C and F (average 6.5, 7.1 and 6.5 per session vs. 3.5, 4.2 and 2.8; p<0.05). The possibility investigation of $2^{nd}$ OPU-IVP was carried out after 2~25 months rest periods from $1^{st}$ period OPU session. Total average numbers of collected oocytes, cleavages and blastocyst development rates were significantly higher from $1^{st}$ period OPU compared with $2^{nd}$ period one (p<0.05). The OPU-IVP efficiency by break for more embryo production from elite cow was analysis comparing without rest of donor A, under 6 months rest period as B and over 6 months rest period as C and then the average numbers of collected oocytes, cleavages and blastocysts were significantly higher from A group (11.8, 9.5 and 5.2 per session) than those from B and C groups (7.9, 6.2 and 2.6 vs. 9.2, 7.5 and 3.9, p<0.05), and also C group was significantly higher than B group. In conclusion, $1^{st}$ period OPU-IVP was more efficient compared with $2^{nd}$ period repeated uses of donor, and the break times for additional production of embryo on donor were needed more than over 6 months after $1^{st}$ period OPU-IVP. This repeating uses of elite donor cows given more emphasis for getting the opportunity on mass production of elite cow OPU-IVP embryo should be increased G1+G2 possibility of genetic improvement of livestock within short period.