• Title/Summary/Keyword: Threshold condition

Search Result 491, Processing Time 0.028 seconds

An Effect of the Jury Instruction Procedure on The Level of the Threshold for the Decision to Convict (유죄판단 역치에 대한 배심설시 절차의 효과)

  • Yoori Seong;Kwangbai Park
    • Korean Journal of Culture and Social Issue
    • /
    • v.21 no.3
    • /
    • pp.497-510
    • /
    • 2015
  • The jury instruction consists of a set of legal rules and provides a guide for jurors to interpret evidence and the legal standard of a proof beyond reasonable doubt. Jury instructions are usually given after the closing arguments (at the end of the trial). But some research has shown that jury instruction provided before the evidence may have an impact on verdict. The present study was to determine the cognitive process caused by early instruction: (1) Early instruction may influence the verdict by upwardly adjusting the threshold for the decision to convict; (2) early instruction may influence the verdict through evaluations of the probative values of evidence; (3) Or both. 187 people older than 20 years of age participated in the on-line survey. With a trial scenario, one independent variable, Instruction Procedure, was manipulated in three levels: before-and-after the evidence procedure, after-only evidence procedure, and no-instruction procedure. The instruction procedure conditions did not show any difference in the evaluation of the probative values of evidence. On the other hand, before-and-after condition showed the lowest rate of guilty verdict and the highest probability of guilt for the defendant in the scenario. This latter result clearly suggested that the instruction procedure affects the decision threshold. Specifically, instruction provided twice, once before and again after the evidence, may upwardly shift the threshold for the decision to convict.

  • PDF

Development of Rehabilitation Criteria of National Highway Pavement (국도 아스팔트 콘크리트 포장의 보수공법 결정 기준 연구)

  • Kim, Da-Hae;Kwon, Soo-Ahn;Suh, Young-Chan;Lim, Kwang-Soo
    • International Journal of Highway Engineering
    • /
    • v.11 no.2
    • /
    • pp.37-44
    • /
    • 2009
  • Currently the reasonability of threshold values for rutting and cracking does not clearly defined at the Pavement Rehabilitation Decision Tree on national highway PMS(Pavement Management System). The goal of this study is to provide the reasonable threshold values for the national highway asphalt concrete pavement rehabilitation. To achieve this goal, test section that represents typical asphalt concrete pavement of national highway was selected and pavement export were participated. Pavement condition survey has been conducted and pavement performance data at the selected roadway section were analyzed. From this study, reasonable threshold values of Pavement Rehabilitation Decision Tree were suggested based on the pavement expert's engineering judgement. In terms of crack repairs, the application of overlay after cutting is required to deteriorated area where existing crack ratio is over 35% and just overlay is required to where crack ratio is over 20%. On rutting, rut depth over 13mm is required to overlay after cutting and rut depth over 10mm is just needed to overlay.

  • PDF

FOG DETECTION OVER THE KOREAN PENINSULA DERIVED FROM SATELLITE OBSERVATIONS OF POLAR-ORBIT (MODIS) AND GEOSTATIONARY (GOES-9)

  • Yoo, Jung-Moon;Jeong, Myeong-Jae;Yoo, Hye-Lim;Rhee, Ju-Eun;Hur, Young-Min;Ahn, Myoung-Hwan
    • Proceedings of the KSRS Conference
    • /
    • v.2
    • /
    • pp.664-667
    • /
    • 2006
  • Seasonal threshold values for fog detection over the ten airport areas in the Korean Peninsula have been derived, using the satellite-observed data of polar-orbit (Aqua/Terra MODIS) and geostationary (GOES-9) during two years. The values are obtained from reflectance at 0.65 ${\mu}m$ $(R_{0.65})$ and the difference in brightness temperature between 3.7 ${\mu}m$ and 11 ${\mu}m$ $(T_{3.7-11})$. In order to examine the discrepancy between the threshold values of two kinds of satellites, the following parameters have been analyzed under the condition of daytime/nighttime and fog/clear-sky, utilizing their simultaneous observations over the Seoul Metropolitan Area. The parameters are the brightness temperature at 3.7 ${\mu}m$ $(T_{3.7})$, the temperature at 11 ${\mu}m$ $(T_{11})$, and $T_{3.7-11}$ for day and night. The $R_{0.65}$ data are additionally included in the daytime. The GOES-9 thresholds over the nine airport areas except the Cheongju airport have revealed the accuracy of 60% in the daytime and 70% in the nighttime, based on statistical verification as follows; FAR, POD and CSI. However, the accuracy decreases in the foggy cases with twilight, precipitation, short persistence, or the higher cloud above fog.

