• Title/Summary/Keyword: Thoracic endovascular repair

Search Result 75, Processing Time 0.02 seconds

Mid-Term Results of Thoracic Endovascular Aortic Repair for Complicated Acute Type B Aortic Dissection at a Single Center

  • Hong, Young Kwang;Chang, Won Ho;Goo, Dong Erk;Oh, Hong Chul;Park, Young Woo
    • Journal of Chest Surgery
    • /
    • v.54 no.3
    • /
    • pp.172-178
    • /
    • 2021
  • Background: Complicated acute type B aortic dissection is a life-threatening condition with high morbidity and mortality. The aim of this study was to report a single-center experience with endovascular stent-graft repair of acute type B dissection of the thoracic aorta and to evaluate the mid-term outcomes. Methods: We reviewed 18 patients treated for complicated acute type B aortic dissection by thoracic endovascular aortic repair (TEVAR) from September 2011 to July 2017. The indications for surgery included rupture, impending rupture, limb ischemia, visceral malperfusion, and paraplegia. The median follow-up was 34.50 months (range, 12-80 months). Results: The median interval from aortic dissection to TEVAR was 5.50 days (range, 0-32 days). There was no in-hospital mortality. All cases of malperfusion improved except for 1 patient. The morbidities included endoleak in 2 patients (11.1%), stroke in 3 patients (16.7%), pneumonia in 2 patients (11.1%), transient ischemia of the left arm in 1 patient (5.6%), and temporary visceral ischemia in 1 patient (5.6%). Postoperative computed tomography angiography at 1 year showed complete thrombosis of the false lumen in 15 patients (83.3%). Conclusion: TEVAR of complicated type B aortic dissection with a stent-graft was effective, with a low morbidity and mortality rate.

Surgical Experience of Persistent Type 2 Endoleaks with Aneurysmal Sac Enlargement after Endovascular Aneurysm Repair

  • Bang, Seung Ho;Park, Jae Bum;Chee, Hyun Keun;Kim, Jun Seok;Jang, Il Soo
    • Journal of Chest Surgery
    • /
    • v.47 no.2
    • /
    • pp.167-170
    • /
    • 2014
  • Herein, we present a case of a successful treatment of persistent type 2 endoleaks associated with aneurysmal sac enlargement after endovascular aneurysm repair in an elderly patient. We confirmed the diagnosis by abdominal computed tomography and selective angiography revealing an 11.0-cm aneurysm sac with type 2 endoleaks. An attempt for the endovascular embolization of collateral arteries was unsuccessful due to anatomic variations and their multiple complex communications. Instead, transperitoneal sacotomy and direct suturing on the feeding target vessels was successfully performed without any endograft damage. In conclusion, sacotomy appears to be a feasible therapeutic substitute where endovascular or other techniques have a high risk of failure and lead to unsuccessful results.

Endovascular Repair in Acute Complicated Type B Aortic Dissection: 3-Year Results from the Valiant US Investigational Device Exemption Study

  • Lim, Chang Young
    • Journal of Chest Surgery
    • /
    • v.50 no.3
    • /
    • pp.137-143
    • /
    • 2017
  • Acute complicated type B aortic dissection (TBAD) is a potentially catastrophic, life-threatening condition. If left untreated, there is a high risk of aortic rupture, irreversible organ or limb damage, or death. Several risk factors have been associated with acute complicated TBAD, including age and refractory hypertension. In the acute phase, even uncomplicated patients are more prone to develop complications if hypertension and pain are left medically untreated. Innovations in stent graft technologies have incrementally improved outcomes since their first use for this condition in 1999, though improvement is needed in mitigating periprocedural complications, adverse events, and mortality. In the past decade, endovascular repair has become the preferred treatment because of its superior outcomes to open repair and medical therapy. The Valiant Captivia Thoracic Stent Graft System is a third-generation endovascular stent graft with advancements in minimally invasive delivery, conformability to the anatomy, and the minimization of adverse sequelae. Herein, this stent graft is briefly reviewed and its 3-year outcomes are presented. Freedom from all-cause and dissection-related mortality was 79.1% and 90.0%, respectiv ely. The Valiant Captiv ia Stent Graft represents a safe, effective intervention for acute complicated TBAD. Continued surveillance is needed to verify its longer-term durability.

Aortopulmonary Fistula Presenting without an Endoleak after Thoracic Endovascular Aortic Repair

  • Sica, Giacomo;Rea, Gaetano;Bocchini, Giorgio;Lombardi, Romilda;Muto, Massimo;Valente, Tullio
    • Journal of Chest Surgery
    • /
    • v.50 no.4
    • /
    • pp.287-290
    • /
    • 2017
  • Herein, we report the case of a 60-year-old man, a smoker with a history of arterial hypertension and diabetes mellitus. After computed tomography (CT) for an episode of hemoptysis, the patient underwent elective thoracic endovascular aortic repair (TEVAR) because of a degenerative aneurysm of the descending thoracic aorta. The area of perianeurysmal pulmonary atelectasis reported on the CT scan was not considered. Three months later, he developed an aortopulmonary fistula without endoleaks. Although TEVAR is a relatively safe procedure, no detail should be overlooked in the preoperative evaluation in order to avoid life-threatening complications. Further, the effectiveness and modality of prolonged antibiotic prophylaxis and/or preoperative respiratory physiotherapy should be assessed in such cases.

