• Title/Summary/Keyword: Tidal Correction

Search Result 51, Processing Time 0.032 seconds

Hydrodynamic Aspects on Three-dimensional Effects of Vertical-axis Tidal Stream Turbine (조류발전용 수직축 터빈의 유체동력학적 3차원 효과에 관한 연구)

  • Hyun, B.S.;Lee, J.K.
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.16 no.2
    • /
    • pp.61-70
    • /
    • 2013
  • Hydrodynamic aspects on three-dimensional effects were investigated in this study for simple and convenient conversion of tidal stream energy using a Vertical-Axis Turbine (VAT). Numerical approach was made to reveal the differences of flow physics between 2-D estimation and rigorous 3-D simulation. It was shown that the 3-D effects were dominant mainly due to the variation of tip vortices around the tip region of rotor blade, causing the loss of lift for steadily translating hydrofoil and the reduction of torque for rotating turbine blade. The 3-D effect was found to be rather prominent for the typical VATs considered in this paper. Simple and yet efficient 2-D approach with the correction of its three-dimensionality was also proposed for practical design and analysis of VAT.

Sevoflurane with opioid or dexmedetomidine infusions in dogs undergoing intracranial surgery: a retrospective observational study

  • Marquez-Grados, Felipe;Vettorato, Enzo;Corletto, Federico
    • Journal of Veterinary Science
    • /
    • v.21 no.1
    • /
    • pp.8.1-8.11
    • /
    • 2020
  • This study reports the clinical use of two sevoflurane-based anesthetic techniques in dogs undergoing craniectomy. Twenty-one animals undergoing elective rostrotentorial or transfrontal craniectomy for brain tumor excision, anesthetized with sevoflurane, were enrolled in this retrospective, observational study. Anesthetic records were allocated to two groups: Sevo-Op (sevoflurane and short acting opioid infusion): 8 dogs and Sevo-Dex (sevoflurane and dexmedetomidine infusion): 13 dogs. Average mean arterial pressure (MAP), heart rate, end-tidal carbon dioxide, end-tidal sevoflurane and intraoperative infusion rates during surgery were calculated. Presence of intra-operative and post-operative bradycardia, tachycardia, hypotension, hypertension, hypothermia, hyperthermia was recorded. Time to endotracheal extubation, intraoperative occurrence of atrioventricular block, postoperative presence of agitation, seizures, use of labetalol and dexmedetomidine infusion were also recorded. Data from the two groups were compared with Fisher's exact test and unpaired t tests with Welch's correction. Odds ratio (OR) and 95% confidence interval (CI) were calculated for categorical variables. Intra-operatively, MAP was lower in Sevo-Op [85 (± 6.54) vs. 97.69 (± 7.8) mmHg, p = 0.0009]. Time to extubation was longer in Sevo-Dex [37.69 (10-70) vs. 19.63 (10-25), p = 0.0033]. No differences were found for the other intra-operative and post-operative variables investigated. Post-operative hypertension and agitation were the most common complications (11 and 12 out of 21 animals, respectively). These results suggest that the infusion of dexmedetomidine provides similar intra-operative conditions and post-operative course to a short acting opioid infusion during sevoflurane anesthesia in dogs undergoing elective rostrotentorial or transfrontal intracranial surgery.

Effects of Tracheal Suction and Method of Bronchodilator Inhalation on Vital Signs and Pulmonary functions in Patients with Open Heart Surgery(OHS) (심장수술 환아에게 기도흡인과 기관지 확장제의 투여 방법이 활력징후 및 폐기능에 미치는 효과)

