• Title/Summary/Keyword: Thickness Measurement

Search Result 1,834, Processing Time 0.029 seconds

Reliability and Validity of Ultrasound Imaging and sEMG Measurement to External Abdominal Oblique and Lumbar Multifidus Muscles (외복사근과 다열근에 대한 초음파 영상과 표면 근전도 측정방법의 신뢰도와 타당도)

  • Kim, Chang-Yong;Choi, Jong-Duk;Kim, Suhn-Yeop;Oh, Duck-Won;Kim, Jin-Kyung
    • Physical Therapy Korea
    • /
    • v.18 no.1
    • /
    • pp.37-46
    • /
    • 2011
  • The purpose of this study was to investigate intra-rater reliability and determine the validity of electromyography (EMG) measurements to represent muscle activity and ultrasonography (US) to represent muscle thickness during manual muscle testing (MMT) to external abdominal oblique (EO) and lumbar multifidus (MF). Twenty healthy subjects were recruited for this study and asked to perform MMT at differing levels. The subjects' muscle activity using EMG was measured by a ratio to maximum voluntary contraction (MVC) and root mean square (RMS) methods. The subjects' muscle thickness using US was measured by raw muscle thickness and change ratio of thickness to maximum (MVC) or resting condition. In three trials, measurements were performed on each subject by one examiner. The intra-rater reliability of measurements of EMG and US to EO and MF was calculated using intra-class coefficients. The intra-rater reliability of all measurements was excellent (ICC=.75~.98) in EMG and US. The conduct validity was calculated by one-way ANOVA with repeated measurements to compare whether the EMG and US measurements were different between MMT at different levels. There was only a significant difference between all grades at %MVC thickness measurement of US. These results suggest that a %MVC thickness measurement of US was a more sensitive and discriminate in all manual muscle testing grades. This information will be useful for the selection of US measurement and analysis methods in clinics.

Development of Frost Thickness Measurement Method Using Optical Technique (광학적 기법에 의한 Frost 두께 측정방법의 개발)

  • Jeong, Jae-Hong;Yoon, Sang-Youl;Kim, Kyung-Chun
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.654-659
    • /
    • 2001
  • A new non-contact method of the frost thickness measurement has been developed. The method is based on the digital image processing technique to identify the reflection edge of the image captured by a CCD camera under laser sheet light illumination. To insure the accuracy of frost layer thickness, an in-situ calibration procedure is carried out with a calibration target with 0.5mm holes. Using the mapping function obtained by the calibration procedure, the contour of frost surface can be estimated with sub-pixel resolutions. The developed method is applied to study the effect of cooling plate temperature on the frost thickness in a small low speed wind tunnel.

  • PDF

An experimental study on the behavior of fuel flow in intake manifold by the model (모델에 의한 흡배관내 연료유동의 거동에 관한 실험염구)

  • 박경석
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.5 no.3
    • /
    • pp.33-44
    • /
    • 1983
  • This paper deals with the experimental study on the behavior of fuel (methanol) in intake manifold by using the basic apparatus which is manufactured the visible straight tube type model. In this study, the new device for liquid film thickness measurement and vaporization rate measurement are introduced to investigate the variation of liquid film thickness along the intake manifold and to observe the effect of vaporization of injected fuel. the results are summarized as follows: 1) The vaporization rate increases in proportion to decreasing of throttle valve angle and growing air fuel ratio. 2) The liquid film thickness along the intake manifold is mostly independent for the throttle valve angle in low air velocity and then affected in high air velocity, but the distribution of the liquid film thickness on circumferential position almost constant in the region of 300mm down stream from carburetor. 3) The mean liquid film thickness is 0.04 - 0.18mm in case of methanol in the region of air velocity Va = 12m/s - 55m/s and decreases with decreasing the throttle valve angle.