  • PDF

Laboratory Measurement to Provide Threshold of Visibility for Terrestrial 4K-UHDTV Broadcasting based on HEVC over DVB-T2 (HEVC over DVB-T2 기반 지상파 4K-UHDTV 방송을 위한 양시청 기준값 실험실 테스트 결과)

  • Jeon, Sungho;Kim, Sanghoon;Hahm, Sangjin;Yim, Zungkon;Suh, Young-Woo
    • Journal of Broadcast Engineering
    • /
    • v.21 no.4
    • /
    • pp.506-514
    • /
    • 2016
  • In this study, HEVC over DVB-T2 systems with a bandwidth of 6 MHz is considered, particularly for the terrestrial 4K-UHDTV broadcasting service in the Republic of Korea. The threshold of visibility carrier-to-noise power ratio (ToV C/N) and the receiver minimum required input level (sensitivity) for satisfying the subjective picture failure (SPF) condition are measured in the laboratory. It is observed, for transmitting 26.37 Mbps data stream correctly, that ToV C/N is 18.8 dB on average, and the receiver sensitivity is varied from minimum -84.2 dBm to maximum -80.0 dBm. Based on the results, the receiver noise floor is calculated by -100 dBm on average.

Driving Characteristics of Flexible Reflective Display Using Carbon Nanotube Electrode (탄소나노튜브 전극을 이용한 플렉시블 반사형 디스플레이의 구동 특성)

  • Hwang, In-Sung;Kim, Young-Cho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.6
    • /
    • pp.451-455
    • /
    • 2012
  • To compare an electrical and optical characteristics of indium tin oxide (ITO) and carbon nanotube (CNT) electrode on flexible and reflective display, we fabricate two charged particle-type display panels under the same panel condition of which the width of ribs is 10 ${\mu}m$, the cell size is $300{\mu}m{\times}300{\mu}m$, the q/m value of the white particles is -4.3 ${\mu}C/g$ and that for the black is +1.3 ${\mu}C/g$, and the cell gap is 75 ${\mu}m$, 125 ${\mu}m$, and 175 ${\mu}m$. We use plastic substrates coated with ITO and CNT electrode. To evaluate optical property, we measure a response time of particles using a laser and a photodiode. Threshold and driving voltages of CNT electrode according to the sheet resistance of 300, 600, 1,000 (ohm/sq) are compared with ITO electrode of 10 (ohm/sq). A response time of the CNT panel is similar to that of ITO panel, but the threshold and driving voltages of CNT panel are higher than that of ITO panel, inducing a large bombardment of the particles and shortening the lifetime of the panel. High difference of a threshold and a driving voltage of CNT panel will induce an particle clumping, resulting degradation of the panel. A bending radius of the fabricated CNT panel is 18 ${\mu}m$.

