• Title/Summary/Keyword: Three-input

Search Result 2,946, Processing Time 0.035 seconds

High-powerfactor Control of Boost-type Rectifier without input Current Sensing (입력전류의 검출이 없는 승압형 정류기의 고역률제어)

  • Bae, Chang-Han;Lee, Gyo-Beom;Song, Jung-Ho;Lee, Gwang-Un
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.9
    • /
    • pp.510-516
    • /
    • 1999
  • In this paper, a new high-powerfactor control method for boost-type rectifier is proposed, which removes the necessity of input current sensing. This method generates a sinewave duty template only from the line voltage waveform and rectifier output, and reduces reactive power remarkably utilizing three compensation coefficients which are determined through experiments. These compensations make the input current to be in phase with the input voltage all over the load range. A prototype boost-type rectifier is designed and experimental results are presented.

  • PDF

Optimizing Artificial Neural Network-Based Models to Predict Rice Blast Epidemics in Korea

  • Lee, Kyung-Tae;Han, Juhyeong;Kim, Kwang-Hyung
    • The Plant Pathology Journal
    • /
    • v.38 no.4
    • /
    • pp.395-402
    • /
    • 2022
  • To predict rice blast, many machine learning methods have been proposed. As the quality and quantity of input data are essential for machine learning techniques, this study develops three artificial neural network (ANN)-based rice blast prediction models by combining two ANN models, the feed-forward neural network (FFNN) and long short-term memory, with diverse input datasets, and compares their performance. The Blast_Weathe long short-term memory r_FFNN model had the highest recall score (66.3%) for rice blast prediction. This model requires two types of input data: blast occurrence data for the last 3 years and weather data (daily maximum temperature, relative humidity, and precipitation) between January and July of the prediction year. This study showed that the performance of an ANN-based disease prediction model was improved by applying suitable machine learning techniques together with the optimization of hyperparameter tuning involving input data. Moreover, we highlight the importance of the systematic collection of long-term disease data.

Application of Piezoelectric Smart Structures for Statistical Energy Analysis (압전 지능 구조물을 이용한 통계적 에너지 해석 기법)

  • 김재환;김정하;김재도
    • Journal of KSNVE
    • /
    • v.11 no.2
    • /
    • pp.257-264
    • /
    • 2001
  • In this research, piezoelectric smart structures are applied for SEA(Statistical Energy Analysis), which is well known approach for high frequency analysis. A new input power measurement based on piezoelectric electrical power measurement is proposed and compared with the conventional method in SEA. As an example, a simple aluminum beam on which piezoelectric actuator is attached is considered. By measuring the electrical impedance and electrical current of the piezoelectric actuator, the electrical power given on the actuator is found and this is In turn converted into the mechanical energy. From the measured value of the stored energy of the beam, the Internal loss factor is calculated and this value shows a good agreement with that given by the conventional method as well as the theoretical value. To compare the coupling loss factor, L-shape beam system which consists of a aluminum beam subsystem and a steel beam subsystem coupled by three pin is taken as second example. The input power and stored energy of each subsystem are found by the proposed approach. The coupling loss factor found by the electrical input power obtained from the piezoelectric actuator exhibits similar trend to the value found by the conventional method as well as the theoretical value. In conclusion, the use of SEA for high frequency application of piezoelectric smart structures is Possible. Especially, the input power that is essential for SEA can be found accurately by measuring the electrical input power of the piezoelectric actuator.

  • PDF

Design of RCGA-based PID controller for two-input two-output system

  • Lee, Yun-Hyung;Kwon, Seok-Kyung;So, Myung-Ok
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.10
    • /
    • pp.1031-1036
    • /
    • 2015
  • Proportional-integral-derivative (PID) controllers are widely used in industrial sites. Most tuning methods for PID controllers use an empirical and experimental approach; thus, the experience and intuition of a designer greatly affect the tuning of the controller. The representative methods include the closed-loop tuning method of Ziegler-Nichols (Z-N), the C-C tuning method, and the Internal Model Control tuning method. There has been considerable research on the tuning of PID controllers for single-input single-output systems but very little for multi-input multi-output systems. It is more difficult to design PID controllers for multi-input multi-output systems than for single-input single-output systems because there are interactive control loops that affect each other. This paper presents a tuning method for the PID controller for a two-input two-output system. The proposed method uses a real-coded genetic algorithm (RCGA) as an optimization tool, which optimizes the PID controller parameters for minimizing the given objective function. Three types of objective functions are selected for the RCGA, and each PID controller parameter is determined accordingly. The performance of the proposed method is compared with that of the Z-N method, and the validity of the proposed method is examined.

