• Title/Summary/Keyword: Three-dimensional image analysis

Search Result 459, Processing Time 0.026 seconds

Use of the surface-based registration function of computer-aided design/computer-aided manufacturing software in medical simulation software for three-dimensional simulation of orthognathic surgery

  • Kang, Sang-Hoon;Lee, Jae-Won;Kim, Moon-Key
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.39 no.4
    • /
    • pp.197-199
    • /
    • 2013
  • Three-dimensional (3D) computed tomography image models are helpful in reproducing the maxillofacial area; however, they do not necessarily provide an accurate representation of dental occlusion and the state of the teeth. Recent efforts have focused on improvement of dental imaging by replacement of computed tomography with other detailed digital images. Unfortunately, despite the advantages of medical simulation software in dentofacial analysis, diagnosis, and surgical simulation, it lacks adequate registration tools. Following up on our previous report on orthognathic simulation surgery using computer-aided design/computer-aided manufacturing (CAD/CAM) software, we recently used the registration functions of a CAD/CAM platform in conjunction with surgical simulation software. Therefore, we would like to introduce a new technique, which involves use of the registration functions of CAD/CAM software followed by transfer of the images into medical simulation software. This technique may be applicable when using various registration function tools from different software platforms.

Image Fusion and Evaluation by using Mapping Satellite-1 Data

  • Huang, He;Hu, Yafei;Feng, Yi;Zhang, Meng;Song, DongSeob
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.31 no.6_2
    • /
    • pp.593-599
    • /
    • 2013
  • China's Mapping Satellite-1, developed by the China Aerospace Science and Technology Corporation (CASC), was launched in three years ago. The data from Mapping Satellite-1 are able to use for efficient surveying and geometric mapping application field. In this paper, we fuse the panchromatic and multispectral images of Changchun area, which are obtained from the Mapping Satellite-1, the one that is the Chinese first transmission-type three-dimensional mapping satellite. The four traditional image fusion methods, which are HPF, Mod.IHS, Panshar and wavelet transform, were used to approach for effectively fusing Mapping Satellite-1 remote sensing data. Subsequently we assess the results with some commonly used methods, which are known a subjective qualitative evaluation and quantitative statistical analysis approach. Consequently, we found that the wavelet transform remote sensing image fusion is the optimal in the degree of distortion, the ability of performance of details and image information availability among four methods. To further understand the optimal methods to fuse Mapping Satellite-1 images, an additional study is necessary.

Application of 3-D Scanner to Analysis of Functional Instability of the Ankle

  • Han, Cheng-Chun;Kubo, Masakazu;Matsusaka, Nobuou;Ishimatsu, Takakazu
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1971-1975
    • /
    • 2003
  • This paper describes a technique, which analyzes the functional instability of the ankle using three-dimensional scanner. The technique is based on the structured light pattern projection method, which is performed by using one digital still camera and one LCD projector. This system can be easily realized with the low cost. The measuring result has high accuracy. The measuring error is about 0.2 mm or less. Using this technique the three-dimensional posture of the leg and foot of the target person are measured and analyzed.

  • PDF

Fiber Orientation in Injection-Molded Short Fiber Composites with a Confocal Laser Scanning Microscope and Numerical Simulation (공초점 레이저 주사 현미경을 이용한 단섬유 복합재료 사출 성형물 내의 섬유 배열 측정 및 수치모사)

  • Lee, Kwang-Seok;Le, Seok-Won;Youn, Jae-Ryoun
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2001.05a
    • /
    • pp.201-204
    • /
    • 2001
  • A Confocal Laser Scanning Microscope (CLSM) is applied to determine three-dimensional fiber orientation states in injection-molded short fiber composites. Since the CLSM optically sections the composites, more than two planes either on or below the surface of composites can be obtained. Therefore, three dimensional fiber orientation states are determined without destruction. To predict the orientation states, velocity and temperature fields are calculated by using a hybrid FEM/FDM method. The change of orientation state during packing stage is also considered by employing a compressible Hele-Shaw model. The predicted orientation states show good agreement with measured ones. However, some differences are found at the end of cavity. They may result from other effects, which are not considered in the numerical analysis.

  • PDF

Three-Dimensional Shape Measurement of a Specular Object by LED Array Reflection (LED Array의 반사영상에 의한 경면체의 3차원 형상 측정)

  • Kim, Jee Hong
    • Korean Journal of Optics and Photonics
    • /
    • v.27 no.1
    • /
    • pp.41-46
    • /
    • 2016
  • An optical method to measure the three-dimensional (3D) shape of a surface with specular reflection is proposed. The proposed method is based on the analysis of the geometric path of the light from a point source, and the relative displacements of points in the reflection image. The 3D shape of a concave mirror is shown to be determined approximately via experiments, where the vision system consists of LED array illumination, a half-mirror, and an imaging sensor.

