• 제목/요약/키워드: Three-dimensional models

검색결과 1,603건 처리시간 0.031초

Three-dimensional finite element analysis of the splinted implant prosthesis in a reconstructed mandible

  • Heo, Kyung-Hoi;Lim, Young-Jun;Kim, Myung-Joo;Kwon, Ho-Beom
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권2호
    • /
    • pp.138-146
    • /
    • 2018
  • PURPOSE. The purpose of this study was to analyze the effects of the splinted implant prosthesis in a reconstructed mandible using three-dimensional finite element analysis. MATERIALS AND METHODS. Three-dimensional finite element models were generated from a patient's computed tomography data. The patient had undergone partial resection of the mandible that covered the area from the left canine to the right condyle. The mandible was reconstructed using a fibula bone graft and dental implants. The left mandibular premolars and molars remained intact. Three types of models were created. The implant-supported prosthesis was splinted and segmented into two or three pieces. Each of these models was further subcategorized into two situations to compare the stress distribution around normal teeth and implants. Oblique loading of 300 N was applied on both sides of the mandible unilaterally. The maximum von Mises stress and displacement of the models were analyzed. RESULTS. The stress distribution of the natural mandible was more uniform than that of the reconstructed fibula. When the loading was applied to the implant prosthesis of reconstructed fibula, stress was concentrated at the cortical bone around the neck of the implants. The three-piece prosthesis model showed less uniform stress distribution compared to the others. Displacement of the components was positively correlated with the distance from areas of muscle attachment. The three-piece prosthesis model showed the greatest displacement. CONCLUSION. The splinted implant prosthesis showed a more favorable stress distribution and less displacement than the separated models in the reconstructed mandible.

Comparison of 3-D structures of Halo CMEs using cone models

  • 나현옥;문용재;장수정;이경선
    • 천문학회보
    • /
    • 제37권1호
    • /
    • pp.95.1-95.1
    • /
    • 2012
  • Halo coronal mass ejections (HCMEs) are major cause of geomagnetic storms and their three dimensional structures are important for space weather. In this study, we compare three cone models: an elliptical cone model, an ice-cream cone model, and an asymmetric cone model. These models allow us to determine the three dimensional parameters of HCMEs such as radial speed, angular width, and the angle (${\gamma}$) between sky plane and cone axis. We compare these parameters obtained from three models using 62 well-observed HCMEs from 2001 to 2002. Then we obtain the root mean square error (RMS error) between maximum measured projection speeds and their calculated projection speeds from the cone models. As a result, we find that the radial speeds obtained from the models are well correlated with one another (R > 0.84). The correlation coefficients between angular widths are less than 0.53 and those between ${\gamma}$ values are less than 0.47, which are much smaller than expected. The reason may be due to different assumptions and methods. The RMS errors of the elliptical cone model, the ice-cream cone model, and the asymmetric cone model are 213 km/s, 254 km/s, and 267 km/s, respectively. Finally, we discuss their strengths and weaknesses in terms of space weather application.

  • PDF

A reliable method for evaluating upper molar distalization: Superimposition of three-dimensional digital models

  • Nalcaci, Ruhi;Kocoglu-Altan, Ayse Burcu;Bicakci, Ali Altug;Ozturk, Firat;Babacan, Hasan
    • 대한치과교정학회지
    • /
    • 제45권2호
    • /
    • pp.82-88
    • /
    • 2015
  • Objective: The aim of this study was to evaluate the reliability of measurements obtained after the superimposition of three-dimensional (3D) digital models by comparing them with those obtained from lateral cephalometric radiographs and photocopies of plaster models for the evaluation of upper molar distalization. Methods: Data were collected from plaster models and lateral cephalometric radiographs of 20 Class II patients whose maxillary first molars were distalized with an intraoral distalizer. The posterior movements of the maxillary first molars were evaluated using lateral cephalometric radiographs (group CP), photocopies of plaster models (group PH), and digitized 3D models (group TD). Additionally, distalization and expansion of the other teeth and the degrees of molar rotation were measured in group PH and group TD and compared between the two groups. Results: No significant difference was observed regarding the amount of molar distalization among the three groups. A comparison of the aforementioned parameters between group PH and group TD did not reveal any significant difference. Conclusions: 3D digital models are reliable to assess the results of upper molar distalization and can be considered a valid alternative to conventional measurement methods.

