• Title/Summary/Keyword: Three-dimensional angiography

Search Result 65, Processing Time 0.028 seconds

A Study on Non-Subtraction and Subtraction Technique in 3-Dimensional Angiography of the Cerebral Aneurysm (뇌동맥자루 3차원 혈관조영술에서 비감산 및 감산 기법에 관한 연구)

  • Kim, Kyung-Wan;Im, In-Chul;Lee, Hyo-Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.4
    • /
    • pp.511-518
    • /
    • 2018
  • The purpose of this study was to measured the diameter, maximum diameter, maximum area and volume of the cerebral aneurysm in 53 patients who underwent three-dimensional digital angiography and three-dimensional digital subtraction angiography, which were used for the clinical diagnosis of cerebral aneurysm, image noise and radiation exposure dose of each test method were analyzed to compare clinical diagnosis differences in the cerebral aneurysm diagnosis. Three-dimensional digital angiography and three-dimensional digital subtraction angiography showed that the neck diameter, maximum diameter, maximum area, volume, and noise of the cerebral aneurysm were identical or very small. However, the three-dimensional digital angiography significantly decreased the radiation exposure dose compared to three-dimensional digital subtraction angiography. Therefore, in case of clinical diagnosis of cerebral aneurysm, three-dimensional digital angiography should be preferentially used to reduce radiation exposure dose of patient.

Usefulness of 3-Dimensional Gadolinium-enhanced MR Angiography for the Evaluation of Pedal Artery. : Comparison with digital subtraction angiography (족부혈관 평가에 있어서의 3차원 Gadolinium 조영증강 자기공명혈관조영술의 유용성 : 디지털 감산 혈관조영술과의 비교)

  • Ji, Youn-Sang;Lee, Bong-Jae
    • Journal of radiological science and technology
    • /
    • v.24 no.2
    • /
    • pp.23-28
    • /
    • 2001
  • The purpose of this study is to compare the 3-dimensional MR angiography(MRA) with digital subtraction angiography(DSA) for the evaluation of pedal artery. MR angiography was performed using three-dimensional FISP acquisition before, and four sequential acquisitions after the injection of gadolinium(0.2 mmol/kg, 3 ml/sec). MRA was compared with DSA for a correct identification of the arterial segment. Out of 168 segments, 32 segmints were invisible in both MRA and DSA. At the level of ankle, 48 segments were visible in both examinations, and 18 segments were visible only in MRA. In the foot area, 34 segments were visible in MRA, but not in DSA. Three arterial segments were visible only in DSA. 3D MRA is comparable to DSA for the evaluation of pedal artery, thus it gives additional Information for the planning of treatment in lower extremity artery.

  • PDF

Two-Dimensional Image-Based Respiratory Navigator for Free-Breathing Coronary Magnetic Resonance Angiography

  • Shin, Taehoon
    • Investigative Magnetic Resonance Imaging
    • /
    • v.22 no.1
    • /
    • pp.71-77
    • /
    • 2018
  • Purpose: To develop a two-dimensional (2D) image-based respiratory motion correction technique for free-breathing coronary magnetic resonance angiography (MRA). Materials and Methods: The proposed respiratory navigator obtained aliased a 2D sagittal image from under-sampled k-space data and utilized motion correlation between the aliased images. The proposed navigator was incorporated into the conventional coronary MRA sequence including the diaphragm navigator and tested in three healthy subjects. Results: The delineation of major coronary arteries was significantly improved using the proposed 2D motion correction (S/I and A/P) compared to one-dimensional (S/I) correction using the conventional diaphragm navigator. Conclusion: The 2D image-based respiratory navigator was proposed for free-breathing coronary angiography and showed the potential for improving respiratory motion correction compared to the conventional 1D correction.

Role of Multislice Computerized Tomographic Angiography after Clip Placement in Aneurysm Patients Based on Comparison with Three Dimensional Digital Subtraction Angiography

  • Han, Myung-Hwan;Kim, Young-Don
    • Journal of Korean Neurosurgical Society
    • /
    • v.42 no.2
    • /
    • pp.103-111
    • /
    • 2007
  • Objective : We evaluated the accuracy of multislice computerized tomographic angiography (MCTA) in the postoperative evaluation of clipped aneurysms by comparising it with three dimensional digital subtraction angiography (3D-DSA). Methods : Between May 2004 and September 2006, we included patients with ruptured cerebral aneurysm of the anterior circulation that was surgically clipped and evaluated by both postoperative MCTA and postoperative 3D-DSA. We measured the diagnostic performance and calculated the sensitivity and specificity of postoperative MCTA compared to 3D-DSA in the detection of aneurysm remnants. Results : A total of 11 neck remnants among the 92 clipped aneurysms (11.9%) were confirmed by 3D-DSA. According to Sindou's classification of aneurysm remnants, 8.7% of clipped aneurysms (8/92) had only neck remnant on 3D-DSA and 3.2% (3/92 aneurysms) had residuum of the neck and sac on 3D-DSA. There were 12 (13.04%) equivocal cases that were difficult to interpret based on the postoperative MCTA. The reasons for the equivocal cases included multiple clips (6 cases, 50.0%). beam-hardening effect (4 cases, 33.3%), motion artifact (1 case, 8.3%), fenestrated clip (1 case, 8.3%) and other combined causes. The sensitivity and specificity of the postoperative MCTA was 81.8% and 88.9%, respectively by ROC curve (p=0.000). Conclusion : MCTA is an accurate noninvasive imaging method used for the assessment of clipped aneurysms in the anterior circulation. If the image quality of postoperative MCTA is good quality and the patient has been treated with a single titanium clip, except a fenestrated clip, the absence of an aneurysm remnant can be diagnosed by MCTA alone and the need for postoperative DSA can be reduced in a large percentage of cases.

