Paraganglioma of the Thoracolumbar Spinal Canal -A Case Report- (흉요추부에 발생한 부신경절종 - 증례 보고 -)

  • Jeong, Soon-Taek;Kim, Dong-Hee;Cho, Se-Hyun;Park, Hyung-Bin;Hwang, Sun-Chul;Lee, Jeong-Hee
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.13 no.2
    • /
    • pp.130-134
    • /
    • 2007
  • Paragangliomas arise from a multicentric system of paraganglion cells derived from the neuroectoderm. Although these tumors are the most common in the head and neck region, they may occur in diverse locations including mediastinum, retroperitoneum and visceral organs. Spinal paragangliomas arising in the intradural space of the thoracolumbar spine have been reported rarely, with the majority located in the cauda equina. Only few cases of thoracic paraganglioma have been previously reported. We present an additional case of thoracolumbar paraganglioma and review the clinical MRI and histopathological features of this unusual tumor.

  • PDF

Impact of Screw Type on Kyphotic Deformity Correction after Spine Fracture Fixation: Cannulated versus Solid Pedicle Screw

  • Arbash, Mahmood Ali;Parambathkandi, Ashik Mohsin;Baco, Abdul Moeen;Alhammoud, Abduljabbar
    • Asian Spine Journal
    • /
    • v.12 no.6
    • /
    • pp.1053-1059
    • /
    • 2018
  • Study Design: Retrospective review. Purpose: To detect the effect of cannulated (poly-axial head) and solid (mono-axial head) screws on the local kyphotic angle, vertebral body height, and superior and inferior angles between the screw and the rod in the surgical management of thoracolumbar fractures. Overview of Literature: Biomechanics studies showed that the ultimate load, yield strength, and cycles to failure were significantly lower with cannulated (poly-axial head) pedicle comparing to solid core (mono-axial head). Methods: The medical charts of patients with thoracolumbar fractures who underwent pedicle screw fixation with cannulated or solid pedicle screws were retrospectively reviewed; the subjects were followed up from January 2011 to December 2015. Results: Total 178 patients (average age, $36.1{\pm}12.4years$; men, 142 [84.3%]; women, 28 [15.7%]) with thoracolumbar fractures who underwent surgery and were followed up at Hamad Medical Corporation were classified, based on the screw type as those with cannulated screws and those with solid screws. The most commonly affected level was L1, followed by L2 and D12. Surgical correction of the local kyphotic angle was significantly different in the groups; however, there was no significant difference in the loss of correction of the local kyphotic angle of the groups. Surgical correction of the reduction in the vertebral body height showed statistical significance, while the average loss of correction in the reduction of the vertebral body height was not significantly different. The measurement of the angles made by the screws on the rods was not significantly different between the cannulated (poly-axial head) and solid (mono-axial head) screw groups. Conclusions: Solid screws were superior in terms of providing increased correction of the kyphotic angle and height of the fractured vertebra than the cannulated screws; however, no difference was noted between the screws in the maintenance of the superior and inferior angles of the screw with the rod.

Spinal Enumeration by Morphologic Analysis of Spinal Variants: Comparison to Counting in a Cranial-To-Caudal Manner

