• 제목/요약/키워드: Threshold Level

검색결과 1,279건 처리시간 0.026초

주파수와 타이밍 옵셋에 의한 빠른 주파수 호핑 시스템의 임계값 분석 (Threshold level analysis of the FFH-MA system using noncoherent FSK modulation under the presence of frequency and timing offsets)

  • Jeungmin Joo;Yeomin Yoon;Miheung Choe;Lee, Kwangeog;Kim, Kiseon
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 하계종합학술대회 논문집 I
    • /
    • pp.226-229
    • /
    • 2003
  • Under the prsence of the frequency and timing offset, we evaluate the BER performance of the FFH-MA system using noncoherent M-ary FSK modulation in the Rayleigh fading channel. The numerical resuts show that while the frequency and timing offset increases at a given SNR, the BER is severely degraded. The threshold level used in the envelope detector increases with the increase of the frequency and timing offset, and with the proper selection of the threshold level, the BER can be improved under the presence of such offsets.

  • PDF

한방 복합 치료 및 소리재활치료로 호전된 양측성 돌발성 난청 치험 1례 (Therapeutic Effects of Korean Medical Treatment Combined with Threshold Sound Conditioning on Bilateral Sudden Sensorineural Hearing Loss : A Case Report)

  • 박소영;제하경;민예은;강준혁;홍은빈
    • 한방안이비인후피부과학회지
    • /
    • 제35권2호
    • /
    • pp.72-81
    • /
    • 2022
  • Objectives : The purpose of this study is to report the case of a bilateral sudden sensorineural hearing loss patient whose hearing had improved by Korean medical treatment combined with threshold sound. Methods : A woman diagnosed with bilateral sudden sensorineural hearing loss has treated with Korean medical interventions(acupuncture combined with electromagnetic stimulation and pharmacoacupuncture) and threshold sound conditioning(TSC) for 20 weeks. Pure tone audiometry(PTA) was performed for the evaluation. Results : The average hearing level has improved from mild to normal level. The level of tinnitus has decreased from VAS 10 to VAS 4. Conclusions : We observed an improvement in a bilateral sudden sensorineural hearing loss patient's hearing and hereby suggest the possibility of Korean medical treatment and TSC's ameliorating effect on sensorineural hearing loss.

Effect of Cochlear Implant Electrode Array Design on Electrophysiological and Psychophysical Measures: Lateral Wall versus Perimodiolar Types

  • Lee, Ji Young;Hong, Sung Hwa;Moon, Il Joon;Kim, Eun Yeon;Baek, Eunjoo;Seol, Hye Yoon;Kang, Sihyung
    • Journal of Audiology & Otology
    • /
    • 제23권3호
    • /
    • pp.145-152
    • /
    • 2019
  • Background and Objectives: The present study aims to investigate whether the cochlear implant electrode array design affects the electrophysiological and psychophysical measures. Subjects and Methods: Eighty five ears were used as data in this retrospective study. They were divided into two groups by the electrode array design: lateral wall type (LW) and perimodiolar type (PM). The electrode site was divided into three regions (basal, medial, apical). The evoked compound action potential (ECAP) threshold, T level, C level, dynamic range (DR), and aided air conduction threshold were measured. Results: The ECAP threshold was lower for the PM than for the LW, and decreased as the electrode site was closer to the apical region. The T level was lower for the PM than for the LW, and was lower on the apical region than on the other regions. The C level on the basal region was lower for the PM than for the LW whereas the C level was lower on the apical region than on the other regions. The DRs on the apical region was greater for the PM than for the LW whereas the DR was narrower on the apical region than on the other regions. The aided air conduction threshold was not different for the electrode design and frequency. Conclusions: The current study would support the advantages of the PM over the LW in that the PM had the lower current level and greater DR, which could result in more localized neural stimulation and reduced power consumption.

Effect of Cochlear Implant Electrode Array Design on Electrophysiological and Psychophysical Measures: Lateral Wall versus Perimodiolar Types

  • Lee, Ji Young;Hong, Sung Hwa;Moon, Il Joon;Kim, Eun Yeon;Baek, Eunjoo;Seol, Hye Yoon;Kang, Sihyung
    • 대한청각학회지
    • /
    • 제23권3호
    • /
    • pp.145-152
    • /
    • 2019
  • Background and Objectives: The present study aims to investigate whether the cochlear implant electrode array design affects the electrophysiological and psychophysical measures. Subjects and Methods: Eighty five ears were used as data in this retrospective study. They were divided into two groups by the electrode array design: lateral wall type (LW) and perimodiolar type (PM). The electrode site was divided into three regions (basal, medial, apical). The evoked compound action potential (ECAP) threshold, T level, C level, dynamic range (DR), and aided air conduction threshold were measured. Results: The ECAP threshold was lower for the PM than for the LW, and decreased as the electrode site was closer to the apical region. The T level was lower for the PM than for the LW, and was lower on the apical region than on the other regions. The C level on the basal region was lower for the PM than for the LW whereas the C level was lower on the apical region than on the other regions. The DRs on the apical region was greater for the PM than for the LW whereas the DR was narrower on the apical region than on the other regions. The aided air conduction threshold was not different for the electrode design and frequency. Conclusions: The current study would support the advantages of the PM over the LW in that the PM had the lower current level and greater DR, which could result in more localized neural stimulation and reduced power consumption.

