• 제목/요약/키워드: Three-dimensional computed tomographic angiography

검색결과 9건 처리시간 0.02초

Extravasation from the Distal Anterior Choroidal Artery Aneurysm in Moyamoya Patient during Computed Tomographic Angiography

  • Chong, Jong-Yun;Yi, Hyeong-Joong;Kim, Kwang-Myung;Lee, Seung-Ro
    • Journal of Korean Neurosurgical Society
    • /
    • 제41권5호
    • /
    • pp.340-342
    • /
    • 2007
  • Three-dimensional computed tomographic angiography [CTA], a representative noninvasive radiologic technique, is being widely used for detecting vascular lesions in specific intracranial bleeding under a certain circumstance [acute nontraumatic subarachnoid hemorrhage]. We encountered a case of extravasation of the contrast medium on CTA images that appeared as ribbon-like high-attenuation lesion from an aneurysm at the distal anterior choroidal artery in a young adult moyamoya patient. As CTA is used more frequently, it is imperative to understand such unusual but, potentially lethal image findings to conduct a prompt intervention.

Usefulness of sectional images in dural AVF for the interpretation of venous anatomy

  • Myongjin Kang;Sanghyeon Kim
    • Journal of Cerebrovascular and Endovascular Neurosurgery
    • /
    • 제26권2호
    • /
    • pp.119-129
    • /
    • 2024
  • Knowledge of the venous anatomy is essential for appropriately treating dural arteriovenous fistulas (AVFs). It is challenging to determine the overall venous structure despite performing selective angiography for dural AVFs with feeder from multiple selected arteries. This is because only a part of the veins can be observed through the shunt in the selected artery. Therefore, after performing selective angiography of all vessels to understand the approximate venous anatomy, the venous anatomy can be easily understood by closely examining the source image of computed tomographic angiography or magnetic resonance angiography. Through this, it is possible to specify the vein that is to be blocked (target embolization), thereby avoiding extensive blocking of the vein and avoiding various complications. In the case of dural AVF with feeder from single selected artery, if the multiplanar reconstruction image of the three-dimensional rotational computed tomography obtained by performing angiography is analyzed thoroughly, a shunted pouch can be identified. If embolization is performed by targeting this area, unnecessary sinus total packing can be avoided.

자발성 뇌지주막하 출혈 환자에서 뇌동맥류 검출에 대한 고식적 혈관조영술과 3차원 전산화 단층 혈관조영술의 비교 (Detection of Aneurysms in Patients with Spontaneous Subarachnoid Hemorrhage : A Comparison of Three-dimensional Computed Tomographic Angiography and Conventional Angiography)

  • 이경수;강창구;허륭;이상훈;정의화
    • Journal of Korean Neurosurgical Society
    • /
    • 제30권6호
    • /
    • pp.711-716
    • /
    • 2001
  • Objectives : Three-dimensional computed tomographic angiography(3D-CTA) is recently developed diagnostic imaging modality. We have studied this noninvasive method for possible role in replacing conventional angiography( CA) in the detection of aneurysms of the circle of Willis in patients with subarachnoid hemorrahge(SAH). Methods : We studied retrospectively, the 100 patients with SAH or unruptured aneurysms admitted to our hospital from October 1997 to December 1998. Among there, 85 patients underwent CTA, 82 patients underwent CA and 67 patients underwent both of CTA and CA. 3D-CTA was obtained using maximum intensity projection(MIP) and shaded-surface display(SSD) reconstruction. Results : Total 107 aneurysms were detected in 92 patients, and 64 aneurysms were detected in 67 patients underwent both CTA and CA. In five cases of those 67 cases, aneurysms were detected by CA but not by 3D-CTA. The detection rate of aneurysms(91.8%) and the detection rate of parent artery in cases of anterior communicating artery aneurysms(86.9%) with total 3D-CTA were relatively compatible with that of CA. But 3D-CTA was not enough in detection of posterior communicating artery aneurysms, internal carotid artery aneurysms as well as small sized aneurysm(<3mm). Conclusion : We consider CTA is valuable in as a screening test for cerebral aneurysm and follow-up test. And it is also valuable in early surgery for patients with aneurysmal rebleeding because of simple, quick, non-invasive method.

  • PDF

Determination of Aneurysmal Location with 3 Dimension-Computed Tomographic Angiography in the Microsurgery of Paraclinoid Aneurysms

