• Title/Summary/Keyword: Third order aberrations

Search Result 22, Processing Time 0.024 seconds

Optical system design using lens modules I:optimum first order design in zoom lens (렌즈모듈을 이용한 광학계 설계 I: 줌렌즈의 First Order 최적설계)

  • 박성찬;김영식
    • Korean Journal of Optics and Photonics
    • /
    • v.8 no.2
    • /
    • pp.81-87
    • /
    • 1997
  • This paper presents the optimum initial design containing the first and third order properties of the four-group video camera zoom system using lens modules, and its real lens design. The optimum initial design with focal length range of 6.1693 to 58.4065 mm is derived by assigning appropriate first order quantities and third order aberrations to each module along with the specific constraints required for optimization. By scaling the focal length of each lens group, an initial real lens selected for each group has been designed to match its focal length into that of the each lens module, and then combined to establish an actual zoom system by adjusting the air space between the groups at all zoom positions. The combination of the separately designed groups results in a system which satisfies the first order properties of the zoom system consisting of original lens modules. As a result, by residual aberration correction, we could obtain a zoom system useful in video zoom camera employing the rear focus method.

  • PDF

Numerical calculation of contrast transfer function for periodic line-space patterns (주기적인 선물체에 대한 Contrast Transfer Function의 수치계산)

  • 김형수;전영세;이종웅;김성호
    • Korean Journal of Optics and Photonics
    • /
    • v.9 no.6
    • /
    • pp.396-402
    • /
    • 1998
  • The measurement of OTF(optical transfer function) is used for evalution of imaging performance of optical system as a standard method. In the mass-production, the contrast measurement of projected patterns is also popular because of its simplicity. In this study, a computer program which evaluates the CTF(contrast transfer function) of optical system for periodic line-space patterns is developed by using the diffraction imaging theory. The MTF(modulation transfer function) and CTF of an aberrated system are evaluated and analyzed for the third order aberrations expressed by the C-coefficients and the Zemike polynomials.

  • PDF

Design and Aberration Analysis of Four-Spherical Mirror System Corrected for 4 Aberrations (4개의 수차가 보정된 유한 물체점을 갖는 4-구면 반사경계의 설계 및 수차해석)

  • 김종태;공홍진;이상수
    • Korean Journal of Optics and Photonics
    • /
    • v.2 no.3
    • /
    • pp.127-132
    • /
    • 1991
  • We have obtained the analytic solutions of the four spherical mirror system free from the Seidel third order aberratios which are spherical aberration, coma, astigmatism, and distortion, Vignetting. Petzval field curvature, and optical properties according to the design parameters are numerically investigated and optimized. The numerical aperture of this system is 0.2 and the half field angle is $1.5^{\circ}$.

  • PDF

Optical Design of Cemented Doublets by Using Equivalent Lens System (등가렌즈를 이용한 2매 접합렌즈계의 설계)

  • 전영세;김형수;이종웅;박성찬
    • Korean Journal of Optics and Photonics
    • /
    • v.9 no.5
    • /
    • pp.282-290
    • /
    • 1998
  • The equivalent lens conversion technique is applied to design achromatic doublet and aplanatic doublet. A thin doublet which has zero axial thicknesses, are corrected for the third order aberrations at first, and the thin doublet is converted into thick lens system by using the equivalent lens conversion. Two types of cemented doublets, the Fraunhofer type and the Steinheil type, are designed by using a crown glass BaK-2 and a flint glass SF-2. In the thin doublet design, there are two achromatic solutions and a aplanatic solution for the both types.

