• Title/Summary/Keyword: Ti-oxide

검색결과 1,350건 처리시간 0.032초

$PbTiO_3$-폴리머 O-3 복합 재료의 압전 특성에 관한 연구 (Piezoelectric Properties of O-3 Composite with $PbTiO_3$--Polymer)

  • 김일호;박인길;이성갑;이영희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1988년도 추계학술대회 논문집
    • /
    • pp.50-53
    • /
    • 1988
  • Lead titanate powders were prepared by mixed-oxide and sol-gel method. O-3 composites were prepared with these powders using Eccogel polymer. According to the volume percent of the PbTiO$_3$ powders, dielectric, piezoelectric properties and poling conditions were investigated. Relative dielectric constants were exponentially increased with volume percent of PbTiO$_3$. Piezoelectric strain coefficients (d$_{33}$ ) were increased with volume percent of PbTiO$_3$. Figure of merit (d$_{h}$.g$_{h}$) for the O-3 composites prepared by the mixed-oxide and sol-gel method were 2728(x10$^{-15}$ $m^2$/N) and 3100(x10$^{-15}$ $m^2$/N) at 70 volume percent of PbTiO$_3$, respectively.ely.

  • PDF

Ti-MCM-22 촉매를 이용한 프로필렌 에폭시화반응 (Propylene Epoxidation Using Ti-MCM-22 Catalyst)

  • 양승태;반한주;김세영;안희승
    • Korean Chemical Engineering Research
    • /
    • 제46권4호
    • /
    • pp.665-668
    • /
    • 2008
  • 티타늄 함유 제올라이트 촉매 Ti-MCM-22를 이용하여 과산화수소를 산화제로 한 프로필렌 에폭시화반응을 수행하였으며, 반응 온도와 압력, 촉매량, 한계 반응물인 과산화수소의 농도, 산화프로필렌의 첨가, 용매 및 촉매 재생 효과를 조사하였다. Acetonitrile 용매 하에서 반응 실험을 수행한 결과, 99% 이상의 $H_2O_2$ 전화율과 100%에 근접하는 산화프로필렌 선택도를 보였다.

TiB$_2$ 세라믹스의 산화 (The Oxidation of TiB$_2$ Ceramics)

  • 이동복;이영찬
    • 한국표면공학회지
    • /
    • 제34권1호
    • /
    • pp.25-32
    • /
    • 2001
  • $TiB_2$ ceramics were oxidized at 800, 900 and $1000^{\circ}C$ in air for 40 hr, and their oxidation property was investigated using TGA, XRD, SEM and EPMA. The oxidation resistance decreased with an increase in oxidation temperature. The scale was essentially composed of $TiO_2$ only. $B_2$$O_3$ formed during oxidation escaped from the $TiO_2$ oxide scale owing to its high vapor pressure. This made the oxide scale highly porous and thick. The oxidation reaction was mainly governed by the inward transport of oxygen.$ TiO_2$ existing at the outermost scale grew into peculiarly shaped blades, as the reaction progressed.

  • PDF

Ti-33.8wt% Al 금속간 화합물의 고온 산화거동 (High temperature oxidation behavior of Ti-33.8wt% Al intermetallic compounds)

  • 최송천;조현준;이동복
    • 한국표면공학회지
    • /
    • 제26권5호
    • /
    • pp.235-244
    • /
    • 1993
  • The oxidation behavior of a two-phase(Ti3Al+TiAl) intermetallic compound, Ti-33.8wt%Al, has been in-vestigated in air at 800, 900 and $^1000{\circ}C$. Though the isothermal oxidation behavior followed a parabolic law up to 100$0^{\circ}C$ indicating that protective oxide scales were formed, the cyclic oxidation behavior followed a lin-ear law in the entire temperature range tested because flaky or stratified scales were usually spalled from the surface during cooling. During oxidation at 80$0^{\circ}C$, the alloy showed excellent oxidation resistance because continuous protective Al2O3 films were formed on the outermost surface of the alloy. However, above $900^{\circ}C$, the oxidation resistance of the alloy was decreased gradually because relatively non-protective TiO2 scales as well as some of Al2O3 scales were formed on the outer oxide scale. The oxidation mechanism of the alloy at different temperature was proposed.