헤드폰을 이용한 가청역치레벨의 측정 방법 비교 (Comparison of a hearing threshold level using a headphone)

  • 김득성;장서일;김동준;이연수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.796-801
    • /
    • 2007
  • This research presents a laboratory study about a comparison between two methods that measure a hearing threshold of the Subjects who participated in an experiment of the Jury test. The Subjects heard a signal by a headphone. The Subjects of total 63 persons (man=42, woman=21 persons) participated in an experiment. A test of hearing was divided into two (Top-Down, Bottom-Up) methods. Total time of hearing test was about 80 minute(40min/day). As a results of the hearing test, a hearing threshold of the Subjects who used to wear a headphone was higher than that of the Subjects who not used to wear a headphone. A hearing threshold of a man was higher than that of a woman. The result of hearing test was showed that ISO's hearing threshold(MAF) was lower than a result that get from an experiment.

  • PDF

An Algorithm for Bit Error Rate Monitoring and Adaptive Decision Threshold Optimization Based on Pseudo-error Counting Scheme

  • Kim, Sung-Man
    • Journal of the Optical Society of Korea
    • /
    • 제14권1호
    • /
    • pp.22-27
    • /
    • 2010
  • Bit error rate (BER) monitoring is the ultimate goal of performance monitoring in all digital transmission systems as well as optical fiber transmission systems. To achieve this goal, optimization of the decision threshold must also be considered because BER is dependent on the level of decision threshold. In this paper, we analyze a pseudo-error counting scheme and propose an algorithm to achieve both BER monitoring and adaptive decision threshold optimization in optical fiber transmission systems. To verify the effectiveness of the proposed algorithm, we conduct computer simulations in both Gaussian and non-Gaussian distribution cases. According to the simulation results, BER and the optimum decision threshold can be estimated with the errors of < 20% and < 10 mV, respectively, within 0.1-s processing time in > 40-Gb/s transmission systems.

맨체스터 부호로 코딩된 하향신호의 재변조를 이용한 광가입자 망에서 상향속도개선을 위한 임계치의 설정 (Threshold Level Setting of a Receiver in Optical Subscriber Network with Manchester Coded Downstream and NRZ Upstream Re-modulation for the Improvement of Upstream Data Ratios)

  • 박상조
    • 한국컴퓨터정보학회논문지
    • /
    • 제16권12호
    • /
    • pp.175-185
    • /
    • 2011
  • 대화형 멀티 미디어 서비스와 요구 오차율에 따라 상향속도와 광송신전력을 설정하는 광가입자망에서 시스템의 단순화 및 상향속도 개선을 위해 임계치의 설정을 분석한다. 상향과 하향 데이터 속도비가 1:1/2, 1:1/4, 1:1/8, 1:1/16인 맨체스터 부호로 코딩된 하향신호의 재변조를 이용한 비대칭 광 가입자망에서 4가지 하향 데이터의 형태에 따라서 재변조한 상향신호의 평균오차율을 이론적으로 분석하여, 매트랩을 이용한 시뮬레이션으로 수치 결과를 분석한다. 상하향 데이터 속도비가 1:1/16, 1/8 및 1/4 의 경우 광수신전력에 관계없이 최적 임계치를 사용한 광수신기 보다 성능을 크게 악화시키지 않고 임계치가 1/2인 종래의 광수신기를 적용할 수 있음을 알 수 있다. 상하향 데이터 속도비가 1:1/2의 경우 광 수신기의 임계치를 1/3로 고정시키고 평균 광수신전력이 증가하면 최적 임계치를 사용한 광수신기 보다 성능을 크게 악화시키지 않음을 알 수 있다.