Self-healing capacity of damaged rock salt with different initial damage

  • Chen, Jie;Kang, Yanfei;Liu, Wei;Fan, Jinyang;Jiang, Deyi;Chemenda, Alexandre
    • Geomechanics and Engineering
    • /
    • v.15 no.1
    • /
    • pp.615-620
    • /
    • 2018
  • In order to analyze the healing effectiveness of rock salt cracks affected by the applied stresses and time, we used the ultrasonic technology to monitor the ultrasonic pulse velocity (UPV) variations for different initial stress-damaged rock salts during self-healing experiments. The self-healing experiments were to create different conditions to improve the microcracks closure or recrystallized, which the self-healing effect of damaged salt specimens were analyzed during the recovery period about 30 days. We found that: The ultrasonic pulse velocity of the damaged rock salts increases rapidly during the first 9 days recovery, and the values gradually increase to reach constant values after 30 days. The damaged value and the healed value were identified based on the variation of the wave velocity. The damaged values of the specimens that are subject to higher initial damage stress are still keeping in large after 30 days recovery under the same recovery condition It is interesting that the damage and the healing were not in the linear relationship, and there also existed a damage threshold for salt cracks healing ability. When the damage degree is less than the threshold, the self-healing ratio of rock salt is increased with the increase in damage degree. However, while the damage degree exceeds the threshold, the self-healing ratio is decreased with the increase in damage.

A Basic Study on Acoustic Conditioning of Fish Suitable for a Marine Ranch -1. The Sound Sensitivity of Japanese Parrot Fish Oplegnathus fasciatus- (해양목장 대상 어류의 음향순치에 관한 기초적 연구 -1. 돌돔의 청각 특성-)

  • Kim Seong Ho;Lee Chang Heon;Seo Du Ok;Kim Yong Ju
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.35 no.6
    • /
    • pp.563-567
    • /
    • 2002
  • Developing base data on luring fish schools into netting position by the use of underwater audible sound on japanese parrot fish Oplegnathus fasciatus found in the coastal waters of Jeju Island, S. Korea. Auditory threshold was determined by the heartbeat condition technique using pure tones coupled with a delayed electric shock. The audible range of japanese parrot fish extended from 80 Hz to 500 Hz with a peak sensitivity at 200 Hz. The mean auditory thresholds at the frequencies of 80 Hz, 100 Hz, 200 Hz,300 Hz and 500 Hz were 104 dB, 95 dB, 91 dB, 99 dB and 113 dB, respectively. As the frequency became higher than 200 Hz, the auditory threshold increased almost linearly with increasing frequency. Critical ratios of fishes measured in the presence of masking noise in the spectrum level range of 69$\~$78 dB (0 dB re 1$\mu$Pa/$\sqrt{Hz}$) ranged from 21 dB to 40 dB at test frequencies. The noise spectrum level at the start of masking was about 70 dB within the test frequency range. The sound pressure level of 100$\~$200 Hz recognized by japanese parrot fish under the ambient noise is above 91 dB and the critical ratio for them is above 21 dB.

Fog Sensing over the Korean Peninsula Derived from Satellite Observation of MODIS and GOES-9

  • Yoo, Jung-Moon;Jeong, Myeong-Jae;Yoo, Hye-Lim;Rhee, Ju-Eun;Hur, Young-Min;Ahn, Myoung-Hwan
    • Korean Journal of Remote Sensing
    • /
    • v.22 no.5
    • /
    • pp.373-377
    • /
    • 2006
  • Seasonal threshold values for fog detection over the ten airport areas in the Korean Peninsula have been derived, using the satellite-observed data of polar-orbit (Aqua/Terra MODIS) and geostationary (GOES-9) during two years. The values are obtained from reflectance at $0.65{\mu}m\;(R_{0.65})$ and the difference in brightness temperature between $3.7{\mu}m\;and\;11{\mu}m\;(T_{3.7-11})$. In order to examine the discrepancy between the threshold values of two kinds of satellites, the following parameters have been analyzed under the condition of daytime/nighttime and fog/clear-sky, utilizing their simultaneous observations over the Seoul Metropolitan Area. The parameters are the brightness temperature at $3.7{\mu}m\;(T_{3.7})$, the temperature at $11{\mu}m\;(T_{11}$, and $T_{3.7-11}$ for day and night. The $R_{0.65}$ data are additionally included in the daytime. The GOES-9 thresholds over the seven airport areas except the Cheongju airport have revealed the accuracy of 50% in the daytime and 70% in the nighttime, based on statistical verification for the independent samples as follows; FAR, POD and CSI. However, the accuracy decreases in the foggy cases with twilight, precipitation, short persistence, or the higher cloud above fog.