  • PDF

Si and Mg Coatings on the Hydroxyapatite Film Formed Ti-29Nb-xHf Alloys by Plasma Electrolyte Oxidation

  • Park, Seon-Yeong;Choe, Han-Cheol
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2017년도 춘계학술대회 논문집
    • /
    • pp.152-152
    • /
    • 2017
  • Titanium and its alloys have been widely used for biomedical applications. However, the use of the Ti-6Al-4V alloy in biomaterial is then a subject of controversy because aluminum ions and vanadium oxide have potential detrimental influence on the human body due to vanadium and aluminum. Hence, recent works showed that the synthesis of new Ti-based alloys for implant application involves more biocompatible metallic alloying element,such as, Nb, Hf, Zr and Mo. In particular, Nb and Hf are one of the most effective Ti ${\beta}$-stabilizer and reducing the elastic modulus. Plasma electrolyte oxidation (PEO) is known as excellent method in the biocompatibility of biomaterial due to quickly coating time and controlled coating condition. The anodized oxide layer and diameter modulation of Ti alloys can be obtained function of improvement of cell adhesion. Silicon (Si) and magnesium (Mg) has a beneficial effect on bone. Si in particular has been found to be essential for normal bone and cartilage growth and development. In vitro studies have shown that Mg plays very important roles in essential for normal growth and metabolism of skeletal tissue in vertebrates and can be detected as minor constituents in teeth and bone. Therefore, in this study, Si and Mg coatings on the hydroxyapatite film formed Ti-29Nb-xHf alloys by plasma electrolyte oxidation has been investigated using several experimental techniques. Ti-29Nb-xHf (x= 0, 3, 7 and 15wt%, mass fraction) alloys were prepared Ti-29Nb-xHf alloys of containing Hf up from 0 wt% to 15 wt% were melted by using a vacuum furnace. Ti-29Nb-xHf alloys were homogenized for 2 hr at $1050^{\circ}C$. The electrolyte was Si and Mg ions containing calcium acetate monohydrate + calcium glycerophosphate at room temperature. The microstructure, phase and composition of Si and Mg coated oxide surface of Ti-29Nb-xHf alloys were examined by FE-SEM, EDS, and XRD.

  • PDF

Surface Characteristics of Anodized Ti-3wt%, 20wt%, and 40wt%Nb Alloys

  • Ko, Y.M.;Choe, H.C.;Jang, S.H.;Kim, T.H.
    • Corrosion Science and Technology
    • /
    • 제8권4호
    • /
    • pp.143-147
    • /
    • 2009
  • In biomedical implants and dental fields, titanium has been widely utilized for excellent corrosion resistance and biocompatibility. However, Ti and its alloys are nonbioactive after being implanted in bone. In this study, for the purpose of improvement in biocompatibility the anodic $TiO_2$ layer on Ti-xNb alloys were fabricated by electrochemical method in phosphate solution, and the effect of Nb content on the pore size, the morphology and crystallinity of Ti oxide layer formed by the anodic oxidation method was investigated. The Ti containing Nb up to 3 wt%, 20 wt% and 40 wt% were melted by using a vacuum furnace. The sample were cut, polished, and homogenized for 24 hr at $1050^{\circ}C$ for surface roughness test and anodizing. Titanium anodic layer was formed on the specimen surface in an electrolytic solution of 1 M phosphoric acid at constant current densities ($30mA/cm^2$) by anodizing method. Microstructural morphology, crystallinity, composition, and surface roughness of oxide layer were observed by FE-SEM, XRD, EDS, and roughness tester, respectively. The structure of alloy was changed from $\alpha$-phase to $\beta$-phase with increase of Nb content. From XRD results, the structure of $TiO_2$ formed on the Ti-xNb surface was anatase, and no peaks of $Nb_2O_5$ or other Nb oxide were detected suggesting that Nb atoms are dispersed in $TiO_2$-based solid solution. Surface roughness test and SEM results, pore size formed on surface and surface roughness decreased as Nb content increased. From the line analysis results, intensity of Ti peak was high in the center of pore, whereas, intensity of O peak was high in the outside of pore center.