  • Song Hyo-Sook;Jun Tae-Gook;Park Pyo-Won;Kim Kyoung-Eun;Chung Ji-Hye
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.10 no.1
    • /
    • pp.96-107
    • /
    • 2003
  • Objective: The purpose of this study was to identify the effects of tracheal suction and the effects of different methods of bronchodilator inhalation (Ultrasonic nebulizer: MDI puff, MDI puff with spacer) in VSD surgery patients. Material & Method: From June 2001 to March 2002, sixty consecutive patients were randomly assigned to a control group (n= 15), ultrasonic nebulizer group (n=15), metered dose inhalation (MDI) puff group (n=15) and MDI with spacer group (n=15). Vital signs (HR, BP, CVP), ABGA and pulmonary functions were measured before suction (baseline for suction), after suction, 15 minutes after suction (base of bronchodilator inhalation), 30 minutes after bronchodilator inhalation, and 2 hours after bronchodilator inhalation. Stastistical analysis was performed using SPSS software. Repeated measure ANOVA was used to examine the effects of tracheal suction. One way ANOVA with Bonferroni's correction and multiple range test (the least significant difference test) were used to examine the effects of albuterol inhalation. Result: 1. Heart .ate increased significantly immediately after suction (p<.01) and recovered 15 minutes after suction. 2. $PaO_2$ and PH decreased significantly immediately after suction (p<.05) and $PaO_2$ recovered 15 minutes after suction. $PaCO_2$ increased immediately after suction and significantly 15 minutes after suction (p<.01). But changes in vital signs and ABGA were within the normal range. 3. Tidal volume decreased significantly 15 minutes after suction (p<.05). 4. Changes of HR and tidal volume were greater in the nebuizer group compared to the other groups (p<.05) 30 minutes after bronchodilator inhalation and recovered 2 hours after bronchodilator inhalation. 5. Changes of airway deadspace was greater in the nebulizer group compared to the control group and MDI puff group 30 minutes after albuterol inhalation (p<.05) and at 2 hours (p<.01). Conclusion: Tracheal suction did not have significant effect on vital signs and pulmonary functions after OHS. Although the methods of bronchodilator inhalation did not showed any significant difference on pulmonary function, the nebulizer method increased $PaO_2$ (20%) and tidal volume transiently. If the patient needs bronchodilator inhalation with bronchospasm after OHS, the nebulizer method is the best choice. More study on the effects of bronchodilator inhalation in bronchospasm group is needed.

  • PDF

The Effect of Lung Volume on the Size and Volume of Pulmonary Subsolid Nodules on CT: Intraindividual Comparison between Total Lung Capacity and Tidal Volume (전산화단층촬영에서 폐 반고형결절의 크기와 용적에 호흡이 미치는 영향: 개인 내 전폐용량과 일호흡량 간 비교)

  • Hyunji Lee;Chansik An;Seok Jong Ryu
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.6
    • /
    • pp.1534-1544
    • /
    • 2021
  • Purpose To examine the effect of lung volume on the size and volume of pulmonary subsolid nodules (SSNs) measured on CT. Materials and Methods A total of 42 SSNs from 31 patients were included. CT examination was first performed at total lung capacity (TLC), and a section containing the nodule was additionally scanned at tidal volume (TV). The diameter and volume of each SSN, as well as the cross-sectional lung area containing the nodule, were measured. The significance of the changes in measurements between TLC and TV within the same individuals was evaluated. Results The lung area and the diameter and volume of SSNs decreased significantly at TV by 12.7 cm2, 0.5 mm, and 46.4 mm3 on average, respectively (p < 0.001), compared to those at TLC. Changes in lung area between TV and TLC were positively correlated with the change in SSN diameter (p = 0.027) and volume (p = 0.014). However, after correction (by considering the change in lung area), the changes in SSN diameter (p = 0.124) and volume (p = 0.062) were not significantly different. Conclusion SSN size and volume can be significantly affected by lung volume during CT scans of the same individuals.