  • PDF

Spray characteristics of swirl injector using liquid film thickness measurement (액막두께 측정방법을 이용한 스월 인젝터의 분무특성 연구)

  • Kim Sung-Hyuk;Kim Dong-Jun;Kim Byung-Sun;Yoon Young-Bin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.251-255
    • /
    • 2005
  • By using liquid film thickness measurement the spray characteristics of swirl injector according to the geometric parameters were investigated in this paper. A specially designed injector having a variable backhole length, swirl chamber length, orifice length was used to measure the liquid film thickness. The spray characteristics of the injector were represented by mass flow rate according to the injection pressure, liquid film thickness in the lower orifice, spray cone angle.

  • PDF

Study on the Measurement Technology of Fluid Film Thickness with Nanometer Scale by Dichromatic Incident Light (Dichromatic 투사광선에 따른 나노 미터 해상도의 점접촉 유막 두께 측정 연구)

  • 공현상;장시열
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.686-689
    • /
    • 2003
  • Many technologies are applied to the measurement of elastohydrodynamic lubrication (EHL) film thickness. In particular, optical in-situ interferometric method has many advantages in making the actual contact behaviors realized with the experimental apparatus. Careful selection of incident lights greatly enhances the fringe resolution up to nanometer scale by using image processing technology. In this work, it is found that dichromatic incident light can provide much finer resolution of EHL film thickness than monochromatic incident light, because it has much more variables of color components to be discriminated among the wavelengths of colors according the variations of EHL film thickness. Some simulated interferometric images are shown how the film thickness is resolutionized in nanometer scale

  • PDF

A measurement technique for residual thickness of nano-imprinted polymer film using nano-indentation. (나노인덴테이션을 이용한 나노 임프린트된 폴리머 박막의 잔류두께 측정기법)

  • Lee, H.J.;Ko, S.G.;Kim, J.H.;Hur, S.;Lee, E.S.;Jeong, J.H.
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1921-1926
    • /
    • 2003
  • Nano-imprint technology has been vigorously studied by many researchers for it is one of the most promising technologies for manufacturing the pattern with its critical dimension below 100nm. In the nano-imprint technology, nano patterns are transferred on a polymer film and the transferred patterns are used as an etch mask to define the designed patterns on a substrate or a metal layer. To this end, it is important to keep the residual thickness of the imprinted polymer film uniform. In this study, a novel measurement technique to measure the residual thickness of films is proposed based on nanoindentation theory. This technique has advantages of saving time and measuring the residual thickness of highly-localized portions in comparison with other techniques, but has limitation of requiring calibration process.

  • PDF

Description of mandibular bone quality based on measurements of cortical thickness using Mental Index of male and female patients between 40-60 years old

  • Hardanti, Sylviana;Azhari, Azhari;Oscandar, Fahmi
    • Imaging Science in Dentistry
    • /
    • v.41 no.4
    • /
    • pp.151-153
    • /
    • 2011
  • Purpose : The purpose of this study was to obtain the description of the mandibular bone quality of male and female patients between 40-60 years old and their differences based on mandibular cortical bone thickness measured using Mental Index (MI). Materials and Methods : Forty digital panoramic radiographs, which consisted of twenty male and twenty female patients, 40-60 years old, were observed. Mandibular cortical bone thickness was measured using MI on both sides of the mandible. The average MI score of two groups were then assessed using t-sample independent test. Results : There were significant differences of mandibular bone quality based on mandibular cortical bone thickness measurement using MI between male and female patients (p<0.05). Conclusion : Mandibular bone quality based on cortical bone thickness measurement using MI of male and female patients indicated a significant difference.