  • PDF

Parameterized Modeling of Spatially Varying PSF for Lens Aberration and Defocus

  • Wang, Chao;Chen, Juan;Jia, Hongguang;Shi, Baosong;Zhu, Ruifei;Wei, Qun;Yu, Linyao;Ge, Mingda
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.2
    • /
    • pp.136-143
    • /
    • 2015
  • Image deblurring by a deconvolution method requires accurate knowledge of the blur kernel. Existing point spread function (PSF) models in the literature corresponding to lens aberrations and defocus are either parameterized and spatially invariant or spatially varying but discretely defined. In this paper, a parameterized model is developed and presented for a PSF which is spatially varying due to lens aberrations and defocus in an imaging system. The model is established from the Seidel third-order aberration coefficient and the Hu moment. A skew normal Gauss model is selected for parameterized PSF geometry structure. The accuracy of the model is demonstrated with simulations and measurements for a defocused infrared camera and a single spherical lens digital camera. Compared with optical software Code V, the visual results of two optical systems validate our analysis and proposed method in size, shape and direction. Quantitative evaluation results reveal the excellent accuracy of the blur kernel model.

Zoom lens design for compact digital camera using lens modules (렌즈모듈을 이용한 컴팩트 디지털 카메라용 줌 렌즈 설계)

  • Park, Sung-Chan;Lee, Sang-Hun
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.1
    • /
    • pp.34-42
    • /
    • 2005
  • This paper presents the optimum initial design containing the first and third order properties of the three-group zoom system using lens modules, and the real lens design of the system. The optimum initial design with focal length range of 4.3 mm to 8.6 mm is derived by assigning appropriate first and third order quantities to each module along with the specific constraints required for the system. An initial real lens selected for each group has been designed to match its focal length and the first orders into those of the each lens modules, and then combined to establish an actual zoom system by adjusting the air space between the groups at all zoom positions. The combination of the separately designed groups results in a system which satisfies the first order properties of the zoom system composed of the original lens modules. As a result, by residual aberration correction, we could obtain a zoom system useful in compact digital zoom cameras and mobile phone cameras employing the rear focus method.

Off-axis Two-mirror System with Wide Field of View Based on Diffractive Mirror

  • Meng, Qingyu;Dong, Jihong;Wang, Dong;Liang, Wenjing
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.6
    • /
    • pp.604-613
    • /
    • 2015
  • An unobstructed off-axis two-mirror system is presented in this paper. First a suitable initial configuration is established based on third-order aberration theory. In order to achieve a wide field of view (FOV) with high image quality , the diffractive mirror is adopted in the two-mirror system to increase the optimization freedom and the aberration relationship between diffractive phase coefficients and Zernike coefficients is derived. Furthermore, a complete comparison design example with a focal length of 1200 mm, F-number of 12, and FOV of 40° × 2° is given to verify the aberration correction ability of the diffractive mirror. The system average wavefront error is 0.007 λ (λ=0.6328 μm) developed from 0.061 λ when the system didn’t adopt the diffractive mirror. In this system the phase modulation function of the diffractive mirror is established as an even function of x, so we could obtain a symmetrical imaging quality about the tangential plane, and the symmetric aberration performance also brings considerable convenience to alignment and testing for the system.

Baffle design and test for wide-field off-axis telescopes

  • Kim, Sanghyuk;Pak, Soojong;Chang, Seunghyuk;Kim, Geon Hee;Yang, Sun Choel;Lee, Sang Yong;Huh, Myung Sang;Im, Myungshin
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.38 no.1
    • /
    • pp.72.2-72.2
    • /
    • 2013
  • An off-axis telescope has several advantages in optical performance comparing with a conventional on-axis telescope. However, in general, an off-axis telescope has a narrow field of view due to the linear astigmatism caused by the asymmetric structure. It was shown in the previous work that the linear astigmatism can be eliminated by properly configuring parameters in a confocal off-axis reflector system. Furthermore, the third order aberrations of a confocal off-axis telescope can be minimized by optimizing the shape of the mirrors. Despite many advantages, the confocal off-axis telescopes have been evaded because of difficulties of off-axis mirror fabrication, alignment process and unaccustomed off-axis baffle design. The baffle for the off-axis telescope should be designed considering that the effects of stray lights are different because of the asymmetry of off-axis system. In this poster, the design, manufacturing, and test for the baffle and housing of an off-axis telescope are presented.

