• Title/Summary/Keyword: Three-dimensional Computed Tomography

Search Result 510, Processing Time 0.024 seconds

Anatomic Characteristics of Supraorbital Foramina in Korean Using Three-Dimensional Model

  • Woo, Sang Woo;Lee, Hye Joo;Nahm, Francis Sahngun;Lee, Pyung Bok;Choi, Eun Joo
    • The Korean Journal of Pain
    • /
    • v.26 no.2
    • /
    • pp.130-134
    • /
    • 2013
  • Background: The aims of this study were to analyze the anatomic variations of supraorbital foramina/notches in Koreans and to compare the results with those of previous studies examining other races. We evaluated the three-dimensional computed tomography (3D-CT) images of human faces using multidetector computed tomography (MDCT). Methods: A total of 395 adults (232 men and 163 women) were enrolled and the 3D-CT images of their faces were reviewed in this study. In this study, the data from the images included the presence, shape, width and distance from the nasion to the supraorbital foramina/notches. ANOVA was used to assess the main effects of gender and side (right or left foramen/notch), and comparisons of the means were done by paired t-test. Results: The most common shapes in Koreans were a single notch (39.5%) on the right hand side and a single foramen (42.3%) on the left hand side. The incidence of a single foramen in Koreans was high compared to other races. The mean foramen diameter was $2.34{\pm}0.78$ mm, and the mean distance from the nasion was $27.19{\pm}4.03$ mm. The mean notch diameter was $3.37{\pm}1.71$ mm, and the mean distance from the nasion was $23.42{\pm}2.45$ mm. Conclusions: This is the first study on the variations of supraorbital foramina/notches in Koreans using 3D-CT images of faces. The anatomic characteristics of the supraorbital foramina/notch will help in performing nerve blocks and maxillofacial surgery.

Depth Dose According to Depth during Cone Beam Computed Tomography Acquisition and Dose Assessment in the Orbital Area Using a Three-Dimensional Printer

  • Min Ho Choi;Dong Yeon Lee;Yeong Rok Kang;Hyo Jin Kim
    • Journal of Radiation Protection and Research
    • /
    • v.49 no.2
    • /
    • pp.68-77
    • /
    • 2024
  • Background: Cone beam computed tomography (CBCT) is essential for correcting and verifying patient position before radiation therapy. However, it poses additional radiation exposure during CBCT scans. Therefore, this study aimed to evaluate radiological safety for the human body through dose assessment for CBCT. Materials and Methods: For CBCT dose assessment, the depth dose was evaluated using a cheese phantom, and the dose in the orbital area was evaluated using a human body phantom self-fabricated with a three-dimensional printer. Results and Discussion: The evaluation of radiation doses revealed maximum doses of 14.14 mGy and minimum doses of 6.12 mGy for pelvic imaging conditions. For chest imaging conditions, the maximum doses were 4.82 mGy, and the minimum doses were 2.35 mGy. Head imaging conditions showed maximum doses of 1.46 mGy and minimum doses of 0.39 mGy. The eyeball doses using a human body phantom model averaged at 2.11 mGy on the left and 2.19 mGy on the right. The depth dose ranged between 0.39 mGy and 14.14 mGy, depending on the change in depth for each imaging mode, and the average dose in the orbit area using a human body phantom was 2.15 mGy. Conclusion: Based on the experimental results, CBCT did not significantly affect the radiation dose. However, it is important to maintain a minimal radiation dose to optimize radiation protection following the as low as reasonable achievable principle.

The Value of Computed Tomography Scan in Three-dimensional Planning and Intraoperative Navigation in Primary Total Hip Arthroplasty

