• 제목/요약/키워드: Tibial tunnel fixation

검색결과 22건 처리시간 0.019초

Rigidfix 와 Infrafix 로 고정한 슬괵건을 이용한 전방 십자인대 재건술 후 경골터널의 확장

  • 최남홍;정유훈
    • 대한관절경학회:학술대회논문집
    • /
    • 대한관절경학회 제21차 추계 학술대회
    • /
    • pp.153-153
    • /
    • 2009
  • The purpose of this study was to evaluate tibial tunnel widening prospectively after anterior cruciate ligament (ACL) reconstruction with hamstring tendon grafts using Rigidfix (DePuy Mitek, Raynham, MA) femoral fixation and Intrafix (DePuy Mitek) tibial fixation. 56 consecutive patients who underwent ACL reconstruction with a minimum of 2 years' postoperative evaluation were reviewed. On the anterior-posterior (AP) and lateral radiographs, the diameter of the tibial tunnel was measured at proximal, middle, and distal positions and the shape of the tibial tunnels were classified. Tunnel widening was defined as widening of greater than 2 mm. Group I was defined as cases with no tunnel widening and group II defined as cases with tunnel widening. Postoperative laxity evaluations were performed using Lachman test, pivot-shift test, and Instrumented laxity testing using the KT-1000 arthrometer. On the AP radiographs, the average diameter of the tibial tunnel increased 8.8% at 6 months and 8.5% at 12 months postoperatively compared to the immediate postoperative day. On the lateral radiographs, the average diameter of the tibial tunnel increased 7.2% at 6 months and 8.1% at 12 months year postoperatively compared to the immediate postoperative day. The tunnel shape evaluation revealed predominantly linear type in 53 patients (95%). Group I was 42 patients (75%) and group II was 14 (25%). The average KT-1000 measurement was 1.0~1.8 mm in group I and 2.1~2.8 mm in group II (p>0.05) The Lachman and pivot-shift showed tests no significant differences between the two groups. In conclusion, hamstring ACL reconstruction using Rigidfix and Intrafix fixation showed less widening of the tibial tunnels than observed in previously published studies.

  • PDF

TransFix 경골부 고정을 이용한 경 경골 두 다발 후방십자인대 재건술 - 수술 술기 - (Transtibial Double Bundle PCL Reconstruction using TransFix Tibial Fixation - Technical Note -)

  • 이용석;정영복;안진환;강번중;신윤창;공제관
    • 대한관절경학회지
    • /
    • 제10권2호
    • /
    • pp.203-208
    • /
    • 2006
  • 목적: 후방십자인대의 경 경골 두 다발 재건술에 있어서 기존의 방법들은 공여 인대가 길어야 하는 문제 때문에 이식건의 선택이 제한적인 경우가 많으며 경골부에서 이중의 고정을 해야 하는 문제점 등이 있다. 이에 저자들은 두 다발 재건술을 실시하면서 경골부에서 초기에 단일 고정으로써 안정성을 얻고, 공여 인대 길이에 제한을 덜 받는 방법을 소개하고자 한다. 수술 술기: 진단적 관절경 검사를 실시 한 후 두 다발 재건술을 위한 이식건을 준비하고, 경골 터널 및 TransFix 고정을 위한 준비를 한다. 대퇴부에 2개의 터널을 만들고, 이식건을 전 내측 입구를 이용하여 경골부, 대퇴부 순으로 통과시킨 후 TransFix를 이용하여 경골부에 고정을 먼저 실시하고, 대퇴부의 2 다발을 각각의 고정 위치에서 고정을 실시한다. 결론: 경경골 터널을 이용한 두 다발 후방십자인대 재건술에서 TransFix를 이용한 경골부의 고정은 단일 고정으로써 강한 고정을 제공하면서 이식건의 길이에 제한을 받지 않고, 전 내측 입구로 이식건을 통과시킴으로써 이식건의 손상을 방지할 수 있는 좋은 방법이라고 생각한다.

