• 제목/요약/키워드: Time Correlation Function

검색결과 718건 처리시간 0.028초

Development of Natural Antioxidants and Whitening Agents for Cosmeceuticals

  • Kim, Jong-Pyung
    • 한국응용약물학회:학술대회논문집
    • /
    • 한국응용약물학회 2007년도 Proceedings of The Convention
    • /
    • pp.79-92
    • /
    • 2007
  • Oxidative stress have known to be a risk factor for the degenerative processes and closely related to a lot of diseases. It is well established that antioxidants are good in protection and therapeutic means against oxidative damage. There is increasing interest in natural antioxidants and many natural antioxidants have been found and utilized as the possible protection for various diseases and skin aging. We have screened natural antioxidant agents for cosmeceuticals, nutraceuticals, and drugs as therapeutic and preventive means against oxidative stress, and have developed a number of novel antioxidants from various natural sources. A novel melanin synthesis inhibitor, Melanocin A, isolated from the metabolite of a fungal strain Eupenicillium shearii F80695 inhibited mushroom tyrosinase and melanin biosynthesis of B16 melanoma cells with $IC_{50}$ value of 9.0 nM and MIC value of $0.9\;{\mu}M$, respectively. Melanocin A also exhibited potent antioxidant activity by scavenging of DPPH and superoxide anion radicals. UV was found to increase the level of hydrogen peroxides and other reactive oxygen species (ROS) in skin tissues. This increase in ROS may not only alter the structure and function of many genes and proteins directly but may also modulate their expressions through signal transduction pathways and, ultimately, lead to skin damage. We investigated the effect of Melanocin A on UV-induced premature skin aging. Firstly, the effect of Melanocin A on UV-induced matrix metalloproteinase (MMP)-9 expression in an immortalized human keratinocyte cell line, HaCaT in vitro was investigated. Acute UV irradiation induced MMP-9 expression at both the mRNA and protein levels and Melanocin A suppressed this expression in a dose-dependent manner. We then investigated UV-induced skin changes in hairless mice in vivo by Melanocin A. Chronic exposure of hairless mouse dorsal skin to UV increased skin thickness and induced wrinkle formation and the gelatinase activities of MMP-2 and MMP-9. Moreover, Melanocin A significantly suppressed UV-induced morphologic skin changes and MMP-2 and MMP-9 expression. These results show that Melanocin A can prevent the harmful effects of UV that lead to skin aging. Therefore, we suggest that Melanocin A should be viewed as a potential therapeutic agent for preventing and/or treating premature skin aging. Terrein is a bioactive fungal metabolite isolated from Penicillium species. Terrein has a relatively simple structure and can be easily synthesized. However, the biologic effects of terrein are comparatively unknown. We found for the first time that terrein potently inhibit melanin production in melanocytes and has a strong hypopigmentary effect in a spontaneously immortalized mouse melanocyte cell line, Mel-Ab. Treatment of Mel-Ab cells with terrein (10-100 mM) for 4 days significantly reduced melanin levels in a dose-dependent manner. In addition, terrein at the same concentration also reduced tyrosinase activity. We then investigated whether terrein influences the extracellular signal-regulated protein kinase (ERK) pathway and the expression of microphthalmia-associated transcription factor (MITF), which is required for tyrosinase expression. Terrein was found to induce sustained ERK activation and MITF down-regulation, and luciferase assays showed that terrein inhibits MITF promoter activity in a dose-dependent manner. To elucidate the correlation between ERK pathway activation and a decreased MITF transcriptional level, PD98059, a specific inhibitor of the ERK pathway, was applied before terrain treatment and found to abrogate the terrein-induced MITF attenuation. Terrein also reduced the tyrosinase protein level for at least 72 h. These results suggest that terrain reduces melanin synthesis by reducing tyrosinase production via ERK activation, and that this is followed by MITF down-regulation.