  • Yun, Sam;Park, Sekyoung;Park, Jung Gu;Huh, Jin Do;Shin, Young Gyung;Yun, Jong Hyouk
    • Korean Journal of Radiology
    • /
    • v.19 no.6
    • /
    • pp.1140-1146
    • /
    • 2018
  • Objective: To compare the spinal enumeration methods that establish the first lumbar vertebra in patients with spinal variants. Materials and Methods: Of the 1446 consecutive patients who had undergone computed tomography of the spine from March 2012 to July 2016, 100 patients (62 men, 38 women; mean age, 47.9 years; age range, 19-88 years) with spinal variants were included. Two radiologists (readers 1 and 2) established the first lumbar vertebra through morphologic analysis of the thoracolumbar junction, and labeled the vertebra by counting in a cranial-to-caudal manner. Inter-observer agreement was established. Additionally, reader 1 detected the 20th vertebra under the assumption that there are 12 thoracic vertebra, and then classified it as a thoracic vertebra, lumbar vertebra, or thoracolumbar transitional vertebra (TLTV), on the basis of morphologic analysis. Results: The first lumbar vertebra, as established by morphologic analysis, was labeled by each reader as the 21st segment in 65.0% of the patients, as the 20th segment in 31.0%, and as the 19th segment in 4.0%. Inter-observer agreement between the two readers in determining the first lumbar vertebra, based on morphologic analysis, was nearly perfect (${\kappa}$ value: 1.00). The 20th vertebra was morphologically classified as a TLTV in 60.0% of the patients, as the first lumbar segment in 31.0%, as the second lumbar segment in 4.0%, and as a thoracic segment in 5.0%. Conclusion: The establishment of the first lumbar vertebra using morphologic characteristics of the thoracolumbar junction in patients with spinal variants was consistent with the morphologic traits of vertebral segmentation.

Clinical assessment and grading of back pain in horses

  • Mayaki, Abubakar Musa;Razak, Intan Shameha Abdul;Adzahan, Noraniza Mohd;Mazlan, Mazlina;Rasedee, Abdullah
    • Journal of Veterinary Science
    • /
    • v.21 no.6
    • /
    • pp.82.1-82.10
    • /
    • 2020
  • Background: The clinical presentation of horses with back pain (BP) vary considerably with most horse's willingness to take part in athletic or riding purpose becoming impossible. However, there are some clinical features that are directly responsible for the loss or failure of performance. Objectives: To investigate the clinical features of the thoracolumbar region associated with BP in horses and to use some of the clinical features to classify equine BP. Methods: Twenty-four horses comprised of 14 with BP and 10 apparently healthy horses were assessed for clinical abnormality that best differentiate BP from normal horses. The horses were then graded (0-5) using the degree of pain response, muscular hypertonicity, thoracolumbar joint stiffness and overall physical dysfunction of the horse. Results: The common clinical features that significantly differentiate horses with BP from non-BP were longissimus dorsi spasm at palpation (78.6%), paravertebral muscle stiffness (64.3%), resist lateral bending (64.3%), and poor hindlimb impulsion (85.7%). There were significantly (p < 0.05) higher scores for pain response to palpation, muscular hypertonicity, thoracolumbar joint stiffness and physical dysfunction among horses with BP in relation to non-BP. A significant relationship exists between all the graded abnormalities. Based on the cumulative score, horses with BP were categorized into mild, mild-moderate, moderate and severe cases. Conclusions: BP in horse can be differentiated by severity of pain response to back palpation, back muscle hypertonicity, thoracolumbar joint stiffness, physical dysfunctions and their cumulative grading score is useful in the assessment and categorization of BP in horses.

Accuracy of Thoracolumbar Spine K-Wire Placement in Toy, Small and Medium Breed Dogs: Novice Surgeons with 3D Printed Patient-Specific Guide versus an Experienced Surgeon with Freehand Techniques

  • Hwa-Joeng Shin;Hae-Beom Lee;Yoon-Ho Roh
    • Journal of Veterinary Clinics
    • /
    • v.39 no.6
    • /
    • pp.294-301
    • /
    • 2022
  • Three-dimensional (3D) printing technique has been widely used for accurate screw and pin placement in orthopedic surgery and neurosurgery. However, there are few reports comparing the accuracy between the patient-specific guides and freehand Kirschner wire (K-wire) placement in toy, small and medium breed dogs. This study aimed to assess the accuracy of 3D printed patient-specific guides (PSGs) in pin insertion in the thoracolumbar vertebrae of toy breed dogs and compare the outcomes between novice and experienced surgeons. The experiment was conducted on the thoracolumbar vertebrae of 21 euthanized toy breed dogs (median weight, 5.95 kg). The optimal insertion angle placement was determined and patient-specific guides for K-wire insertion were designed and 3D printed using computed tomography (CT) and a 3D computer-aided design program of three vertebrae (Thoracic 12-Lumbar 1). K-wire tracts were made by experienced and novice surgeons and compared to assess the accuracy based on postoperative CT. Based on postoperative CT, in the experienced group, 61 out of 63 pins (96.8%) were fully contained inside the vertebral body and lamina, whereas two pins (3.2%) had perforated the vertebral canal (grade 3, 2-4 mm breach). However, all the pins in the novice group were fully contained. The use of 3D printed PSGs for pin insertion in the thoracolumbar region is an accurate and safe alternative to freehand screw placement by novice surgeons in toy, small and medium breed dogs. Operations with 3D printed PSGs allow novice surgeons to achieve better or similar outcomes in accurate placement of pin/screws in vertebrae.