A Study on the Affected of DC-Link Voltage Balance Control of the Vienna Rectifier Linked With the Input Series Output Parallel LLC Converter (직렬 입력 병렬 출력 연결된 LLC 컨버터를 갖는 비엔나 정류기의 DC 링크 전압 평형 제어에 관한 연구)

  • Baek, Seung-Woo;Kim, Hag-Wone;Cho, Kwan-Yuhl
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.3
    • /
    • pp.205-213
    • /
    • 2021
  • Due to the advantage of reducing the voltage applied to the switch semiconductor, the input series and output parallel combination is widely used in systems with high input voltage and large output current. On the other hand, the LLC converter is widely used as a high-efficiency power converter, and when connected by ISOP combination, there is a possibility that input voltage imbalance may occur due to a mismatch of passive devices. To avoid damaging the switching device, this study analyzed the DC-link voltage imbalance of a high-capacity supply using an ISOP LLC converter. In addition, the case where DC-link unbalance control was applied and the case not applied was analyzed respectively. Based on this analysis, an initial start-up algorithm was proposed to prevent input power semiconductor device damage due to DC-link over-voltage. The effectiveness of the proposed algorithm has been verified through simulations and experiments.

Analysis of Operation Parameters of Pilot-Scale Packed-Absorption System for Airborne Methyl Ethyl Ketone Control (공기 중 메틸에틸케톤 제어를 위한 Pilot-Scale 흡수 시스템의 운영인자 분석)

  • Jo, Wan-Kuen;Kim, Wang-Tae
    • Journal of Environmental Science International
    • /
    • v.20 no.4
    • /
    • pp.501-509
    • /
    • 2011
  • Unlike many laboratory-scale studies on absorption of organic compounds (VOCs), limited pilot-scale studies have been reported. Accordingly, the present study was carried out to examine operation parameters for the effective control of a hydrophilic VOC (methyl ethyl ketone, MEK) by applying a circular pilot-scale packed-absorption system (inside diameter 37 cm ${\times}$ height 167 cm). The absorption efficiencies of MEK were investigated for three major operation parameters: input concentration, water flow rate, and ratio of gas flow-rate to washing water amount (water-to-gas ratio). The experimental set-up comprised of the flow control system, generation system, recirculation system, packed-absorption system, and outlet system. For three MEK input concentrations (300, 350, and 750 ppm), absorption efficiencies approached near 95% and then, decreased gradually as the operation time increased, thereby suggesting a non-steady state condition. Under these conditions, higher absorption efficiencies were shown for lower input concentration conditions, which were consistent with those of laboratory-scale studies. However, a steady state condition occurred for two input concentration conditions (100 and 200 ppm), and the difference in absorption efficiencies between these two conditions were insignificant. As supported by an established gas-liquid absorption theory, a higher water flow rate exhibited a greater absorption efficiency. Moreover, as same with the laboratory-scale studies, the absorption efficiencies increased as water-to-gas ratios increased. Meanwhile, regardless of water flow rates or water-to-gas ratios, as the operation time of the absorption became longer, the pH of water increased, but the elevation extent was not substantial (maximum pH difference, 1.1).

Effects of Mirror Therapy Using 3D Motion Input Device on Upper Extremity Function, Quality of Life, Depression in Stroke Patients (3D 모션입력장치를 이용한 거울치료가 뇌졸중 환자의 상지 운동 기능, 삶의 질, 우울감에 미치는 영향)

  • Park, Jungwon;Choi, Hosuk;Shin, Wonseob
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.4 no.4
    • /
    • pp.41-51
    • /
    • 2016
  • PURPOSE : The purpose of this study was to identify whether 3D motion input device based mirror therapy could improve on upper extremity function, quality of life and depression in chronic stroke patients METHOD : Thirty six patients with chronic stroke were enrolled and randomly divided into three groups: 3D leapmotion mirror therapy group, mirror therapy group, and sham therapy group. 3D leapmotion mirror therapy group performed 3D motion input device based mirror therapy, mirror therapy group performed general mirror therapy, control group performed sham therapy. All patients received a total of 15 exercise session over a 5 week period (three times per week). Fugl-Meyer Assessment-upper extremity(FMA-UE), Stroke Specific-Quality of Life(SS-QOL), Beck Depression Inventory(BDI) were performed prior to and five weeks after the treatment RESULT : Subjects in the 3D leapmotion mirror therapy group showed significant improvements in upper extremity function, quality of life and depression following training. The changes of upper extremity function, quality of life and depression in the 3D leapmotion mirror therapy group were significantly more than them of the control group. CONCLUSION : The result of this study suggest that 3D motion input device based mirror therapy is an intervention to improve on upper extremity function, quality of life and depression in chronic stroke patients.

