• Title/Summary/Keyword: Time Domain Response

Search Result 827, Processing Time 0.026 seconds

Seismic behavior of steel cabinets considering nonlinear connections and site-response effects

  • Tran, Thanh-Tuan;Nguyen, Phu-Cuong;So, Gihwan;Kim, Dookie
    • Steel and Composite Structures
    • /
    • v.36 no.1
    • /
    • pp.17-29
    • /
    • 2020
  • This paper presents experimental and numerical studies on the seismic responses of the steel cabinet facility considering the nonlinear behavior of connections and site-response effects. Three finite element (FE) models with differences of type and number of connections between steel plates and frame members have been developed to demonstrate adequately dynamic responses of structures. The screw connections with the bilinear force-deformation relationship are proposed to represent the inelastic behavior of the cabinet. The experiment is carried out to provide a verification with improved FE models. It shows that the natural frequencies of the cabinet are sensitive to the plate and frame connectors. The screw connections reduce the free vibration compared to the weld one, with decreased values of 2.82% and 4.87% corresponding to front-to-back and side-to-side directions. Additionally, the seismic responses are investigated for various geological configurations. Input time histories are generated so that their response spectrums are compatible with a required response spectrum via the time-domain spectral matching. The results indicate that both site effects and nonlinear behavior of connections affect greatly on the seismic response of structures.

Analysis of Transient Response of an Engine to Throttle Tip-in/Tip-out (차량 감/가속시의 엔진의 동적 응답 해석)

  • 고강호
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.4
    • /
    • pp.122-128
    • /
    • 2002
  • In this paper dynamic responses of an engine, which is supported by hydraulic mount, to throttle tip-in/Tip out are analyzed. Because the hydraulic mounts have non-linearity that the characteristics of stiffness and damping vary with frequencies, it is difficult to analyze the dynamic behavior of an engine using general integral algorithms. Convolution integral and relationship between unit impulse response functions and frequency response functions are therefore used to simulate the transient behaviors of an engine indirectly. In time domain, impulse response functions are calculated by two-side discrete inverse courier transform of frequency response function achieved by laplace transform of equations of motion. Considering the fact that the shapes of behavior of an engine simulated by the proposed method are in good agreement with test results, it is confirmed that the proposed method is very effective for the analysis of transient response to throttle tip-in/out of an engine with hydraulic mounts.

Dynamic Analysis of Engine Response to Throttle Tip-in/Tip-out (Tip-in/Tip-out 시의 엔진의 동적 거동 해석)

  • Ko, Kang-Ho;Kook, Hyung-Seok
    • Proceedings of the KSME Conference
    • /
    • 2001.06b
    • /
    • pp.540-545
    • /
    • 2001
  • In this paper dynamic responses of an engine, which is supported by hydraulic mount, to throttle tip-in/tip out are analyzed. Because the hydraulic mounts have non-linearity which the characteristics of stiffness and damping vary with frequencies, it is difficult to analyze the dynamic behavior of an engine using general integral algorithms. Convolution integrals and relationships between unit impulse response functions and frequency response functions are therefore used to simulate the transient behavior of an engine indirectly. In time domain, impulse response functions are calculated by two-side discrete inverse Fourier transform of frequency response function achieved by Laplace transform of equations of motion. Considering the fact that the shapes of behavior of an engine simulated by the proposed method are in good agreement with test results, it is confirmed that the proposed method is very effective for the analysis of transient response to throttle tip-in/out of an engine with hydraulic mounts.

  • PDF

Lowering Simulation using Floating Crane in Waves (파랑 중 해상 크레인의 하강 작업 수치 시뮬레이션)

  • Nam, Bo-Woo;Hong, Sa-Young;Kim, Byoung-Wan;Lee, Dong-Yeop
    • Journal of Ocean Engineering and Technology
    • /
    • v.26 no.1
    • /
    • pp.17-26
    • /
    • 2012
  • A coupled analysis of a floating crane barge with a crane wire and hanging structure is carried out in thetime domain. The motion analysis of the crane barge is based on the floating multi-body dynamics, and thecrane wire is modeled as a simple spring tension. The hanging structure is assumed to be a rigid body with 3 degree-of-freedom translational motion. In this study, numerical simulations were conducted at three different stages. First, the developed code was validated by comparing the time-domain motion response of a crane barge with the frequency-domain results. Then, a coupled analysis of a crane barge and simple structure hanging by the crane wire was performed using the present scheme. The motion response and wire tension from the present calculations are compared with the results of OrcaFlex. The agreement between the two sets of results isfairly good. Last, lowering simulations in regular and irregular waves were conducted considering buoyancy changes in the hanging structure. The effects of the wave conditions, structure's weight, wire length, and lowering speed on the wire tension are considered.