  • PDF

자가 슬괵건을 이용한 전방 십자인대 재건술시 경골측 골 터널내 고정의 의의 (이차관절경 검사의 평가) (Significance of tibial intra-tunnel fixation at Arthroscopic ACL Reconstruction with hamstring tendon (Second-look Arthroscopic Evalution))

  • 김영창;서승석;정경칠;곽희철;김윤준;김진석
    • 대한관절경학회지
    • /
    • 제10권2호
    • /
    • pp.165-172
    • /
    • 2006
  • 목적: 자가 슬괵건을 이용한 관절경하 전방십자인대 재건술시 이식건의 경골측 골 터널내 고정의 유용성을 이차 관절경 검사의 추시 관찰을 통하여 평가 하고자 하였다. 대상 및 방법: 1999년 12월부터 2005년 5월까지 자가 슬괵건을 이용한 전방 십자인대 재건술을 시행한 환자 중 이차 관절경 검사를 시행한 32례를 대상으로 하였다. 경골측의 고정방법에 따라 나사못 실고정만을 시행한 군(제 1군)과 나사못 실고정과 간섭나사를 이용한 경골측 골 터널내 고정을 함께 시행한 군(제 2군)으로 구분하였다. 이차 내시경 추시 관찰시의 평균 나이는 30세였으며 남자가 30례, 여자가 2례였고 전방십자인대 재건술 후 이차 관절경 검사를 시행한 기간은 평균 21.3개월이었다. 결과는 마취하의 KT-1000 관절계와 IKDC 분석 및 경골측 골 터널의 크기와 Telos 스트레스 부하 검사를 방사선학적으로 평가하였으며, 이차 관절경 소견의 평가 또한 시행하였다. 결과: 평가한 IKDC분석 및 Telos스트레스 부하 방사선 검사상의 전이 정도와 KT-1000 관절계상의 전이정도는 제2군에서 우수한 소견을 보였으나, 통계적으로 의미 있는 차이를 보이진 않았다. 관절 내시경상의 이식건의 긴장도, 이식건의 육안 소견, 이식건의 활액막 증식 정도도 제2군에서 우수한 소견을 보였으나, 통계적으로 의미 있는 차이를 보이진 않았다. 전후면 방사선 사진상 경골측의 골터널의 확장은 제1군에서 2.3 mm 및 제2군에서 1.7 mm로 측정되어 통계적으로 의미 있는 차이를 보였다(P=0.042). 결론: 자가 슬괵건을 이용한 십자 인대 재건술에서 경골측 골 터널내 고정의 부가하는 시술은 경골측 골터널의 확대를 의미 있게 감소 시켰으나 수술 후의 임상적 결과, 관절의 동요 정도, 관절경적 소견에 있어 유의한 차이는 보이지 않았다. 본 연구에서 경골측 고정을 위해 나사못 실고정 단독으로 사용하여도 만족스러운 임상적 결과, 관절의 안정도, 이식건의 성숙을 얻을 수 있었고 경골측 골터널의 확대는 결과에 영향을 미치지 않는다는 것을 알 수 있었다.

  • PDF

자가 슬괵건을 이용한 관절경적 전방 십자 인대 재건술 - INTRAFIX system을 이용한 경골부 고정 후 부가적 고정의 효과 - (Arthroscoic Anterior Cruciate Ligament Reconstruction with Autogenous Hamstring Gratt - Effect of the Additional Fixation after Fixation of the Graft with Intrafix -)