  • Fabio Mancino;Andreas Fontalis;Ahmed Magan;Ricci Plastow;Fares S. Haddad
    • Hip & pelvis
    • /
    • v.36 no.1
    • /
    • pp.26-36
    • /
    • 2024
  • Total hip arthroplasty (THA) is a frequently performed procedure; the objective is restoration of native hip biomechanics and achieving functional range of motion (ROM) through precise positioning of the prosthetic components. Advanced three-dimensional (3D) imaging and computed tomography (CT)-based navigation are valuable tools in both the preoperative planning and intraoperative execution. The aim of this study is to provide a thorough overview on the applications of CT scans in both the preoperative and intraoperative settings of primary THA. Preoperative planning using CT-based 3D imaging enables greater accuracy in prediction of implant sizes, leading to enhancement of surgical workflow with optimization of implant inventory. Surgeons can perform a more thorough assessment of posterior and anterior acetabular wall coverage, acetabular osteophytes, anatomical landmarks, and thus achieve more functional implant positioning. Intraoperative CT-based navigation can facilitate precise execution of the preoperative plan, to attain optimal positioning of the prosthetic components to avoid impingement. Medial reaming can be minimized preserving native bone stock, which can enable restoration of femoral, acetabular, and combined offsets. In addition, it is associated with greater accuracy in leg length adjustment, a critical factor in patients' postoperative satisfaction. Despite the higher costs and radiation exposure, which currently limits its widespread adoption, it offers many benefits, and the increasing interest in robotic surgery has facilitated its integration into routine practice. Conducting additional research on ultra-low-dose CT scans and examining the potential for translation of 3D imaging into improved clinical outcomes will be necessary to warrant its expanded application.

Micro-computed tomography analysis of changes in the periodontal ligament and alveolar bone proper induced by occlusal hypofunction of rat molars

  • Shimizu, Yasuhiro;Hosomichi, Jun;Nakamura, Saeko;Ono, Takashi
    • The korean journal of orthodontics
    • /
    • v.44 no.5
    • /
    • pp.263-267
    • /
    • 2014
  • Objective: To three-dimensionally elucidate the effects of occlusal hypofunction on the periodontal ligament and alveolar bone proper of rat molars by micro-computed tomography (micro-CT). Methods: Occlusal function in the molar area was restricted by attaching an anterior bite plate on the maxillary incisors and a metal cap on the mandibular incisors of 5-week-old male Wistar rats for 1 week. The periodontal ligament space and alveolar bone proper around roots of the mandibular first molar were assessed by histology and micro-CT. Results: The periodontal ligament space was narrower and the alveolar bone proper was sparser and less continuous in the hypofunction group than in the control group. Further, both the volume of the periodontal ligament and the volumetric ratio of the alveolar bone proper to the total tissue in the region of interest were significantly lower in the hypofunction group (p < 0.05). Conclusions: Occlusal hypofunction induces atrophic changes in the periodontal ligament and alveolar bone proper of rat molars.

Comparison of 2 root surface area measurement methods: 3-dimensional laser scanning and cone-beam computed tomography

  • Tasanapanont, Jintana;Apisariyakul, Janya;Wattanachai, Tanapan;Sriwilas, Patiyut;Midtbo, Marit;Jotikasthira, Dhirawat
    • Imaging Science in Dentistry
    • /
    • v.47 no.2
    • /
    • pp.117-122
    • /
    • 2017
  • Purpose: The aim of this study was to compare the use of 3-dimensional (3D) laser scanning and cone-beam computed tomography (CBCT) as methods of root surface measurement. Materials and Methods: Thirty teeth (15 maxillary first premolars and 15 mandibular first premolars) from 8 patients who required extractions for orthodontic treatment were selected. Before extraction, pre-treatment CBCT images of all the patients were recorded. First, a CBCT image was imported into simulation software (Mimics version 15.01; Materialise, Leuven, Belgium) and the root surface area of each tooth was calculated using 3-Matic (version 7.01, Materialise, Leuven, Belgium). After extraction, all the teeth were scanned and the root surface area of each extracted tooth was calculated. The root surface areas calculated using these 2 measurement methods were analyzed using the paired t-test (P<.05). Correlations between the 2 methods were determined by calculating the Pearson correlation coefficient. The intraclass correlation coefficient(ICC) was used to assess intraobserver reliability. Results: The root surface area measurements ($230.11{\pm}41.97mm^2$) obtained using CBCT were slightly greater than those ($229.31{\pm}42.46mm^2$) obtained using 3D laser scanning, but not significantly (P=.425). A high Pearson correlation coefficient was found between the CBCT and the 3D laser scanner measurements. The intraobserver ICC was 1.000 for 3D laser scanning and 0.990 for CBCT. Conclusion: This study presents a novel CBCT approach for measuring the root surface area; this technique can be used for estimating the root surface area of non-extracted teeth.