Minimally invasive percutaneous endoscopic thoracolumbar foraminotomy in large-breed dogs-a comparative study

  • Soo Hee Lee;Soo Young Choi;Ho Hyun Kwak;Heung Myong Woo
    • Korean Journal of Veterinary Service
    • /
    • v.47 no.2
    • /
    • pp.61-72
    • /
    • 2024
  • This study aimed to evaluate the feasibility of percutaneous endoscopic foraminotomy (PEF) for the treatment of intervertebral disc herniation of the thoracolumbar spine in large-breed dogs by comparing it with open hemilaminectomy (OH). Six large-breed canine cadavers were used in the present study. A barium and agarose mixture (BA-gel) simulating intervertebral disc herniation was injected into the spinal canal at two intervertebral spaces (T12-T13, L2-L3) of the thoracolumbar spine in each cadaver. PEF and OH were randomly allocated to the sites in each cadaver. Computed tomography was performed pre- and postoperatively. The incision length, vertebral window size, procedure time, and amount of simulated disc material removed were recorded to compare PEF and OH. Both procedures clearly exposed the simulated disc material and spinal cord. The size of the incision and vertebral window created after PEF was much smaller than those after OH. The surgical duration of PEF was longer than that of OH. However, no significant difference (P>0.05) was observed in the amount of BA-gel removed between PEF and OH. Thus, PEF could be used as an effective surgical option for intervertebral disc herniation of the thoracolumbar region in large-breed dogs in that it could lead to less tissue damage as well as sufficient removal of the simulated disc material.

Anterolateral Surgical Decompression and Instrumentation in Thoracolumbar Bursting Fracture (외상성 흉요추접합부 파열골절의 전측방경유법에 의한 신경감압 및 기구고정술)

  • Bae, Jang-Ho
    • Journal of Yeungnam Medical Science
    • /
    • v.13 no.2
    • /
    • pp.234-242
    • /
    • 1996
  • Ten patients with a thoracolumbar spine fractures were treated with Kaneda internal fixation device through anterolateral approach during last 1 year. In all cases, spinal decompression, internal instrument fixation and hone fusion with rib were performed. No patient showed neurological deterioration after surgery and 6(60%) patients improved postoperatively with entering the next Frankel subgroup. Follwo-up patient evaluation showed the correction of the fracture deformity with good bony fusion, but 3 patient arc remained back pain. According to above results we concluded that anterolateral internal fixation combined with hone fusion using rib was good mechanical stability and decompression of protruding ventral bone fragments above conus medullaris level.

  • PDF

Noncommunicating Spinal Extradural Meningeal Cyst in Thoracolumbar Spine

  • Kim, Il-Sup;Hong, Jae-Taek;Son, Byung-Chul;Lee, Sang-Won
    • Journal of Korean Neurosurgical Society
    • /
    • v.48 no.6
    • /
    • pp.534-537
    • /
    • 2010
  • Spinal extradural meningeal cyst has been rarely reported, whose etiologies are assumed to be the communication of cerebrospinal fluid (CSF) between intradural subarchnoid space and cyst due to the congenital defect in dura mater. Although the CSF communication due to this defect can be found, in most case, few cases in which there is a lack of the communication have also been reported. We report a case of the huge extradural meningeal cyst occurring in the thoracolumbar spine (from T10 to L2) where there was a lack of the communication between the intradural subarachnoid space and cyst in a 46-year-old man who presented with symptoms that were indicative of progressive paraparesis and leg pain. The patient underwent laminectomy and cyst excision. On intraoperative findings, the dura was intact and there was a lack of the communication with intradural subarachnoid space. Immediately after the surgery, weakness and leg pain disappeared shortly.