Three-Dimensional Model Construction and Blood Flow Analysis of Coronary Artery using In-vivo Angiography (생체내 혈관조형술을 이용한 관상동맥의 3차원 형상화 및 혈류특성 해석)

  • Roh, Hyung-Woon;Suh, Sang-Ho;Kwon, Hyuck-Moon;Lee, Byung-Kwon
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.753-758
    • /
    • 2003
  • The purpose of the present study was to establish the mechanism of the generation of atherosclerosis by analyzing the hemodynamic variables in the coronary artery where atherosclerosis occurs frequently. From the previous results, the stenosis phenomena due to atherosclerosis were related to not only biochemical reaction between blood and blood vessel but also the hemodynamic factors like flow separation and oscillatory wall shear stress. The present study aimed to investigate the causes of the generation and progression of atherosclerosis in the coronary artery. This study also aimed to develop the softwares which generate automatically three dimensional vascular models obtained by the angiogram images and the computer vision techniques. In the present study, the flow patterns for full three-dimensional hemodynamic characteristics were analyzed. To understand the three-dimensional hemodynamic characteristics, the wall shear stress distributions and secondary flows were investigated quantitatively.

  • PDF

Rupturing Anterior Communicating Artery Aneurysm during Computed Tomography Angiography : Three-Dimensional Visualization of Bleeding into the Septum Pellucidum and the Lateral Ventricle

  • Kim, Ealmaan
    • Journal of Korean Neurosurgical Society
    • /
    • v.55 no.6
    • /
    • pp.357-361
    • /
    • 2014
  • Computed tomography angiography (CTA) is commonly used in setting of subarachnoid hemorrhage, but imaging features of aneurysm rupturing taking place at the time of scanning has rarely been described. The author reports a case of actively rebleeding aneurysm of the anterior communicating artery with intraventricular extravasation on the hyperacute CTA imaging. The rebleeding route, not into the third ventricle but into the lateral ventricles, can be visualized by real-time three-dimensional CT pictures. The hemorrhage broke the septum pellucidum and the lamina rostralis rather than the lamina terminalis.

Persistent Hypoglossal Artery

  • Ahn, Jae-Heung;Choe, Woo-Jin;Park, Hyo-Il;Lee, Chae-Heuck
    • Journal of Korean Neurosurgical Society
    • /
    • v.38 no.4
    • /
    • pp.312-315
    • /
    • 2005
  • The persistent hypoglossal artery[PHA] is a rare anomaly that belongs to the group of embryonic carotid-basilar artery anastomoses that may occur in adults. The most commonly reported type of such an anastomosis is the primitive trigeminal artery, followed by the PHA. We report a 35-year old man, hospitalized because of an intraventricular hemorrhage, who was found to have a right persistent PHA. Three-dimensional computed tomography[CT] angiography provided excellent anatomical topology of the anomaly. To our knowledge, this patient is the first case of a PHA identified by this means in Korea.

Traumatic Pseudoaneurysm of the Superficial Temporal artery Diagnosed by 3-dimensional CT Angiography

  • Park, In-Ho;Kim, Hyeun-Sung;Park, Sung-Kuen;Kim, Seok-Won
    • Journal of Korean Neurosurgical Society
    • /
    • v.43 no.4
    • /
    • pp.209-211
    • /
    • 2008
  • Pseudoaneurysm arising from the superficial temporal artery (STA) is a rare and potentially critical cause of palpable mass. Most pseudoaneurysms form as a result of blunt trauma and present as painless, pulsatile mass that may be associated with pathologic finding and enlarged size. We report a rare case of pseudoaneurysm arising from STA caused by blunt injury and diagnosed by 3-dimensional computed tomography (CT) angiography.

Detection of Aneurysms in Patients with Spontaneous Subarachnoid Hemorrhage : A Comparison of Three-dimensional Computed Tomographic Angiography and Conventional Angiography (자발성 뇌지주막하 출혈 환자에서 뇌동맥류 검출에 대한 고식적 혈관조영술과 3차원 전산화 단층 혈관조영술의 비교)

  • Lee, Kyoung Soo;Kang, Chang Gu;Huh, Ryoong;Lee, Sang Hoon;Chung, Ui Wha
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.6
    • /
    • pp.711-716
    • /
    • 2001
  • Objectives : Three-dimensional computed tomographic angiography(3D-CTA) is recently developed diagnostic imaging modality. We have studied this noninvasive method for possible role in replacing conventional angiography( CA) in the detection of aneurysms of the circle of Willis in patients with subarachnoid hemorrahge(SAH). Methods : We studied retrospectively, the 100 patients with SAH or unruptured aneurysms admitted to our hospital from October 1997 to December 1998. Among there, 85 patients underwent CTA, 82 patients underwent CA and 67 patients underwent both of CTA and CA. 3D-CTA was obtained using maximum intensity projection(MIP) and shaded-surface display(SSD) reconstruction. Results : Total 107 aneurysms were detected in 92 patients, and 64 aneurysms were detected in 67 patients underwent both CTA and CA. In five cases of those 67 cases, aneurysms were detected by CA but not by 3D-CTA. The detection rate of aneurysms(91.8%) and the detection rate of parent artery in cases of anterior communicating artery aneurysms(86.9%) with total 3D-CTA were relatively compatible with that of CA. But 3D-CTA was not enough in detection of posterior communicating artery aneurysms, internal carotid artery aneurysms as well as small sized aneurysm(<3mm). Conclusion : We consider CTA is valuable in as a screening test for cerebral aneurysm and follow-up test. And it is also valuable in early surgery for patients with aneurysmal rebleeding because of simple, quick, non-invasive method.

  • PDF