QUANTITATIVE ASSESSMENT OF NASAL AND UPPER LIP CHANGES AFTER LE FORT I OSTEOTOMY SURGERY USING A 3-DIMENSIONAL COMPUTED TOMOGRAPHY (르포씨 1형 골절단술후 코와 상순의 연조직 변화의 삼차원 컴퓨터 단층촬영을 이용한 정량적 측정에 관한 연구)

  • Lee, Won-Deok;Yoo, Chung-Kyu;Choi, Jin-Young
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.32 no.1
    • /
    • pp.49-56
    • /
    • 2010
  • Objective: To evaluate nasal and upper lip changes after Le Fort I surgery by means of images taken with a three-dimensional computed tomography (3D-CT). Methods: Fifteen patients (9 female and 6 male, mean age 21.9 years) with preoperative and postoperative 3D-CT were studied. The patients underwent maxillary movement with impaction or elongation, and advancement or setback. With the 3D-CT which presents reconstructive soft tissue images, preoperative and postoperative measurement and analysis were performed for nasal tip projection angle, columellar angle, supratip break angle, nasolabial angle, interalar width, internostril width, columella length and nasal tip projection. Results: Postoperative interalar and internostril widening was significant for all categories of maxillary movement. However, there was little significant relation in all parameters between the amount and direction of maxillary movement. Interestingly, movement of the maxilla with upward did show a little decrease in the columellar angle, supra tip break angle and nasolabial angle. Also movement of the maxilla with forward did show a little advancement in the upper lip position. Conclusion: Changes to the nose clearly occur after orthognathic surgery. There was a significant increase in postoperative interalar width and internostril width with maxillary movement. However, no clear correlation could be determined between amount of change and maxillary movement. Interestingly, maxillary impaction did show a little decrease in the columellar angle, supra tip break angle and nasolabial angle. In addition, we used 3D-CT for more precise analysis as a useful tool.

Efficient approach for determining four-dimensional computed tomography-based internal target volume in stereotactic radiotherapy of lung cancer

  • Yeo, Seung-Gu;Kim, Eun Seog
    • Radiation Oncology Journal
    • /
    • v.31 no.4
    • /
    • pp.247-251
    • /
    • 2013
  • Purpose: This study aimed to investigate efficient approaches for determining internal target volume (ITV) from four-dimensional computed tomography (4D CT) images used in stereotactic body radiotherapy (SBRT) for patients with early-stage non-small cell lung cancer (NSCLC). Materials and Methods: 4D CT images were analyzed for 15 patients who received SBRT for stage I NSCLC. Three different ITVs were determined as follows: combining clinical target volume (CTV) from all 10 respiratory phases ($ITV_{10Phases}$); combining CTV from four respiratory phases, including two extreme phases (0% and 50%) plus two intermediate phases (20% and 70%) ($ITV_{4Phases}$); and combining CTV from two extreme phases ($ITV_{2Phases}$). The matching index (MI) of $ITV_{4Phases}$ and $ITV_{2Phases}$ was defined as the ratio of $ITV_{4Phases}$ and $ITV_{2Phases}$, respectively, to the $ITV_{10Phases}$. The tumor motion index (TMI) was defined as the ratio of $ITV_{10Phases}$ to $CTV_{mean}$, which was the mean of 10 CTVs delineated on 10 respiratory phases. Results: The ITVs were significantly different in the order of $ITV_{10Phases}$, $ITV_{4Phases}$, and $ITV_{2Phases}$ (all p < 0.05). The MI of $ITV_{4Phases}$ was significantly higher than that of $ITV_{2Phases}$ (p < 0.001). The MI of $ITV_{4Phases}$ was inversely related to TMI (r = -0.569, p = 0.034). In a subgroup with low TMI (n = 7), $ITV_{4Phases}$ was not statistically different from $ITV_{10Phases}$ (p = 0.192) and its MI was significantly higher than that of $ITV_{2Phases}$ (p = 0.016). Conclusion: The $ITV_{4Phases}$ may be an efficient approach alternative to optimal $ITV_{10Phases}$ in SBRT for early-stage NSCLC with less tumor motion.