  • PDF

분당 차병원에서 출생한 신생아 혈압치 비교 (Blood Pressure of Healthy Newborns in the First Week of Life)

  • 이정선;박신이;박혜원;김세현;하태선;이준호
    • Childhood Kidney Diseases
    • /
    • 제9권1호
    • /
    • pp.8-14
    • /
    • 2005
  • 목 적 : 정상 만삭아의 혈압을 측정하여 우리나라 신생아의 평균혈압을 알고 기존의 참고치로 사용되고 있는 외국 자료와 비교하고 신생아 고혈압 선별에 도움이 되고자 이 연구를 시행하였다. 방 법 : 2003년 5월부터 2004년 1월까지 포천 중문의과대학교 분당차병원에서 출생한 건강한 신생아 중 남아(194명), 여아(189명) 총 383명을 대상으로 진동식 자동 혈압계로 1-3회 측정하여 총 773회를 혈압치를 수집하였다. 전체 대상아의 평균 혈압과 성별 간, 분만 방법 간, 이상 병력의 유무(산모 질환, 주산기 과거력이나 단일제대 동맥 중 하나라도 있는 경우)에 따른 혈압의 차이를 구하고 출생체중과 재태기간에 따른 수축기 혈압의 변화를 알아보았다. 결 과 : 전체 대상아 383명의 수축기 혈압은 70.8$\pm$10.9 mmHg, 이완기 혈압은 43.4$\pm$8.0mmHg 이었다. 성별 간 비교에서는 남아의 수축기 혈압은 71.1$\pm$11.4 mmHg, 이완기 혈압은 43.6$\pm$8.2 mmHg, 여아의 수축기 혈압은 70.5$\pm$10.3 mmHg, 이완기 혈압은 43.2$\pm$7.7 mmHg로 성별 간 혈압의 통계학적 유의한 차이는 없었다.(p>0.05). 분만 방법의 차이에 따른 혈압의 비교에서는 혈압 측정한 날을 수정하여 비교한 결과 제왕절개를 한 군과 질식분만을 한 군 간의 혈압은 통계학적으로 유의한 차이가 없었다(P>0.05).이상 병력의 유무에 따른 혈압의 비교로는 이상 병력이 있는 군은 72명으로 수축기 혈압이 71.5$\pm$12.3 mmHg, 이완기 혈압이 43.4$\pm$8.5 mmHg이었으며, 이상 병력이 없는 311명의 신생아는 수축기 혈압이 70.6$\pm$10.5 mmHg, 이완기 혈압이 43.4$\pm$7.9 mmHg로 두 군 간 통계학적 유의한 차이는 없었다(P>0.05). 또한 출생체중과 재태기간이 증가할수록 수축기 혈압은 상승하였다.(r=0.1420, 0.0360)결 론 : 본 연구에서 건강한 신생아 383명을 대상으로 혈압을 측정한 결과 기존의 외국 데이터와 유사하였고, 이를 토대로 신생아 고혈압의 조기선별하고 치료를 시작하여 그 주요 원인이 되는 신질환 합병증의 예방과 신기능의 유지에도움이 되고자 한다.

  • PDF

소아의 열성경련에 날씨가 미치는 영향 (Impact of Weather on Prevalence of Febrile Seizures in Children)