LINAC을 이용한 뇌정위적 방사선 수술에 대한 3 차원 선량분포 (Three-Dimensional Dose Distribution for the System of Linear Accelerator-based Stereotactic Radiosurgery)

  • Suh, Tae-Suk
    • 한국의학물리학회지:의학물리
    • /
    • 제2권2호
    • /
    • pp.121-128
    • /
    • 1991
  • 뇌정위적 방사선 수술 시 정확한 3차원적 선량분포에 대한 정보가 필요한다. 3차원적 치료계획은 최적선량분포를 얻기위한 것이며 환자 데이타, 선량분포, 방사선 조사 요소들에 대한 3차원적인 관계를 다루어야만 한다. 원형 조사면에 대한 single 조사면 선량 데이타와 3차원 선량 알고리듬을 이용하여 non-coplanar moving arcs 에 대한 3차원적 선량모델이 개발되었다. 뇌정위적 방사선 수술시 3차원 선량 알고리듬의 적용과 여러경우에 대한 응용에 대하여 논의되어진다.

  • PDF

Assessment of metal artifacts in three-dimensional dental surface models derived by cone-beam computed tomography

  • Nabha, Wael;Hong, Young-Min;Cho, Jin-Hyoung;Hwang, Hyeon-Shik
    • 대한치과교정학회지
    • /
    • 제44권5호
    • /
    • pp.229-235
    • /
    • 2014
  • Objective: The aim of this study was to assess artifacts induced by metallic restorations in three-dimensional (3D) dental surface models derived by cone-beam computed tomography (CBCT). Methods: Fifteen specimens, each with four extracted human premolars and molars embedded in a plaster block, were scanned by CBCT before and after the cavitated second premolars were restored with dental amalgam. Five consecutive surface models of each specimen were created according to increasing restoration size: no restoration (control) and small occlusal, large occlusal, disto-occlusal, and mesio-occluso-distal restorations. After registering each restored model with the control model, maximum linear discrepancy, area, and intensity of the artifacts were measured and compared. Results: Artifacts developed mostly on the buccal and lingual surfaces. They occurred not only on the second premolar but also on the first premolar and first molar. The parametric values increased significantly with increasing restoration size. Conclusions: Metallic restorations induce considerable artifacts in 3D dental surface models. Artifact reduction should be taken into consideration for a proper diagnosis and treatment planning when using 3D surface model derived by CBCT in dentofacial deformity patients.

DNN과 Decoder 모델 구축을 통한 생체모방 3차원 파형 익형의 유체역학적 특성 예측 (Establishment of DNN and Decoder models to predict fluid dynamic characteristics of biomimetic three-dimensional wavy wings)

  • 김민기;윤현식;서장훈;김민일
    • 한국가시화정보학회지
    • /
    • 제22권1호
    • /
    • pp.49-60
    • /
    • 2024
  • The purpose of this study establishes the deep neural network (DNN) and Decoder models to predict the flow and thermal fields of three-dimensional wavy wings as a passive flow control. The wide ranges of the wavy geometric parameters of wave amplitude and wave number are considered for the various the angles of attack and the aspect ratios of a wing. The huge dataset for training and test of the deep learning models are generated using computational fluid dynamics (CFD). The DNN and Decoder models exhibit quantitatively accurate predictions for aerodynamic coefficients and Nusselt numbers, also qualitative pressure, limiting streamlines, and Nusselt number distributions on the surface. Particularly, Decoder model regenerates the important flow features of tiny vortices in the valleys, which makes a delay of the stall. Also, the spiral vortical formation is realized by the Decoder model, which enhances the lift.

원자로 신형핵연료 하단고정체 응력 해석 (Stress Analysis for Lower End Fitting of Advanced LWR Fuel)

  • 이상순;문연철;변영주;김형구
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.139-145
    • /
    • 2002
  • In this study, the geometric modeling has been conducted for 2 models of lower end fitting of advanced LWR fuel using three-dimensional solid modeler, Solidworks. Then, the optimization and the three-dimensional stress analysis using the finite element method has been peformed. The evaluation for the mechanical integrity of 2 models has been peformed based on the stress distribution obtained from the finite element analysis.