Performance Analysis of Mode Switching Scheme for Reduction of Phase Distortion in GPS Anti-jamming Equipment Based on STAP Algorithm

  • Jung, Junwoo;Yang, Gi-Jung;Park, Sungyeol;Kang, Haengik;Kwon, Seungbok;Kim, Kap Jin
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.8 no.3
    • /
    • pp.95-105
    • /
    • 2019
  • A method that applies space-time adaptive signal processing (STAP) algorithm based on an array antenna consisting of multiple antenna elements has been known to be effective to remove wide-band jamming signals in GPS receivers. However, the occurrence of phase distortion in navigation signals has been a problem when navigation signals, from which jamming signals are removed using STAP, are supplied to global positioning system (GPS) receivers. This paper verified the navigation performance degradation as a result of phase distortion. To mitigate this phenomenon, this paper proposes a mode switching scheme, in which a bypass mode is adopted to make the best use of the tracking performance of receivers without performing signal processing when jamming signals are not present or weak, and a STAP mode is employed when jamming signals exceed the threshold value. In this paper, the mode switching scheme is proposed for two environments: when receivers are stationary, and when receivers are moving. This paper confirmed that the performance of position error improved because phase distortion could be excluded due to STAP if the bypass mode was adopted under a condition where the jamming signal power level was below the threshold value in an environment where receivers were stationary. However, this paper also observed that the navigation failed due to the instability of tracking performance of receivers due to phase distortion that occurred at the switching time, although the number of switching could be reduced dramatically by proposing a dual threshold scheme of on- and off-thresholds that switched a mode due to the array antenna characteristics of varying gains according to the jamming signal incident direction in an environment where receivers were moving. The analysis results verified that running the STAP algorithm at all times is more efficient than the mode switching, in terms of maintaining stable navigation and ensuring position error performance, to remove jamming signals in an environment where receivers were moving.

Masking Level Difference: Performance of School Children Aged 7-12 Years

  • de Carvalho, Nadia Giulian;do Amaral, Maria Isabel Ramos;de Barros, Vinicius Zuffo;dos Santos, Maria Francisca Colella
    • Journal of Audiology & Otology
    • /
    • v.25 no.2
    • /
    • pp.65-71
    • /
    • 2021
  • Background and Objectives: In masking level difference (MLD), the masked detection threshold for a signal is determined as a function of the relative interaural differences between the signal and the masker. Study 1 analyzed the results of school-aged children with good school performance in the MLD test, and study 2 compared their results with those of a group of children with poor academic performance. Subjects and Methods: Study 1 was conducted with 47 school-aged children with good academic performance (GI) and study 2 was carried out with 32 school-aged children with poor academic performance (GII). The inclusion criteria adopted for both studies were hearing thresholds within normal limits in basic audiological evaluation. Study 1 also considered normal performance in the central auditory processing test battery and absence of auditory complaints and/or of attention, language or speech issues. The MLD test was administered with a pure pulsatile tone of 500 Hz, in a binaural mode and intensity of 50 dBSL, using a CD player and audiometer. Results: In study 1, no significant correlation was observed, considering the influence of the variables age and sex in relation to the results obtained in homophase (SoNo), antiphase (SπNo) and MLD threshold conditions. The final mean MLD threshold was 13.66 dB. In study 2, the variables did not influence the test performance either. There was a significant difference between test results in SπNo conditions of the two groups, while no differences were found both in SoNo conditions and the final result of MLD. Conclusions: In study 1, the cut-off criterion of school-aged children in the MLD test was 9.3 dB. The variables (sex and age) did not interfere with the MLD results. In study 2, school performance did not differ in the MLD results. GII group showed inferior results than GI group, only in SπNo condition.