• 제목/요약/키워드: Three-dimensional facial images

검색결과 87건 처리시간 0.028초

Three-dimensional evaluation of the correlation between lip canting and craniofacial planes

  • Kim, Jun-Young;Park, Hee-Keun;Shin, Seung-Woo;Park, Jin Hoo;Jung, Hwi-Dong;Jung, Young-Soo
    • 대한치과교정학회지
    • /
    • 제50권4호
    • /
    • pp.258-267
    • /
    • 2020
  • Objective: This study aimed to analyze the correlation of horizontal and sagittal planes used in two-dimensional diagnosis with lip canting by using three-dimensional (3D) analysis. Methods: Fifty-two patients (25 men, 27 women; average age: 24 years) undergoing treatment for dentofacial deformity were enrolled. Computed tomography images were acquired, and digital imaging and communication in medicine files were reconstructed into a 3D virtual model wherein horizontal and sagittal craniofacial planes were measured. Subsequently, the correlations of lip canting with these horizontal and sagittal planes were investigated. Results: The mandibular symmetry plane, the occlusal plane, Camper's plane, the mandibular plane, Broadbent's plane, and the nasal axis plane were correlated with the amount of lip canting (Pearson's correlation coefficients: 0.761, 0.648, 0.556, 0.526, 0.438, and 0.406, respectively). Planes associated with the lower part of the face showed the strongest correlations; the strength of the correlations decreased in the midfacial and cranial regions. None of the planes showed statistically significant differences between patients with clinical lip canting (> 3°) and those without prominent lip canting. Conclusions: The findings of this study suggest that lip canting is strongly correlated with the mandibular symmetry plane, which includes menton deviation. This finding may have clinical implications with regard to the treatment of patients requiring correction of lip canting. Further studies are necessary for evaluating changes in lip canting after orthognathic surgery.

Three-dimensional intraoperative computed tomography imaging for zygomatic fracture repair

  • Peleg, Oren;Ianculovici, Clariel;Shuster, Amir;Mijiritsky, Eitan;Oz, Itay;Kleinman, Shlomi
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제47권5호
    • /
    • pp.382-387
    • /
    • 2021
  • Objectives: Zygomatic complex (ZMC) fractures comprise up to 40% of all facial fractures. Misaligned bone fragments and misplaced fixation hardware traditionally detected postoperatively on plain radiographs of the skull might require re-operation. The intraoperative O-Arm (Medtronic, USA) is a three-dimensional (3D) computed tomographic imaging system. Materials and Methods: This retrospective single-center study evaluated the utility of O-Arm scanning during corrective surgeries for ZMC and zygomatic arch (ZA) fractures from 2018 to 2020. Three females and 16 males (mean age, 31.52 years; range, 22-48 years) were included. Fracture instability (n=6) and facial deformity (n=15) were the most frequent indications for intraoperative 3D O-Arm scan. Results: The images demonstrated that all fracture lines were properly reduced and fixed. Another scan performed at the end of the fixation or reduction stage, however, revealed suboptimal results in five of the 19 cases, and further reduction and fixation of the fracture lines were required. Conclusion: Implementation of an intraoperative O-Arm system in ZMC and ZA fracture surgeries assists in obtaining predictable and accurate results and obviates the need for revision surgeries. The device should be considered for precise operations such as ZMC fracture repairs.

Accuracy of three-dimensional cephalograms generated using a biplanar imaging system

  • Park, Ha-Yeon;Lee, Jae-Seo;Cho, Jin-Hyoung;Hwang, Hyeon-Shik;Lee, Kyung-Min
    • 대한치과교정학회지
    • /
    • 제48권5호
    • /
    • pp.292-303
    • /
    • 2018
  • Objective: Biplanar imaging systems allow for simultaneous acquisition of lateral and frontal cephalograms. The purpose of this study was to compare measurements recorded on three-dimensional (3D) cephalograms constructed from two-dimensional conventional radiographs and biplanar radiographs generated using a new biplanar imaging system with those recorded on cone-beam computed tomography (CBCT)-generated cephalograms in order to evaluate the accuracy of the 3D cephalograms generated using the biplanar imaging system. Methods: Three sets of lateral and frontal radiographs of 15 human dry skulls with prominent facial asymmetry were obtained using conventional radiography, the biplanar imaging system, and CBCT. To minimize errors in the construction of 3D cephalograms, fiducial markers were attached to anatomical landmarks prior to the acquisition of radiographs. Using the 3D $Ceph^{TM}$ program, 3D cephalograms were constructed from the images obtained using the biplanar imaging system (3D $ceph_{biplanar}$), conventional radiography (3D $ceph_{conv}$), and CBCT (3D $ceph_{cbct}$). A total of 34 measurements were obtained compared among the three image sets using paired t-tests and Bland-Altman plotting. Results: There were no statistically significant differences between the 3D $ceph_{biplanar}$ and 3D $ceph_{cbct}$ measurements. In addition, with the exception of one measurement, there were no significant differences between the 3D $ceph_{cbct}$ and 3D $ceph_{conv}$ measurements. However, the values obtained from 3D $ceph_{conv}$ showed larger deviations than those obtained from 3D $ceph_{biplanar}$. Conclusions: The results of this study suggest that the new biplanar imaging system enables the construction of accurate 3D cephalograms and could be a useful alternative to conventional radiography.

