• Title/Summary/Keyword: Three-dimensional angiography

Search Result 67, Processing Time 0.025 seconds

Optimal Cardiac Magnetic Resonance Contrast-Enhanced Timing Robust Angiography (CMR-CENTRA) for the Three-Dimensional Reconstruction of the Bilateral Atria in the Electroanatomic Mapping (EAM) of Atrial Fibrillation

  • Kim, Jun Seong;Oh, Yu-Whan;Shim, Jaemin;Kim, Young-Hoon;Hwang, Sung Ho
    • Investigative Magnetic Resonance Imaging
    • /
    • v.21 no.3
    • /
    • pp.131-138
    • /
    • 2017
  • Purpose: To optimize the timing of scans using cardiac magnetic resonance contrast-enhanced timing robust angiography (CMR-CENTRA) for electroanatomic mapping (EAM) of the right atrium (RA) and left atrium (LA) in patients with atrial fibrillation (AF). Materials and Methods: Fifty patients with AF (38 men; mean age, $59.6{\pm}9.3years$) underwent CMR-CENTRA in preparation for EAM. The CMR-CENTRA data were acquired at five different scan times: 0 seconds, 5 seconds, 10 seconds, 15 seconds, and 20 seconds after an intravenous injection of contrast media. To evaluate the degree of contrast enhancement, right atrial relative contrast (RA-RC) and left atrial relative contrast (LA-RC) on the CMR-CENTRA scans were assessed at each time point. The three-dimensional (3D) reconstruction of the RA and LA for the EAM system was performed using the CMR-CENTRA data. Results: A CMR-CENTRA at a scan time of 10 seconds showed significantly greater LA-RC (P < 0.05) compared with all other scan times. A CMR-CENTRA at a scan time of 15 seconds showed significantly greater RA-RC (P < 0.05) compared with all other scan times. In the 3D reconstruction of the RA, the success rates of CMR-CENTRA at scan times of 10 seconds and 15 seconds were 18% and 100%, respectively. In the 3D reconstruction of the LA, the success rates of CMR-CENTRA at 10- and 15-second scan times were 100%. Conclusion: The CMR-CENTRA data acquired at 15 seconds after the injection of contrast media is appropriate for the preparation of an EAM system that is focused on the RA and LA in patients with AF.

Diverse imaging characteristics of a mandibular intraosseous vascular lesion

  • Handa, Hina;Naidu, Giridhar S.;Dara, Balaji Gandhi Babu;Deshpande, Ashwini;Raghavendra, Raju
    • Imaging Science in Dentistry
    • /
    • v.44 no.1
    • /
    • pp.67-73
    • /
    • 2014
  • Intraosseous vascular lesions of the maxillofacial region are rare, and the differential diagnosis of intraosseous vascular malformations from other jaw lesions can be challenging. In the present case, magnetic resonance imaging and three-dimensional computed tomographic angiography (CTA) was used for diagnosis, and the lesion was treated wih surgical excision. Diverse characteristics such as the "honeycomb" and "sunburst" radiographic appearances and the absence of major peripheral feeder vessels in the CTA were noted. Intraosseous vascular malformations have a varied radiographic appearance, and the nomenclature of these lesions is equally diverse, with several overlapping terms. Pathologists do not generally differentiate among intraosseous vascular lesions on the basis of histopathology, although these lesions may present with contrasting immunohistochemical and clinical behaviors requiring varied treatment strategies. This case report highlights the need for multiple imaging modalities to differentiate among vascular lesions, as well as to better understand the behaviors of these unique lesions.