  • PDF

군집화 기반 3차원 애니메이션 데이터 압축 기법 (Grouping-based 3D Animation Data Compression Method)

  • 최영진;여두환;김형석;김지인
    • 한국HCI학회:학술대회논문집
    • /
    • 한국HCI학회 2008년도 학술대회 1부
    • /
    • pp.461-468
    • /
    • 2008
  • 가상현실 및 증강 현실 응용 특히 디지털 패션과 같은 응용분야에서 아바타에 여러 가지 형태의 의복을 입히고 장신구들을 장식하여 보다 현실감이 나는 3차원 애니메이션을 제작한 다음 인터넷을 통하여 개인용 컴퓨터는 물론 핸드폰 같은 휴대용 정보단말기에 표현하려는 요구가 증가하고 있다. 하지만 3차원 모델을 실감나게 표현하는데 필요한 데이터의 용량이 매우 크고 네트워크의 속도 문제와 단말기에 장착된 메모리 장치의 제한적인 성능 문제등으로 인하여, 3차원 영상의 효과적인 전송 및 실감나는 표현은 매우 어렵다. 본 논문에서는 3차원 애니메이션에서 사용되는 데이터를 압축하는데, 3차원 모델 데이터를 군집화하여 애니메이션에 필요한 저장 공간을 줄여서 휴대용 정보단말기에서도 3차원 모델을 자연스럽게 렌더링할 수 있게 하는 기법을 제안하고자 한다. 제안된 기법은 각종 디포머블 오브젝트에도 응용될 수 있으며, 기존의 정적인 형상 압축 기술과 연계하여 좀 더 높은 압축을 가능하게 할 것으로 기대된다.

  • PDF

Three Dimensional Segmentation in PCNN

  • Nishi, Naoya;Tanaka, Masaru;Kurita, Takio
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 ITC-CSCC -2
    • /
    • pp.802-805
    • /
    • 2002
  • In the three-dimensional domain image expressed with two-dimensional slice images, such as fMRI images and multi-slice CT images, we propose the three-dimensional domain automatic segmentation for the purpose of extracting region. In this paper, we segmented each domain from the fMRI images of the head of people and monkey. We used the neural network "Pulse-Coupled Neural Network" which is one of the models of visual cortex of the brain based on the knowledge from neurophysiology as the technique. By using this technique, we can segment the region without any learning. Then, we reported the result of division of each domain and extraction to the fMRI slice images of human's head using "three-dimensional Pulse-Coupled Neural Network" which is arranged and created the neuron in the shape of a three-dimensional lattice.

  • PDF

허브와 중앙스팬 사이의 회전익 후류 3차원 난류유동해석에 관한 연구 (A study on the three dimensional turbulent flow analysis of wake flow behind rotating blade row between hub and midspan)

  • 노수혁;조강래
    • 대한기계학회논문집B
    • /
    • 제21권7호
    • /
    • pp.911-918
    • /
    • 1997
  • The turbulent viscous wake flows behind a single airfoil, two-dimensional stationary blade row and three-dimensional rotating blade row were calculated, and the numerical results were compared with experimental ones. The numerical technique was based on the SIMPLE algorithm using three turbulent closure models, standard k-.epsilon. model(WFM), low Reynolds number k-.epsilon. model(LRN) and Reynolds stress model (RSM). In the case of a single airfoil, WFM, LRN and RSM presented fairly good velocity distributions in the wake compared with experimental data. In the case of the stationary blade row, LRN and RSM presented better results than WFM for wake velocity distribution, and especially LRN showed best results among these three turbulent models. In the case of the rotating blade row, WFM and LRN showed fairly good agreement with experimental data of the three-dimensional velocity component distributions in the range from hub to mid span region. LRN was also superior to WFM in accuracy of prediction for the wake velocity distribution as same with the cases of a airfoil and the stationary blade row.