저빈도-고강도 경피신경전기자극이 혈장 $\beta-endorphin$ 과 ACTH, 혈청 Cortisol 및 요중 17-OHCS 농도에 미치는 영향 (Effect of Acupuncture-like Transcutaneous Electrical Nerve Stimulation on Plasma $\beta-endorphin$ and ACTH, Serum Cortisol and Urinary 17-OHCS Levels)

  • 박춘서;이재형
    • The Journal of Korean Physical Therapy
    • /
    • 제6권1호
    • /
    • pp.5-15
    • /
    • 1994
  • The purpose of this study was to examine the effect of electroanalgeia and $\beta-endorphin$ action by acupuncture-like (Lof/Hil) transcutaneous electrical nerve stimulation (TENS) applied to acupuncture points. Twelve healthy adult male aged between 19 ann 25 were randomly assigned to TENS group (n=6) and naloxone group (n=6). Subjects of both groups were strongly stimulated TENS with 4 pps and $200{\mu}s$ for 30 minutes on the LI 3 and LI 10 meridian points of dominant am. Naloxone group was injected naloxone hydrochloride before TENS application. The experimental pain threshold was measured by chronaxie meter CX-2 on the distal end of radius just before and after TENS application. The levels of plasma $\beta-endorphin$ and ACTH. serum cortisol and urinary 17-OHCS were analyzed by radioimmunoassay (RIA) kits before and after TENS application. In TENS group, there was a significant increase of experimental pain threshold (p<0.01), plasma $\beta-endorphin$ level (p<0.05), serum cortisol level (p<0,001) and urinary 17-OHCS levels (p<0.05) after TENS application. The plasma ACTH level was not significantly increased, but it showed an increasing tendency. In naloxone group, although there was a decreasing trend, ACTH and cortisol level did not show a significant change, but $\beta-endorphin$ and 17-OHCS level were significantly decreased (p<0.01). The result of this study stewed that acupuncture-like TENS induced analgesic effect, such that the levels of plasma $\beta-endorphin$, plasma ACTH, serum cortisol and urinary 17-OHCS were concomitantly increased with experimental pain threshold. It is suggested that the analgesic mechanism of the acupuncture-like TENS probably related to endogenous opioid component such as $\beta-endorphin$.

  • PDF

FPGA based Dynamic Thresholding Circuit

  • Cho, J.U.;Lee, S.H.;Jeon, J.W.;Kim, J.T.;Cho, J.D.;Lee, K.M.;Lee, J.H.;Byun, J.E.;Choi, J.C.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.1235-1238
    • /
    • 2004
  • Thresholding has been used to reduce the number of gray values in images. Typically, a single threshold value has been used, resulting in two gray level images. Image reduction of one single threshold value, however, may lose too much of the high-frequency edge information. Thus, dynamic thresholding that uses a different threshold for each pixel is preferred instead of using a single threshold value. Dynamic thresholding can preserve high frequency details as well as reduce the size of images. Since it takes long time to perform existing software dynamic thresholding in an embedded system, this paper proposes and implements a circuit by using a FPGA in order to perform a real-time dynamic thresholding,. The proposed circuit consists of two counters, and threshold look-up table, and control unit. The values of two counters determine each pixel position, the threshold look-up table converts each pixel value into other value, and the control unit generates necessary control signals. On arriving from a camera to the proposed circuit, each pixel is compared with its threshold value and is converted into other gray value. An image processing system by using the proposed circuit will be implemented and some experiments will be performed.

  • PDF

가우시안형 유한 혼합 분포에 기반한 다중 임계값 결정법 (Multilevel Threshold Selection Method Based on Gaussian-Type Finite Mixture Distributions)

  • 서석태;이인근;정혜천;권순학
    • 한국지능시스템학회논문지
    • /
    • 제17권6호
    • /
    • pp.725-730
    • /
    • 2007
  • Otsu의 임계값 결정법, Huang와 Wang의 임계값 결정법 등을 포함한 그레이 레벨 히스토그램에 기반한 임계값 결정법은 영상처리 분야에서 널리 사용되어져 왔다. 이들 기법들은 그 효용성이 뛰어남에도 불구하고 하나의 임계값이 아닌 다중 임계값을 추출하는 경우 많은 연산 시간이 소요되는 단점을 가지고 있다. 즉, 임계값의 개수가 늘어남에 따라 연산 복잡도 역시 기하급수적으로 증가하게 된다 본 논문에서는 가우시안 함수를 이용하여 그레이 레벨간의 상관관계를 측정하고, 가우시안 분포함수와 그레이 레벨의 히스토그램을 결합한 가우시안형 유한 혼합 분포를 이용하여 연산 복잡도가 단순하며 효용성 있는 임계값 결정법을 제안한다. 다수의 영상에 제안한 기법을 적용한 모의실험을 통하여 효용성을 확인하고, Otsu의 임계값 결정법과 제안한 기법의 연산 복잡도 비교를 통해서 제안한 임계값 결정법의 효율성을 보인다.