Method and Application for Reliability Analysis of Measurement Data in Nuclear Power Plant (원전 배관의 두께 측정 데이터에 대한 신뢰도 분석 방법 및 적용)

  • Yun, Hun;Hwang, Kyeongmo;Lee, Hyoseoung;Moon, Seungjae
    • Corrosion Science and Technology
    • /
    • v.14 no.1
    • /
    • pp.33-39
    • /
    • 2015
  • Pipe wall-thinning by flow-accelerated corrosion and various types of erosion is significant damage in secondary system piping of nuclear power plants(NPPs). All NPPs in Korea have management programs to ensure pipe integrity from degradation mechanisms. Ultrasonic test(UT) is widely used for pipe wall thickness measurement. Numerous UT measurements have been performed during scheduled outages. Wall-thinning rates are determined conservatively according to several evaluation methods developed by Electric Power Research Institute(EPRI). The issue of reliability caused by measurement error should be considered in the process of evaluation. The reliability analysis method was developed for single and multiple measurement data in the previous researches. This paper describes the application results of reliability analysis method to real measurement data during scheduled outage and proved its benefits.

The Study of Asymmetrical of the Serratus Anterior and Lower Trapezius Muscles in Chronic Stroke Patients (만성 뇌졸중 환자의 앞 톱니근과 하부 등세모근의 비대칭성 연구)

  • Jeong, Ju-Ri;Lee, Wan-Hee
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.10 no.4
    • /
    • pp.81-90
    • /
    • 2015
  • PURPOSE: The purpose of this study was to compare the muscle architecture of serratus anterior and lower trapezius using rehabilitative ultrasound imaging (RUSI) in affected and unaffected side of chronic stroke patients. METHODS: The participants were thirty five patients with stroke hemiplegia in this study. RUSI was used to measure the muscle thickness of the serratus anterior and lower trapezius muscles. We compared the muscle thickness according to affected side and sex, determined the reliability of the measurement image. Independent t-test, intra-class correlation coefficient (ICC) and standard error of measurement (SEM) were used for statistical analysis. RESULTS: Significant difference in muscle thickness of serratus anterior was observed between affected and unaffected side (p<.001). Muscle thickness according to gender showed a significant difference in unaffected side of serratus anterior (p<.05). Compare asymmetry ratio of serratus anterior and lower trapezius muscle thickness showed a significant difference (p<.001). ICC for intra-reliability was .944~.962 in serratus anterior and .873~.925 in lower trapezius muscle thickness, respectively. SEM was .001~.004 in serratus anterior and .002~.008 in lower trapezius muscle. CONCLUSION: This study, using RUSI, showed significant difference in muscle thickness of serratus anterior in affected and unaffected side of stroke patients. RUSI is a practical tool for measuring soft-tissue thickness in the scapular region muscle of stroke.

A study on tissue compensator thickness ratio and an application for 4MV X-rays (4MV X-선을 이용한 조직보상체 두께비 연구 및 응용)

  • Kim Young-Bum;Jung Hee-Young;Kweon Young-Ho;Kim You-Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.8 no.1
    • /
    • pp.55-61
    • /
    • 1996
  • A radiation beam incident on irregular or sloping surface produces an inhomogeneity of absorbed dose. The use of a tissue compensator can partially correct this dose inhomogeneity. The tissue compensator should be made based on experimentally measured thickness ratio. The thickness ratio depends on beam energy, distance from the tissue compensator to the surface of patient, field size, treatment depth, tissue deficit and other factors. In this study, the thickness ratio was measured for various field size of $5cm{\times}5cm,\;10cm{\times}10cm,\;15cm{\times}15cm,\;20cm{\times}20cm$ for 4MV X-ray beams. The distance to the compensator from the X-ray target was fixed, 49cm, and measurement depth was 3, 5, 7, 9 cm. For each measurement depth, the tissue deficit was changed from 0 to(measurement depth-1)cm by 1cm increment. As a result, thickness ratio was decreased according to field size and tissue deficit was increased. Use of a representative thickness ratio for tissue compensator, there was $10\%$ difference of absorbed dose but use of a experimentally measured thickness ratio for tissue compensator, there was $2\%$ difference of absorbed dose. Therefore, it can be concluded that the tissue compensator made by experimentally measured thickness ratio can produce good distribution with acceptable inhomogeneity and such tissue compensator can be effectively applied to clinical radiotherapy.

  • PDF