Study on Controller Design of AC Servo Permanent Magnet Synchronous Motor by Matrix Converter : Speed Controller (매트릭스 컨버터에 의한 AC 서보 영구자석형 동기전동기의 제어기 설계에 대한 고찰 : 속도제어기)

  • Jeong, Chung-Il;Lee, Sang-Cheol;Mo, Dong-Yeong;Choi, Chang-Young;Kim, Tae-Woong;Park, Gwi-Geun
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.106-108
    • /
    • 2008
  • This paper deals with the design for speed controller to drive PMSM by matrix converter without DC-link circuit as the power conversion system of AC servo motor drive. To design the speed controller of PMSM drive, the closed-loop transfer function of speed controller is calculated and then the frequency-domain response characteristics are analyzed by bode plot using Matlab. Based on the results by bode plot, the speed control gains are determined. As the real effects of controller designed in the frequency-domain display in the time-domain, the performance of speed controller is confirmed by the step response of speed controller. The design examples are shown and its validity of the design method mentioned in the paper is verified through PSIM simulation.

  • PDF

Vibration Control for Tower of Suspension Bridge under Turbulence using TMD (난류하에서의 TMD에 의한 현수교 주탑의 진동제어)

  • Kim, Ki Du;Hwang, Yoon Koog;Byun, Yun Joo;Chang, Dong Il
    • Journal of Korean Society of Steel Construction
    • /
    • v.9 no.2 s.31
    • /
    • pp.181-191
    • /
    • 1997
  • Before cables are constructed, tower of suspension bridge is behaved as a cantilever type. Buffeting occured by unsteady loading of the tower due to velocity fluctuation in the oncoming flow has a wind velocity consistent with fundamental frequency of the tower and may give rise to large response by the tower resonance. To reduce the dynamic response by buffeting, the behavior of tower with TMD(Tuned Mass Damper) has studied using finite element method in time domain. The buffeting was obtained by transforming the velocity spectrum in frequency domain to random variable in certain time domain. The most probable maximum displacement which can be occured during the time interval was obtained using peak factor. The optimum location for TMD installation and TMD specification were decided by parametric study. Also, the effect of vibration control about various wind velocity was studied by the TMD which has optimum specification and location.

  • PDF

광 경화성 단분자를 이용한 수직 배향 액정 표시 소자의 노광 조건에 따른 표면 안정화의 연구

  • Kim, Hye-Yeong;Kim, Dae-Hyeon;Gwon, Dong-Won;Kim, U-Il;Jo, In-Yeong;Kim, Seong-Min;Lee, Seung-Hui;Jeong, Yeon-Hak;Ryu, Jae-Jin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.187-187
    • /
    • 2009
  • The PVA(patterned vertical alignment) mode has a excellent dark state at normal direction. but they has a disclination area at divided domain region at voltage on state. so this disclination make a slow response time and decrease transmittance. To overcome this problem, we research about polymer stabilized vertical alignment (PS-VA) method which was using the UV curable reactive mesogen. According to our research, UV exposure condition which was UV dosage condition effected to rising time and decay time and also threshold voltage.

  • PDF

Transient Response of Optically-Controlled Microwave Pulse through Open-Ended Microstrip Lines

  • Kim, Yong K.;Kim, Jin-Su;Park, Kyoung-Su
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.4C no.5
    • /
    • pp.236-240
    • /
    • 2004
  • In this paper we examine the reflection characteristics of dielectric microstrip lines with open-ended termination containing an optically induced plasma region, which are analyzed by the assumption that the plasma is distributed homogeneously in laser illumination. The characteristics impedances resulting from the presence of plasma are evaluated by the transmission line model. To estimate theoretically the characteristic response of identical systems in the time domain, the Fourier transformation method is evaluated. The reflection characteristics of time and frequency response in microwave systems have been calculated using an equivalent circuit model.

New Learning Hybrid Model for Room Impulse Response Functions (새로운 학습 하이브리드 실내 충격 응답 모델)

  • Shin, Min-Cheol;Wang, Se-Myung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.3
    • /
    • pp.361-367
    • /
    • 2008
  • Many trials have been used to model room impulse responses, all attempting to provide efficient representations of room acoustics. The traditional model designs for room impulse response seem to fail in accuracy, controllability, or computational efficiency. In the time domain, room impulse responses are generally considered as combination of the three Parts having different acoustic characteristics, initial time delay, early reflection, and late reverberation. This paper introduces new learning hybrid model for room impulse responses. In this proposed model, those three parts are modeled using different models with learning algorithms that determine the boundary of each model in the hybrid model. By the simulation with measured room impulse responses, the performance of proposed model shows the best efficiency in views of computational burden and modeling error.

Analysis of Hertzian Contact using Fast Fourier Transform (FFT를 이용한 Hertz Contact 해석)

  • 구영필;조용주
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1998.04a
    • /
    • pp.131-138
    • /
    • 1998
  • In this study, a numerical procedure to solve a contact problem has been developed. The procedure takes the advantage of signal processing technique in frequency domain to achieve the shorter computer processing time. The Boussinesq's equation was adopted as the response function. This procedure is applicable to the non-periodic surface profile as well as the periodic one. The validity of this procedure has been established by comparing the numerical results with the exact solutions. The effectiveness of this procedure is lied on the shorter computing time than any other contact analysis algorithm.

  • PDF