  • 우정희;오석빈;임정혁;변정혜;은백린
    • 대한소아신경학회지
    • /
    • 제26권4호
    • /
    • pp.227-232
    • /
    • 2018
  • 목적: 열성 경련은 생후 6개월부터 만 5세 사이 발생하는 가장 흔한 유형의 경련으로 직계 가족에서 가족력이 존재할 때 더 발생률이 높다. 열성 경련의 발생률과 외부 환경과의 영향에 대하여 아직 정확히 알려진 바가 없다. 본 연구는 열성 경련의 발생과 날씨의 연관성을 파악하기 위해 시행되었다. 방법: 본 연구는 건강보험심사평가원 자료를 바탕으로 진행되었다. 2009년 1월부터 2013년 12월까지 서울 소재 병원에서 첫 번째 열성경련으로 내원하여 진단받은 29,240명의 환아들을 대상으로 시행하였다. 동일기간 동안 기상청에서 수집한 4개의 기상인자(해면기압, 강수량, 습도, 기온) 들과의 연관성을 알아보았다. 포아송 일반화 부가모형(Poisson Generalized Addictive Model)을 이용하였다. 바이러스 감염이 열성 경련의 발생률에 기여하는 영향도 논의되었다. 결과: 강수량은 두 가지 그룹(5 mm 미만과 5 mm 이상)으로 나뉘어 분석되었다. 포아송 분석 결과 열성경련의 발생률은 강수량이 적을수록 증가하였다. 해면기압, 습도, 기온 등 3가지 변수들을 분석하는데 있어서 평활 함수가 사용되었고 그 결과 열성 경련 발생률은 해면기압이 낮을수록, 습도가 낮을수록 증가하였고, 기온이 $-7--1^{\circ}C$$18-21^{\circ}C$ 일 때 높았다. 결론: 본 연구는 열성경련과 날씨와의 연관성을 파악하기 위하여 시행되었고, 그 결과 강수량이 적을수록, 해면기압이 낮을수록, 습도가 낮을수록 열성경련의 발생률이 증가하였다. 그러므로, 날씨는 열성경련 발생에 영향을 주는 요인 중 하나이다.

풍납토성 기와건물지의 성격과 위상 (Characteristics and Status of Roof Tile Buildings of Pungnaptoseong Fortress)

  • 소재윤
    • 헤리티지:역사와 과학
    • /
    • 제56권3호
    • /
    • pp.46-59
    • /
    • 2023
  • 풍납토성에서는 미래마을부지 마-1호 건물지를 비롯하여 백제 지상식 건물지가 여럿 확인되었다. 그러나 기와가 건물지와 직접적으로 관련되어 출토된 건물지는 마-1호 건물지가 유일하다. 마-1호 건물지와 비견되는 마-2호 건물지와 라-1호·2호 건물지 등의 경우에는 적심시설 및 건물 구조로 보건데 지붕에 기와가 올라갔을 가능성이 매우 높은 건물지라 하겠다. 비록 반지하식의 수혈건물지일지라도 내외부 기와 출토상황상 가-30호 수혈건물지나 현대아파트부지 가-5호 주거지 혹은 지상식에 가까운 경당지구 44호 유구처럼 지붕에 전면 즙와가 아닌 부분즙와의 형태로 기와건물이 조성되었을 수도 있다. 지붕에 기와를 사용한 초기 배경에는 여러 이유가 있을 수 있으나 주요한 배경으로는 건물의 위세적 기능이 우선적으로 고려되었을 것으로 여겨진다. 중국과 일본에서 궁전, 사찰, 예제성 건축물(禮制性 建築物) 등 국가적으로 중요한 건물에 기와를 사용하기 시작한 사례로 보아, 백제도 중앙집권화된 시점부터는 적극 사용하였을 것으로 추정된다. 백제 초기 기와건물은 대형화된 건물을 염두에 두고 화재예방과 구조적 안정성을 고려한 결과, 초보적 주거 건축기술에서 고도화된 공공 건축기술로의 변화가 뒤따라오게 된 것으로 여겨진다. 특히 미래 마-1호 건물지는 고대(高臺)나 지하초석과 같은 구조적인 특징상 국내에 유사사례를 찾아보기 힘들고, 오히려 중국과 일본에서 유사 기술을 사용한 중요 건축물을 찾아볼 수 있다. 중국에서는 주로 장안성 등 궁전 주변에 조성된 예제성 건축물에서 유사 건축기술을 발견할 수 있었다. 이를 토대로 보면 마-1호 건물지 등 현재까지 발견된 기와 건물지는 예제성 건축물 성격과 매우 관련 있어 보이며, 라-1호·2호 건물지와 같은 지상식 건물은 국영 창고와 관련된 중요 시설물로 공공시설물과 연계되어 백제 초기의 도성구조와 관련하여 많은 시사점을 주고 있다.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