  • 유재두;노권재;신상진;윤종석;여성구
    • 대한관절경학회지
    • /
    • 제9권1호
    • /
    • pp.51-55
    • /
    • 2005
  • 목적: 자가 슬괵건을 이용한 전방 십자 인대 재건술 후 대퇴 터널 내의 고정은 2개의 생흡수성 핀인 Rigidifix system (Mitek Product, Johnson and Johnson, USA)를 이용하여 고정하고, 경골 터널 내는 Intrafix system을 이용한 생간섭나사로 고정 후 이식건의 경골 족에 인대 고정 나사를 이용한 부가적 고정이 수술 후 슬관절 전방 안정성에 영향을 주는지를 알아 보고자 하였다. 대상 및 방법: 2002년 5월부터 2003년 1월까지 Rigidfix와 Intrafix를 이용하여 관절경적 전방 십자 인대 재건술을 시행 받은 39명 중 추시 관찰이 되지 않은 2명을 제외한 37명의 환자를 대상으로 하였다. 평균 추시 기간은 14개월(범위: $25{\sim}13$개월) 이었다. 부가적 고정 여부의 결정은 수술 순서에 따라서 교대로 선택하였고, 경골 터널 밖으로 나온 이식건을 인대 고정 나사로 고정하였고 이식건이 짧은 경우는 봉합사를 인대 고정 나사에 묶었다. Intrafix만으로 고정한 경우 17명, 부가적 고정을 한 경우가 20명이었다. 내측 반월상 연골의 절제 2예, 내측 반월상 연골의 봉합 2예, 외측 반월상 연골의 봉합 1예에서 시행하였다. 임상적 평가는 이학적 검사인 Lachman검사, Pivot shift 검사와 재건술 후의 Lysholm점수, IKDC (International Knee Documentation Committee)평가 기준, KT-1000관절 계측 결과를 이용하였다. 결과: 최종 추시 상 수술 후 Lysholm점수는 93.1점(범위: $65{\sim}98$점), IKDC 평가 기준에 의한 최종 평가 상 정상(A) 26예, 거의 정상(8) 10예, 비정상(C) 1 예이었으며, 심한 비정상은 (D)은 없었다. 최종 추시 상 KT-1000 관절계를 이용한 최대 도수 부하 검사 상 건측과의 차이는 평균 2.5mm$(0{\sim}6mm)$ 이였다. 술 후 시행한 Lachman 검사 상 정상 32예, 1 등급 4예, 2 등급 II 1예 이었고, Pivot shift 검사 상 정상 34예, 1 등급 2예, 2등급 1예 이었다. KT-1000 관절계를 이용한 최대 도수 부하 검사 상 건측과의 차이는 부가적 고정을 한 경우는 평균 2.2 mm$(0{\sim}4mm)$ Intrafix 만으로 고정한 경우는 평균 2.8 mm$(0{\sim}6mm)$였다. 두 군 사이에 통계학적으로 유의한 차이는 없었다(P>0.05). 결론: 자가 슬괵건을 이용한 전방 십자 재건술 후 전방 안정성은 Intrafix를 이용한 경골 터널 내의 이식건의 고정이 부가적 고정을 한 경우와 비교하여 차이가 없었다. 따라서 경골 터널 내에서 부가적 고정 없이 슬괵건의 고정만으로도 전방 안정성을 얻을 수 있다고 사료된다.

  • PDF

자가 슬괵근을 이용한 전방 십자 인대 재건술 후 발생한 전경골 낭종 - 증례 보고 - (Pretibial cyst after Arthroscopic Anterior Cruciate Ligament Reconstruction using Hamstring Autograft - A Case Report -)

  • 서승석;김창완;하동준;정훈재
    • 대한관절경학회지
    • /
    • 제13권1호
    • /
    • pp.53-57
    • /
    • 2009
  • The pretibial cyst is a very rare complication after anterior cruciate ligament (ACL) reconstruction. It occurs whatever kind of graft choice or kind of graft fixation method at tibial side. It have been known such as graft necrosis at tibial side, extra-articular leakage of joint fluid through tibial tunnel, foreign body reaction due to breakdown of the bioabsorbable screw and incomplete incorporation of graft to bony tunnel as the cause of pretibial cyst. We experienced one case of pretibial cyst which had undergone ACL reconstruction with autogenous hamstring graft fixed with biodegradable interference screw. We report a rare case of pretibial cyst with literature review.