반투명 태양전지용 Al-Ti계 산화물 박막의 반사율 특성 개선에 관한 연구 (Study on Reflectance Improvement of Al-Ti Based Oxide Thin Films for Semitransparent Solar Cell Applications)

  • 이은규;정소운;방기수;이승윤
    • 한국전기전자재료학회논문지
    • /
    • 제31권7호
    • /
    • pp.437-442
    • /
    • 2018
  • This work reports the preparation of Al-Ti based oxide thin films and their optical properties. Although the transmittance of a $TiO_2/Al2O_3$ bilayer structure was as high as 90% at wavelengths of 600 nm or larger, the reflectance of the bilayer reached its minimum at wavelengths of around 360 nm. The transmittance of an 89-nm-thick $TiO_2$ thin film rapidly increased and then decreased at a critical wavelength because of destructive interference. The wavelength corresponding to the reflectance minimum increased after an increase in $TiO_2$ film thickness. The smooth surface morphology of the AlTiO thin film was retained up to a film thickness of 65 nm, and the transmittance of the film was inversely proportional to film thickness, in accordance with the general tendency for optical films. The reflectance of the AlTiO film at visible light wavelengths was lower than that of the $TiO_2$ film, which implies that the AlTiO film is suitable for applications as an optical thin film layer in semitransparent solar cells.

졸-겔법에 의한 ITiO(Indium Titanium Oxide) 입자의 합성과 ITiO 박막의 광투과도 조사 (Synthesis of ITiO(Indium Titanium Oxide) particle by sol-gel and investigation on light transmittance of deposited ITiO thin film)

  • 고은주;김상헌
    • 한국응용과학기술학회지
    • /
    • 제34권4호
    • /
    • pp.705-716
    • /
    • 2017
  • 본 연구에서는 0.5, 1.0, 1.5 wt%의 $TiO_2$를 함유하는 인듐-티타늄 수산화물을 졸 및 염기 첨가에 의해 얻었고, $200^{\circ}C$$500^{\circ}C$에서 겔화 과정을 통해 ITiO(Indium Titanate Oxide)를 얻었다. $200^{\circ}C$에서 겔화 과정 후 얻어지는 ITiO 입자가 작아서 조밀성이 있는 ITiO 타겟을 제조하였다. 0.5, 1.0, 1.5 wt%의 $TiO_2$를 함유하는 ITiO 타겟을 스퍼터링하여 ITiO 박막을 유리판위에 제작하여 비저항, 전하 이동도, 캐리어 농도를 조사하였다. 이들 박막 중에서 산소 조성이 0.4 %인 조건에서 0.5 wt% 중량% $TiO_2$를 함유하는 ITiO 타겟으로부터 제작된 ITiO 박막이 가장 낮은 비저항, 가장 큰 전하이동도 및 가장 낮은 캐리어 농도를 보임을 알 수 있었고, 얻어진 ITiO 박막의 광투과율을 측정하여 적외선 영역에서 광투과율이 ITO(Indium Tin Oxide) 박막에 비해 현저히 증가함을 발견하였다.

티타늄 첨가강의 연주 노즐막힘 기구 (Nozzle Clogging Mechanism in Continuous Casting for Titanium-Containing Steel)

  • 정우광;권오덕;조문규
    • 한국재료학회지
    • /
    • 제19권9호
    • /
    • pp.473-480
    • /
    • 2009
  • In order to provide the mechanism of nozzle clogging, recovered nozzles for high strength steel grade were examined carefully after continuous casting. The thickness of clogged material in SEN is increased in the following order: from the bottom to the top of the nozzle, upper part of slag line, and the pouring hole. Nozzle clogging material begins to form due the adhesion of metal to nozzle wall, the decarburization, and reduction of oxide in the refractory by Al and Ti in the melt. The reduction of oxide in the refractory by Al and Ti improves the wettability of the melt on the refractory and forms a thin Al-Ti-O layer. Metal containing micro alumina inclusions is solidified on the Al-Ti-O layer, and the solid layer grows due to the heat evolution through the nozzle wall. Thermodynamic calculation has been made for the related reactions. The effect of superheat to the nozzle clogging is discussed on ultra low carbon steel and low carbon steel.