  • Kim, Min-Young;Chung, Seung-Young;Kim, Seung-Min;Park, Moon-Sun;Jung, Sung-Sam
    • Journal of Korean Neurosurgical Society
    • /
    • 제42권1호
    • /
    • pp.35-41
    • /
    • 2007
  • Objective : Determining the location of paraclinoid aneurysms for microsurgery is important for selecting treatment options, especially when deciding on the release of the dural ring in direct clipping. We examined the reliability of using the optic strut as an anatomical landmark for evaluating the location of paraclinoid aneurysms. Methods : Cadaveric dissection was performed to establish the relationship of the optic strut to the dural ring. Results from these anatomic studies were compared with the three-demensional computed tomographic angiographic [3D-CTA] findings of nine patients with ten paraclinoid aneurysms between May 2004 and October 2005. These, 3D-CTA results were then compared with intraoperative findings. Results : The inferior boundary of the optic strut accurately localized the point at the proximal dural ring in cadaveric study. The optic strut and its relationship to the aneurysms was well observed on the multiplanar reformats of 3D-CTA. During microsurgery, nine of ten aneurysms were verified to arise from distal to the upper surface of the optic strut. Two aneurysms that had arisen between the inferior and superior boundary of the optic strut were observed to lie within the carotid cave. One aneurysm which had arisen at the inferior boundary of the optic strut and directed inferiorly was observed to lie within the cavernous sinus just after the release of the proximal ring. Conclusion : The optic strut, as identified with multiplanar reformats of 3D-CTA, provided a reliable anatomic landmark for the proximal rings and an important information about the location of aneurysms around the anterior clinoid process (ACP). Therefore, 3D-CTA and the optic strut could become an invaluable tool and a landmark in the assessment of the location of paraclinoid aneurysms for microsurgery.

The Usefulness of 3D-CT Angiography as a Screening Tool for Vascular Abnormalities in Spontaneous ICH Patients

  • Lee, Ho-Jin;Kong, Min-Ho;Hong, Hyun-Jong;Kang, Dong-Soo;Song, Kwan-Young
    • Journal of Korean Neurosurgical Society
    • /
    • 제41권4호
    • /
    • pp.230-235
    • /
    • 2007
  • Objective : We investigated the incidence of the vascular abnormalities associated with spontaneous intracerebral hemorrhage [ICH] using three-dimensional computed tomographic angiography [3D-CTA]. Methods : We prospectively assessed consecutive 76 patients with spontaneous intracerebral hemorrhage [ICH] who underwent 3D-CTA between June 2003 and May 2005. The patients with a recent history of trauma or mainly subarachnoid hemorrhage were excluded. We investigated relationship between vascular abnormality and ICH location. The findings of 3D-CTA were classified as one of three patterns with ICH; type A [without evidence of vascular abnormality], type B [with no vascular abnormality as the source of hemorrhage, but with incidental vascular abnormality], and type C [presence of a vascular abnormality as the source of hemorrhage]. Results : Sites of ICH were lobar 26, basal ganglia 23, thalamus 17, posterior fossa 6 and dominant intraventricular hemorrhage [IVH] 4. Among 76 patients, sixteen [21.1%] vascular abnormalities were noted excluding 13 cases of stenoocclusive disease. Sixteen cases included 6 cases of cerebral aneurysms [7.9%], 5 moyamoya diseases [6.6%], 4 arteriovenous malformations [5.3%] and 1 dural sinus thrombosis [1.3%]. Lobar ICH [30.8%] had a higher vascular abnormalities than other types, and younger age [<40] group had a higher incidence of vascular abnormalities than old age group. The patterns of 3D-CTA include sixty cases [79.0%] of type A, 6 cases [7.8%] of type Band 10 cases [13.2%] of type C. The vascular abnormalities were found in 8 [13.5%] of 59 hypertensive patients and 8 [47.0%] of 17 non-hypertensive patients [p=0.006]. Conclusion : 3D-CT angiography is considered a useful screening tool for ICH patients with suspected cerebrovascular abnormalities and should be considered in such clinical settings, especially in lobar type and in non-hypertensive younger patients.

Computed tomographic anatomy of hepatic artery in normal beagle dogs

  • Kim, Soochan;Jeong, Seongmok;Lee, Heechun;Lee, Youngwon;Choi, Hojung
    • 대한수의학회지
    • /
    • 제59권2호
    • /
    • pp.55-58
    • /
    • 2019
  • This study was performed to examine the visualization and anatomical variants of the hepatic artery with dual-phase computed tomography (CT) angiography and three-dimensional volume rendering imaging analysis in clinically normal dogs. Seven healthy beagle dogs were enrolled and underwent dual CT angiography. Arterial phase images could be obtained with multi-detector CT angiography using the fixed-scan method in these dogs. Contrast enhancement of the hepatic parenchyma was quite minimal because of the unique blood supply system of the liver. In most dogs, the main hepatic arterial branches were the right lateral branch, left branch, and right medial branch. Although hepatic arterial variation appears to be common in dogs, only one dog in this study had the caudate lobar branch as the first branch of the hepatic artery. Further study on a larger number of dogs with CT images will be needed to identify and classify the pattern of hepatic arterial variations.