  • PDF

생체분해성간섭나사를 이용한 전방십자인대 재건술 후 발생한 경골 근위부 낭종-증례 보고- (Pretibial Cyst after Anterior Cruciate Ligament Reconstruction Using bio-absorbable interference screw fixation - A Case Report -)

  • 전근철;김정우;김태균;전철홍
    • 대한정형외과스포츠의학회지
    • /
    • 제11권1호
    • /
    • pp.57-61
    • /
    • 2012
  • 전방십자인대 재건술 후에 발생한 커다란 크기의 경골 근위부 낭종은 드문 합병증이다. 경골 전방의 낭종은 생분해성간접나사의 분해로 인한 이물반응으로 발생하나 이 외에도 여러 가지 원인들로 인해 발생하게 된다. 저자들은 38세 남자환자에서 전방십자인대 재건술을 시행한지 2년 후 발생한 경골 전방의 커다란 크기의 낭종 1예를 관찰하였기에 동종골을 이용한 골 이식을 시행하고 예상되는 발생 원인을 문헌 고찰과 함께 보고하고자 한다.

  • PDF

관절강 내에서 모든 수술 과정을 시행하는 관절경적 전방십자인대 재건술 (All-Inside Technique of Anterior Cruciate Ligament Reconstruction using Central Quadriceps Tendon and Patella Bone Block)

  • 정화재
    • 대한관절경학회지
    • /
    • 제1권1호
    • /
    • pp.66-71
    • /
    • 1997
  • The all inside anterior cruciate ligament reconstruction technique places an anterior ligament substitutes within two bony sockets rather than hone tunnel. This approach is accomplished through arthroscopic three portal which avoids the surgical exposure and morbidity associated with creating traditional bone tunnel. This technique has several distinct advantages when compared with the traditional ACL reconstruction through the bone tunnels. It offers the surgeon a less morbid method for ACL reconstruction that positions an ACL substitute at the anatomic attachment sites of the original ACL with two bone sockets, obviating the need for traditional bone tunnels. Graft fixation at or near the anatomic attachment points of the original ACL minimizes creep with early range of motion and reduces the abrasive 'wind-shield wipe' motion of the graft which occur with bone plugs positioned inside bone tunnels. The sagittal posterior angle to the tibial socket increases fixation strength to pullout with anterior translation force for the tibia on the femur. This technique is not graft specific and can accomodate any graft in which graft length can be customized to the intraarticular native ACL length.

  • PDF

슬괵건을 이용한 전방십자인대 재건술시 횡고정 핀과 간섭나사를 이용한 대퇴터널 고정술 -수술 수기- (Cross-Pin and Interference Screw Femoral Fixation in Anterior Cruciate Ligament Reconstruction using Hamstring Tendon -Technical Note-)

  • 인용;박원종;박종범;홍승환
    • 대한관절경학회지
    • /
    • 제6권1호
    • /
    • pp.60-63
    • /
    • 2002
  • 목적 : 네 겹의 슬괵건을 이용한 전방십자인대 재건술시 대퇴터널을 횡고정 핀과 흡수성 간섭나사로 함께 고정하는 수기를 소개하고자 한다. 수술 술기 : 반건양건과 박건을 채취하여 네 겹으로 준비하였다. 경골터널과 대퇴터널을 만드는데 대퇴터널의 깊이는 35 mm로 하였다. Rigidfix system의 가이드를 삽입하고 가이드의 위쪽 관에만 구멍을 내었다. 이식건을 통과시킨후 횡고정 핀 을 고정하였다. 이후 이식건을 경골쪽으로 당기면서 흡수성 간섭 나사로 고정하였다. 결론 : 슬괵건 전방십자인대 재건술시 횡고정 핀과 흡수성 간섭나사를 이용한 대퇴터널 고정은 강한 초기 고정과 이식건의 골통합을 촉진시킬 수 있는 좋은 방법으로 사료되어 소개하였다.