  • PDF

The Current Status and Educational Requirements for Genetics Curriculum at Nursing Institutions (간호교육에서의 유전학 교육과정 현황과 요구)

  • Hong, Hae-Sook;Byeon, Young-Soon;Na, Yeon-Kyung
    • Journal of Korean Biological Nursing Science
    • /
    • v.5 no.1
    • /
    • pp.13-22
    • /
    • 2003
  • The purpose of this study was to investigate and analyze current educational requirements related to genetics curriculum(from June 2002 to September 2002) established at nursing institutions and to provide the basic data for the development of genetics science program at the undergraduate. Subjects of this study were comprised of twenty-three colleges of nursing in 4-year baccalaureate and thirty colleges in 3-year diploma programs. The results of this study were as follows : 1) 32 colleges offer courses related to genetics. 29 among 32 colleges have that integrated. Three schools have established completely independent courses of genetics. 21 colleges do not have any courses dealing with genetics. 2) The contents of courses related to genetics include: Congenital abnormalities, chromosomal aberrations, congenital metabolic disease, prenatal diagnosis and genetic counseling, genes and chromosomes, immune genetics, blood type and genetics, rule of genetics, variation in gene expression, the map of the human gene, gene linkage genetics, interaction of genes, single inheritance in order and genetic biochemistry. 3) For course credit, 14colleges(48.3%) offered at most 1 credit per course. The grade of student who can take the course, 51.7% were in their second year while 37.9% were in their third year. The majors of nursing faculty who taught the course were nursing(51.7%) and basic nursing science(17.2%). 4) As far as the need of opening the courses related to genetics, 36 colleges(67.0%) have made a 'need', 12 schools(22.6%) state 'dose not need'. 711e reason for need were the following development of bio engineering, increase number of patients who are related to genetics, recognition of the need in clinical nursing. 7 schools(13.2%) agreed to offer independent course in genetics but 39 schools(73.6%) are in disagreement with that. When the school offers the course with other courses, 27 schools(50.0%) are opening basic nursing science and 14 schools(26.4%) are opening nursing as an integrated courses. If the name of course was either genetic nursing(34.0%) or genetics(28.3%), the credits for the course was one or 2 credits. 33 schools(62.3%) students were in the first or second years. 41 schools(84.9%), the majors of the faculty who had taught the course were either basic nursing science(35.8%), nursing(28.3%) or basic medicine(24.5%). The contents of the course should include in that order: Chromosome aberrations, prenatal diagnosis and genetic counseling, congenital metabolic disease, congenital abnormalities, genes and chromosomes, the rules of genetics, immune genetics, interaction of genes, variation in gene expression, etc. The results and discussions of the study indicate that the entire curriculums need to be investigated with respect to contents of education, nursing curriculums and name of courses because of the increasing need of knowledge related to genetics in the clinical practice.

  • PDF

Curvature Linear Equation of a Coma Corrected Two-Mirror System with Finite Object Distance (유한 물체거리를 갖는 코마수차가 보정된 2 반사경계의 곡률선형방정식)

  • Hwang, Seok-Ju;Rim, Cheon-Seog;Jo, Jae-Heung
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.1
    • /
    • pp.19-23
    • /
    • 2007
  • We derived analytically the generalized curvature linear equation useful in the initial optical design of a two-mirror system with finite object distance, including an infinite object distance from paraxial ray tracing and Seidel third order aberration theory for coma coefficient. These aberration coefficients for finite object distance were described by the curvature, the inter-mirror distance, and the effective focal length. The analytical equations were solved by using a computer with a numerical analysis method. Two useful linear relationships, determined by the generalized curvature linear equations relating the curvatures of the two mirrors, for the cancellation of each aberration were shown in the numerical solutions satisfying the nearly zero condition ($<10^{-10}$) for each aberration coefficient. These equations can be utilized easily and efficiently at the step of initial optical design of a two-mirror system with finite object distance.