Diverse imaging characteristics of a mandibular intraosseous vascular lesion

  • Handa, Hina;Naidu, Giridhar S.;Dara, Balaji Gandhi Babu;Deshpande, Ashwini;Raghavendra, Raju
    • Imaging Science in Dentistry
    • /
    • 제44권1호
    • /
    • pp.67-73
    • /
    • 2014
  • Intraosseous vascular lesions of the maxillofacial region are rare, and the differential diagnosis of intraosseous vascular malformations from other jaw lesions can be challenging. In the present case, magnetic resonance imaging and three-dimensional computed tomographic angiography (CTA) was used for diagnosis, and the lesion was treated wih surgical excision. Diverse characteristics such as the "honeycomb" and "sunburst" radiographic appearances and the absence of major peripheral feeder vessels in the CTA were noted. Intraosseous vascular malformations have a varied radiographic appearance, and the nomenclature of these lesions is equally diverse, with several overlapping terms. Pathologists do not generally differentiate among intraosseous vascular lesions on the basis of histopathology, although these lesions may present with contrasting immunohistochemical and clinical behaviors requiring varied treatment strategies. This case report highlights the need for multiple imaging modalities to differentiate among vascular lesions, as well as to better understand the behaviors of these unique lesions.

Utility of Multidetector Computed Tomographic Angiography as an Alternative to Transesophageal Echocardiogram for Preoperative Transcatheter Mitral Valve Repair Planning

  • Craig Basman;Caroline Ong;Tikal Kansara;Zain Kassam;Caleb Wutawunashe;Jennifer Conroy;Arber Kodra;Biana Trost;Priti Mehla;Luigi Pirelli;Jacob Scheinerman;Varinder P Singh;Chad A Kliger
    • Journal of Cardiovascular Imaging
    • /
    • 제31권1호
    • /
    • pp.18-23
    • /
    • 2023
  • BACKGROUND: Three-dimensional (3D) transesophageal echocardiogram (TEE) is the gold standard for the diagnosis of degenerative mitral regurgitation (dMR) and preoperative planning for transcatheter mitral valve repair (TMVr). TEE is an invasive modality requiring anesthesia and esophageal intubation. The severe acute respiratory syndrome coronavirus 2 pandemic has limited the number of elective invasive procedures. Multi-detector computed tomographic angiography (MDCT) provides high-resolution images and 3D reconstructions to assess complex mitral anatomy. We hypothesized that MDCT would reveal similar information to TEE relevant to TMVr, thus deferring the need for a preoperative TEE in certain situations like during a pandemic. METHODS: We retrospectively analyzed data on patients who underwent or were evaluated for TMVr for dMR with preoperative MDCT and TEE between 2017 and 2019. Two TEE and 2 MDCT readers, blinded to patient outcome, analyzed: leaflet pathology (flail, degenerative, mixed), leaflet location, mitral valve area (MVA), flail width/gap, anterior-posterior (AP) and commissural diameters, posterior leaflet length, leaflet thickness, presence of mitral valve cleft and degree of mitral annular calcification (MAC). RESULTS: A total of 22 (out of 87) patients had preoperative MDCT. MDCT correctly identified the leaflet pathology in 77% (17/22), flail leaflet in 91% (10/11), MAC degree in 91% (10/11) and the dysfunctional leaflet location in 95% (21/22) of patients. There were no differences in the measurements for MVA, flail width, commissural or AP diameter, posterior leaflet length, and leaflet thickness. MDCT overestimated the measurements of flail gap. CONCLUSIONS: For preoperative TMVr planning, MDCT provided similar measurements to TEE in our study.

심장 CT 혈관 조영 영상에서 대동맥 및 심문 자동 검출 (Automatic Extraction of Ascending Aorta and Ostium in Cardiac CT Angiography Images)

  • 김혜련;강미선;김명희
    • 한국컴퓨터그래픽스학회논문지
    • /
    • 제23권1호
    • /
    • pp.49-55
    • /
    • 2017
  • 심장 CT 혈관 조영 영상은 심혈관의 전체 해부학 구조를 3D 로 보여줄 뿐 아니라 병변의 정보를 제공하기 때문에 관상동맥 질환 진단 및 치료에 많이 사용되고 있다. 하지만 영상의 방대한 크기로 인해 수동으로 정보를 추출하는 데는 한계가 있어 자동으로 심혈관을 정확하게 추출하는 연구들이 활발히 진행되고 있다. 심혈관 자동 추출 알고리즘을 개발하는데 있어 심혈관의 시작점인 상행대동맥의 심문을 검출하는 방법은 필수적인 부분이다. 본 논문에서는 심혈관의 시작점인 심문을 분할하는 방법을 제안한다. 첫째, 상행대동맥의 크기와 위치를 고려한 허프변환으로 대동맥 초기영역을 검출한다. 둘째, 초기영역을 기반으로 탐색범위를 줄일 수 있도록 관심 볼륨 영역을 설정한다. 셋째, 지오데식 활성외곽선 모델을 기반으로 정제된 대동맥 영역을 검출한다. 마지막으로 검출된 대동맥 영역에서 심문을 분할한다. 제안방법의 평가를 위해 20 개의 심장 CT 혈관 조영 영상에서 전문가가 수동으로 표기한 시작점과 비교 분석하였다. 실험 결과 제안방법을 통해 시작점이 제대로 추출 됨을 확인할 수 있었다.