Low-Power Buck-Boost Converter for Multi-Input Energy Harvesting Systems (다중입력 에너지 하베스팅 시스템을 위한 저전력 벅-부스트 변환기)

  • Jo, Gil-Je;Kwak, Myoung-Jin;Im, Ju-An;Yu, Chong-Gun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.10a
    • /
    • pp.31-34
    • /
    • 2018
  • This paper presents a low-power buck-boost converter for multi-input energy harvesting systems. The designed circuit combines the energy harvested from three input channels in real time and stores it in a storage capacitor. The structure of the buck-boost converter is simplified by using one external inductor and applying time division technique using an arbiter. In addition, to improve the efficiency of the system, the controller circuits of the converter are designed so that current consumption is minimized. The proposed circuit is designed with $0.35{\mu}m$ CMOS process. Simulation results show that the designed circuit consumes up to 490nA of current when all three input channels are active, and the maximum power efficiency is 92%. The chip area of the designed circuit is $1310{\mu}m{\times}1100{\mu}m$.

  • PDF

Analysis of Sensitivity, Correlation Coefficient and PCA of Input and Output Parameters using Fire Modeling (화재모델링을 이용한 입출력 변수의 민감도, 상관계수 분석과 주성분 분석)

  • Nam, Gi Tae;Kim, Jeong Jin;Yoon, Seok Pyo;Kim, Jun Kyoung
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.5
    • /
    • pp.46-54
    • /
    • 2019
  • Even though the fire performance-based design concept has been introduced for various structures and buildings, which have their own specific fire performance level, the uncertainties of input parameters always exist and, then, could reduce significantly the reliability of the fire modeling. Sensitivity analysis was performed with three limited input parameters, HRRPUA, type of combustible materials, and mesh size, which are significantly important for fire modeling. The output variables are limited to the maximum HRR, the time reaching the reference temperature($60^{\circ}C$), and that to reach limited visible distance(5 m). In addition, correlation coefficient analysis was attempted to analyze qualitatively and quantitatively the degree of relation between input and output variables above. Finally, the relationship among the three variables is also analyzed by the principal component analysis (PCA) to systematically analyze the input data bias. Sensitivity analysis showed that the type of combustible materials is more sensitive to maximum HRR than the ignition source and mesh size. However, the heat release parameter of the ignition source(HRR) is shown to be much more sensitive than the combustible material types and mesh size to both time to reach the reference temperature and that to reach the critical visible distance. Since the derived results can not exclude the possibility that there is a dependency on the fire model applied in this study, it is necessary to generalize and standardize the results of this study for the fire models such as various buildings and structures.

Litterfall and Nutrient Input via Litterfall in Pinus densiflora Forest at Mt. Worak National Park (월악산 소나무림의 낙엽생산과 낙엽을 통한 영양염류 이입량)

  • NamGung, Jeong;Mun, Hyeong-Tae
    • Korean Journal of Environmental Biology
    • /
    • v.27 no.3
    • /
    • pp.261-265
    • /
    • 2009
  • Litter production, nutrient concentration of each component of litterfall and amount of nutrients input to forest floor via litterfall were investigated for three years from May 2005 through April 2008 in Pinus densiflora forest at Mt. Worak National Park. Amount of litterfall in 2005, 2006, 2007 were 3.070, 3.066, 3.099 ton $ha^{-1}yr^{-1}$, respectively. Average amount of litterfall for three years was $3.078{\pm}0.018\;ton\;ha^{-1}yr^{-1}$. Average percentage of leaf litter, branch and bark, reproductive organ and the miscellaneous for three years were 61.9, 10.4, 5.2, 22.5%, respectively. Average amount of N, P, K, Ca and Mg returned to forest floor via litterfall for three years in this P. densiflora forest were 18.014, 0.878, 4.240, 7.349 and 2.172 kg $ha^{-1}yr^{-1}$, respectively.