소아의 만성 B형 간염: 새로운 병리조직학적 분류와 임상 소견의 상관 분석 (Chronic HBV Infection in Children: The histopathologic classification and its correlation with clinical findings)

  • 이선영;고재성;김종재;장자준;서정기
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • 제1권1호
    • /
    • pp.56-78
    • /
    • 1998
  • 연구목적: 만성 B형 간염의 간조직 소견은 진단 및 예후의 평가 뿐아니라 치료여부의 결정 및 치료효과의 평가를 위해서 중요하고, 이는 좀 더 객관적, 구체적, 포괄적으로 새롭게 분류할 필요성이 있다. 우리나라 소아의 만성 B형 간염의 빈도는 높을 것으로 추정되는데 아직 이에 대한 병리조직학적 고찰은 거의 없는 상태이다. 이에 저자들은 점수로 평가한 최근의 반정량적 분류 방법(Ludwig 분류법)을 전통적으로 이용되어온 De Groute의 분류법과 비교하여 연관성을 밝히고, 반정량적 분류법이 좀 더 객관적으로 예후를 예견하고 형태학적 변화를 감시하는 유용한 방법임을 소개하고자 하였다. 대상 및 방법: 서울대학교병원 소아과에 입원하여, 간조직 생검을 받은 만성 B형 간염 환아 99명을 대상으로 병리조직 소견과 병록지 고찰을 시행하였다. B형 간염 표식자로는 HBsAg, anti-HBs, HBeAg, anti-HBe, anti-HBc(IgG, IgM), HDV를 방사면역측정(radioimmunoassay)을 이용하여 검사하였다. 간생검조직은 전통적인 De Groute의 병리조직학적 분류법과 병리조직학적 변화를 문맥강 및 문맥강 주변의 염증(Portal/Periportal activity), 간소엽 내 염증(Lobular activity), 섬유화(Fibrosis)로 나누어 각각의 정도를 0에서 4로 점수화(Numerical scoring)한 Ludwig의 체계에 따라 분류하였다. 두가지 분류법 간의 연관성과, 병리조직 소견에 따른 빈도, 연령 및 성별 분포, 임상적 특징, 생화학적 및 혈청학적 검사 소견을 비교 조사하였다. 또한 간세포암 5례는 따로 분류하여 임상적 고찰을 시행하였다. 결 과: 1) 총 99례 중 남아 83례, 여아 16례였고, 연령별 분포는 1년 5개월에서 16년 4개월까지였으며, 평균연령은 9.4세였다. 병리조직형별 연령 및 성별분포에는 차이가 없었다. 2) 병리조직형별 분포는 정상 조직 소견 2례, 만성 소엽성 간염 2례, 만성 지속성 간염 22례, 경도 만성 활동성 간염 40례, 중등도 만성 활동성 간염 19례, 고도 만성 활동성 간염 1례, 간경변을 동반한 만성 활동성 간염 7례, 간경변증 1례, 간세포암 5례였다. 두가지 분류법은 높은 연관성을 보였으나 간경화의 경우는 연관성이 떨어져서, 간조직내 염증과 섬유화는 따로 분리하여 평가하거나, 섬유화의 중량이 필요함을 알 수 있었다. 3) 간세포암을 제외한 94례 중 66례(70%)가 신체검사에서 우연히 발견된 경우였으며, 2례는 전신 부종이 주소로서 B형 간염과 관련된 막성 사구체 신염이 동반되어 있었다. 그 외는 비특이적인 간염증상을 주소로 내원하여 진단되었다. 