Radiometric Characteristics of Geostationary Ocean Color Imager (GOCI) for Land Applications

  • Lee, Kyu-Sung;Park, Sung-Min;Kim, Sun-Hwa;Lee, Hwa-Seon;Shin, Jung-Il
    • Korean Journal of Remote Sensing
    • /
    • v.28 no.3
    • /
    • pp.277-285
    • /
    • 2012
  • The GOCI imagery can be an effective alternative to monitor short-term changes over terrestrial environments. This study aimed to assess the radiometric characteristics of the GOCI multispectral imagery for land applications. As an initial approach, we compared GOCI at-sensor radiance with MODIS data obtained simultaneously. Dynamic range of GOCI radiance was larger than MODIS over land area. Further, the at-sensor radiance over various land surface targets were tested by vicarious calibration. Surface reflectance were directly measured in field using a portable spectrometer and indirectly derived from the atmospherically corrected MODIS product over relatively homogeneous sites of desert, tidal flat, bare soil, and fallow crop fields. The GOCI radiance values were then simulated by radiative transfer model (6S). In overall, simulated radiance were very similar to the actual radiance extracted from GOCI data. Normalized difference vegetation index (NDVI) calculated from the GOCI bands 5 and 8 shows very close relationship with MODIS NDVI. In this study, the GOCI imagery has shown appropriate radiometric quality to be used for various land applications. Further works are needed to derive surface reflectance over land area after atmospheric correction.

The Coastline Change on Gwangalli Using Spatial Information (공간정보를 이용한 광안리 해안선 변화에 관한 연구)

  • Choi, Chul-Uong;Oh, Che-Young;Lee, Chang-Hun
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.17 no.1
    • /
    • pp.13-19
    • /
    • 2009
  • The Gwangalli Beach, one of beaches representative of Busan together with the Haeundae Beach, is a tourist attraction, having increased tourists since the completion of Gwangandaero Bridge in 2003 and recording more than 10 million tourists in 2006. Although the competent local government office has conducted artificial beach nourishment/gravel removal projects every year to manage it, systematic monitoring and studies of erosion are insufficient. This study analyzed the changes in the coastline of Gwangalli Beach using aerial photos, tidal data, GPS survey data for the last sixty years, and examined how the Gwangandaero Bridge, which had been constructed on the Gwanganlli sea, has affected the changes. The results show that the area of Gwangalli Beach has increased 40% for the last sixty years, and that the effects of Gwangandaero Bridge on the coastline are insignificant.

  • PDF

Coastline Changes in the Tumen River Estuary over the Past 35 Years Using the Landsat Satellite Imagery (LANDSAT 위성영상을 이용한 과거 35년간 두만강 하구 해안선 변화 연구)

  • Zhao, Yuwei;Zhao, Shuqing;Xu, Zhen;Lee, Dongkun
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.27 no.3
    • /
    • pp.57-66
    • /
    • 2024
  • Coastline changes evolution of different intensities at all times under the influence of natural and anthropogenic effects. In this paper, we extracted the coastline of the Tumen River estuary from 1985 to 2020 using the digitizing method, verified the accuracy using the visual interpretation results, and analyzed the changes of the coastline of the Tumen River estuary through the area method and the baseline method. The results showed that the coastline showed an erosion trend during 35 years, with an average erosion rate of 0.05 m/year, an average erosion distance of 3.06 m, and an erosion area of 19.25 ha. Among the human activities that retarded the erosion of the coastline, these activities had a long-term impact on the natural morphology of the coastline.

Signal Treatement for Topex/Poseidon Satellite Altimetric Data and Its Application near the Korean Seas (Topex/Poseidon위성 고도계 자료에 대한 신호처리 및 한반도 주변해역에 대한 그 적용)

