• Title/Summary/Keyword: Thin slab

Search Result 87, Processing Time 0.025 seconds

Invasive and non-invasive methods for estimating the optical properties of tissue at laser wavelengths (레이저 파장에서의 생체 침습적 및 비침습적 광학계수 측정 방법)

  • Yoon, Gil-Won
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1994 no.12
    • /
    • pp.147-150
    • /
    • 1994
  • To predict light propagation in biological tissues irradiated by laser, the optical properties such as absorption and scattering coefficients are required. There have been various techniques for measuring these coefficients. One method requires tissue samples, often a slab of thin tissue, is invasive. On the other hand, non-invasive method usually measures back-scattered light from a subject with no physical intervent ions. Advantages and disvantages of using different methods are investigated. A careful attention should be made in order to select the best method for a given experimental condition since, even either for invasive or non-invasive method, accuracy is subject to governing models and sample preparations.

  • PDF

STRUCTURE OF A MAGNETIC DECREASE OBSERVED IN A COROTATING INTERACTION REGION

  • LEE, ENSANG;PARKS, GEORGE K.
    • Journal of The Korean Astronomical Society
    • /
    • v.49 no.1
    • /
    • pp.19-23
    • /
    • 2016
  • Magnetic decreases are often observed in various regions of interplanetary space. Many studies are devoted to reveal the physical nature and generation mechanism of the magnetic decreases, but still we do not fully understand magnetic decreases. In this study, we investigate the structure of a magnetic decrease observed in a corotating interaction region using multi-spacecraft measurements. We use three spacecraft, ACE, Cluster, and Wind, which were widely separated in the x- and y-directions in the geocentric solar ecliptic (GSE) coordinates. The boundaries of the magnetic decrease are the same at the three locations and can be identified as tangential discontinuities. A notable feature is that the magnetic decrease has very large dimension, ≳ RE, along the boundary, which is much larger than the size, ~ 6 RE, along the normal direction. This suggests that the magnetic decrease has a shape of a long, thin rod or a wide slab.

A Numerical Study on Temperature Profiles of Steel Plates Heated by Induction Heater (강재의 유도가열 방법의 수치적 승온 해석)

  • Kim, Hyeong-Jin;Chung, Won-Cheol;Cho, Byoung-Soo
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1412-1416
    • /
    • 2003
  • Induction Heaters are commonly used in heating steel strip product, because it can rapidly and efficiently heat steel strip/bar. In this study, a inductive heating model is developed and the predictions are compared with measured temperatures. The temperatures are measured from POSCO thin-slab rolling facility (so called Minimill). Induction heater is installed between reduction unit and holding furnace This induction heater raise the temperature of steel bars from $930^{\circ}C$ to about $1100^{\circ}C$ which gives the required temperature for finishing mill process after holding period at holding furnace. Unlike other simple equation models, this model allows us to predict temperature profiles of sections of steel bars.

  • PDF

기술능력 발전의 시기별 특성: 포항제철 사례연구

  • 송성수
    • Journal of Technology Innovation
    • /
    • v.10 no.1
    • /
    • pp.174-200
    • /
    • 2002
  • Technological capabilities of POSCO (Pohang Iron & Steel Co.) have been developed through acquisition, catch-up, and generation stage. In 1970s standardized operation technologies were acquired based on Japan's technological cooperation. The prime route of technological acquisition was overseas training and operation technologies were articulated by mock and real operation. In 1980s POSCO focused to catch-up advanced technologies through in-house R&D activities. Technological informations were broadly accumulated, task force teams were constructed for important technological tasks, and the scope of technological innovation covered nearly all fields. In 1990s POSCO launched long-term projects based on the large-scale investment and challenged the new fronts of steel technologies. Frontier technologies such as smelting reduction and thin slab casting were early commercialized and new technological concepts were emerged. In conclusion, this article suggests some implications on the development of technological capabilities in Korea.

  • PDF

THE MEASUREMENT OF EXOTHERMIC TEMPERATURE OF VARIOUS DENTAL CEMENTS (각종 치과용 세멘트의 경화열 측정)

  • Pahk, Deok-Sang
    • The Journal of the Korean dental association
    • /
    • v.10 no.8
    • /
    • pp.531-534
    • /
    • 1972
  • The author measured exothermic temperature of the 5 kinds of zinc phosphate cement and 3 kinds of copper phosphate cement during setting process. Cements were mixed on the glass slab with flexible steel spatula at room temperature (25.8℃) for one minute (spatulating speed was 100 strokes per minute) and placed in the incubator of which temperature was held at 37℃ and thermometer was inserted into the cement mass. The powder liquid ration was 3.0gm:1ml and 1.5gm:1ml. The results were as follows. 1) The heat generated after mixing these cements was under 47.22℃. 2) The range of thermal change of the zinc phosphate cements during setting process was wider than copper phosphate cements. 3) The exothermic temperature from the thin mix was higher than thick mix. 4) The exothermic temperature of the zinc phosphate cements was higher than copper phosphate cements.

  • PDF

Effect of Mn and S Contents on Edge Cracking of Low Carbon Steels in Mini-Mill Process (미니밀공정 중 저탄소강의 에지크랙에 미치는 Mn 및 S의 영향)

  • 곽재현;정진환;조경목
    • Transactions of Materials Processing
    • /
    • v.9 no.1
    • /
    • pp.66-71
    • /
    • 2000
  • The present study tackles the metallurgical subjects involving the thin slab-direct hot rolling process, i.e. mini-mill process. In order to clarify the effect of chemical composition of steel and MnS precipitation behaviors on the development of edge cracking during hot rolling, the content of manganese and sulfur in low carbon steel was varied and the isothermal treatment prior to roughing was applied. Edge cracking during roughing in the hot-rolling process of mini-mill was effectively prevented by means of the isothermal treatment at 115$0^{\circ}C$ for 5 minutes in the 0.4% manganese steel containing sulfur lower than 0.013%. With the increase in manganese content in low carbon steel, coarser MnS developed. The edge cracking index which denotes the total length of edge crack per unit edge-length of rolled specimens was proposed in this paper. It was found that the edge cracking index linearly decreased with the increase in the ratio of MnS.