Three-dimensional cone-beam computed tomography based comparison of condylar position and morphology according to the vertical skeletal pattern

  • Park, In-Young;Kim, Ji-Hyun;Park, Yang-Ho
    • 대한치과교정학회지
    • /
    • 제45권2호
    • /
    • pp.66-73
    • /
    • 2015
  • Objective: To compare condylar position and morphology among different vertical skeletal patterns. Methods: Diagnostic cone-beam computed tomography images of 60 adult patients (120 temporomandibular joints) who visited the orthodontic clinic of Hallym University Sacred Heart Hospital were reviewed. The subjects were divided into three equal groups according to the mandibular plane angle: hypodivergent, normodivergent, and hyperdivergent groups. Morphology of the condyle and mandibular fossa and condylar position were compared among the groups. Results: The hypodivergent and hyperdivergent groups showed significant differences in superior joint spaces, antero-posterior condyle width, medio-lateral condyle width, condyle head angle, and condylar shapes. Conclusions: Condylar position and morphology vary according to vertical facial morphology. This relationship should be considered for predicting and establishing a proper treatment plan for temporomandibular diseases during orthodontic treatment.

얼굴의 3차원 위치 및 움직임 추정에 의한 시선 위치 추적 (Facial Gaze Detection by Estimating Three Dimensional Positional Movements)

  • 박강령;김재희
    • 대한전자공학회논문지SP
    • /
    • 제39권3호
    • /
    • pp.23-35
    • /
    • 2002
  • 시선 위치 추적이란 모니터상에 사용자가 쳐다보고 있는 지점을 파악해 내는 기술이다 이 논문에서는 컴퓨터 비젼 방법을 이용하여 사용자가 모니터 상에 어느 지점을 쳐다보고 있는지를 파악(시선 위치 추적)하는 새로운 방법을 제안한다. 시선위치를 파악하기 위해 본 논문에서는 얼굴 영역 및 얼굴 특징점(양 눈, 양 콧구멍, 입술 끝점 등)을 2차원 카메라 영상으로부터 추출하였으며, 이들의 움직임으로부터 카메라 보정 및 매개변수 추정 방법등을 이용하여 초기 3차원 위치를 추정해 내었다. 이후 모니터 상의 한 지점을 쳐다보기 위해 사용자가 얼굴을 움직이는 경우 이러한 얼굴의 3차원 움직임 량 역시 자동으로 추정하였다. 이로부터 변화된 얼굴 특징점의 3차원 위치를 계산해 낼 수 있었으며, 이를 바탕으로 모니터 상의 시선 위치를 구하였다. 실험 결과, 19인치 모니터상의 임의의 지점을 사용자가 쳐다보았을 때, 약 2.01인치의 시선 위치에러 성능을 얻었다.

