• Title/Summary/Keyword: Thoracic endovascular repair

Search Result 74, Processing Time 0.021 seconds

Endovascular Placement of Self-Expandable Stent-Graft for the Treatment of Aortic Aneurysms -2 cases- (자가팽창성 Stent-graft의 경관적 설치술을 이용한 대동맥류의 치료 -2 예 보고-)

  • 신현우;이재성
    • Journal of Chest Surgery
    • /
    • v.33 no.1
    • /
    • pp.99-102
    • /
    • 2000
  • The usual treatment for aortic aneurysms is surgical replacement with a prosthetic graft; however the associated morbidity and mortality rates must be considered. Endovascular placement of self-expandable stent-graft is a safe noninvasive treatment that can be an alternative to the surgical repair, the postoperative course of the 2 cases of thoracoabdominal aortic aneurysms was uneventful and no complication has been associated with the stent-graft during the 17 months and 5 months follow-up studies,.

  • PDF

Recurrent Aortobronchial Fistula after Endovascular Stenting for Infected Pseudoaneurysm of the Proximal Descending Thoracic Aorta: Case Report

  • Lee, Sun-Geun;Lee, Seung Hyong;Park, Won Kyoun;Kim, Dae Hyun;Song, Jae Won;Cho, Sang-Ho
    • Journal of Chest Surgery
    • /
    • v.54 no.5
    • /
    • pp.425-428
    • /
    • 2021
  • Aortobronchial fistula (ABF) induced by an infected pseudoaneurysm of the thoracic aorta is a life-threatening condition. As surgical treatment is associated with significant mortality and morbidity, thoracic endovascular aneurysm repair (TEVAR) may be an alternative for the treatment of ABF. However, the long-term durability of this intervention is largely unknown and the recurrence of ABF is a potential complication. We experienced a case of recurrent ABF after stent grafting as an early procedure for an infected pseudoaneurysm of the thoracic aorta. Remnant ABF, bronchial and/or aortic wall erosion, vasa vasorum connected with ABF, and recurrent local inflammation of the thin aortic wall around ABF might cause recurrent hemoptysis. As a result, we suggest that TEVAR should be considered as a bridge therapy for the initial treatment of ABF resulting from an infected pseudoaneurysm, and that several options, such as second-stage surgery, should be considered to prevent the recurrence of ABF.

Hybrid Procedure for Aortic Arch Aneurysm: Arch Vessels Debranching andThoracic Endovascular Aortic Repair? -2 case Reports- (대동맥궁 대동맥류에서 Hybrid 술식의 적용 - 2예 보고 -)

  • Kim, Seok;Kwon, Oh-Choon;Lee, Sub;Cho, Jun-Woo;Bae, Chi-Hoon;Park, Ki-Sung
    • Journal of Chest Surgery
    • /
    • v.43 no.5
    • /
    • pp.529-533
    • /
    • 2010
  • Conventional surgery for aortic arch aneurysms have many postoperative complications and a high mortality rate due to prolonged cardiopulmonary bypass time, especially in high risk patients. In this report, we present two cases of a hybrid procedure that involves open brachiocephalic bypass with concomitant endovascular arch stent grafting in high risk patients with distal aortic arch aneurysm.

Stented Aortic Graft Insertion in an Infrarenal Abdominal Aortic Aneurysm as Performed by Cardiovascular Surgeons - Report of 3 cases- (흉부외과 의사에 의해 시행된 복부 대동맥류의 스텐트 그라프트 삽입술 -3예 보고 -)

  • Chung, Eui-Suk;Lim, Cheong;Seong, Yong-Won;Choi, Jin-Ho;Park, Kay-Hyun;Chung, Woo-Young
    • Journal of Chest Surgery
    • /
    • v.41 no.3
    • /
    • pp.377-380
    • /
    • 2008
  • Abdominal aortic aneurysm has traditionally been treated by open repair. Aortic endovascular stent grafting has recently been introduced as a new modality. We report here on three cases of endovascular stent grafting that were performed by cardiovascular surgeons for the treatment of abdominal aortic aneurysm in the high risk patients with multiple comorbidities such as old age, hypertension, renal failure, cerebrovascular accident and immobility.