Diagnostic Imaging of Portosystemic Shunt using CT in Two Dogs (전산화단층촬영을 이용한 문맥전신단락의 진단 증례)

  • Jung, Joo-Hyun;Chae, Woong-Joo;Chang, Jin-Hwa;Chae, Ho-Cheol;Kim, Wan-Hee;Lee, Ki-Chang;Yoon, Jung-Hee;Choi, Min-Cheol
    • Journal of Veterinary Clinics
    • /
    • v.24 no.3
    • /
    • pp.461-466
    • /
    • 2007
  • Two dogs were admitted with a history of anorexia, ataxia, shivering, lethargy, hypersalivation and seizure. Patients were suspected for portosystemic shunts on the basis of clinical signs, increased hepatic serum profiles on the blood test, microhepatica on plain abdominal radiographs, and an abnormally dilated and tortuous vessel on abdominal ultrasonographs. To diagnose PSS and to further evaluate type, shape, and location of shunt and hepatic vasculatures, the computed tomography (CT) angiography for portal and systemic circulation was performed. The shape, location and pathway of extrahepatic single shunt were confirmed in two dogs. Dual phases (the arterial phase and the venous phase) CT angiography and reformatted and three-dimensional images offered good understanding of PSS and planning surgical treatment.

MR Imaging of Congenital Heart Diseases in Adolescents and Adults

  • Yeon Hyeon Choe;I-Seok Kang;Seung Woo Park;Heung Jae Lee
    • Korean Journal of Radiology
    • /
    • v.2 no.3
    • /
    • pp.121-131
    • /
    • 2001
  • Echocardiography and catheterization angiography suffer certain limitations in the evaluation of congenital heart diseases in adults, though these are overcome by MRI, in which a wide field-of view, unlimited multiplanar imaging capability and three-dimensional contrast-enhanced MR angiography techniques are used. In adults, recently introduced fast imaging techniques provide cardiac MR images of sufficient quality and with less artifacts. Ventricular volume, ejection fraction, and vascular flow measurements, including pressure gradients and pulmonary-to-systemic flow ratio, can be calculated or obtained using fast cine MRI, phase-contrast MR flow-velocity mapping, and semiautomatic analysis software. MRI is superior to echocardiography in diagnosing partial anomalous pulmonary venous connection, unroofed coronary sinus, anomalies of the pulmonary arteries, aorta and systemic veins, complex heart diseases, and postsurgical sequelae. Biventricular function is reliably evaluated with cine MRI after repair of tetralogy of Fallot, and Senning's and Mustard's operations. MRI has an important and growing role in the morphologic and functional assessment of congenital heart diseases in adolescents and adults.

  • PDF

Low-Dose Three-Dimensional Rotational Angiography for Evaluating Intracranial Aneurysms: Analysis of Image Quality and Radiation Dose

  • Hee Jong Ki;Bum-soo Kim;Jun-Ki Kim;Jai Ho Choi;Yong Sam Shin;Yangsean Choi;Na-Young Shin;Jinhee Jang;Kook-jin Ahn
    • Korean Journal of Radiology
    • /
    • v.23 no.2
    • /
    • pp.256-263
    • /
    • 2022
  • Objective: This study aimed to evaluate the image quality and dose reduction of low-dose three-dimensional (3D) rotational angiography (RA) for evaluating intracranial aneurysms. Materials and Methods: We retrospectively evaluated the clinical data and 3D RA datasets obtained from 146 prospectively registered patients (male:female, 46:100; median age, 58 years; range, 19-81 years). The subjective image quality of 79 examinations obtained from a conventional method and 67 examinations obtained from a low-dose (5-seconds and 0.10-μGy/frame) method was assessed by two neurointerventionists using a 3-point scale for four evaluation criteria. The total image quality score was then obtained as the average of the four scores. The image quality scores were compared between the two methods using a noninferiority statistical testing, with a margin of -0.2 (i.e., score of low-dose group - score of conventional group). For the evaluation of dose reduction, dose-area product (DAP) and air kerma (AK) were analyzed and compared between the two groups. Results: The mean total image quality score ± standard deviation of the 3D RA was 2.97 ± 0.17 by reader 1 and 2.95 ± 0.20 by reader 2 for conventional group and 2.92 ± 0.30 and 2.95 ± 0.22, respectively, for low-dose group. The image quality of the 3D RA in the low-dose group was not inferior to that of the conventional group according to the total image quality score as well as individual scores for the four criteria in both readers. The mean DAP and AK per rotation were 5.87 Gy-cm2 and 0.56 Gy, respectively, in the conventional group, and 1.32 Gy-cm2 (p < 0.001) and 0.17 Gy (p < 0.001), respectively, in the low-dose group. Conclusion: Low-dose 3D RA was not inferior in image quality and reduced the radiation dose by 70%-77% compared to the conventional 3D RA in evaluating intracranial aneurysms.