Comparison of three midsagittal planes for three-dimensional cone beam computed tomography head reorientation

  • Lee, Eon-Hwa;Yu, Hyung-Seog;Lee, Kee-Joon;Han, Sang-Sun;Jung, Hwi-Dong;Hwang, Chung-Ju
    • 대한치과교정학회지
    • /
    • 제50권1호
    • /
    • pp.3-12
    • /
    • 2020
  • Objective: This study compared three prominent midsagittal planes (MSPs) to identify the MSP that best approximates the true symmetrical MSP. Methods: Forty-three patients (mean age, 23.0 ± 8.20 years) were grouped as follows: group 1 consisted of 10 patients with skeletal Class I and a menton (Me) deviation of < 2 mm; group 2, 11 patients with skeletal Class III and a Me deviation < 2 mm; group 3, nine patients with skeletal Class III and a Me deviation of 2 to less than 4 mm; and group 4, 13 patients with skeletal Class III and an Me deviation ≥ 4 mm. The candidate MSPs were established by three-dimensional (3D) cone beam computed tomography (CBCT) reorientation methods (RMs): (1) the MSP perpendicular to the Frankfort horizontal (FH) plane while passing through the crista galli and basion; (2) the MSP including the nasion, incisive foramen, and basion; (3) the MSP including the nasion, anterior nasal spine, and posterior nasal spine. The mean absolute distances (MADs) to the MSPs were calculated from the coordinates of 1,548 points on 129 CBCT images. The differences in the values of the 3D coordinates among RMs were compared. Results: The MADs of the three RMs showed significant differences (p < 0.05). Most of the differences in values of the coordinates were not significant among RMs. Conclusions: Although the differences in distance among the three MSPs were minor, the MSP perpendicular to the FH plane while passing through the crista galli and basion best approximated the true symmetrical MSP.

Changes in the hyoid bone, tongue, and oropharyngeal airway space after mandibular setback surgery evaluated by cone-beam computed tomography

  • Kim, Seon-Hye;Choi, Sung-Kwon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제42권
    • /
    • pp.27.1-27.9
    • /
    • 2020
  • Background: Mandibular setback surgery can change the position of the mandible which improves occlusion and facial profile. Surgical movement of the mandible affects the base of the tongue, hyoid bone, and associated tissues, resulting in changes in the pharyngeal airway space. The aim of this study was to analyze the 3-dimensional (3D) changes in the hyoid bone and tongue positions and oropharyngeal airway space after mandibular setback surgery. Methods: A total of 30 pairs of cone-beam computed tomography (CBCT) images taken before and 1 month after surgery were analyzed by measuring changes in the hyoid bone and tongue positions and oropharyngeal airway space. The CBCT images were reoriented using InVivo 5.3 software (Anatomage, San Jose, USA) and landmarks were assigned to establish coordinates in a three-dimensional plane. The mean age of the patients was 21.7 years and the mean amount of mandibular setback was 5.94 mm measured from the B-point. Results: The hyoid bone showed significant posterior and inferior displacement (P < 0.001, P < 0.001, respectively). Significant superior and posterior movements of the tongue were observed (P < 0.05, P < 0.05, respectively). Regarding the velopharyngeal and glossopharyngeal spaces, there were significant reductions in the volume and minimal cross-sectional area (P < 0.001). The anteroposterior and transverse widths of the minimal cross-sectional area were decreased (P < 0.001, P < 0.001, respectively). In addition, the amount of mandibular setback positively correlated with the amount of posterior and inferior movement of the hyoid bone (P < 0.05, P < 0.05, respectively). Conclusion: There were significant changes in the hyoid bone, tongue, and airway space after mandibular setback surgery.

3.0T 자기공명영상기기에서 시행한 3D-FLAIR 영상에서의 정상 안면신경의 조영증강 양상 (Enhancement Pattern of the Normal Facial Nerve on Three - Dimensional (3D) - Fluid Attenuated Inversion Recovery (FLAIR) Sequence at 3.0 T MR Units)

  • 현동호;임현경;박지원;김종림;이하영;박순찬;안중호;백정환;최충곤;이정현
    • Investigative Magnetic Resonance Imaging
    • /
    • 제16권1호
    • /
    • pp.25-30
    • /
    • 2012
  • 목적: 3-T 자기공명영상장치에서 시행한 3D-FLAIR 및 3D-T1-FFE-FS영상에서의 정상안면신경의 조영증강 양상의 비교가 그 목적이다. 대상과 방법: 측두골 자기공명영상을 촬영한 환자 중 안면신경이상의 과거력이 없는 20명의 환자를 대상으로 하였다. 두 명의 영상의학전문의가 정상안면신경의 조영증강을 평가하기 위해 조영증강 전후의 3D-T1-FFE-FS영상과 3D-FLAIR영상을 2주 간격으로 독립적으로 분석하였다. 안면신경은 5개의 분절로 나누었고 조영증강의 정도는 없거나 약하게 혹은 강하게 되는 경우로 나누어 분석하였다. 결과: 3D-FLAIR영상에서 한 명의 평가자가 두 예의 안면신경 슬부에 약한 조영증강이 있다고 보았다. 3D-T1-FFE-FS영상에서는 13예의 안면신경에서 최소 한 분절 이상 조영증강이 있다고 하였고, 최소 한 명의 평가자가 안면신경의 총 100개 분절 중 17개의 분절에서 조영증강이 있다고 분석하였으며, 유양분절의 빈도가 가장 높았다. 3D-T1-FFE-FS영상에서 정상안면신경의 조영증강에 대한 평가자간의 일치도는 ${\kappa}$값 0.589로 우수하였다. 결론: 3D-T1-FFE-FS영상과 달리 3D-FLAIR영상에서 정상안면신경은 거의 조영증강되지 않는다.