  • Yoon, Hong-Joo
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.2 no.1
    • /
    • pp.12-31
    • /
    • 1999
  • Topex/Poseidon satellite altimetric data are used to estimate characteristics on the oceanic and atmospheric correction factors, and the mean sea level and its variations in the Yellow Sea, the East China Sea and the East Sea from September 1992 through August 1994(70cycles). For the atmospheric correction factors, the variations of dry troposphere, humid troposphere, ionosphere and inverted barometer were very small as a few centimeters, but the variations of electromagnetic bias were higher than other factors. For the oceanic correction factors, the variations of ocean tide(35cm in track 127 and 60cm in track 214) showed high ranges compared to elastic tide(5cm in track 127 and 1cm in track 214) and loading tide(1.8cm in track 127 and 1cm in track 214). It should be understood that the variations of ocean free surface is mainly under the influence of, firstly, ocean tide and, secondly, electromagnetic bias. Mean sea level in the Yellow Sea are higher than in the rest of Seas. Then its range generally comprised between -60cm and 210cm with mean value of about 100cm. Also its variations showed high values in the Yellow Sea and East China Sea, especially 5.689cm in Youngampo. This result is mainly due to the effects of local topography and tidal current.

  • PDF

Analysis of Tidal Deflection and Ice Properties of Ross Ice Shelf, Antarctica, by using DDInSAR Imagery (DDInSAR 영상을 이용한 남극 로스 빙붕의 조위변형과 물성 분석)

  • Han, Soojeong;Han, Hyangsun;Lee, Hoonyol
    • Korean Journal of Remote Sensing
    • /
    • v.35 no.6_1
    • /
    • pp.933-944
    • /
    • 2019
  • This study analyzes the tide deformation of land boundary regions on the east (Region A) and west (Region B) sides of the Ross Ice Shelf in Antarctica using Double-Differential Interferometric Synthetic Aperture Radar (DDInSAR). A total of seven Sentinel-1A SAR images acquired in 2015-2016 were used to estimate the accuracy of tide prediction model and Young's modulus of ice shelf. First, we compared the Ross Sea Height-based Tidal Inverse (Ross_Inv) model, which is a representative tide prediction model for the Antarctic Ross Sea, with the tide deformation of the ice shelf extracted from the DDInSAR image. The accuracy was analyzed as 3.86 cm in the east region of Ross Ice Shelf and it was confirmed that the inverse barometric pressure effect must be corrected in the tide model. However, in the east, it is confirmed that the tide model may be inaccurate because a large error occurs even after correction of the atmospheric effect. In addition, the Young's modulus of the ice was calculated on the basis of the one-dimensional elastic beam model showing the correlation between the width of the hinge zone where the tide strain occurs and the ice thickness. For this purpose, the grounding line is defined as the line where the displacement caused by the tide appears in the DDInSAR image, and the hinge line is defined as the line to have the local maximum/minimum deformation, and the hinge zone as the area between the two lines. According to the one-dimensional elastic beam model assuming a semi-infinite plane, the width of the hinge region is directly proportional to the 0.75 power of the ice thickness. The width of the hinge zone was measured in the area where the ground line and the hinge line were close to the straight line shown in DDInSAR. The linear regression analysis with the 0.75 power of BEDMAP2 ice thickness estimated the Young's modulus of 1.77±0.73 GPa in the east and west of the Ross Ice Shelf. In this way, more accurate Young's modulus can be estimated by accumulating Sentinel-1 images in the future.

Development of a Voltage Measuring System for the Pusan-Hamada Submarine Cable (부산 - 병전간 해저케이블 전압측정 장치의 개발)

  • Bahk, Kyung-Soo
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.3 no.4
    • /
    • pp.255-260
    • /
    • 1991
  • A voltage measuring system specified for the voltage fluctuation of the Pusan-Hamada submarine cable is developed by adding circuits of differential amplification and analog-to-digital conversion to a microprocessor-based data logger with a data modem. This system is charaterized by its small size. no power failure. fully unmanned operation. and precise instrumental drift correction. In addition to the cable voltage and current it measures an ambient temperature and a mercury cell voltage in order to calibrate temperature effect and check its long-term stability. The data acquired by this system show that the voltage signal. comprising fast random noises with a constant width of about 0.2V. fluctuates within a range of about 1V and the fluctuation frequency is similar to that of tidal motion. The source voltage of power feeding equipment (PFE) for the cable system seems to be affected when the room temperature changes rapidly.

  • PDF