  • PDF

Shear behavior of a demountable bolted connector in steel-UHPC lightweight composite structures

  • Gu, Jin-Ben;Wang, Jun-Yan
    • Structural Engineering and Mechanics
    • /
    • v.81 no.5
    • /
    • pp.551-563
    • /
    • 2022
  • Bolted connector could be an alternative to replace the conventional welded headed stud in steel-ultra high performance concrete (UHPC) lightweight composite structures. In this paper, a novel demountable bolted shear connector, consisting of a high-strength bolt (HSB) and a specially-designed nut which is pre-embedded in a thin UHPC slab, is proposed, which may result in the quick installation and disassembly, due to the mountable, demountable and reusable features. In order to study the shear behavior of the new type of bolted shear connector, static push-out tests were conducted on five groups of the novel demountable bolted shear connector specimens and one group of conventional welded headed stud specimen for comparison. The effect of the bolt shank diameter and aspect ratio of bolt on failure mode, shear stiffness, peak slip at the steel-UHPC interface, shear strength and ductility of novel bolted connectors is investigated. Additionally, design formula for the shear strength is proposed to check the suitability for assessment of the novel demountable bolted shear connectors.

Flexural Behavior of Composite HSB I-Girders in Positive Moment (HSB 강합성거더 정모멘트부 휨거동)

  • Cho, Eun-Young;Shin, Dong-Ku
    • Journal of Korean Society of Steel Construction
    • /
    • v.22 no.4
    • /
    • pp.377-388
    • /
    • 2010
  • The flexural behavior of composite HSB600 and HSB800 I-girders under a positive moment was investigated using the material non-linear moment-curvature analysis method. Three representative composite sections with different ductility properties were selected as the baseline sections in this study. Using these baseline sections, the moment-curvature program was verified by comparing the flexural strength and the moment-curvature curve obtained from the program with those obtained using the non-linear FE analysis of ABAQUS. In the FE analysis, the composite girders were modeled three-dimensionally with flanges, the web, and the concrete slab as thin shell elements, and initial imperfections and residual stresses were imposed on the FE model. In the moment-curvature and FE analyses, the 28-day compressive strength of the concrete slab was assumed to be 30-50 MPa, and the HSB600 and HSB800 steels were modeled as elasto-plastic strain-hardening materials, with the concrete as the CEB-FIP model. The effects of the ductility ratio of the composite girder, the type of steel, the compressive strength of the concrete deck, and the location of the plastic neutral axis on the flexural characteristics were analyzed.

Centrifuge Test for Simulating Behavior of CFRD During Initial Impoundment (초기 담수시 CFRD 거동 모사를 위한 원심모형실험)

  • Seo, Min-Woo;Kim, Yong-Seong
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.10
    • /
    • pp.109-119
    • /
    • 2007
  • As the number of CFRD constructions increases, the necessity of an accurate assessment on its behavior also has been increasing. The performance of concrete faced rockfill dam (CFRD) under different water levels is a great concern of dam engineers and designers in the world. However, domestic research on CFRD design and construction has not been performed sufficiently. This study deals with three centrifuge model tests, mainly investigates quantitatively the deformation of the concrete faced slabs and settlements on the crest with different face slab stiffness. The prototype of a centrifugal model dam is half size of domestic CFRD dam. Detailed material preparation, model design, model set-up, model instrumentation and testing procedures are presented. In order to simulate the prototype concrete faced slab, three kinds of thin fiberglass plates with different thickness were adopted in three model tests. Finally, the centrifuge test results were compared with field measurements of domestic dams, which showed that the centrifuge tests were performed successfully.

Analysis of Flexural Behavior of Composite Beam with Steel Fiber Reinforced Ultra High Performance Concrete Deck and Inverted-T Shaped Steel with Tension Softening Behavior (인장연화거동을 고려한 강섬유 보강 초고성능 콘크리트 바닥판과 역T형 강재 합성보의 휨거동 해석)

  • Yoo, Sung-Won;Yang, In-Hwan;Jung, Sang-Hwa
    • Journal of the Korea Concrete Institute
    • /
    • v.27 no.2
    • /
    • pp.185-193
    • /
    • 2015
  • Ultra high performance concrete (UHPC) has been developed to overcome the low tensile strengths and brittleness of conventional concrete. Considering that UHPC, owing to its composition and the use of steel fibers, develops a compressive strength of 180 MPa as well as high stiffness, the top flange of the steel girder may be superfluous in the composite beam combining a slab made of UHPC and the steel girder. In such composite beam, the steel girder takes the form of an inverted-T shaped structure without top flange in which the studs needed for the composition of the steel girder with the UHPC slab are disposed in the web of the steel girder. This study investigates experimentally and analytically the flexural behavior of this new type of composite beam to propose details like stud spacing and slab thickness for further design recommendations. To that goal, eight composite beams with varying stud spacing and slab thickness were fabricated and tested. The test results indicated that stud spacing running from 100 mm to 2 to 3 times the slab thickness can be recommended. In view of the relative characteristic slip limit of Eurocode-4, the results showed that the composite beam developed ductile behavior. Moreover, except for the members with thin slab and large stud spacing, most of the specimens exhibited results different to those predicted by AASHTO LRFD and Eurocode-4 because of the high performance developed by UHPC.