  • PDF

생분해성 간섭나사를 이용한 전방십자인대 재건술 후 발생한 지연성 염증반응 - 증례 보고 - (The Delayed Inflammatory Reaction after Anterior Cruciate Lligament Reconstruction with a Bioabsorbable Interference Screw Fixation - A Case Report -)

  • 임홍철;노경선;양재혁
    • 대한관절경학회지
    • /
    • 제10권1호
    • /
    • pp.87-90
    • /
    • 2006
  • 자가 슬개건을 이용한 전방십자인대 재건술 시 사용되는 생분해성 간섭나사로 인한 합병증은 많지 않다. 저자들은 슬개건을 사용한 전방십자인대 재건술 시 생분해성 간섭 나사로 이식건을 고정 후 경골과 대퇴골 터널에 발생한 지연성 염증반응 1예에 대해 보고하고자 한다.

  • PDF

Hybrid 대퇴 고정과 $Retroscrew^{(R)}$를 사용한 동종 경골건 이용 전방 십자 인대 재건술의 임상적 결과 (The Clinical Results of ACL Reconstruction with Tibialis Allograft Using Hybrid Femoral Fixation and $Retroscrew^{(R)}$)

  • 김두섭;라중호
    • 대한관절경학회지
    • /
    • 제13권1호
    • /
    • pp.8-13
    • /
    • 2009
  • 목적: 전방 십자 인대 재건술을 위해 동종 경골건을 이용하였고 대퇴 고정을 위해 $Endobutton^{(R)}$$Rigidfix^{(R)}$을 사용한 Hybrid 대퇴고정 그리고 경골 고정을 위해 $Retroscrew^{(R)}$ 및 추가 고정을 시행한 후 임상적 결과를 알아보고자 하였다. 대상 및 방법: 2004년 2월부터 2007년 2월까지 Hybrid 대퇴 고정과 $Retroscrew^{(R)}$를 이용한 전방 십자 인대 재건술을 시행하였고 1년 이상 추시(범위: 12~25개월) 가능 하였던 32명, 32례를 대상으로 하였다. 임상적 결과는 재건술 전후 Lysholm 슬관절 점수, IKDC 평가 기준, $Telos^{(R)}$ 전방 전위 검사를 이용하였고 최종 추시시 단순 방사선 전후면 및 측면 사진을 촬영하여 골 터널 확장 정도를 측정하였다. 결과: Lysholm 슬관절 점수는 술 전 평균 $67.9{\pm}5.4$점(범위: 51~77점)에서 최종 추시시 $94.1{\pm}6.8$점(범위: 68~98점)으로 유의하게 향상되었고(p<0.05) IKDC 최종 추시 평가상 정상(A) 22례(69%), 거의 정상(B) 9례(28%), 비정상(C) 1례(3%)로 심한 비정상(D)을 보이는 경우는 없었다. $Telos^{(R)}$ 스트레스 부하 방사선 검사상 건측과의 차이가 술 전 평균 $13.2\;mm{\pm}5.8$(범위: 6~21 mm)에서 술 후 평균 $3.4\;mm{\pm}2.8$(범위: 0~11 mm)로 유의하게 호전되었다(p<0.05). 골 터널 확장은 대퇴 터널은 전후면 사진상 18.7%, 측면 사진상 12.4%(p<0.05), 경골 터널은 전후면 사진상 9.6%, 측면 사진상 8.5%의 확장을 보였다(p<0.05). 그러나 골 터널 확장의 정도와 슬관절 기능 사이에는 통계학적 유의성을 보이지 않았다(p>0.05). 결론: 동종 경골건의 고정시 Hybrid 대퇴고정과 $Retroscrew^{(R)}$를 이용한 전방 십자 인대 재건술은 이식건의 해부학적 고정을 가능하게 하였고 임상적으로 우수한 결과를 보였다.

  • PDF