내원시 임상 증상으로는 이피로성, 식욕부진, 오심, 구토, 복통, 복부팽만, 체중감소, 발열, 진한 소변색, 황달, 비출혈, 부종, 혈뇨 등이 있었고, 이학적 소견으로는 간장비대, 비장비대, 우측 상복부통이 있었다. 병리조직형별 임상증상, 이학적 소견 및 그 빈도에는 차이가 없었다. 4) 총 99례 중 가족력상 어머니에 B형 간염의 병력이 있는 경우가 54례, 아버지가 12례, 형제들의 경우가 25례 있었으며, 그 외의 동거 가족에서 가족력이 있는 경우는 17례 있었고, 가족력이 없는 경우는 28례였다. 가족 중 간경화가 있는 경우는 9례였고, 간세포암도 2례에서 있었다. 어머니가 만성 활동성 간염으로 사망한 례가 1례 있었고, 형제가 전격성 간염으로 사망한 경우도 1례 있었다. 병리조직형별 가족력의 차이는 없었다. 5) 간기능 검사소견을 보면, AST와 ALT의 평균은 각각 $151{\pm}158$ U/L, $215{\pm}221$ U/L이고, 병리조직형별로는 조직 염증소견이 심할수록 유의하게 높은 것을 알 수 있었다. 그러나 병리조직형별로 중복되는 부분이 많아 AST, ALT치로 조직형을 예측하는 것은 어려웠다. Ludwig의 분류와 간기능 검사치와의 관계를 보면, 혈청 알부민은 섬유화가 진행할수록 유의하게 감소하는 것을 관찰할 수 있었고, ALT, AST는 간조직내 염증 및 섬유화가 심할수록 유의하게 증가하는 것을 관찰하였다. 6) Prothrombin time은 조직형이 심할수록 유의하게 길어졌고, 특히 간경화가 진행될수록 나빠지는 것을 관찰할 수 있었다. APTT(activated partial thromboplastin time)도 조직형이 심할수록 길어지는 것을 관찰할 수 있었으나, 통계적 유의성은 없었다. 반정량적 방법에 의한 분류와의 관계를 보면, Prothrombin time과 APTT는 간조직내 염증 및 섬유화가 심할수록 길어지는 것을 관찰하였으나, 통계적 유의성은 없었다. 7) IgM anti-HBc는 검사가 이루어진 80명 중 1명에서만 양성이었고, HDV는 검사가 이루어진 83명 중 양성인 경우는 한 례도 없었다. HBeAg은 간생검 당시 81례에서 양성이였고, 이 후 평균 $41.8{\pm}31.3$개월간의 추적 중에 HBeAg 음전을 보인 경우는 50례가 있었고, 1년 음전율은 37%였다. 병리조직형별로는 조직형이 심할수록 음전시까지의 기간이 짧은 것을 관찰할 수 있었다. 8) 간세포암 5례의 남녀 분포는 남아 4례, 여아 1례이고, 평균연령은 $10.4{\pm}3.1$세(7세~13세 6개월)였다. 모두에서 HBsAg양성, HBeAb양성과 어머니의 만성 B형 간염의 가족력이 있었다. 간세포암 주변 조직 소견은 1례를 제외하고는 모두에서 간경화의 소견을 보였다. 추적 중 혈청 AFP의 증가로 조기발견된 1례는 종양절제술 후 항암요법으로 추적 중에 있고, 그 외에는 모두 수술 후 항암요법 혹은 방사선요법을 병행하여 시행했으나 사망하였다. 결 론: 만성 B형 간염의 간손상 정도는 임상증상이나 생화학적 검사소견으로 평가할 수 없었고, 간조직검사에 의한 병리조직학적 분류가 필요하였다. 이는 De Groute의 분류와 잘 연관되는 반정량적 Ludwig 방법에 의해 좀 더 포괄적, 구체적, 객관적으로 분류할 수 있었고, 후자는 예후를 예견하고, 형태학적 변화를 감시하며, 통계적으로 분석하는 데 유용한 방법임을 시사하였다.