Assessing the Impact of Defacing Algorithms on Brain Volumetry Accuracy in MRI Analyses

  • Dong-Woo Ryu;ChungHwee Lee;Hyuk-je Lee;Yong S Shim;Yun Jeong Hong;Jung Hee Cho;Seonggyu Kim;Jong-Min Lee;Dong Won Yang
    • Dementia and Neurocognitive Disorders
    • /
    • v.23 no.3
    • /
    • pp.127-135
    • /
    • 2024
  • Background and Purpose: To ensure data privacy, the development of defacing processes, which anonymize brain images by obscuring facial features, is crucial. However, the impact of these defacing methods on brain imaging analysis poses significant concern. This study aimed to evaluate the reliability of three different defacing methods in automated brain volumetry. Methods: Magnetic resonance imaging with three-dimensional T1 sequences was performed on ten patients diagnosed with subjective cognitive decline. Defacing was executed using mri_deface, BioImage Suite Web-based defacing, and Defacer. Brain volumes were measured employing the QBraVo program and FreeSurfer, assessing intraclass correlation coefficient (ICC) and the mean differences in brain volume measurements between the original and defaced images. Results: The mean age of the patients was 71.10±6.17 years, with 4 (40.0%) being male. The total intracranial volume, total brain volume, and ventricle volume exhibited high ICCs across the three defacing methods and 2 volumetry analyses. All regional brain volumes showed high ICCs with all three defacing methods. Despite variations among some brain regions, no significant mean differences in regional brain volume were observed between the original and defaced images across all regions. Conclusions: The three defacing algorithms evaluated did not significantly affect the results of image analysis for the entire brain or specific cerebral regions. These findings suggest that these algorithms can serve as robust methods for defacing in neuroimaging analysis, thereby supporting data anonymization without compromising the integrity of brain volume measurements.

DEM Estimation Using Two Stage Stereo Matching Method (2단계 스테레오 정합기법을 이용한 DEM 추정)

  • Nam, Chang-Woo;Woo, Dong-Min
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.49 no.12
    • /
    • pp.659-666
    • /
    • 2000
  • A stereo matching has been an important tool for reconstructing three dimensional terrain. By using stereo matching technique, DEM(Digital Elevaton Map) can be generated by the disparity from a reference image to a target image. Generally disparity map can be evaluated by matching the reference image to the target image and if the role of the reference and the target are interchanged, a different DEM can be obtained. In this paper, we propose a new fusion technique to estimate the optimal DEM by eliminating the false DEM due to occlusion. To detect the false DEM, we utilize two measure of accuracy: self-consistency and cross-correlation score. We test the effectiveness of the proposed methods with a quantitative analysis using simulated images. Experimental result indicate that the proposed methods show 24.4% and 33.1% improvement over either DEM.

  • PDF

Integral Field Spectroscopic Data Reduction Method for High Resolution Infrared Observation

  • Lee, Sung-Ho;Pak, Soo-Jong;Choi, Min-Ho
    • Journal of Astronomy and Space Sciences
    • /
    • v.27 no.4
    • /
    • pp.309-318
    • /
    • 2010
  • We introduce a technical approach for reducing three-dimensional infrared (IR) spectroscopic data generated by integral field spectroscopy or slit-scanning observations. The first part of data reduction using IRAF presents a guideline for processing spectral images from long-slit IR spectroscopy. Multichannel image reconstruction, Image Analysis and Display (MIRIAD) is used in the later part to construct and analyze the data cubes which contain spatial and kinematic information of the objects. This technic has been applied to a sample data set of diffuse 2.1218 ${\mu}m$ $H_2$ 1-0 S(1) emission features observed by slit-scanning around Sgr A East in the Galactic center. Details of image processing for the high-dispersion infrared data are described to suggest a sequence of contamination cleaning and distortion correction. Practical solutions for handling data cubes are presented for survey observations with various configurations of slit positioning.

Mold Filling Analysis and Post-deformation Analysis of Injection-molded Aspheric Lenses for a Mobile Phone Camera Module (휴대폰 카메라용 비구면렌즈의 성형해석 및 후변형해석)

  • Park, Keun;Eom, Hyeju;Ahn, Jong-Ho
    • Design & Manufacturing
    • /
    • v.6 no.1
    • /
    • pp.12-17
    • /
    • 2012
  • In order to produce high-quality optical components, aspheric lenses have been widely applied in recent years. An aspheric lens consists of aspheric surfaces instead of spherical ones, which causes difficulty in the design process as well as the manufacturing procedure. Although injection molding is widely used to fabricate optical lenses owing to its high productivity, there remains lots of difficulty to determine appropriate mold design factors and injection molding parameters. In the injection molding fields, computer simulation has been effectively applied to analyze processes based on the shell analysis so far. Considering the geometry of optical lenses, a full-3d simulation based on solid elements has been reported as a reliable approach. The present work covers three-dimensional injection molding simulation and relevant deformation analysis of an injection molded plastic lens based on 3d solid elements. Numerical analyses have been applied to the injection molding processes of three aspheric lenses for an image sensing module of a mobile phone. The reliability of the proposed approach has been verified in comparison with the experimental results.

  • PDF

Kinematic Difference between the Lower Limb Joints and the Lower Extremities Given Elderly Women's Walking through the Lower-limb Resistance Exercises (하지 저항운동을 통한 여성고령자 보행 시 하지관절 및 분절의 운동학적 차이)

  • Seo, Se-Mi
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.12
    • /
    • pp.364-375
    • /
    • 2009
  • The purpose of this study is to offer basic data for the fall prevention by analyzing the kinematic difference between the lower limb joints and the lower extremities in elderly people's walking given the lower-limb resistance exercises. For this, three-dimensional image analysis was carried out by selecting 7 elderly women from over 70s to under 80 years old. To obtain the three-dimensional location coordinates in the lower limb joints and the lower extremities, it shot with 100Hz/s by using MCU(Qualisys, Sweden) camera. The shot image gained raw data on the location coordinates by using QTM(Qualisys, Sweden). As a result of calculating three-dimensional angle by using program of Matlab 6.5, the following conclusions were obtained. Flexion and extension in the thigh and the lower-leg extremities were indicated to be big in motion of flexion after exercising at E5. Foot segment indicated statistical difference while showing eversion at E4. Knee joints showed flexion at E4 after exercising. Ankle joints showed statistical difference while indicating motion in inversion at E3 and in eversion at E4(p<.05).