Percutaneous Endovascular Stent-graft Treatment for Aortic Disease in High Risk Patients: The Early and Mid-term Results (고위험군의 대동맥류 환자에서 경피적으로 삽입이 가능한 스텐트 그라프트를 이용한 치료: 조기 및 중기성적)

  • Choi, Jin-Ho;Lim, Cheong;Park, Kay-Hyun;Chung, Eui-Suk;Kang, Sung-Gwon;Yoon, Chang-Jin
    • Journal of Chest Surgery
    • /
    • v.41 no.2
    • /
    • pp.239-246
    • /
    • 2008
  • Background: Aortic surgery for high risk patients has high mortality and morbidity rates, and the necessity of performing aortic surgery in cancer patients is questionable because of their short life expectancy. Endovascular repair of aneurysm repair can be considered for high risk patients and cancer patients because it has relatively lower invasiveness and shorter recovery times than aortic surgery does. Especially, percutaneous endovascular stent graft treatment is more useful for high risk patients because it does not require general anesthesia. Material and Method: From July 2003 to September 2007, twelve patients who had inoperable malignancy or who had a high risk of complication because of their combined diseases during aortic surgery underwent endovascular aortic aneurysm repair. he indications for endovascular repair were abdominal aortic aneurysm in 5 patients, descending thoracic aortic aneurysm in 6 patients and acute type B aortic dissection in one patient. The underlying combined disease of these patients were malignancy in 3 patients, respiratory disease in 6 patients, old age with neurologic disease in 6 patients, Behcet's iseae in one patient and chronic renal failure in one patient. Result: Stent grafts were inserted percutaneously in all cases. There were 4 hospital deaths and there were 3 delayed deaths during the follow-up periods. There were no deaths from aortic disease, except one hospital death. There were several complications: a mild cerebrovascular accident occurred in one patient, acute renal failure occurred in 2 patients and ischemic bowel necrosis occurred in one patient. Mild type I endoleak was observed in 2 patients and type II endoleak was observed in a patient after stent graft implantation. Newly developed type I endoleak was observed in a patient during the follow-up period. Conclusion: Percutaneous endovascular stent graft insertion is relatively safe procedure for high risk patients and cancer patients. Yet it seems that its indications and its long term results need to be further researched.

Aorta-esophageal Fistula That Developed after Endovascular Stent-grafting of a Mycotic Aneurysm - A case report- (감염성 대동맥류에 혈관 내 스텐트 삽입 시행 후 발생한 대동맥-식도루 - 1예 보고 -)

  • Nam, Jin-Hae;Park, Kay-Hyun;Yoo, Jae-Suk;Lee, Jae-Hang;Lim, Cheong;Jheon, Sang-Hoon
    • Journal of Chest Surgery
    • /
    • v.43 no.6
    • /
    • pp.781-784
    • /
    • 2010
  • A 74-year-old woman presented at our hospital with hemoptysis. Three months ago, she had endovascular stent-grafting done by a general surgeon for a saccular thoracic aneurysm that was found accidentally following an episode of fever and chills. Despite a lasting fever after the procedure, she was discharged without further treatment and follow-up. She was subsequently admitted to the hospital for evaluation and several exams were performed. Chest CT scans and an esophagoscopy identified an aorto-esophageal fistula at the level of the aorta that was covered by a previous stent-graft. After extensive administration of antibiotics, surgery was done - esophagectomy, cervical esophago-gastrostomy and replacement of the thoracic aorta. She was later discharged uneventfully.

The Effect of Left Subclavian Artery Coverage During Endovascular Repair of the Thoracic Aortic Aneurysm on Cerebral Hemodynamics: Two Cases of Flow Measurement by using 2D Phase Contrast Magnetic Resonance Imaging (흉부대동맥류의 혈관내치료 도중 좌측 쇄골하동맥 폐색이 뇌혈류역동에 미치는 효과: 2차원 위상차 대조 자기공명영상을 이용한 혈류 측정 2례 보고)

  • Baek, Seung-Hoon;Youn, Sung-Won;Kim, Ho-Kyun;Kwon, Oh-Choon;Lee, Sub;Lee, Jong-Min
    • Investigative Magnetic Resonance Imaging
    • /
    • v.16 no.2
    • /
    • pp.159-168
    • /
    • 2012
  • The proximity of thoracic aortic aneurysm to the left subclavian artery (LSA) has made the coverage of LSA during thoracic endovascular aortic repair (TEVAR) be essential. Despite controversy concerning the safety of LSA coverage and the indications for LSA revascularizations, the cerebral hemodynamic change after LSA coverage has not been demonstrated. We prospectively examined two patients who would undergo TEVAR with LSA coverage by using 2D cine phase contrast MR imaging. After LSA coverage, the left subclavian steal was properly compensated by the increased flow volumes of both carotid arteries and right vertebral artery, which is the major collateral supply. The total brain supply after TEVAR did not lessen, which showed good correlation with uneventful clinical outcome. Therefore, 2D phase contrast MR imaging can be recommended as a useful technique to evaluate the hemodynamic change of the LSA coverage during TEVAR and to triage the candidate for LSA revascularization.

