• Title/Summary/Keyword: Tight rope technique

Search Result 9, Processing Time 0.023 seconds

Coracoclavicular Ligament Augmentation Using TightRope® for Acute Acromioclavicular Joint Dislocation : Surgical Technique and Preliminary Results (TightRope®를 이용한 급성 견봉 쇄골 관절 탈구의 치료 : 수술 술기 및 예비 보고)

  • Cho, Chul-Hyun;Sohn, Sung-Won;Kang, Chul-Hyung;Oh, Geon-Myeoung
    • Clinics in Shoulder and Elbow
    • /
    • v.11 no.2
    • /
    • pp.165-171
    • /
    • 2008
  • Purpose: The purpose of this study was to introduce a new surgical technique and to evaluate the preliminary results after operative treatment with using TightRope$^{(R)}$ for treating acute acromioclavicular joint dislocation. Material and Methods: We studies 10 patients who were followed up for more than 6 months after operative treatment with using an TightRope$^{(R)}$. A longitudinal incision approximately 4cm in length was made from 1cm medial to the acromioclavicular joint to the coracoid process, and then coracocalvicular ligament augmentation using TightRope$^{(R)}$ was done after splitting the deltoid. For postoperative stability, two 1.6 mm Kirschner wires were inserted temporarily across the acromioclavicular joint in all cases. The radiologic results on the serial plain radiographs and the clinical results according to the UCLA score were analyzed. Results: Radiologically, 7 cases showed anatomical reduction, 2 cases showed a slightly loss of reduction and 1 case showed partial loss of reduction. Clinically, 6 cases were excellent, 3 cases were good and 1 case was fair. Conclusion: Coracoclavicular ligament augmentation using TightRope$^{(R)}$ for treating acute acromioclavicular joint dislocation is a minimally invasive, safe procedure that provides satisfactory radiologic and clinical preliminary results. Yet the long-term results have to be analyzed to determine the final results of this procedure.

Lisfranc Injury Repair with the TightRope$^{TM}$ Device (A Case Report) (TightRope$^{TM}$ Device를 이용한 족근 중족 관절 손상의 치료(1예 보고))

  • Cho, Jae-Ho;Oh, In-Suk
    • Journal of Korean Foot and Ankle Society
    • /
    • v.15 no.4
    • /
    • pp.243-246
    • /
    • 2011
  • Lisfranc injury is complex and difficult to treat. Making the correct diagnosis and achieving an anatomical reduction are important factors in regard to achieving a favorable outcome with this injury. We describe a new technique that we have found to be useful for stabilizing Lisfranc injury. This method is relatively fast and simple, and it provides non-rigid fixation. Also, it eliminates the need for implant removal. To date, we have achieved predictable results for stabilizing and treating this injury with the use of a $TightRope^{TM}$ Device, instead of traditional interfragmental screw fixation. In this report, we describe a case in which this method was used with satisfactory short-term results.

Clinical Evaluation of TightRope Cranial Cruciate Ligament Technique for Treatment of Cranial Cruciate Ligament Deficiency in Dogs (전방 십자인대 결손을 보이는 개에서 TightRope을 이용한 치료방법 평가)

  • Yoon, Hun-Young;Kim, Kyung-Hee;Jeong, Soon-Wuk
    • Journal of Veterinary Clinics
    • /
    • v.29 no.6
    • /
    • pp.455-459
    • /
    • 2012
  • Nine dogs presented to the Veterinary Medical Teaching Hospital of Konkuk University and Woosung Animal Hospital with a history of pelvic limb lameness. On physical examination, 9 dogs all showed a consistent weight bearing lameness and mild muscle atrophy. There was cranial drawer sign with pain in 9 dogs. Mediolateral radiographic projection revealed cranial subluxation of the tibial tuberosity in a tibial compression view. The right and left stifle joints were affected in 7 dogs and 2 dogs respectively. TightRope cranial cruciate ligament (CCL) technique for treatment of CCL deficiency was performed. Polyester and nylon were used to stabilize the stifle in 3 dogs and 6 dogs respectively. Suture sizes were 0.8 mm (n = 2), 0.9 mm (n = 4), 1.1 mm (n = 2), and $1.1mm{\times}2$ strands (n = 1) in diameter. Mean (${\pm}SD$) surgical duration was $48.3{\pm}8.5$ minutes (range 35 to 60 minutes). Preoperative and postoperative mean (${\pm}SD$) cranial drawer signs were $8.6{\pm}1.6$ mm (rage 7 to 12 mm) and $1.2{\pm}1.0$ mm (rage 0 to 3 mm) respectively. Immediate postoperative radiographs of the affected limb revealed no evidence of cranial subluxation of the tibial tuberosity in a tibial compression view of 9 dogs. Normal limb function was regained in 8 dogs within 8 weeks postoperatively. A consistent weight bearing lameness resolved in all dogs after TightRope CCL technique, but reoccurred in one dog (case No. 6) 2 weeks after surgery. Cranial subluxation of the tibial tuberosity was identified in a tibial compression test. During the second surgery, breakage of surgical button was identified and a tibial wedge osteotomy was performed. Based on surgical time, complication, stifle stability, and functional recovery, the present study indicated that TightRope CCL technique is effective treatment for the dogs with CCL deficiency.