The clinical efficacy of thoracolumbar fascia release for shoulder pain

  • Choi, Don Mo;Jung, Ji Hye
    • Physical Therapy Rehabilitation Science
    • /
    • v.4 no.1
    • /
    • pp.55-59
    • /
    • 2015
  • Objective: This study aimed to elucidate the effects of thoracolumbar fascia release (TLFR) on the degree of pain and disability in patients with shoulder pain. Design: Randomized control trial. Methods: Thirty subjects with shoulder pain participated in this study. They were allocated to TLFR group (n=15) and manual physical therapy (MPT) group (n=15). Shoulder pain and disability index (SPADI) and the score on the visual analogue scale (VAS) were measured before and after TLFR. Results: In the TLFR group, the degree of shoulder pain as indicated by SPADI measured after the intervention significantly differed from that before the intervention (p<0.05); moreover, in the MPT group, the degree of shoulder pain was significantly lower (p<0.05). The data of the 2 groups before the intervention significantly differed from those after the intervention (p<0.05). SPADI significantly differed within the groups (p<0.05), but not between the groups. The sum of SPADI did not differ significantly between the groups. The VAS scores of shoulder pain measured before the intervention significantly differed from those measured after the intervention (p<0.05) in the both groups. After the intervention, shoulder pain decreased significantly in the TLFR group as compared to that in the MPT group. Conclusions: TLF release was effective in reducing shoulder pain. The results of this study can be applied in clinical practice for TLFR performed to reduce shoulder pain. Further studies will need to be performed to elucidate the effects of TLFR on functional recovery.

Anterior Decompression and Internal Fixation with Anterior Instrument and Surgical Titanium Mesh in Thoracolumbar Unstable Spine Injuries (Long-term Follow-up Results) (흉·요추 불안정성 척추 손상 환자에서 전방 감압술과 전방기기 및 Surgical Titanium Mesh를 이용한 내고정술 (장기적 추적 검사 결과))

  • Park, Hwan Min;Lee, Seung Myung;Cho, Ha Young;Shin, Ho;Jeong, Seong Heon;Song, Jin Kyu;Jang, Seok Jeong
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.1
    • /
    • pp.58-65
    • /
    • 2000
  • Objective : Thoracolumbar junction is second most common level of injury next to cervical spine. The object of this study is to study the usefulness of surgical titanium mesh instead of bone graft, as well as to evaluate the correction of spinal deformity and safety of early ambulation in patients with injury at thoracolumbar junction. Patients and Methods : This review included 51 patients who were operated from July 1994 to December 1997. The injured spine is considered to be unstable, if it shows involvement of two or more columns, translatory displacement more than 3.5mm, decrease more than 35% in height of vertebral body and progression of malalignment in serial X-ray. The decision to operate was determined by (1) compression of spinal cord or cauda eguina, (2) unstable fracture, (3) malalignment and (4) fracture dislocation. The procedure consisted of anterior decompression through corpectomy and internal fixation with anterior instrument and surgical titanium mesh which was impacted with gathered bone chip from corpectomy. Results : Fifty-one patients were followed up for at least 12 months. The main causes of injury were fall and vehicle accident. The twelfth thoracic and the first and the second lumbar vertebrae were frequently involved. Complete neural decompression was possible under direct vision in all cases. Kyphotic angulation occurred in a patient. Radiologic evaluation showed correction of deformity and no distortion or loosening of surgical titanium mesh with satisfactory fixation postoperatively. Conclusions : We could obtain neurological improvement, relief of pain, immediate stabilization and early return to normal activities postoperatively. Based on these results, authors recommend anterior decompression and internal fixation with surgical titanium mesh in thoracolumbar unstable spine injuries.

  • PDF