삼차원 전산화 단층촬영술을 이용한 안모 비대칭환자의 골격 분석 (SKELETAL PATTERN ANALYSIS OF FACIAL ASYMMETRY PATIENT USING THREE DIMENSIONAL COMPUTED TOMOGRAPHY)

  • 최정구;민승기;오승환;권경환;최문기;이준;오세리;유대현
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제34권6호
    • /
    • pp.622-627
    • /
    • 2008
  • In orthognathic surgery, precise analysis and diagnosis are essential for successful results. In facial asymmetric patient, traditional 2D image analysis has been used by lateral and P-A Cephalometric view, Skull PA, Panorama, Submentovertex view etc. But clinicians sometimes misdiagnose because they cannot find exact landmark due to superimposition, moreover image can be magnified and distorted by projection technique or patient's skull position, when using these analysis and method. For overcome these defects, analysis by using of 3D CT has been introduced. In this way we can analysis precisely by getting the exact image free of artifact and finding exact landmark with no interruption of superimposition. So we want to review of relationship between various skeletal landmarks of mandible or cranial base and facial asymmetry by predictable analysis using 3D CT. We select the cases of the patients who visited our department for correction of facial asymmetry during 2003-2007 and who were taken image of 3D CT for diagnosis. 3D CT images were reconstructed to 3D image by using V-Work program (Cybermed Inc., Seoul, Korea). And we analysis the relationship between facial asymmetry and various affecting factor of skeletal pattern. The mandibular ramus hight difference between right and left was most affecting factor that express facial asymmetry. And in this research, there was no relationship between cranial base and facial asymmetry. The angulation between facial midline and mandibular ramus divergency has significant relationship with facial asymmetry

Comparison of the condyle-fossa relationship between skeletal class III malocclusion patients with and without asymmetry: a retrospective three-dimensional cone-beam computed tomograpy study

  • Kim, Hyoun Oak;Lee, Won;Kook, Yoon-Ah;Kim, Yoonji
    • 대한치과교정학회지
    • /
    • 제43권5호
    • /
    • pp.209-217
    • /
    • 2013
  • Objective: This study investigated whether temporomandibular joint (TMJ) condyle-fossa relationships are bilaterally symmetric in class III malocclusion patients with and without asymmetry and compared to those with normal occlusion. The hypothesis was a difference in condyle-fossa relationships exists in asymmetric patients. Methods: Group 1 comprised 40 Korean normal occlusion subjects. Groups 2 and 3 comprised patients diagnosed with skeletal class III malocclusion, who were grouped according to the presence of mandibular asymmetry: Group 2 included symmetric mandibles, while group 3 included asymmetric mandibles. Pretreatment three-dimensional cone-beam computed tomography (3D CBCT) images were obtained. Right- and left-sided TMJ spaces in groups 1 and 2 or deviated and non-deviated sides in group 3 were evaluated, and the axial condylar angle was compared. Results: The TMJ spaces demonstrated no significant bilateral differences in any group. Only group 3 had slightly narrower superior spaces (p < 0.001). The axial condylar angles between group 1 and 2 were not significant. However, group 3 showed a statistically significant bilateral difference (p < 0.001); toward the deviated side, the axial condylar angle was steeper. Conclusions: Even in the asymmetric group, the TMJ spaces were similar between deviated and non-deviated sides, indicating a bilateral condyle-fossa relationship in patients with asymmetry that may be as symmetrical as that in patients with symmetry. However, the axial condylar angle had bilateral differences only in asymmetric groups. The mean TMJ space value and the bilateral difference may be used for evaluating condyle-fossa relationships with CBCT.