Minimally Invasive Arthroscopic-Assisted Reduction with TightRope® for Coxofemoral Luxation in a Korean Water Deer (Hydropotes inermis argyopus) (고라니에서 최소침습적 관절경과 TightRope®의 이용한 엉덩관절탈구 교정 증례)

  • Heo, Su-Young;Seol, Jae-won;Park, Ji-young;Jeong, Seong-mok;Lee, Hae-Beom
    • Journal of Veterinary Clinics
    • /
    • v.32 no.6
    • /
    • pp.540-543
    • /
    • 2015
  • A Korean water deer was rescued with non-weight-bearing lameness of the right hind limb. Clinical and radiographic examination revealed a craniodorsal coxofemoral luxation. The cause of the right coxofemoral luxation (CL) was unknown. We performed minimally invasive arthroscopic-assisted reduction with toggle pin fixation (mini TightRope$^{(R)}$). Craniodorsal CL in the water deer was reduced and stabilized successfully. At 60 days after admission, the water deer was successfully released back into the wild. This minimally invasive surgical technique can be used to correct coxofemoral luxation in wild animals.

Clinical and Radiological Outcomes of Acute Acromioclavicular Joint Dislocation: Comparison of Hook Plate Fixation with Single Tight Rope Technique

  • Lee, Sung Hyun;Kim, Jeong Woo;Kook, Seng Hwan
    • Clinics in Shoulder and Elbow
    • /
    • v.20 no.3
    • /
    • pp.153-161
    • /
    • 2017
  • Background: This study was conducted to compare the clinical and radiological outcomes of the locking hook plate fixation (HP) technique and the single tight rope (TR) technique applied for acute high-grade acromioclavicular (AC) joint separations. Methods: Between 2009 and 2014, 135 consecutive patients with acute AC joint separation Rockwood types III, IV, and V were subjected to surgical reconstruction. One hundred fourteen patients (84.4%) were available for retrospective evaluation. Of them, 62 and 52 were treated using the single TR group and clavicular HP group techniques, respectively. The visual analogue scale, Constant, American Shoulder and Elbow Surgeons (ASES), and Taft scores were used for clinical assessment. Postoperative shoulder range of motion was also assessed. An anteroposterior radiograph of the coracoclavicular distance (CCD) was obtained to evaluate the radiographic signs of recurrence. Results: The TR group patients had better Constant, ASES, and Taft scores than the HP group patients. The loss of reduction in terms of the CCD did not differ between groups. Subacromial osteolysis was observed in 34.6% of the cases in the HP group. However, there were no significant differences in the clinical outcomes between the patients with and without osteolysis in the HP group. Subcoracoid osteolysis, drill tunnel widening, and metal displacement were observed in 3.2%, 22.6%, and 4.8% of the cases in the TR group, respectively. Conclusions: The single TR technique was relatively more effective at treating acute high-grade AC joint injuries than the HP fixation technique (level of evidence: therapeutic; retrospective comparative study, Level III).

Coracoclavicular Ligament Augmentation Using Endobutton for Unstable Distal Clavicle Fractures - Preliminary Report - (불안정성 쇄골 원위부 골절에서의 Endobutton을 이용한 오구 쇄골 인대 보강술 - 예비 보고 -)