Thoracic EndoVascular Stent Graft Repair for Aortic Aneurysm

  • Kim, Joung-Taek;Yoon, Yong-Han;Lim, Hyun-Kyung;Yang, Ki-Hwan;Baek, Wan-Ki;Kim, Kwang-Ho
    • Journal of Chest Surgery
    • /
    • v.44 no.2
    • /
    • pp.148-153
    • /
    • 2011
  • Background: The number of cases employing thoracic endovascular aortic repair (TEVAR) has been increasing due to lower morbidity and mortality compared to open repair technique. The aim of this study is to evaluate the outcome of TEVAR for thoracic aortic diseases. Materials and Methods: Sixteen patients underwent TEVAR from October 2003 to April 2010. Mean age at operation was 59 years (20~78 years), and 11 were male. Indications for TEVAR were large aortic diameter (>5.5 cm) upon presentation in 6 patients, increasing aortic diameter during the follow-up period in 4, traumatic aortic rupture in 3, persistent chest pain in 2, and ruptured aortic aneurysm in one. The mean diameter, length and the number of the stents were 33 mm (26~40 mm), 12 cm (9.5~16.0 cm), and 1.25 (1~2), respectively. Aortography employing Multi-detector computerized tomography (MDCT) technique was performed at one week, and patients were followed up in the out-patient department at one month, 6 months, and one year postoperatively. Results: Primary technical success showing complete exclusion of the aneurysm was achieved in 15 patients. One patient showed a small endo-leak (type 1). Four patients developed perioperative stroke: Three recovered without sequelae, and one showed mild right-side weakness. There was no operative mortality. Diameter of the thoracic aorta covered by stent graft changed within 10% range in 12 patients, decreased by more than 10% in 3, and increased by more than 10% in one during mean follow-up duration of 18 months (1~73 months). There was no recurrence-related death during this period. Conclusion: Intermediate-term outcome after TEVAR was encouraging. Indications for TEVAR could be extended for other thoracic aortic diseases.

Mid-Term Results of Using the Seal Thoracic Stent Graft in Cases of Aortopathy: A Single-Institution Experience

  • Cho, Jun Woo;Jang, Jae Seok;Lee, Chul Ho;Hwang, Sun Hyun
    • Journal of Chest Surgery
    • /
    • v.52 no.5
    • /
    • pp.335-341
    • /
    • 2019
  • Background: The endovascular approach to aortic disease treatment has been increasingly utilized in the past 2 decades. This study aimed to determine the long-term results of using the Seal thoracic stent graft. Methods: We retrospectively reviewed the outcomes of patients who underwent thoracic endovascular aortic repair or a hybrid procedure using the Seal thoracic stent graft (S&G Biotech, Seongnam, Korea) from January 2008 to July 2018 at a single institution. We investigated in-hospital mortality and the incidence of postoperative complications. We also investigated the mid-term survival rate and incidence of aorta-related complications. Results: Among 72 patients with stent grafts, 15 patients underwent the hybrid procedure and 21 underwent emergency surgery. The mean follow-up period was $37.86{\pm}30.73$ months (range, 0-124 months). Five patients (6.9%) died within 30 days. Two patients developed cerebrovascular accidents. Spinal cord injury occurred in 2 patients. Postoperative renal failure, postoperative extracorporeal membrane oxygenation support, and pneumonia were reported in 3, 1, and 6 patients, respectively. Stent-related aortic complications were observed in 5 patients (6.8%). The 1- and 5-year survival and freedom from stent-induced aortic event rates were 81.5% and 58.7%, and 97.0% and 89.1%, respectively. Conclusion: The use of the Seal thoracic stent graft yielded good mid-term results. Further studies are needed to examine the long-term outcomes of this device.