  • PDF

삼림환경인자(森林環境因子)에 의한 굴참나무임분(林分)의 생산력추정(生産力推定) (Estimation of Productivity for Quercus variabilis Stand by Forest Environmental Factors)

  • 이동섭;정영관
    • 한국산림과학회지
    • /
    • 제75권1호
    • /
    • pp.1-18
    • /
    • 1986
  • 본(本) 연구(硏究)는 굴참나무의 생장인자(生長因子) (흉고직경(胸高直徑), 수고(樹高), 흉고단면적(胸高斷面績) 및 간재적(幹材積))와 삼림환경(森林環境) 및 토양(土壤)의 이화학적(理化學的) 인자(因子)와의 관계(關係)를 분석(分析)하여 임지(林地)의 생산력(生産力)을 추정(推定)하고, 적지선정(適地選定) 기준(基準)을 설정(設定)하는데 그 목적(目的)이 있다. 이 때 고려(考慮)된 인자(因子)는 삼림환경인자(森林環境因子)로 령급(齡級) 외(外) 19개(個) 토양(土壤)의 이화학적(理化學的) 인자(因子)로 토양산도(土壤酸度) 외(外) 11개(個), 총(總) 32개(個) 인자(因子)이다. 경북(慶北)과 충북지방(忠北地方)에서 선정(選定)된 이들 생장인자(生長因子)와 삼림환경인자(森林環境因子)는 99개(個)의 표준지(標準地)를 대상(對象)으로 조사(調査)되었다. 여기에서 채택(採擇)된 인자(因子)는 이산변수(離散變數)와 연속변수(連續變數)이다. 각각의 인자(因子)를 3~4개(個)의 계급(階級)으로 분류(分類)하여, 총(總) 110개(個)의 계급(階級)으로 구분(區分)하였다. 그리고 각 계급(階級)을 별개(別個)의 독립변수(獨立變數)로 하였다. 즉 이는 의사변수(擬似變數)(dummy variable)로 하여 그의 값을 1 혹은 0으로 놓았다. 각 인자(因子)의 첫 계급(階級)은 통계학적(統計學的) 고려(考慮) 때문에 정규방정식(正規方程式)에서 제외(除外)시켰다. 먼저 4개(個)의 굴참나무 생장인자(生長因子)와 110개(個)의 계급(階級)과의 관계(關係)를 회귀분석(回歸分析)하였다. 다음으로 4개(個)의 생장인자(生長因子)와 32개(個)의 독립변수(獨立變數)간의 편상관계수(偏相關係數)를 계산(計算)하였다. 마지막으로 계급간(階級間)의 범위(範圍)를 구(求)하기 위하여 상대점수(相對點數)를 추정(推定)하였다. 이와 같이 통계분석(統計分析)한 결과(結果)를 요약(要約)하면 다음과 같다. 1) 임목생장인자(林木生長因子)와 삼림환경인자(森林環境因子)와의 관계(關係)를 분석(分析)한 결과(結果), 수고(樹高)를 종속변수(從屬變數)로 하는 것이 추정율(推定率)이 가장 높았다. 그러므로 생장인자(生長因子) 중(中) 수고(樹高)를 임지생산력(林地生産力)의 추정기준(推定基準)으로 하는 것이 효율적(効率的)이라 사료(思料)된다. 2) 입목지(立木地)의 생산력(生産力)은 전체(全體) 삼림환경인자(森林環境因子)에 의하여, 그리고 무입목지(無立木地)는 토양(土壤)의 이화학적(理化學的) 인자(因子)에 의하여 추정(推定)할 수 있다. 3) 전체(全體)의 임목생장인자(林木生長因子)에 공통(共通)으로 크게 관여(關與)하는 인자(因子)는 령급(齡級), 유효토탐(有効土探), 임목밀도(林木密度), 모암(母岩), 위도(緯度), 토양습도(土壤濕度) 등으로서, 이들 인자(因子)의 양부(良否)가 곧 적지적수(適地適樹)의 기준(基準)이 될 수 있다. 4) 임목생장(林木生長)에 대한 계급간(階級間)의 상대점수차(相對點數差)가 공통(共通)으로 큰 인자(因子)는 모암(母岩), 위도(緯度), 전질소함량(全窒素含量), 령급(齡級), 유효토탐(有効土探), 토양습도(土壤濕度), 유기질함량(有機質含量) 등으로서 이들 인자(因子)의 계급(階級)에 따라 적지적수(適地適樹)를 선정(選定)하여야 할 것으로 사료(思料)된다.

  • PDF