Is Computerized Tomography Angiographic Surveillance Valuable for Prevention of Tracheoinnominate Artery Fistula, a Life-Threatening Complication after Tracheostomy?

  • Sung, Jae-Hoon;Kim, Il-Sup;Yang, Seung-Ho;Hong, Jae-Taek;Son, Byung-Chul;Lee, Sang-Won
    • Journal of Korean Neurosurgical Society
    • /
    • v.49 no.2
    • /
    • pp.107-111
    • /
    • 2011
  • Objective : The aim of this study was to evaluate the utility of volume-rendered helical computerized tomography (CT) angiography focusing tracheostomy tube and innominate artery for prevention of tracheoinnominate artery fistula. Methods : The authors retrospectively analyzed 22 patients with tracheostomy who had checked CT angiography. To evaluate the relationship between tracheostomy tube and innominate artery, we divided into three categories. First proximal tube position based on cervical vertebra, named "tracheostomy tube departure level (TTDL)". Second, distal tube position and course of innominate artery, named "tracheostomy tube-innominate artery configuration (TTIC)". Third, the gap between the tube and innominate artery, named "tracheostomy tube to innominate artery gap (TTIG)". The TTDL/TTIC and TTIG are based on 3-dimensional (3D) reconstruction around tracheostomy and enhanced axial slices of upper chest, respectively. Results : First, mean TTDL was $6.8{\pm}0.6$. Five cases (23%) were lower than C7 vertebra. Second, TTIC were remote to innominate artery (2 cases; 9.1 %), matched with it (14 cases; 63.6%) or crossed it (6 cases; 27.3%). Only 9% of cases were definitely free from innominate artery injury. Third, average TTIG was $4.3{\pm}4.6$ mm. Surprisingly, in 6 cases (27.3%), innominate artery, trachea wall and tracheostomy tube were tightly attached all together, thus have much higher probability of erosion. Conclusion : If low TTDL, match or crossing type TTIC with reverse-L shaped innominate artery, small trachea and thin TTIG are accompanied all together, we may seriously consider early plugging and tube removal.

Usefulness of Three-Dimensional CT Image in Meningioma Using Contrast Method (조영법을 이용한 뇌수막종에서 3차원 CT영상의 유용성)

  • Lee, Jun-Haeng;Baek, Sung-Eun;Lee, Sang-Bock;Kim, Yong-Wan
    • Journal of the Korean Society of Radiology
    • /
    • v.2 no.1
    • /
    • pp.17-21
    • /
    • 2008
  • Because of the reason that the meningioma is enhanced lately, we started the study to maximally enhance the meningioma. we were to know the relation between meningioma and vessels in the skull and compared 3D CT angiography with the conventional angiography. we got the data from 6 patients performed by both 3D CT angiography and there were 5 cases in sphenoidal ridge and 1 case parasagittal sinus. Injecting the contrast media at 3 ml/sec, 120 ml and then the CT number reached 100, we started the study using the medical system Program(smart prep). The scan parameters were HS-Mode(1.25 mm / 7.5 mm) right after being injected all and reconstructed with 0.5 mm interval. We compared the study with the conventional angiography after reconstructing the images required by using 3D-Med software Program(Rapidia). Seeing the consequences, the maximum enhancing time in the menigioma is about 120~180 seconds after injecting the contrast media and we distinguished the relation between vessels and tumors at the time and 1 case showed us the aneurysm with a tumor clearly at the time too. It was very helpful to the operation that the 3D images required by injecting the contrast media to the patients with meningioma distingushed between tumors and vessels dimensionally.