Comparison of cone-beam computed tomography cephalometric measurements using a midsagittal projection and conventional two-dimensional cephalometric measurements

  • Jung, Pil-Kyo;Lee, Gung-Chol;Moon, Cheol-Hyun
    • The korean journal of orthodontics
    • /
    • v.45 no.6
    • /
    • pp.282-288
    • /
    • 2015
  • Objective: This study investigated whether it is possible to use a two-dimensional (2D) standard in three-dimensional (3D) analysis, by comparing the angles and lengths measured from a midsagittal projection in 3D cone-beam computed tomography (CBCT) with those measured by 2D lateral cephalometric radiography (LCR). Methods: Fifty patients who underwent both LCR and CBCT were selected as subjects. CBCT was reoriented in 3 different methods and the measuring-points were projected onto the midsagittal plane. Twelve angle values and 8 length values were measured on both LCR and CBCT and compared. Results: Repeated measures analysis of the variance revealed statistically significant differences in 7 angular and 5 linear measurements among LCR and 3 types of CBCT (p < 0.05). Of these 12 measurements, multiple comparisons showed that 6 measurements (ANB, AB to FH, IMPA, FMA, Co-Gn, Go-Me) were not significantly different in pairwise comparisons. LCR was significantly different from 3 types of CBCT in 3 angular (SN to FH, interincisal angle, FMIA) and 2 linear (S-Go, Co-ANS) measurements. The CBCT method was similar for all measurements, except for 1 linear measurement, i.e., S-N. However, the disparity between the mean values for all parameters was within the range of clinical measurement error. Conclusions: 3D-CBCT analysis, using midsagittal projection, is a useful method in which the 2D-LCR normative values can be used. Although the measurements changed with reorientation, these changes were not clinically significant.

Usefulness of sectional images in dural AVF for the interpretation of venous anatomy

  • Myongjin Kang;Sanghyeon Kim
    • Journal of Cerebrovascular and Endovascular Neurosurgery
    • /
    • v.26 no.2
    • /
    • pp.119-129
    • /
    • 2024
  • Knowledge of the venous anatomy is essential for appropriately treating dural arteriovenous fistulas (AVFs). It is challenging to determine the overall venous structure despite performing selective angiography for dural AVFs with feeder from multiple selected arteries. This is because only a part of the veins can be observed through the shunt in the selected artery. Therefore, after performing selective angiography of all vessels to understand the approximate venous anatomy, the venous anatomy can be easily understood by closely examining the source image of computed tomographic angiography or magnetic resonance angiography. Through this, it is possible to specify the vein that is to be blocked (target embolization), thereby avoiding extensive blocking of the vein and avoiding various complications. In the case of dural AVF with feeder from single selected artery, if the multiplanar reconstruction image of the three-dimensional rotational computed tomography obtained by performing angiography is analyzed thoroughly, a shunted pouch can be identified. If embolization is performed by targeting this area, unnecessary sinus total packing can be avoided.

Comparative study of glenoid version and inclination using two-dimensional images from computed tomography and three-dimensional reconstructed bone models

  • Choi, Chang-Hyuk;Kim, Hee-Chan;Kang, Daewon;Kim, Jun-Young
    • Clinics in Shoulder and Elbow
    • /
    • v.23 no.3
    • /
    • pp.119-124
    • /
    • 2020
  • Background: This study was performed to compare glenoid version and inclination measured using two-dimensional (2D) images from computed tomography (CT) scans or three-dimensional (3D) reconstructed bone models. Methods: Thirty patients who had undergone conventional CT scans were included. Two orthopedic surgeons measured glenoid version and inclination three times on 2D images from CT scans (2D measurement), and two other orthopedic surgeons performed the same measurements using 3D reconstructed bone models (3D measurement). The 3D-reconstructed bone models were acquired and measured with Mimics and 3-Matics (Materialise). Results: Mean glenoid version and inclination in 2D measurements were -1.705° and 9.08°, respectively, while those in 3D measurements were 2.635° and 7.23°. The intra-observer reliability in 2D measurements was 0.605 and 0.698, respectively, while that in 3D measurements was 0.883 and 0.892. The inter-observer reliability in 2D measurements was 0.456 and 0.374, respectively, while that in 3D measurements was 0.853 and 0.845. Conclusions: The difference between 2D and 3D measurements is not due to differences in image data but to the use of different tools. However, more consistent results were obtained in 3D measurement. Therefore, 3D measurement can be a good alternative for measuring glenoid version and inclination.