  • Cho, Chul-Hyun;Jung, Gu-Hee;Sin, Hong-Kwan;Lee, Young-Kuk;Park, Jin-Hyun
    • Clinics in Shoulder and Elbow
    • /
    • v.14 no.1
    • /
    • pp.1-5
    • /
    • 2011
  • Purpose: The purpose of this study was to evaluate the radiologic and clinical outcomes after operative treatment using endobuttons for unstable distal clavicle fractures. Materials and Methods: Between October 2007 and September 2009, 9 consecutive patients who were followed up for at least more than 12 months after operative treatment using a TightRope$^{(R)}$ were studied. The radiologic results on the serial plain radiographs and the clinical results according to the American Shoulder Elbow Surgeons (ASES) score were analyzed. Result: Bony union was shown in 8 cases (88.9%) and the average time to union was 12.9 (range: 9~16) weeks. The average coracoclavicular distances at the postoperative and final follow-up were 5.6 mm and 6.2 mm, respectively, with no statistically significant difference (p>0.05). The average ASES score was 90.3 (range: 78~96) and the clinical outcomes were 6 excellent, 2 good and one fair. There were no complications such as implant failure or infection except for one case of nonunion due to loss of the initial reduction. Conclusion: A major advantage of TightRope$^{(R)}$ fixation for unstable distal clavicle fractures is that no further surgery is needed to remove the implant. We suggest that this technique provides an alternative for fracture with a distal fragment, which is difficult to fix.

Intra-articular replacement of a ruptured cranial cruciate ligament using the Mini-TightRope in the dog: a preliminary study

  • Pinna, Stefania;Lanzi, Francesco;Tassani, Chiara;Mian, Giacomo
    • Journal of Veterinary Science
    • /
    • v.21 no.5
    • /
    • pp.53.1-53.12
    • /
    • 2020
  • Background: The TightRope System is a device developed to provide extracapsular stabilization of the cranial cruciate ligament (CCL) rupture in canine stifles. I was then also employed for the extra-articular treatment of shoulder instability and for the intra-articular treatment of hip luxation in dogs and cats. Objectives: To evaluate the feasibility of the Mini-TightRope (mTR) System for the intraarticular treatment of CCL rupture in small breed dogs. Methods: A cadaveric canine model was used to record the steps of the surgical procedure. Five client owned dogs weighing from 8 to 10 kg and from 2 to 12 years of age were enrolled in the prospective study in which the mTR device was implanted in the stifle joint to replace the ruptured CCL. The dogs were graded using the Bologna Healing Stifle Injury Index (BHSII) and radiographic osteoarthritis (OA) scores. Results: The outcomes obtained at the time of the surgery (T0) and for the following 12 months (T12) showed an improvement in the functional parameters (BHSII from a median of 74.3 [range, 58.1-82.4] at T0 to 95.6 [range, 94.1-99.3] at T12]). The OA did not change in 3 dogs and increased by only 1 point in 2 dogs. Conclusions: In this preliminary study, the mTR was a successful and repeatable intraarticular surgical procedure for all dogs. Additional studies related to the clinical application of the technique in medium-large dogs should be encouraged.

All-arthroscopic, Guideless Single Suture-button Fixation of Acute Acromioclavicular Joint Dislocation: A Description of the Technique and Early Treatment Results

  • Altintas, Burak;Yildiz, Fatih;Uzer, Gokcer;Kapicioglu, Mehmet;Bilsel, Kerem
    • Clinics in Shoulder and Elbow
    • /
    • v.20 no.2
    • /
    • pp.59-67
    • /
    • 2017
  • Background: The purpose of this study was to examine the clinical and radiological results of the all-arthroscopic, suture-button fixation technique to treat acute acromioclavicular (AC) joint separations. Methods: All patients with acute AC joint separations received all-arthroscopic, single suture-button (TightRope) procedure without a special guide. Postoperative Constant score (CS), pain level according to visual analogue scale, and range of motion (ROM) were evaluated. For radiological evaluation, coracoclavicular distances were measured bilaterally. Results: Between December 2010 and June 2012, 18 consecutive patients (4 women and 14 men; mean age, 29.3 years) with acute AC joint separations underwent surgical treatment after 6.4 days (range, 2-20 days) following the initial trauma. The average postoperative follow-up was 16.9 months. The mean CS was 92.4 (range, 84-96). The mean external rotation, forward flexion, and abduction were $75.8^{\circ}$ (range, $50^{\circ}-90^{\circ}$), $170^{\circ}$ (range, $150^{\circ}-180^{\circ}$), and $163.8^{\circ}$ (range, $140^{\circ}-180^{\circ}$), respectively. Five patients exhibited coracoclavicular ossifications. In two patients, superficial wound infections were successfully treated with antibiotic therapy. In one patient, a coracoid fracture was observed. No significant differences were found regarding pain, ROM, or strength parameters between both sides. The coracoclavicular distance was discovered to be approximately 2.8 mm greater on the affected side; however, this minimal reduction loss did not affect the functional results. Conclusions: The findings of this study suggests that all-arthroscopic treatment of AC joint separations using the single suture-button technique without a drill guide is safe, yielding good to excellent clinical results.