  • PDF

Determination of Aneurysmal Location with 3 Dimension-Computed Tomographic Angiography in the Microsurgery of Paraclinoid Aneurysms

  • Kim, Min-Young;Chung, Seung-Young;Kim, Seung-Min;Park, Moon-Sun;Jung, Sung-Sam
    • Journal of Korean Neurosurgical Society
    • /
    • v.42 no.1
    • /
    • pp.35-41
    • /
    • 2007
  • Objective : Determining the location of paraclinoid aneurysms for microsurgery is important for selecting treatment options, especially when deciding on the release of the dural ring in direct clipping. We examined the reliability of using the optic strut as an anatomical landmark for evaluating the location of paraclinoid aneurysms. Methods : Cadaveric dissection was performed to establish the relationship of the optic strut to the dural ring. Results from these anatomic studies were compared with the three-demensional computed tomographic angiographic [3D-CTA] findings of nine patients with ten paraclinoid aneurysms between May 2004 and October 2005. These, 3D-CTA results were then compared with intraoperative findings. Results : The inferior boundary of the optic strut accurately localized the point at the proximal dural ring in cadaveric study. The optic strut and its relationship to the aneurysms was well observed on the multiplanar reformats of 3D-CTA. During microsurgery, nine of ten aneurysms were verified to arise from distal to the upper surface of the optic strut. Two aneurysms that had arisen between the inferior and superior boundary of the optic strut were observed to lie within the carotid cave. One aneurysm which had arisen at the inferior boundary of the optic strut and directed inferiorly was observed to lie within the cavernous sinus just after the release of the proximal ring. Conclusion : The optic strut, as identified with multiplanar reformats of 3D-CTA, provided a reliable anatomic landmark for the proximal rings and an important information about the location of aneurysms around the anterior clinoid process (ACP). Therefore, 3D-CTA and the optic strut could become an invaluable tool and a landmark in the assessment of the location of paraclinoid aneurysms for microsurgery.

Surgical treatment of coarctation of aorta in infants -Four cases of subclavian flap aortoplasty- (유아에서의 대동맥 축착증 치험 4예)

  • 백광제
    • Journal of Chest Surgery
    • /
    • v.19 no.3
    • /
    • pp.506-514
    • /
    • 1986
  • Coarctation of aorta is rather common congenital cardiovascular defect in the western countries, but it is known to be rare in Korea. And no coarctation of Aorta has been reported and operated upon during early infancy in Korea. During 4 months period from May 1984 to September 1984, four small infants of coarctation of aorta were seen and treated surgically by subclavian flap aortoplasty in Guro Hospital, Korea University. All infants were male, ranging from 7 days to 54 days old [mean 29 days], weighing between 3.2 Kg and 5.0 Kg [mean 4.1 Kg], and all were in congestive heart failure. Examination of the femoral artery pulse gave in all cases clues to the diagnosis. By Two dimensional echocardiogram, detail anatomical features as well as the diagnosis were revealed and associated anomalies, for example, ventricular septal defect could be seen. Besides one case of isolated coarctation of aorta, other three infants had associated VSD. The 3 patients with VSD were treated by pulmonary artery banding in addition to aortoplasty. The postoperative course were smooth in all patients. In conclusion, coarctation of aorta may not be so rare in Korea as we thought previously. The importance of femoral pulse examination can not be overemphasized for the diagnosis. As we experienced, two-dimensional echocardiography in most cases can substitute those invasive examinations such as angiography and catheterization which carry difficulty and risk in infants.

  • PDF

4D Reconstruction of Cine Cardiac MR Images (심장 자기공명영상의 4차원 재구성)

  • Lee, D.H.;Kim, J.H.;Song, I.C.;Cho, S.S.;Park, J.H.;Han, M.C.;Min, B.G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.314-316
    • /
    • 1996
  • To diagnose cardiac malfunctions, various imaging techniques have been applied to heart : DSA(Digital Subtracted Angiography), Doppler Ultrasound, MR Angio. But it is difficult to observe three dimensional heart motion which is the most intuitive tool for diagnosis, only by using these methods. In this research, we have suggested 4-Dimensional reconstruction scheme of heart motion images that can be acquired by ECG-gated cine MR imaging. One cardiac cycle was devided into $9\sim15$ phases and for each phase 3D reconstructed volumn heart was made. We can observe 3D volumns along the cardiac cycle, time. So the results were 4-D reconstructed data.

  • PDF