Delayed Type III Endoleak Caused by Fabric Erosion after Endovascular Repair of an Abdominal Aortic Aneurysm

  • Lee, Jae Hang;Kim, Eung-joong;Choi, Jin-Ho
    • Journal of Chest Surgery
    • /
    • v.50 no.4
    • /
    • pp.291-294
    • /
    • 2017
  • A 74-year-old patient presented with recurrent aneurysms in the infrarenal abdominal aorta and right common iliac artery 6 years after endovascular aortic repair using endografts in the same location. The patient underwent an aorto-bi-iliac replacement with removal of the stent graft. Two holes measuring 2 mm each were found in the removed graft, and they appeared to have been caused by wear from continuous friction between the endograft and the aortic wall.

Thoracic Duct Embolization with Lipiodol for Chylothorax due to Thoracic Endovascular Aortic Repair with Debranching Procedure

  • Lee, Kwang Hyoung;Jung, Jae Seung;Cho, Sung Bum;Lee, Seung Hun;Kim, Hee Jung;Son, Ho Sung
    • Journal of Chest Surgery
    • /
    • v.48 no.1
    • /
    • pp.74-77
    • /
    • 2015
  • Chylothorax is a rare postoperative complication of a thoracic surgical procedure. Here, we report a case of chylothorax after thoracic endovascular aortic repair with debranching for the distal arch aneurysm of the aorta. First, the patient was treated by a medical method (nil per os, fat-free diet, and octreotide), but this method failed. The patient strongly refused surgical treatment. Therefore, we tried to occlude the thoracic duct by lymphangiography Lipiodol, and this line of treatment was successful.

Aortic Arch Debranching and Antegrade Stent Graft Placement in an Expanding Distal Dissecting Aneurysm after Repair of an Acute Type I Aortic Dissection (Type I 급성 대동맥 박리 수술 후 진행하는 원위부 박리성 동맥류에 대한 대동맥궁 탈분지술과 전향적 대동맥궁 스텐트 그라프트의 설치)

  • Baek, Wan-Ki;Kim, Young-Sam;Lim, Hyun-Kyoung;Yoon, Yang-Han;Kim, Joung-Taek;Kim, Kwang-Ho
    • Journal of Chest Surgery
    • /
    • v.43 no.6
    • /
    • pp.729-733
    • /
    • 2010
  • Endovascular treatment of the aortic aneurysm with a stent graft is rapidly evolving. We describe here a case of hybrid TEVAR (thoracic endovascular aortic repair) in which the stent grafts were placed in the aortic arch after debranching of the arch vessels. The patient had undergone ascending aorta replacement for acute type I aortic dissection 2.5 years earlier. The aneurysmal change of the distal dissection progressed with time. A provisional bypass surgery from the ascending aorta to the innominate artery and left carotid artery was performed and then stent grafts were inserted via an antegrade route that covered the whole aortic arch and proximal descending thoracic aorta.

Use of Embolic Protection Devices during Hybrid Thoracic Endovascular Aortic Repair for a Shaggy Aorta: A Case Report

  • Kim, Eun Chae;Lee, Jae Hang;Chang, Hyoung Woo;Kim, Dong Jung;Kim, Jun Sung;Lim, Cheong;Park, Kay-Hyun
    • Journal of Chest Surgery
    • /
    • v.54 no.6
    • /
    • pp.513-516
    • /
    • 2021
  • An 87-year-old man presented with a saccular aneurysm at the proximal descending thoracic aorta. As computed tomography revealed a shaggy aorta, we planned hybrid thoracic endovascular aortic repair (TEVAR) with embolic protection devices (EPDs) in both internal carotid arteries to prevent a cerebrovascular accident. We inserted an Emboshield NAV6 Embolic Protection System (Abbott Vascular, Abbott Park, IL, USA) into both internal carotid arteries before performing the TEVAR procedure. The patient was discharged from the hospital on postoperative day 4 without any neurological complications.

A Comparative Study of Abdominal Aortic Aneurysm: Endovascular Aneurysm Repair versus Open Repair

  • Bae, Miju;Chung, Sung Woon;Lee, Chung Won;Song, Seunghwan;Kim, Eunji;Kim, Chang Won
    • Journal of Chest Surgery
    • /
    • v.50 no.4
    • /
    • pp.263-269
    • /
    • 2017
  • Background: Endovascular aneurysm repair (EVAR) has dramatically changed the management of abdominal aortic aneurysms (AAAs) as the number of open aneurysm repairs have declined over time. This report compares AAA-related demographics, operative data, complications, and mortality after treatment by open aneurysm repair or EVAR. Methods: We retrospectively reviewed 136 patients with AAAs who were treated over an 8-year time period with open aneurysm repair or EVAR. Results: The mean age of the EVAR group was higher than that of the open repair group (p=0.001), and hospital mortality did not differ significantly between groups (p=0.360). However, overall survival was significantly lower in the EVAR group (p=0.033). Conclusion: Although EVAR is the primary treatment modality for elderly patients, it would be ideal to set slightly more stringent criteria within the anatomical guidelines contained in the instructions for use of the EVAR device when treating younger patients.

Aortic Valve Replacement Using Balloon Catheter for Thoracic Endovascular Aortic Repair to Patient with Calcified Aorta

  • Kim, In Sook;Byun, Joung Hun;Yoo, Byung Ha;Kim, Han Yong;Hwang, Sang Won;Song, Yun Gyu
    • Journal of Chest Surgery
    • /
    • v.46 no.3
    • /
    • pp.212-215
    • /
    • 2013
  • A 79-year-old man was admitted to Samsung Changwon Hospital due to chest pain and dyspnea. The ejection fraction was 31% and mean pressure gradient between the left ventricle and aorta was 69.4 mmHg on echocardiography. Chest computed tomography showed severe calcification of the ascending aorta. Aortic valve replacement was successfully performed using a thoracic endovascular aortic repair balloon catheter without classic aortic cross clamping. The patient was discharged on the eleventh postoperative day.